共查询到20条相似文献,搜索用时 0 毫秒
1.
The direct qualification and quantitation of the volatile organic components of four Eucalyptus camaldulensis fruit samples, obtained from different geographical areas in Turkey, is studied using a direct thermal desorption (DTD) technique coupled with comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry. It is found that the E. camaldulensis sample from Adrasan gave a slightly higher oil yield (1.18%) than the others. The number of components quantitatively identified from Adrasan, Belek, Kuyucak, and Cesme were 46, 54, 55, and 59, respectively. The main compounds found in the volatile oils were: aromadendrene (6.45-15.02%), eucalyptol (0.17-12.61%), gamma-gurjunene (8.40-10.08%), terpinolen (1.98-8.39%), spathulenol (1.42-8.34%), alpha-pinene (0.85-6.81%), ledene (0.94-6.72%), and longifonene (0.07-6.22%). The composition of the volatiles desorbed from samples from all four different areas varied qualitatively and quantitatively. All identified compounds were quantitated using total ion chromatogram peak areas. DTD is a good method for qualitative and/or quantitative analysis of complex mixtures, and in particular for quantitative analysis of plant samples, which can yield data without the traditional obligation for costly and time consuming extraction techniques. 相似文献
2.
3.
d'Acampora Zellner B Casilli A Dugo P Dugo G Mondello L 《Journal of chromatography. A》2007,1141(2):279-286
The analysis of complex matrices, such as perfumes, by means of gas chromatography-olfactometry (GC-O) can be rather imprecise due to the co-elutions, leading to a possible masking of odour-active trace-level compounds by major interferences or agglomeration of olfactive impressions resulting in unreliable olfactive characterization. To overcome these limits an innovative technique, comprehensive two-dimensional gas chromatography-olfactometry (GC x GC-O), was applied, revealing several relevant co-elutions, as in the linalool and linalyl acetate zones. A total of 177 compounds, out of these 135 odour-active, were detected by GC-O, while about 481 out of 818 compounds presented odour-activity through GC x GC-O analyses. In addition, GC/mass spectrometry (GC/MS) and GC x GC/MS analyses were also performed. Peak assignment was achieved by means of different information sources, such as GC/MS, GC x GC/MS, LRI, injection of standards and olfactive impressions. 相似文献
4.
Pedroso MP de Godoy LA Ferreira EC Poppi RJ Augusto F 《Journal of chromatography. A》2008,1201(2):176-182
A method to detect potential adulteration of commercial gasoline (Type C gasoline, available in Brazil and containing 25% (v/v) ethanol) is presented here. Comprehensive two-dimensional gas chromatography with flame ionization detection (GCxGC-FID) data and multivariate calibration (multi-way partial least squares regression, N-PLS) were combined to obtain regression models correlating the concentration of gasoline on samples from chromatographic data. Blends of gasoline and white spirit, kerosene and paint thinner (adopted as model adulterants) were used for calibration; the regression models were evaluated using samples of Type C gasoline spiked with these solvents, as well as with ethanol. The method was also checked with real samples collected from gas stations and analyzed using the official method. The root mean square error of prediction (RMSEP) for gasoline concentrations on test samples calculated using the regression model ranged from 3.3% (v/v) to 8.2% (v/v), depending on the composition of the blends; in addition, the results for the real samples agree with the official method. These observations suggest that GCxGC-FID and N-PLS can be an alternative for routine monitoring of fuel adulteration, as well as to solve several other similar analytical problems where mixtures should be detected and quantified as single species in complex samples. 相似文献
5.
The identification of unknown compounds in complex samples is very difficult. Comprehensive two-dimensional gas chromatography (GC x GC) provides very good resolution and improved identification reliability. Mass spectrometry is a powerful identification tool and retention index data are another good approach to this end. In this study, a second-order polynomial was used to calculate retention index data based on n-alkanes beyond the region of the 'isovolatile' curve in GC x GC, and the results in the 2nd dimension were validated by using the same stationary phase column in one-dimensional GC. To test the usefulness of the method, volatile compounds in a tobacco leaf extract fraction were analyzed using GC x GC, and 60 compounds were identified on the basis of their retention indices. 相似文献
6.
Lu X Zhao M Kong H Cai J Wu J Wu M Hua R Liu J Xu G 《Journal of chromatography. A》2004,1043(2):265-273
Gas chromatography-mass spectrometry with electron ionization and positive-ion chemical ionization and comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC x GC-TOF-MS) were applied for the characterization of the chemical composition of complex hydrocarbons in the non-polar neutral fraction of cigarette smoke condensates. Automated data processing by TOF-MS software combined with structured chromatograms and manual review of library hits were used to assign the components from GC x GC-TOF-MS analysis. The distributions of aliphatic hydrocarbons and aromatics were also investigated. Over 100 isoprenoid hydrocarbons were detected, including carotene degradation products, phytadiene isomers and carbocyclic diterpenoids. A total of 1800 hydrocarbons were tentatively identified, including aliphatic hydrocarbons, aromatics, and isoprenoid hydrocarbons. The identified hydrocarbons by GC x GC-TOF-MS were far more than those by GC-MS. 相似文献
7.
Almstetter MF Appel IJ Dettmer K Gruber MA Oefner PJ 《Journal of chromatography. A》2011,1218(39):7031-7038
The alignment algorithm Statistical Compare (SC) developed by LECO Corporation for the processing of comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC×GC-TOFMS) data was validated and compared to the in-house developed retention time correction and data alignment tool INCA (Integrative Normalization and Comparative Analysis) by a spike-in experiment and the comparative metabolic fingerprinting of a wild type versus a double mutant strain of Escherichia coli (E. coli). Starting with the same peak lists generated by LECO's ChromaTOF software, the accuracy of peak alignment and detection of 1.1- to 4-fold changes in metabolite concentration was assessed by spiking 20 standard compounds into an aqueous methanol extract of E. coli. To provide the same quality input signals for both alignment routines, the universal m/z 73 trace of the trimethylsilyl (TMS) group was used as a quantitative measure for all features. The performance of data processing and alignment was evaluated and illustrated by ROC curves. Statistical Compare performed marginally better at the lower fold changes, while INCA did so at the higher fold changes. Using SC, quantitative precision could be improved substantially by exploiting the signal intensities of metabolite-specific unique (U) m/z ion traces rather than the universal m/z 73 trace. A list of 56 features that distinguished the two E. coli strains was obtained by the SC alignment using m/z U with an estimated false discovery rate (FDR) of <0.05. Ultimately, 23 metabolites could be identified, one additional and five less than with INCA due to the failure of SC to extract unitized m/z U's across all fingerprints with suitable spectral intensities for the latter metabolites. 相似文献
8.
Pedroso MP Ferreira EC Hantao LW Bogusz S Augusto F 《Journal of separation science》2011,34(13):1547-1554
Combining qualitative data from the chromatographic structure of 2-D gas chromatography with flame ionization detection (GC×GC-FID) and that from gas chromatography-mass spectrometry (GC/MS) should result in a more accurate assignment of the peak identities than the simple analysis by GC/MS, where coelution of analytes is unavoidable in highly complex samples (rendering spectra unsuitable for qualitative purposes) or for compounds in very low concentrations. Using data from GC×GC-FID combined with GC/MS can reveal coelutions that were not detected by mass spectra deconvolution software. In addition, some compounds can be identified according to the structure of the GC×GC-FID chromatogram. In this article, the volatile fractions of fresh and dehydrated pineapple pulp were evaluated. The extraction of the volatiles was performed by dynamic headspace extraction coupled to solid-phase microextraction (DHS-SPME), a technique appropriate for slurries or solid matrices. Extracted analytes were then analyzed by GC×GC-FID and GC/MS. The results obtained using both techniques were combined to improve compound identifications. 相似文献
9.
The two-dimensional (2D) data structure generated under a high resolution GC×GC system with a small number of samplings taken across the first dimension is evaluated for the purpose of the application of chemometric deconvolution methods. Chemometric techniques such as generalized rank annihilation method (GRAM) place high demands on the reproducibility of chromatographic experiments. For GRAM to be employed for GC×GC data interpretation, it is critical that the separation method provides data with a bilinear structure; the peak-shape and retention times on both columns must be reproducible. With a limited number of samplings across a 1D (first dimension) peak (e.g. four to six samplings) repeatability of the pattern of the modulated peaks (controlled by the modulation phase) becomes important in producing a bilinear data structure. Reproducibility of modulation phase can be affected by both reliability of the modulation period and reproducibility of the retention time of the peak on the first column (which arises from oven temperature and carrier flow rate stability). Evaluation of within-run and run-to-run retention time reproducibility (retention time uncertainty) on both columns, and modulation phase reproducibility using a modulated cryogenic system for a pair of overlapping components (fatty acid methyl esters) was undertaken. An investigation of the quality of data to permit quantification of each component by using GRAM deconvolution, was also conducted. Less than 4% run-to-run retention time uncertainty was obtained on column 1 and less than 9% run-to-run and within-run retention time uncertainty was obtained on column 2, where these R.S.D. measures are reported normalised to peak widths on each respective dimension. The R.S.D. of duplicate quantification results by GRAM ranged from 2 to 26% although the average quantification error using GRAM was less than 5%. 相似文献
10.
This paper describes a language for expressing criteria for chemical identification with comprehensive two-dimensional gas chromatography paired with mass spectrometry (GC x GC-MS) and presents computer-based tools implementing the language. The Computer Language for Indentifying Chemicals (CLIC) allows expressions that describe rules (or constraints) for selecting chemical peaks or data points based on multi-dimensional chromatographic properties and mass spectral characteristics. CLIC offers chromatographic functions of retention times, functions of mass spectra, numbers for quantitative and relational evaluation, and logical and arithmetic operators. The language is demonstrated with the compound-class selection rules described by Welthagen et al. [W. Welthagen, J. Schnelle-Kreis, R. Zimmermann, J. Chromatogr. A 1019 (2003) 233-249]. A software implementation of CLIC provides a calculator-like graphical user-interface (GUI) for building and applying selection expressions. From the selection calculator, expressions can be used to select chromatographic peaks that meet the criteria or create selection chromatograms that mask data points inconsistent with the criteria. Selection expressions can be combined with graphical, geometric constraints in the retention-time plane as a powerful component for chemical identification with template matching or used to speed and improve mass spectrum library searches. 相似文献
11.
Volatile constituents in wine and brewed coffee were analyzed using a combined system incorporating both GC-olfactometry (GC-O) and comprehensive two-dimensional GC-flame ionization detection (GC×GC-FID). A column set consisting of a 15m first dimension ((1)D; DB-FFAP (free fatty acid phase)), and a 1.0m (2)D column (DB-5 phase) was applied to achieve the GC×GC separation of the volatile extracts isolated by using solid phase extraction (SPE). While 1D GC resulted in many overlapping peaks, GC×GC allowed resolution of co-eluting compounds which coincided with the odour region located using GC-O. Character-impact odourants were tentatively identified through data correlation of GC×GC contour plots across results obtained using either time-of-flight mass spectrometry (TOFMS), or with flame photometric detection (FPD) for sulfur speciation. The odourants 2-methyl-2-butenal, 2-(methoxymethyl)-furan, dimethyl trisulfide, 2-ethyl-5-methyl-pyrazine, 2-octenal, 2-furancarboxaldehyde, 3-mercapto-3-methyl-1-butanol, 2-methoxy-3-(2-methylpropyl)-pyrazine, 2-furanmethanol and isovaleric acid were suspected to be particularly responsible for coffee aroma using this approach. The presented methodology was applied to identify the potent odourants in two different Australian wine varietals. 1-Octen-3-ol, butanoic acid and 2-methylbutanoic acid were detected in both Merlot and a Sauvignon Blanc+Semillon (SV) blend with high aroma potency. Several co-eluting peaks of ethyl 4-oxo-pentanoate, 3,7-dimethyl-1,5,7-octatrien-3-ol, (Z)-2-octen-1-ol, 5-hydroxy-2-methyl-1,3-dioxane were likely contributors to the Merlot wine aroma; while (Z)-3-hexen-1-ol, β-phenylethyl acetate, hexanoic acid and co-eluting peaks of 3-ethoxy-1-propanol and hexyl formate may contribute to SV wine aroma character. The volatile sulfur compound 2-mercapto-ethyl acetate was believed to contribute a fruity, brothy, meaty, sulfur odour to Australian Merlot and SV wines. 相似文献
12.
A new approach of flow modulation comprehensive two-dimensional gas chromatography-mass spectrometry (GC x GC-MS) with supersonic molecular beam (SMB) and a quadrupole mass analyzer is presented. Flow modulation uniquely enables GC x GC-MS to be achieved even with the limited scan speed of quadrupole MS, and its 20 ml/min column flow rate is handled, splitless, by the SMB interface. Flow modulation GC x GC-SMB-MS shares all the major benefits of GC x GC and combines them with GC-MS including: (a) increased GC separation capability; (b) improved sensitivity via narrower GC peaks; (c) improved sensitivity through reduced matrix interference and chemical noise; (d) polarity and functional group sample information via the order of elution from the second polar column. In addition, GC x GC-SMB-MS is uniquely characterized by the features of GC-MS with SMB of enhanced and trustworthy molecular ion plus isotope abundance analysis (IAA) for improved sample identification and fast fly-through ion source response time. The combination of flow modulation GC x GC with GC-MS with SMB (supersonic GC-MS) was explored with complex matrices such as diesel fuel analysis and pesticide analysis in agricultural products. 相似文献
13.
Garry Milman Allan J. BarnesRoss H. Lowe Marilyn A. Huestis 《Journal of chromatography. A》2010,1217(9):1513-1521
Development and validation of a method for simultaneous identification and quantification of Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD), cannabinol (CBN), and metabolites 11-hydroxy-THC (11-OH-THC) and 11-nor-9-carboxy-THC (THCCOOH) in oral fluid. Simultaneous analysis was problematic due to different physicochemical characteristics and concentration ranges. Neutral analytes, such as THC and CBD, are present in ng/mL, rather than pg/mL concentrations, as observed for the acidic THCCOOH biomarker in oral fluid. THCCOOH is not present in cannabis smoke, definitively differentiating cannabis use from passive smoke exposure. THC, 11-OH-THC, THCCOOH, CBD, and CBN quantification was achieved in a single oral fluid specimen collected with the Quantisal™ device. One mL oral fluid/buffer solution (0.25 mL oral fluid and 0.75 mL buffer) was applied to conditioned CEREX® Polycrom™ THC solid-phase extraction (SPE) columns. After washing, THC, 11-OH-THC, CBD, and CBN were eluted with hexane/acetone/ethyl acetate (60:30:20, v/v/v), derivatized with N,O-bis-(trimethylsilyl)trifluoroacetamide and quantified by two-dimensional gas chromatography electron ionization mass spectrometry (2D-GCMS) with cold trapping. Acidic THCCOOH was separately eluted with hexane/ethyl acetate/acetic acid (75:25:2.5, v/v/v), derivatized with trifluoroacetic anhydride and hexafluoroisopropanol, and quantified by the more sensitive 2D-GCMS–electron capture negative chemical ionization (NCI-MS). Linearity was 0.5–50 ng/mL for THC, 11-OH-THC, CBD and 1–50 ng/mL for CBN. The linear dynamic range for THCCOOH was 7.5–500 pg/mL. Intra- and inter-assay imprecision as percent RSD at three concentrations across the linear dynamic range were 0.3–6.6%. Analytical recovery was within 13.8% of target. This new SPE 2D-GCMS assay achieved efficient quantification of five cannabinoids in oral fluid, including pg/mL concentrations of THCCOOH by combining differential elution, 2D-GCMS with electron ionization and negative chemical ionization. This method will be applied to quantification of cannabinoids in oral fluid specimens from individuals participating in controlled cannabis and Sativex® (50% THC and 50% CBD) administration studies, and during cannabis withdrawal. 相似文献
14.
Rowland SJ West CE Scarlett AG Jones D Frank RA 《Rapid communications in mass spectrometry : RCM》2011,25(9):1198-1204
The oils sands industry of Canada produces large volumes of process water (OSPW) which is stored in large lagoons. The OSPW contains complex mixtures of somewhat toxic, water-soluble, acid-extractable organic matter sometimes called 'naphthenic acids' (NA). Concerns have been raised over the possible environmental impacts of leakage of OSPW and a need has therefore arisen for better characterisation of the NA. Recently, we reported the first identification of numerous individual tricyclic NA in OSPW by comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry (GCxGC/ToF-MS) of the methyl esters. The acids were diamondoid adamantane acids, resulting, it was proposed, from biotransformation of the corresponding alkyladamantane hydrocarbons, which is a known process. Biotransformation of higher alkylated diamondoid hydrocarbons was, until now, unknown but here we describe the identification of numerous pentacyclic NA as diamantane and alkyldiamantane acids, using the same methods. Further, we suggest tentative structures for some of the tetracyclic acids formed, we propose, by ring-opening of alkyldiamantanes. We suggest that this is further evidence that some of the acid-extractable organic matter in the OSPW originates from extensive biodegradation of the oil, whether in-reservoir or environmental, although other oxidative routes (e.g. processing) may also be possible. The results may be important for helping to better focus reclamation and remediation strategies for NA and for facilitating the identification of the sources of NA in contaminated environmental samples. 相似文献
15.
Schoenmaker PJ Oomen JL Blomberg J Genuit W van Velzen G 《Journal of chromatography. A》2000,892(1-2):29-46
In this paper, we compare the current separation power of comprehensive two-dimensional gas chromatography (GCxGC) with the potential separation power of GC-mass spectrometry (GC-MS) systems. Using simulated data, we may envisage a GC-MS contour plot, that can be compared with a GCxGC chromatogram. Real examples are used to demonstrate the current potential of the two techniques in the field of hydrocarbon analysis. As a separation technique for complex hydrocarbon mixtures, GCxGC is currently about as powerful as GC-MS is potentially powerful. GC-MS has not reached its potential separation power in this area, because a universal, soft ionization method does not exist. The greatest advantage of GCxGC is, however, its potential for quantitative analysis. Because flame-ionisation detection can be used, quantitative analysis by GCxGC is much more robust, reliable and reproducible. 相似文献
16.
Jitka Zrostlikova Joe Binkley Petr Wojtowicz Tomas Adam 《Journal of Analytical Chemistry》2011,66(13):1333-1340
In this paper several characteristic features of time-of-flight mass spectrometry in coupling with gas chromatography are
demonstrated and the parameters are compared to quadrupole mass analyzer. In the second part, the comprehensive two-dimensional
gas chromatography coupled to time-of-flight mass spectrometry was applied in human metabolomic field, particularly in the
determination of pathological markers of Inherited Metabolic Disorders (IMDs). 相似文献
17.
A sample of tobacco essential oil was analyzed using gas chromatography-mass spectrometry (GC/MS) and comprehensive two-dimensional gas chromatography coupled to a time-of-flight mass spectrometry (GC × GC/TOFMS), respectively. In the GC/MS analysis, serially coupled columns were used. By comparing the GC/MS results with GC × GC/TOFMS results, many more components in the essential oil could be found within the two-dimensional separation space of GC × GC. The quantitative determination of components in the essential oil was performed by GC × GC with flame ionization detection (FID), using a method of multiple internal standards calibration. 相似文献
18.
The reddish brown haze that surrounds Titan, Saturn's largest moon, is thought to consist of tholin-like organic aerosols. Tholins are complex materials of largely unknown structure. The very high peak capacity and structured chromatograms obtained from comprehensive two-dimensional GC (GC x GC) are attractive attributes for the characterization of tholin pyrolysis products. In this report, GC x GC with time-of-flight MS detection and a flash pyrolysis inlet is used to characterize tholin pyrolysis products. Identified pyrolysis products include low-molecular-weight nitriles, alkyl substituted pyrroles, linear and branched hydrocarbons, alkyl-substituted benzenes and PAH compounds. The pyrolysis of standards found in tholin pyrolysate showed that little alteration occurred and thus these structures are likely present in the tholin material. 相似文献
19.
David K. Pinkerton Brendon A. ParsonsTodd J. Anderson Robert E. Synovec 《Analytica chimica acta》2015
Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC–TOFMS) is a well-established instrumental platform for complex samples. However, chemometric data analysis is often required to fully extract useful information from the data. We demonstrate that retention time shifting from one modulation to the next, Δ2tR, is not sufficient alone to quantitatively describe the trilinearity of a single GC × GC–TOFMS run for the purpose of predicting the performance of the chemometric method parallel factor analysis (PARAFAC). We hypothesize that analyte peak width on second dimension separations, 2Wb, also impacts trilinearity, along with Δ2tR. The term trilinearity deviation ratio, TDR, which is Δ2tR normalized by 2Wb, is introduced as a quantitative metric to assess accuracy for PARAFAC of a GC × GC–TOFMS data cube. We explore how modulation ratio, MR, modulation period, PM, temperature programming rate, Tramp, sampling phase (in-phase and out-of-phase), and signal-to-noise ratio, S/N, all play a role in PARAFAC performance in the context of TDR. Use of a PM in the 1–2 s range provides an optimized peak capacity for the first dimension separation (500–600) for a 30 min run, with an adequate peak capacity for the second dimension separation (12–15), concurrent with an optimized two-dimensional peak capacity (6000–7500), combined with sufficiently low TDR values (0–0.05) to facilitate low quantitative errors with PARAFAC (0–0.5%). In contrast, use of a PM in the 5 s or greater range provides a higher peak capacity on the second dimension (30–35), concurrent with a lower peak capacity on the first dimension (100–150) for a 30 min run, and a slightly reduced two-dimensional peak capacity (3000–4500), and furthermore, the data are not sufficiently trilinear for the more retained second dimension peaks in order to directly use PARAFAC with confidence. 相似文献
20.
Rowland SJ West CE Scarlett AG Jones D 《Rapid communications in mass spectrometry : RCM》2011,25(12):1741-1751
The identification of most individual members of the complex mixtures of carboxylic acids found in petroleum ('naphthenic acids') has eluded chemists for over a century; they remain unresolved by conventional gas chromatographic methods. Recently, however, we successfully used two-dimensional comprehensive gas chromatography/mass spectrometry to identify numerous individual diamondoid acids in the naphthenic acids of oil sands process water (OSPW). We have now applied the same methods to a study of a mixture of commercially available naphthenic acids originally refined from petroleum. The results confirm that OSPW and refined petroleum contain very different distributions of acids, as noted previously, although some of the diamondoid acids recently identified in OSPW were detectable in both. Rather, two-dimensional comprehensive gas chromatography/time-of-flight mass spectrometry (GCxGC/ToF-MS) of the methyl esters of the petroleum acids and of numerous acids synthesised for comparison showed that the former comprised mainly C(8-18) straight-chain, methyl-branched, acyclic isoprenoid, cyclohexyl and isomeric octahydropentalene, perhydroindane and perhydronaphthalene (decalin) acids. Some of the latter bicyclic acids occurred as both the non-alkyl-substituted isomers and the bicyclic ethanoic and propanoic acids. Also present in minor quantities was a range of phenyl carboxylic and substituted phenyl alkanoic acids, and traces of non-acids, including trimethylnaphthalenes, again identified by comparison with the synthesised compounds. These results represent some of the first identifications of multiple individual naphthenic acids in commercial mixtures originating from petroleum and provide a basis for future studies of the petroleum geochemistry, toxicities and environmental impacts of the acids. Furthermore, characterisation of the acids will be important for improving the understanding of the role of naphthenic acids in petroleum engineering, particularly for oil pipeline deposition problems. 相似文献