首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Six proficiency tests have now been completed in an ongoing program of the UK Food Analysis Performance Assessment Scheme (FAPAS) for the analysis of acrylamide in a range of food matrixes. Homogeneous test material samples were requested by laboratories throughout the world, with 29 to 45 submitting results for each test. Results were analyzed by appropriate statistical procedures, and z-scores were awarded for reported values. In the absence of both legislation and collaborative trial data, the target standard deviation was derived from the Horwitz equation, although it is acknowledged that there is a need to establish a "fit for purpose" target standard deviation specifically for acrylamide analysis. Participants were encouraged to use the analytical method routinely used in their own laboratory and to provide details of their procedure. Close examination of the data submitted indicates that performance is generally acceptable in terms of accuracy. There is no significant difference between results submitted by gas chromatography and liquid chromatography (GC and LC) methods, and no method dependency on the use of internal standards or sample size. However, choice of extraction solvent may be important, with indications that plain water is an acceptable extraction method. There is evidence from the most recent test that direct (underivatized) GC methodology may present problems, but more data are required and this aspect will be monitored in the continuing proficiency testing program.  相似文献   

2.
The European Commission's Directorate General Joint Research Centre has organized several proficiency tests on the determination of acrylamide (AA) in food. This paper presents the results and outcome of a proficiency test that focused on the determination of AA in crispbread samples. One of the goals was the identification of the influence of different parameters such as analyte extraction or instrument calibration on the analytical results. A set of samples, containing 3 different crispbread samples as well as extracts of one crispbread sample and AA standard solutions, was shipped to each participant. A total of 42 European laboratories reported analytical results that were evaluated by applying internationally accepted protocols and procedures. The study found that, for each sample, the results of 4-8 laboratories were outside the range formed by the target value plus or minus the 2-fold of the target standard deviation; thus, they did not perform satisfactorily. In transferring this knowledge to the data of monitoring databases of AA in food, care must be taken that data are quality controlled, as it is likely that some of them may be biased.  相似文献   

3.
Acrylamide levels in a variety of food samples were analyzed before and after 3 months of storage at 10 degrees-12 degrees C. The analysis was performed by liquid chromatography tandem mass spectrometry (LC/MS/MS) using deuterium-labeled acrylamide as internal standard. Acrylamide was stable in most matrixes (cookies, cornflakes, crispbread, raw sugar, potato crisps, peanuts) over time. However, slight decreases were determined for dietary biscuits (83-89%) and for licorice confection (82%). For coffee and cacao powder, a significant decrease occurred during storage for 3 or 6 months, respectively. Acrylamide concentrations dropped from 305 to 210 microg/kg in coffee and from 265 to 180 microg/kg in cacao powder. On the contrary, acrylamide remained stable in soluble coffee as well as in coffee substitutes. Reactions of acrylamide with SH group-containing substances were assumed as the cause for acrylamide degradation in coffee and cacao. Spiking experiments with acrylamide revealed that acrylamide concentrations remained stable in baby food, cola, and beer; however, recovery levels dropped in milk powder (71%), sulfurized apricot (53%), and cacao powder (17%). These observations suggest that variations in the acrylamide content of food, especially in coffee and cacao, can vary depending on the storage time because special food constituents and/or reaction products can affect the levels.  相似文献   

4.
Analytical methods currently employed for determination of acrylamide (AA) in two carbohydrate-rich food samples, crispbread and butter cookies, obtained commercially, and native and spiked bread extract samples have been evaluated in a collaborative study. The objective of the study was to obtain information about the performance of the participating laboratories when analysing samples with an AA content close to the limit of quantification (LOQ) and at a higher AA level, and to investigate the influence of sample-preparation procedures on the results of the analysis. For this purpose an aqueous native extract of white bread crumb, a fortified extract, and AA standard solutions, the analyte content of which were not disclosed to the participants, were included in the study. A total of 62 laboratories, applying seven different measurement techniques and a broad spectrum of analyte extraction and sample-preparation procedures reported their analytical results. Because the measurement data were not normally distributed, they were evaluated by application of robust statistics. The relative performance of the laboratories was highlighted by calculation of z-scores. For the crispbread sample, especially, a large percentage of the calculated z-scores were outside the satisfactory range. From their distribution it became obvious that one of the analytical techniques might be biased, if not applied correctly. Consequently, the impact of the applied methods was examined in more detail. Information about the analytical technique, extraction solvent, quantity weighed, calibration method, clean-up, and the experience of the participating laboratories were extracted from the analytical protocols and transcribed into a data matrix which was evaluated by multifactor analysis of variance. The applied measurement technique seems to have a statistically significant influence on the analytical results.  相似文献   

5.
A new standard reference material (SRM) for drugs of abuse in human serum (SRM 1959) has been developed. This SRM is intended to be used as a control material for laboratories performing analysis of drugs of abuse in blood to evaluate the accuracy of their methods. SRM 1959 is a frozen human serum material fortified with seven compounds for which analyses are performed to determine evidence of illegal drug use: benzoylecgonine (BZE), methadone (METH), methamphetamine (MAMP), morphine (MOR), nordiazepam (NOR), phencyclidine (PCP), and 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THC-9-COOH). Two independent methods involving isotope dilution (ID)-gas chromatography/mass spectrometry (GC/MS) and ID-liquid chromatography/mass spectrometry (LC/MS) were used for the value assignment. For THC-9-COOH, an additional measurement using LC/tandem mass spectrometry (LC/MS/MS) was also included. All methods used isotopically labeled compounds as internal standards and solid-phase extractions to isolate the analytes from the serum. The GC/MS methods used different clean-up procedures from those used for the LC/MS-based methods. Repeatability with within-set coefficients of variation (CVs) ranged from 0.5% to 4.3% for the GC/MS methods and from 0.2% to 1.2% for the LC/MS-based methods. Intermediate precision with between-set CVs for all the methods ranged from 0.1% to 1.1%. Agreement between the GC/MS and LC/MS methods ranged from 0.8% to 8.8%. The results from the methods were combined to obtain the certified concentrations and their expanded uncertainties.  相似文献   

6.
At present, no official criteria exist for drug identification using single quadrupole mass spectrometers although the European Union (EU) criteria for compound identification have been adopted. These criteria are evaluated with respect to the confirmation of cocaine and its metabolites by single quadrupole liquid chromatography/mass spectrometry (LC/MS) and problems are highlighted. Spiked samples, proficiency testing samples, certified reference materials and samples from real cases that had screened positive for cocaine derivatives by immunoassay were subjected to confirmation by LC/MS using single ion monitoring with in‐source fragmentation. The EU criteria for compound identification were applied for the confirmation of cocaine, benzoylecgonine and ecgonine methyl ester. The use of the identification point (IP) system in spiked, proficiency testing samples and certified reference materials provided acceptable results in all cases while in some cases real positive samples did not provide acceptable results. Failure to meet the EU criteria was attributed to low fragmentation at the lower concentrations and the ion suppression effect while both factors affected compliance with the IP system. The identification of cocaine and its metabolites was considerably improved by using a combination of ammonium formate and formic acid as the LC mobile phase. It appears that poor in‐source fragmentation in single quadrupole LC/MS and ion suppression may constitute a problem with drug identification when implementing the IP system in real samples, resulting in false negative results. Further investigation is needed for the use of such IP systems to be suitable for use in LC/MS methods. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
Two new standard reference materials (SRM) for drugs of abuse in human hair have been developed. SRM 2379 consists of hair spiked with cocaine, benzoylecgonine, cocaethylene, phencyclidine, amphetamine, and methamphetamine. SRM 2380 consists of hair spiked with codeine, morphine, monoacetylmorphine, and tetrahydrocannabinol (THC). The SRMs were prepared by soaking the hair in a solution of the target analytes in water-dimethylsulfoxide. The concentration of each analyte was determined using two methods, one based upon gas chromatography/mass spectrometry (GC/MS) and one based upon liquid chromatography/mass spectrometry (LC/MS). Both methods used 0.1 M HCl for extraction of all the analytes from the hair, except for THC, which was extracted with 1 M NaOH. For isolation of the analytes from the extracts, the GC/MS-based methods used different clean-up procedures from those used for the LC/MS-based methods. The results from the two methods were in good agreement with mean differences for the analytes ranging from 4% to 16%. These materials will enable laboratories performing analyses of hair for drugs of abuse to test the accuracy of their methods.  相似文献   

8.
Interlaboratory validation studies have been performed on 2 methods for the determination of chlormequat (CLQ) and mepiquat (MPQ). Both methods used identical extraction procedures and stable isotope internal standardization but differed in the use of liquid chromatography/mass spectrometry (LC/MS) or LC/tandem mass spectrometry (LC/MS/MS) for the determination, the amount of internal standard used, and the expected limit of detection. After addition of deuterated internal standards, CLQ and MPQ were extracted with methanol-water and determined by LC//MS or LC/MS/MS with positive electrospray ionization. Eight European laboratories participated in the LC/MS method study, analyzing mushroom, pear, wheat flour, and fruit puree with residues of CLQ in the range 0.040-1.19 mg/kg and of MPQ in the range 0.041-0.39 mg/kg. For CLQ, the Horwitz ratio (HoRat) values for individual test materials/levels were in the range 0.85-1.13 with a mean of 1.00, showing good method performance. For MPQ, the Ho values for mushroom, pear (both levels), and wheat flour were in the range 0.83-0.94, again indicating good method performance. For the determination of MPQ in infant food (fruit puree) at 0.041 mg/kg, the Ho was 1.7 when a value of 0 reported by one participant was excluded. In the LC/MS/MS study, in which 11 laboratories participated, a separate sample set was analyzed with residues of CLQ in the range 0.007-1.03 mg/kg and of MPQ in the range 0.008-0.72 mg/kg. Ho values for CLQ were in the range 0.27-1.36 and for MPQ in the range 0.51-2.10, all corresponding to acceptable method performance.  相似文献   

9.
Liquid chromatography–tandem mass spectrometry (LC–MS/MS) has been increasingly used in routine clinical laboratories during the last two decades. The high specificity, sensitivity, and multi-analyte potential make it an ideal alternative to immunoassays or conventional high-performance liquid chromatography (HPLC). It also provides higher throughput than gas chromatography–mass spectrometry (GC–MS). LC–MS/MS also offers higher flexibility than immunoassays because LC–MS/MS assays are typically developed in-house. In addition, abundant information can be obtained from a single LC–MS/MS run which can produce a large amount of quantitative or qualitative data. In this review, typical LC–MS/MS clinical applications are presented, personal experiences are shared, and strengths and weakness are discussed. It is foreseeable that LC–MS/MS will become a key instrument in routine clinical laboratories.  相似文献   

10.
A method using gas chromatography/mass spectrometry (GC/MS), liquid chromatography/mass spectrometry (LC/MS) and (1)H NMR with pattern recognition tools such as principle components analysis (PCA) was used to study the human urinary metabolic profiles after the intake of green tea. From the normalized peak areas obtained from GC/MS and LC/MS and peak heights from (1)H NMR, statistical analyses were used in the identification of potential biomarkers. Metabolic profiling by GC/MS provided a different set of quantitative signatures of metabolites that can be used to characterize the molecular changes in human urine samples. A comparison of normalized metabonomics data for selected metabolites in human urine samples in the presence of potential overlapping peaks after tea ingestion from LC/MS and (1)H NMR showed the reliability of the current approach and method of normalization. The close agreements of LC/MS with (1)H NMR data showed that the effects of ion suppression in LC/MS for early eluting metabolites were not significant. Concurrently, the specificity of detecting the stated metabolites by (1)H NMR and LC/MS was demonstrated. Our data showed that a number of metabolites involved in glucose metabolism, citric acid cycle and amino acid metabolism were affected immediately after the intake of green tea. The proposed approach provided a more comprehensive picture of the metabolic changes after intake of green tea in human urine. The multiple analytical approach together with pattern recognition tools is a useful platform to study metabolic profiles after ingestion of botanicals and medicinal plants.  相似文献   

11.
This study summarizes the results obtained from the doping control analysis during the period of the XXVIII summer Olympic Games (30 July-29 August 2004). The analysis of all doping control samples was performed at the Doping Control Laboratory (DCL)—the World Anti-Doping Agency (WADA) Accredited Laboratory of Athens. Three thousand six hundred and seventeen tests were conducted in total throughout the games. In 23 specimens the presence of a prohibited substance was confirmed. Sixteen of those were related to anabolic agents. The screened results were confirmed with various mass spectrometry analytical techniques, such as gas chromatography/high resolution mass spectrometry (GC/HRMS), gas chromatography/mass spectrometry (GC/MS), gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) and liquid chromatography/mass spectrometry (ion trap) (LC/MS). The results of the first time applied screening and confirmatory procedures for the detection of recombinant human growth hormone in serum were also presented. Besides, 107 therapeutic use exemptions (TUE) were verified for glucocorticosteroid and beta2-agonist use.  相似文献   

12.
An improved method was validated for the determination of acrylamide in foods using ultra-performance liquid chromatography (UPLC) coupled to eletrospray ionization tandem mass spectrometry (MS/MS) in the present study. This improved method supplies a rapid quantitative procedure of acrylamide with a run time of only 3 min. Results showed a good repeatability (RSD< or =4.5%) with 50, 100, 250, 500 and 1000 microg/kg spiked concentrations in potato crisps in within-day (n=5) and day-to-day (n=10) precision tests. Meanwhile, good recoveries (81.6-99.0%) were obtained with the same spiked concentrations in acrylamide-free cereal samples (n=3). The excellent method validation data and proficiency test results (Z-score: -0.1) of the official Food Analysis Performance Assessment Scheme (FAPAS) suggested that the present quantitative method could be applied for rapid determination of acrylamide in many investigations.  相似文献   

13.
An analytical method was developed for the determination in urine of 2 metabolites of diazinon: 6-methyl-2-(1-methylethyl)-4(1H)-pyrimidinone (G-27550) and 2-(1-hydroxy-1-methylethyl)-6-methyl-4(1H)-pyrimidinone (GS-31144). Two of the urine sample preparation procedures presented rely on gas chromatography/mass selective detection (GC/MSD) in the selected ion monitoring mode for determination of G-27550. For fast sample preparation and a limit of quantitation (LOQ) of 1.0 ppb, urine samples were purified by using ENV+ solid-phase extraction (SPE) columns. For analyte confirmation at an LOQ of 0.50 ppb, classical liquid/liquid partitioning was used before further purification in a silica SPE column. An SPE sample preparation procedure and liquid chromatography/electrospray ionization/mass spectrometry/mass spectrometry (LC/ESI/MS/MS) were used for both G-27550 and GS-31144. The limit of detection was 0.01 ng for G-27550 with GC/MSD, and 0.016 ng when LC/ESI/MS/MS was used for both G-27550 and GS-31144. The LOQ was 0.50 ppb for G-27550 when GC/MSD and the partitioning/SPE sample preparation procedure were used, and 1.0 ppb for the SPE only sample preparation procedure. The LOQ was 1.0 ppb for both analytes when LC/ESI/MS/MS was used.  相似文献   

14.
A new method based on off‐line coupling of LC with GC in replacement of conventional sample preparation techniques is proposed to analyze acrylamide in coffee brews. The method involves the preseparation of the sample by LC, the collection of the selected fraction, its concentration under nitrogen, and subsequent analysis by GC coupled with MS. The composition of the LC mobile phase and the flow rate were studied to select those conditions that allowed separation of acrylamide without coeluting compounds. Under the conditions selected recoveries close to 100% were achieved while LODs and LOQs equal to 5 and 10 μg/L for acrylamide in brewed coffee were obtained. The method developed enabled the reliable detection of acrylamide in spiked coffee beverage samples without further clean‐up steps or sample manipulation.  相似文献   

15.
A proficiency testing programme might involve a great number of participating laboratories coming from different countries or regions, and normally they analysed the same test materials using their own routine analytical methods. Hence, the results of a proficiency testing programme may contain valuable information which could serve purposes other than just performance evaluation. This study attempted to extract information from the results of a proficiency testing programme for the purposes of educating the participating laboratories as suggested by ISO/IEC 17043. The “bias analysis” approach introduced in this study was based on the statistical model of measurement and the nature of bias in chemical analysis. With this approach, the participating laboratories could estimate the bias associated with different settings of experimental conditions according to the statistics of subset distribution of the reported results from the participating laboratories. This would be useful for them to review the analytical procedures they used and modify their methods if needed. The approach was applied to the analysis of data obtained from a number of past proficiency testing programmes, and the findings were discussed in this paper.  相似文献   

16.
Precise measurement of low enrichment of stable isotope labeled amino‐acid tracers in tissue samples is a prerequisite in measuring tissue protein synthesis rates. The challenge of this analysis is augmented when small sample size is a critical factor. Muscle samples from human participants following an 8 h intravenous infusion of L‐[ring‐13C6]phenylalanine and a bolus dose of L‐[ring‐13C6]phenylalanine in a mouse were utilized. Liquid chromatography tandem mass spectrometry (LC/MS/MS), gas chromatography (GC) MS/MS and GC/MS were compared to the GC‐combustion‐isotope ratio MS (GC/C/IRMS), to measure mixed muscle protein enrichment of [ring‐13C6]phenylalanine enrichment. The sample isotope enrichment ranged from 0.0091 to 0.1312 molar percent excess. As compared with GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS showed coefficients of determination of R2 = 0.9962 and R2 = 0.9942, and 0.9217 respectively. However, the precision of measurements (coefficients of variation) for intra‐assay are 13.0%, 1.7%, 6.3% and 13.5% and for inter‐assay are 9.2%, 3.2%, 10.2% and 25% for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. The muscle sample sizes required to obtain these results were 8 µg, 0.8 µg, 3 µg and 3 µg for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. We conclude that LC/MS/MS is optimally suited for precise measurements of L‐[ring‐13C6]phenylalanine tracer enrichment in low abundance and in small quantity samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
The gingerols, including [6]-, [8]-, and [10]-gingerols, a series of chemical homologs differentiated by the length of their unbranched alkyl chains, have been identified as major active components in fresh ginger rhizome. The purpose of this study was to investigate the utility of ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS) as an online tool to identify and quantify these compounds in raw or processed ginger rhizome samples. Negative mode electrospray ionization (ESI) was used in MS, MS/MS and MS(n) experiments in quadrupole ion trap instruments from two different manufacturers and in high-resolution and accurate mass MS and MS/MS experiments in a Fourier transform ion cyclotron resonance mass spectrometer to elucidate the ionization and fragmentation mechanisms of these compounds in these instruments. Positive mode ESI, which generated many more fragment ions in full scan MS even under gentle ionization conditions, was also used in LC/MS and MS/MS experiments and in direct infusion MS and MS/MS experiments. Consistent and predictable ionization and fragmentation behaviors were observed for all gingerols when analyzed in the same instrument. Instruments from different manufacturers, however, had different ionization mechanisms. The major difference between instruments was their ability to form covalent dimer adducts of the gingerols. Subsequent fragmentation patterns of the precursor ions were essentially identical. These results clearly demonstrate that LC/MS instruments produce data that cannot necessarily be replicated in other laboratories, especially if those laboratories do not have the same instrument model from the same manufacturer. This presents major problems for metabolite target analysis, metabolic profiling and metabolomics investigations, which would benefit from LC/MS mass spectrum libraries as they do from GC/MS mass spectrum libraries, because such libraries may not be valid across platforms.  相似文献   

18.
Yang S  Zhang H  Wang J  Chen F 《色谱》2011,29(5):404-408
建立了气相色谱-质谱(GC-MS)定量测定食品中丙烯酰胺含量的分析方法。选择13C3-丙烯酰胺作为内标物。通过超纯水提取食品中的丙烯酰胺,经正己烷脱脂两次后,在酸性条件下选用溴化钾/溴酸钾为衍生剂进行衍生化反应,再采用乙酸乙酯进行液-液萃取两次,最后用三乙胺将丙烯酰胺转化为更稳定的产物2-溴丙烯酰胺,利用质谱检测器在选择离子扫描模式下测定2-溴丙烯酰胺。该方法在0.05~2.00 mg/kg范围具有良好的线性(r2=0.9995);检出限和定量限分别达到3 μg/kg和7 μg/kg;回收率范围为62.7%~65.5%。通过与前期建立的液相色谱-串联质谱(HPLC-MS/MS)方法进行对比,该法在薯片和面包样品中丙烯酰胺的检测结果略偏高,是一种可以用于常见食品中丙烯酰胺含量测定的分析方法。  相似文献   

19.
Hyphenated mass spectrometric techniques, particularly gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), are indispensable tools in clinical and forensic toxicology and in doping control owing to their high sensitivity and specificity. They are used for screening, library-assisted identification and quantification of drugs, poisons and their metabolites, prerequisites for competent expertise in these fields. In addition, they allow the study of metabolism of new drugs or poisons as a basis for developing screening procedures in biological matrices, most notably in urine, or toxicological risk assessment. Concepts and procedures using GC/MS and LC/MS techniques in the areas of analytical toxicology and the role of mass spectral libraries are presented and discussed in this feature article. Finally, perspectives of their future position are discussed.  相似文献   

20.
Systematic toxicological analysis (STA) is aimed at detecting and identifying all substances of toxicological relevance (i.e. drugs, drugs of abuse, poisons and/or their metabolites) in biological material. Particularly, gas chromatography–mass spectrometry (GC/MS) represents a competent and commonly applied screening and confirmation tool. Herein, we present an untargeted liquid chromatography–tandem mass spectrometry (LC/MS/MS) assay aimed to complement existing GC/MS screening for the detection and identification of drugs in blood, plasma and urine samples. Solid-phase extraction was accomplished on mixed-mode cartridges. LC was based on gradient elution in a miniaturized C18 column. High resolution electrospray ionization-MS/MS in positive ion mode with data-dependent acquisition control was used to generate tandem mass spectral information that enabled compound identification via automated library search in the “Wiley Registry of Tandem Mass Spectral Data, MSforID”. Fitness of the developed LC/MS/MS method for application in STA in terms of selectivity, detection capability and reliability of identification (sensitivity/specificity) was demonstrated with blank samples, certified reference materials, proficiency test samples, and authentic casework samples.  相似文献   