首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We demonstrate multiphoton discrimination at a telecommunications wavelength with the readout frequency of 40 Hz by a charge-integration photon detector (CIPD). The CIPD consists of an InGaAs pin photodiode and a GaAs junction field effect transistor as a preamplifier in a charge-integration circuit, which is cooled to 4.2 K to reduce thermal noise. The quantum efficiency of the CIPD (the detector itself) is 80% for 1530 nm light, and the readout noise is measured as 0.26 electrons at 40 Hz. We can construct Poisson distributions of photocarrier numbers with distinct peaks at each photocarrier number, corresponding to a signal-to-noise ratio of about 3.  相似文献   

2.
Monaural detection with a contralateral cue (MDCC) was measured with and without a 20-dB overall roving level to determine the contribution of loudness to performance on this task. Psychometric functions were obtained for three normal-hearing subjects as a function of the signal-to-noise ratio for pure-tone and 1/3-oct noiseband signals at 500 and 4000 Hz with a wideband noise masker. At 4000 Hz, the roving level degrades performance for the narrow-band noise signal by about 5.3 dB. In addition, the presence of the contralateral cue degrades performance for both the pure-tone and narrow-band noise signals at 4000 Hz by 3 to 6 dB. At 500 Hz, however, performance is not affected by the roving level, and is improved by 3 to 6 dB by the contralateral cue. These results indicate that loudness is being used as a cue only for detection of the 4000-Hz narrow-band noise.  相似文献   

3.
The frequency noise properties of commercial distributed feedback quantum cascade lasers emitting in the 4.6 μm range and operated in cw mode near room temperature (277 K) are presented. The measured frequency noise power spectral density reveals a flicker noise dropping down to the very low level of <100 Hz(2)/Hz at 10 MHz Fourier frequency and is globally a factor of 100 lower than data recently reported for a similar laser operated at cryogenic temperature. This makes our laser a good candidate for the realization of a mid-IR ultranarrow linewidth reference.  相似文献   

4.
A highly sensitive photodetection system with a detection limit of 1 photon/s was developed. This system uses a commercially available 200-microm-diameter silicon avalanche photodiode (APD) and an in-house-developed ultralow-noise readout circuit, which are both cooled to 77 K. When the APD operates at a low gain of approximately 10, it has a high-linearity response to the number of incident photons and a low excess noise factor. The APD also has a high quantum efficiency and a dark current of less than 1 e/s at 77 K. This photodetection system will shorten measurement time and permit higher spatial and wavelength resolution for near-field scanning optical microscopes.  相似文献   

5.
Terahertz(THz) direct detectors based on superconducting niobium nitride(NbN) hot electron bolometers(HEBs) with microwave(MW) biasing are studied. The MW is used to bias the HEB to the optimum point and to readout the impedance changes caused by the incident THz signals. Compared with the thermal biasing method, this method would be more promising in large scale array with simple readout. The used NbN HEB has an excellent performance as heterodyne detector with the double sideband noise temperature(T_N) of 403 K working at 4.2 K and 0.65 THz. As a result, the noise equivalent power of 1.5 pW/Hz~(1/2) and the response time of 64 ps are obtained for the direct detectors based on the NbN HEBs and working at 4.2 K and 0.65 THz.  相似文献   

6.
以商用高灵敏度红外探测器TPS434为研究对象,测量了其灵敏度随温度(280~10 K)、辐射的调制频率、磁场变化(0~6 T)的相关信息。从实验结果得到:TPS434的灵敏度随着温度降低而降低,随辐射的调制频率增加而衰减,但是低温下的衰减速率变缓,说明探测器的弛豫时间变短;热电堆的温差电动势在低温下会随磁场发生线性变化,可以通过线性拟合扣除磁场对测量结果的影响。由实验所得数据估算等效噪声功率NEP以及最小可检测功率Pmin,对TPS434作为THz探测器的可行性进行了分析。  相似文献   

7.
Akiba M  Fujiwara M 《Optics letters》2003,28(12):1010-1012
Noises associated with materials and devices in the readout circuits for a Si p-i-n photodiode have been measured. The dielectric polarization noise of the materials and devices near the gate circuit of the junction field-effect transistor used for the preamplifier determined the photodetection limits of photodiodes with a diameter smaller than several millimeters. We fabricated an ultralow-noise photodetection system, minimizing the polarization noise as much as possible. The readout noises of the system were 10 and 18 electrons in a correlated double sample for 0.1- and 1-mm-diameter Si p-i-n photodiodes at 77 K, respectively.  相似文献   

8.
Noise is an important theoretical constraint on the evolution of signal form and sensory performance. In order to determine environmental constraints on the communication of two freshwater gobies Padogobius martensii and Gobius nigricans, numerous noise spectra were measured from quiet areas and ones adjacent to waterfalls and rapids in two shallow stony streams. Propagation of goby sounds and waterfall noise was also measured. A quiet window around 100 Hz is present in many noise spectra from noisy locations. The window lies between two noise sources, a low-frequency one attributed to turbulence, and a high-frequency one (200-500 Hz) attributed to bubble noise from water breaking the surface. Ambient noise from a waterfall (frequencies below 1 kHz) attenuates as much as 30 dB between 1 and 2 m, after which values are variable without further attenuation (i.e., buried in the noise floor). Similarly, courtship sounds of P. martensii attenuate as much as 30 dB between 5 and 50 cm. Since gobies are known to court in noisy as well as quiet locations in these streams, their acoustic communication system (sounds and auditory system) must be able to cope with short-range propagation dictated by shallow depths and ambient noise in noisy locations.  相似文献   

9.
Single‐crystal diamond is a material with great potential for the fabrication of X‐ray photon beam‐position monitors with submicrometre spatial resolution. Low X‐ray absorption combined with radiation hardness and excellent thermal‐mechanical properties make possible beam‐transmissive diamond devices for monitoring synchrotron and free‐electron laser X‐ray beams. Tests were made using a white bending‐magnet synchrotron X‐ray beam at DESY to investigate the performance of a position‐sensitive diamond device using radiofrequency readout electronics. The device uniformity and position response were measured in a 25 µm collimated X‐ray beam with an I‐Tech Libera `Brilliance' system. This readout system was designed for position measurement and feedback control of the electron beam in the synchrotron storage ring, but, as shown here, it can also be used for accurate position readout of a quadrant‐electrode single‐crystal diamond sensor. The centre‐of‐gravity position of the F4 X‐ray beam at the DORIS III synchrotron was measured with the diamond signal output digitally sampled at a rate of 130 Msample s?1 by the Brilliance system. Narrow‐band filtering and digital averaging of the position signals resulted in a measured position noise below 50 nm (r.m.s.) for a 10 Hz bandwidth.  相似文献   

10.
The accuracy of the Shack-Hartmann wavefront sensor for measuring the wavefront distortion is mainly dependent upon the measuring accuracy of the centroid of each spot. A modified center detection algorithm, which uses some power from the photon events of each pixel instead of photon events themselves, is analyzed theoretically and the computer simulations are given. The results show that photon noise error and sampling error increases as the power value goes up; and to some powers, the readout noise and background noise error decrease. An experiment is described through which the optimum power can be obtained.  相似文献   

11.
A model is presented which calculates the intrinsic envelope power of a bandpass noise carrier within the passband of a hypothetical modulation filter tuned to a specific modulation frequency. Model predictions are compared to experimentally obtained amplitude modulation (AM) detection thresholds. In experiment 1, thresholds for modulation rates of 5, 25, and 100 Hz imposed on a bandpass Gaussian noise carrier with a fixed upper cutoff frequency of 6 kHz and a bandwidth in the range from 1 to 6000 Hz were obtained. In experiment 2, three noises with different spectra of the intrinsic fluctuations served as the carrier: Gaussian noise, multiplied noise, and low-noise noise. In each case, the carrier was spectrally centered at 5 kHz and had a bandwidth of 50 Hz. The AM detection thresholds were obtained for modulation frequencies of 10, 20, 30, 50, 70, and 100 Hz. The intrinsic envelope power of the carrier at the output of the modulation filter tuned to the signal modulation frequency appears to provide a good estimate for AM detection threshold. The results are compared with predictions on the basis of the more complex auditory processing model by Dau et al.  相似文献   

12.
Either an interaural phase shift or level difference was introduced to a narrow section of broadband noise in order to measure the acuity of the binaural system to segregate a narrowband from a broadband stimulus. Listeners were asked to indicate whether this dichotic noise or a totally diotic noise was presented in a single-interval procedure. Thresholds for interaural phase and level differences were estimated from four point psychometric functions. These thresholds were determined for three bandwidths of interaurally altered noise (2, 10, and 100 Hz) centered at four center frequencies (200, 500, 1000, and 1600 Hz). Thresholds were lowest when the interaurally altered band of noise was centered at 500 Hz, and thresholds increased as the bandwidth of the interaurally altered noise decreased. Performance did not exceed 75% correct when either an interaural phase shift (180 degrees) or interaural level difference (50 dB) was introduced to a 100 Hz band of noise centered at frequencies higher than 1600 Hz. In a second set of conditions, performance was measured when both an interaural phase shift and level difference were presented in a 10-Hz-wide band of noise centered at 500 Hz. A version of the Durlach E-C model was able to account for a great deal of the data. The results are discussed in terms of the Huggins dichotic pitch.  相似文献   

13.
The temporal resolution of the binaural auditory system was measured using a binaural analog of gap detection. A binaural "gap" was defined as a burst of interaurally uncorrelated noise (Nu) placed between two bursts of interaurally correlated noise (N0). The Nu burst creates a dip in the output of a binaural temporal window integrating interaural correlation, analogous to the dip created by a silent gap in the output of a monaural temporal window integrating intensity. The equivalent rectangular duration (ERD) of the binaural window was used as an index of binaural temporal resolution. In order to derive the ERD, both the shortest-detectable binaural gap and the jnd for a reduction in interaural correlation from unity were measured. In experiment 1, binaural-gap thresholds were measured using narrow-band noise carriers as a function of center frequency from 250 to 2000 Hz (fixed 100-Hz bandwidth) and a function of lower-cutoff frequency from 100 to 400 Hz (fixed 500-Hz upper-cutoff frequency). Binaural-gap thresholds (1) increased significantly with increasing frequency in both tasks, and (2) at frequencies below 500 Hz, were shorter than corresponding silent-gap thresholds measured with the same N0 noises. In experiment 2, interaural-correlation jnd's were measured for the same conditions. The jnd's also increased significantly with increasing frequency. The results were analyzed using a temporal window integrating the output of a computational model of binaural processing. The ERD of the window varied widely across listeners, with a mean value of 140 ms, and did not significantly depend on frequency. This duration is about an order of magnitude longer than the ERD of the monaural temporal window and is, therefore, consistent with "binaural sluggishness."  相似文献   

14.
A cold preamplifier based on superconducting quantum interference devices(SQUIDs)is currently the preferred readout technology for the low-noise transition edge sensor(TES).In this work,we have designed and fabricated a series SQUID array(SSA)amplifier for the TES detector readout circuit.In this SSA amplifier,each SQUID cell is composed of a first-order gradiometer formed using two equally large square washers,and an on-chip low pass filter(LPF)as a radiofrequency(RF)choke has been developed to reduce the Josephson oscillation interference between individual SQUID cells.In addition,a highly symmetric layout has been designed carefully to provide a fully consistent embedded electromagnetic environment and achieve coherent flux operation.The measured results show smooth V-Φcharacteristics and a swing voltage that increases linearly with increasing SQUID cell number N.A white flux noise level as low as 0.28μφ;/Hz;is achieved at 0.1 K,corresponding to a low current noise level of 7 pA/Hz;.We analyze the measured noise contribution at mK-scale temperatures and find that the dominant noise derives from a combination of the SSA intrinsic noise and the equivalent current noise of the room temperature electronics.  相似文献   

15.
An experiment was performed to study the interaction of two narrow-band noises having correlated temporal envelopes. The detection threshold of a 100-Hz-wide noise-band signal was measured at different center frequencies in the presence of a continuous 100-Hz-wide noise band having a center frequency of 1000 Hz. The two noise bands had either correlated or independent temporal envelopes. Measured signal detection thresholds are lower when the two noise bands are independent, but the magnitude of this difference is not a simple function of the frequency separation between the two noise bands.  相似文献   

16.
In this paper, boron-doped nanocrystalline Si0.78Ge0.22:H thin film is assessed for use as resistive sensing layer in uncooled infrared bolometer applications. The silicon germanium thin films were deposited by PECVD (plasma enhanced chemical vapor deposition) through decomposition of silane, germane and diborane diluted with argon at substrate temperature of 230 °C. Under optimum deposition parameters, the sensing films with modulate electrical resistivity (<104 Ω cm) and high temperature coefficient of resistance (TCR) (>−3%/K) were obtained at room temperature. 1/f noise character in the form of the normalized Hooge parameter was measured in the frequency range of 1–64 Hz, resulting in a lower 1/f noise compared to other materials currently used for device application.  相似文献   

17.
低频标准真空涨落的测量   总被引:1,自引:0,他引:1       下载免费PDF全文
薛佳  秦际良  张玉驰  李刚  张鹏飞  张天才  彭堃墀 《物理学报》2016,65(4):44211-044211
采用自平衡零拍方案, 对低频段的标准量子真空涨落进行了测量. 实验确定了该系统的饱和光功率约为3.2 mW. 在10 Hz–400 kHz的频率范围内, 系统的共模抑制比平均为55 dB, 在100 Hz处高达63 dB, 对激光经典技术噪声具有很强的抑制作用. 当入射光功率为400 μ W 时, 真空涨落噪声达到11 dB. 此低频量子真空噪声探测系统可广泛应用于量子计量和量子光学等研究领域.  相似文献   

18.
Psychometric functions for detecting increments or decrements in level of sinusoidal pedestals were measured for increment and decrement durations of 5, 10, 20, 50, 100, and 200 ms and for frequencies of 250, 1000, and 4000 Hz. The sinusoids were presented in background noise intended to mask spectral splatter. A three-interval, three-alternative procedure was used. The results indicated that, for increments, the detectability index d' was approximately proportional to delta I/I. For decrements, d' was approximately proportional to delta L. The slopes of the psychometric functions increased (indicating better performance) with increasing frequency for both increments and decrements. For increments, the slopes increased with increasing increment duration up to 200 ms at 250 and 1000 Hz, but at 4000 Hz they increased only up to 50 ms. For decrements, the slopes increased for durations up to 50 ms, and then remained roughly constant, for all frequencies. For a center frequency of 250 Hz, the slopes of the psychometric functions for increment detection increased with duration more rapidly than predicted by a "multiple-looks" hypothesis, i.e., more rapidly than the square root of duration, for durations up to 50 ms. For center frequencies of 1000 and 4000 Hz, the slopes increased less rapidly than predicted by a multiple-looks hypothesis, for durations greater than about 20 ms. The slopes of the psychometric functions for decrement detection increased with decrement duration at a rate slightly greater than the square root of duration, for durations up to 50 ms, at all three frequencies. For greater durations, the increase in slope was less than proportional to the square root of duration. The results were analyzed using a model incorporating a simulated auditory filter, a compressive nonlinearity, a sliding temporal integrator, and a decision device based on a template mechanism. The model took into account the effects of both the external noise and an assumed internal noise. The model was able to account for the major features of the data for both increment and decrement detection.  相似文献   

19.
This study sought to differentiate between the effect of stimulus bandwidth and the effect of number of activated auditory channels on gap detection in narrow bands of noise. The aim was to clarify the role of across-frequency analysis in temporal processing. Experiment 1 established that when total noise bandwidth is held constant at 100 Hz, gap detection improves as stimulus energy is distributed to both lower and higher frequencies. Experiment 2a showed that the effect was smaller, or was absent, when the cumulative stimulus bandwidth was increased from 100 to 200 Hz. Experiment 2b confirmed that the benefit of spectral dispersion for the narrower cumulative bandwidth also held for a higher frequency region. The results suggest that in conditions where the cumulative stimulus bandwidth is relatively narrow and, concomitantly, gap detection is relatively poor, there is an advantage in dispersing the stimulus across a number of auditory channels. The advantage for the distribution of energy across a range of auditory channels may be offset when the spectral spacing of bands exceeds a critical value.  相似文献   

20.
宋志军  吕昭征  董全  冯军雅  姬忠庆  金勇  吕力 《物理学报》2019,68(7):70702-070702
介观体系输运过程中载流子的离散性导致了散粒噪声.通过测量散粒噪声可以得到传统的基于时间平均值的电导测量无法得到的随时间涨落信息,因而作为一种重要手段在极低温量子输运研究中得到了一定的应用.极低温环境下的噪声测量是一种难度很大的极端条件下的微弱信号测量,通常需要在低温端安装前置放大器并且尽量靠近待测器件以提高测量信噪比和带宽,因此对放大器的噪声水平和功耗都有严格的要求.提出了在稀释制冷机内搭建的散粒噪声测量系统,以及利用此套系统得到了在mK温区超导隧道结散粒噪声的测量结果.自行研制的高电子迁移率晶体管低温前置放大器采用整体封装,便于安装在商用干式稀释制冷机的4 K温区,本底电压噪声为0.25 nV/√Hz,功耗仅为0.754 mW.通过对隧道结进行散粒噪声测量,得到的Fano因子和理论计算吻合.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号