首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Bell SE  Burns DT  Dennis AC  Speers JS 《The Analyst》2000,125(3):541-544
Raman spectroscopy with far-red excitation has been used to study seized, tableted samples of MDMA (N-methyl-3,4-methylenedioxyamphetamine) and related compounds (MDA, MDEA, MBDB, 2C-B and amphetamine sulfate), as well as pure standards of these drugs. We have found that by using far-red (785 nm) excitation the level of fluorescence background even in untreated seized samples is sufficiently low that there is little difficulty in obtaining good quality data with moderate 2 min data accumulation times. The spectra can be used to distinguish between even chemically-similar substances, such as the geometrical isomers MDEA and MBDB, and between different polymorphic/hydrated forms of the same drug. Moreover, these differences can be found even in directly recorded spectra of seized samples which have been bulked with other materials, giving a rapid and non-destructive method for drug identification. The spectra can be processed to give unambiguous identification of both drug and excipients (even when more than one compound has been used as the bulking agent) and the relative intensities of drug and excipient bands can be used for quantitative or at least semi-quantitative analysis. Finally, the simple nature of the measurements lends itself to automatic sample handling so that sample throughputs of 20 samples per hour can be achieved with no real difficulty.  相似文献   

2.
Impurity profiles of 3,4-methylenedioxymethylamphetamine (MDMA) tablets seized in France have been examined. The samples were extracted with methylene chloride under basic conditions and then analyzed by capillary gas chromatography. Almost 30 compounds were identified as precursors, intermediates and by-products. Palmitic and stearic acid were also found as tableting materials. The comparison of the different profiles obtained by the reported procedure provided very useful information about the synthetic processes used by clandestine laboratories and enabled a classification into several groups of profiles. According to these results, the reductive amination route appears to be the most common synthetic pathway in Western Europe. Furthermore, 3,4-methylenedioxyphenyl-2-propanone seems to be the most used precursor in clandestine laboratories.  相似文献   

3.
Bell SE  Barrett LJ  Burns DT  Dennis AC  Speers SJ 《The Analyst》2003,128(11):1331-1335
Here we report the results of the largest study yet carried out on composition profiling of seized "ecstasy" tablets by Raman spectroscopy. Approximately 1500 tablets from different seizures in N. Ireland were analysed and even though practically all the tablets contained MDMA as active constituent, there were very significant differences in their Raman spectra, which were due to variations in both the nature and concentration of the excipients used and/or the degree of hydration of the MDMA. The ratios of the peak heights of the prominent drug bands at 810 cm(-1) and 716 cm(-1) (which vary with hydration state of the drug), and the drug band at 810 cm(-1) against the largest clearly discernible excipient band in the spectrum were measured for all the samples. It was found that there was sufficient variation in composition in the general sample population to make any matches between batches of tablets taken from different seizures significant, rather than the result of random chance. Despite the large number of different batches of tablets examined in this study, only two examples of indistinguishable sets of tablets were found and in only one of these had the two batches of tablets been seized at different times. Finally, the fact that there are many examples of batches of tablets (particularly in different batches taken from single seizures) in which the differences between each set are sufficiently small that they appear to arise only from random variations within a standard manufacturing method implies that, with more extensive data, it may be possible to recognize the "signature" of tablets prepared by major manufacturers.  相似文献   

4.
Raman spectroscopy has become an attractive tool for the analysis of pharmaceutical solid dosage forms. In the present study it is used to ensure the identity of tablets. The two main applications of this method are release of final products in quality control and detection of counterfeits. Twenty-five product families of tablets have been included in the spectral library and a non-linear classification method, the Support Vector Machines (SVMs), has been employed. Two calibrations have been developed in cascade: the first one identifies the product family while the second one specifies the formulation. A product family comprises different formulations that have the same active pharmaceutical ingredient (API) but in a different amount. Once the tablets have been classified by the SVM model, API peaks detection and correlation are applied in order to have a specific method for the identification and allow in the future to discriminate counterfeits from genuine products. This calibration strategy enables the identification of 25 product families without error and in the absence of prior information about the sample. Raman spectroscopy coupled with chemometrics is therefore a fast and accurate tool for the identification of pharmaceutical tablets.  相似文献   

5.
Confocal Raman microspectroscopy has many potential applications in the study of polymer-solvent interactions, including the determination of solvent and polymer-solvent complex depth profiles. This contribution focuses on preventing the formation of polymer-solvent complexes, using surface chemical modification of PVC films. While the surface-specific nature of the film modification is easily demonstrated,[1] confocal Raman measurements clearly show the effects of film refractive index: the modifier depth profile shows a lack of symmetry and the film thickness is underestimated. A spectral normalisation method is described, and this is shown to result in a modifier depth profile which is in good agreement with data obtained by Raman microspectroscopy following physical cross-sectioning of a sample. Alternative techniques for Raman depth profiling are also discussed.  相似文献   

6.
Until 2006 the performance of confocal Raman spectroscopy depth profiling was typically described and modeled through the application of geometrical optics, including refraction at the surface, to explain the degree of resolution and the precise form of the depth profile obtained from transparent and semicrystalline materials. Consequently a range of techniques, physical and analytical, was suggested to avoid the errors thus encountered in order to improve the practice of Raman spectroscopy, if not the understanding of the underlying mechanisms. These approaches were completely unsuccessful in accounting for the precise form of the depth profile, the fact that spectra obtained from laminated samples always contain characteristic peaks from all materials present both well above and below the focal point and that spectra can be obtained when focused some 40 μm above the sample surface. This paper provides further evidence that the physical processes underlying Raman spectroscopy are better modeled and explained through the concept of an extended illuminated volume contributing to the final Raman spectrum and modeled through a photon scattering approach rather than a point focus ray optics approach. The power of this numerical model lies in its ability to incorporate, simultaneously, the effects of degree of refraction at the surface (whether using a dry or oil objective lens), the degree of attenuation due to scatter by the bulk of the material, the Raman scattering efficiency of the material, and surface roughness effects. Through this we are now able to explain why even removing surface aberration and refraction effects through the use of oil immersion objective lenses cannot reliably ensure that the material sampled is only that at or close to the point of focus of the laser. Furthermore we show that the precise form of the depth profile is affected by the degree of flatness of the surface of the sample. Perhaps surprisingly, we show that the degree of flatness of the material surface is, in fact, more important than obtaining a precise refractive index match between the immersion oil and the material when seeking a high-quality depth profile or Raman spectrum from within a transparent or semicrystalline material, contrary to accepted norms that samples for interrogation by Raman spectroscopy require little preparation.  相似文献   

7.
Raman spectroscopy combined with chemometrics has recently become a widespread technique for the analysis of pharmaceutical solid forms. The application presented in this paper is the investigation of counterfeit medicines. This increasingly serious issue involves networks that are an integral part of industrialized organized crime. Efficient analytical tools are consequently required to fight against it. Quick and reliable authentication means are needed to allow the deployment of measures from the company and the authorities. For this purpose a method in two steps has been implemented here. The first step enables the identification of pharmaceutical tablets and capsules and the detection of their counterfeits. A nonlinear classification method, the Support Vector Machines (SVM), is computed together with a correlation with the database and the detection of Active Pharmaceutical Ingredient (API) peaks in the suspect product. If a counterfeit is detected, the second step allows its chemical profiling among former counterfeits in a forensic intelligence perspective. For this second step a classification based on Principal Component Analysis (PCA) and correlation distance measurements is applied to the Raman spectra of the counterfeits.  相似文献   

8.
Kontoyannis CG  Orkoula M 《Talanta》1994,41(11):1981-1984
Laser Raman spectroscopy was used for the quantitative determination of aspirin in aspirin-maize starch tablets. A calibration curve was constructed from spectra obtained from tablets with known quantities of aspirin and starch. The calibration curve is given from the relationship: I(552)/I(478) = (W(aspirin)/W(starch)) x 4.21, where I(552) and I(478) are the relative Raman intensities for the 552 and 478 cm(-1) Raman shift, respectively. W(aspirin) and W(starch) represent the weight of aspirin and starch in a pellet.  相似文献   

9.
Chemical properties of active substances and insoluble excipient within tablets such as crystalline structures can be seen as an important index for solubility of ingredients. Spectroscopic imaging can potentially be a solid solution to understanding mechanisms at the molecular level and it may bring useful insight in terms of process analytical technique. In the present study, generalized two-dimensional (2D) correlation spectroscopy is utilized for the Raman image analysis of pharmaceutical tablets to reveal molecular interactions between chemical components. By using a spatial distance as a perturbation variable in 2D correlation scheme, synchronous and asynchronous correlation analysis becomes possible. Two kinds of pharmaceutical tablets, pentoxifylline (PTX) as an active substance and palmitic acid (PA) as an insoluble excipient, are prepared with different grinding times, 0.5 and 45 min. The 2D correlation analysis of Raman images of the tablets clearly reveals both physical and chemical effects of grinding process on the properties of the tablets. Asynchronous correlations indicate that a specific molecular structural change of PTX related to the crystallinity is induced by the grinding process. Namely, the crystallinity of PTX based on CH2 structure is a key factor to control the solubility of the tablets. Some properties of pharmaceutical tablets, i.e. solubility or distribution of components in turn may become possible by the simple grinding process. Detailed analysis of Raman images becomes possible by the 2D correlation spectroscopy.  相似文献   

10.
The quantification of prednisone in tablets was performed using partial least squares (PLS) models based on FTIR-attenuated total reflection (ATR) and FT-Raman spectra. To compare the predictive ability of these models, the relative standard error of prediction (RSEP) values were calculated. In the case of prednisone determination from the FT-Raman data, RSEP values of 3.1 and 3.2% for the calibration and validation data sets were obtained. For FTIR-ATR models, which were constructed using five spectra for each sample, these errors amounted to 2.6 and 2.9%, respectively. Four commercial products containing 1, 5, 10, and 20 mg prednisone/tablet were quantified. Concentrations derived from the elaborated models correlated strongly with the results of reference analyses and with the declared values (in parentheses). The analyses gave recoveries of 100.0-101.6% (100.1-103.0%) and 98.1-103.2% (100.4-102.9%) for FTIR-ATR and FT-Raman data, respectively. A successful quantification of prednisolone in tablets containing 5 mg active ingredient/tablet was also performed using the PLS model, which was based on FTIR-ATR spectra, with a recovery of 99.8 (98.8%). Both reported spectroscopic techniques can be used as fast and convenient alternatives to the standard pharmacopeial methods of prednisone and prednisolone quantification in solid dosage forms. However, in the case of FTIR-ATR spectroscopy, it is necessary to repeat measurements several times to obtain sufficiently low quantification errors.  相似文献   

11.
Transmission Raman spectroscopy is employed for the first time to analyse model formulations comprising tabletted cocrystals. The ability of transmission Raman to differentiate between formulations on the basis of both drug loading and drug chemistry (cocrystal versus separate components) is investigated.  相似文献   

12.
13.
Breast calcifications are found in both benign and malignant lesions and their composition can indicate the disease state. Calcium oxalate (dihydrate) (COD) is associated with benign lesions, however calcium hydroxyapatite (HAP) is found mainly in proliferative lesions including carcinoma. The diagnostic practices of mammography and histopathology examine the morphology of the specimen. They can not reliably distinguish between the two types of calcification, which may indicate the presence of a cancerous lesion during mammography. We demonstrate for the first time that Kerr-gated Raman spectroscopy is capable of non-destructive probing of sufficient biochemical information from calcifications buried within tissue, and this information can potentially be used as a first step in identifying the type of lesion. The method uses a picosecond pulsed laser combined with fast temporal gating of Raman scattered light to enable spectra to be collected from a specific depth within scattering media by collecting signals emerging from the sample at a given time delay following the laser pulse. Spectra characteristic of both HAP and COD were obtained at depths of up to 0.96 mm, in both chicken breast and fatty tissue; and normal and cancerous human breast by utilising different time delays. This presents great potential for the use of Raman spectroscopy as an adjunct to mammography in the early diagnosis of breast cancer.  相似文献   

14.
Raman spectra of a representative range of β-ketophenethylamine (β-KP), the rapidly growing family of cathinone-related “legal high” recreational drugs, have been recorded. These spectra showed characteristic changes that were associated with the pattern of substitution on the aromatic rings, for example, the compounds carrying substituents at the 4- position could be distinguished from 3,4-methylenedioxy “ecstasy” derivatives. They also showed small but detectable changes with differences in substitution on the ethylamine substituent. These features allowed the β-KPs present in seized casework samples to be identified. The seized samples typically contained only small amounts of bulking agents, which meant that the band intensities of these components within averaged data were very small. In contrast, grid sampling normally gave at least some spectra which had a higher than average proportion of the bulking agent(s), which allowed them to also be identified. This study therefore demonstrates that Raman spectroscopy can be used both to provide a rapid, non-destructive technique for identification of this class of drugs in seized samples and to detect minor constituents, giving a composition profile which can be used for drugs intelligence work.  相似文献   

15.
16.
The network characteristic of a selection of diatomaceous silica derived from China has been investigated using Raman spectroscopy. Before any thermal treatment of the sample, two prominent bands of 607 and circa 493 cm(-1) are resolved in the Raman spectra of diatomaceous silica, corresponding to the (SiO)3-ring breathing mode of D2-line and the O3SiOH tetrahedral vibration mode of D1-line, respectively. This is more similar to the pyrogenic silica rather than the silica gel. For the latter, to obtain a (SiO)3-ring, the sample must be heated between 250 and 450 degrees C. Significant difference is also found between the diatomaceous silica and other natural silicas, e.g. in the Raman spectra of sedimentary and volcanic opals, neither D1 nor D2 band is detected in previous reports.  相似文献   

17.
The detection and identification of dilute bacterial samples by surface-enhanced Raman spectroscopy has been explored by mixing aqueous suspensions of bacteria with a suspension of nanocolloidal silver particles. An estimate of the detection limit of E. coli was obtained by varying the concentration of bacteria. By correcting the Raman spectra for the broad librational OH band of water, reproducible spectra were obtained for E. coli concentrations as low as approximately 103 cfu/mL. To aid in the assignment of Raman bands, spectra for E. coli in D2O are also reported. Figure Light scattering apparatus used to detect bacteria  相似文献   

18.
The application of laser-Raman spectroscopy to the analysis of copolymers of glycidyl methacrylate (GMA) with methyl methacrylate (MMA) and styrene is discussed. For both copolymer systems the line near 1451 cm?1, assigned to the methylene bending mode, was found to be a useful reference. Lines characteristic of each monomer were identified. The intensities of these lines were found to be linearly related to the composition of the copolymers when normalized against the 1451 cm?1 reference. The line near 1730 cm?1, assigned to the carbonyl stretching mode, was also found to be a useful reference for the copolymers of methyl methacrylate and glycidyl methacrylate.  相似文献   

19.
High-pressure behavior of tetramethylsilane, one of the Group IVa hydrides, was investigated by Raman scattering measurements at pressures up to 142 GPa and room temperature. Our results revealed the phase transitions at 0.6, 9, and 16 GPa from both the mode frequency shifts with pressure and the changes of the full width half maxima of these modes. These transitions were suggested to result from the changes in the inter- and intra-molecular bonding of this material. We also observed two other possible phase transitions at 49-69 GPa and 96 GPa. No indication of metallization in tetramethylsilane was found with stepwise compression to 142 GPa.  相似文献   

20.
Raman spectroscopy of gaseous molecules, while not a routine technique, can provide a useful means of probing selected processes: for example, molecular conformation studies and combustion systems. The Raman trace scattering spectrum, obtainable from a suitable combination of the polarized components of the scattered light, is especially well suited for quantitative measurements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号