首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An on-line immunoextraction and liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol in rat plasma. Sample preparation involved immunoextraction of analytes using an antibody raised against R,R'- and R,S'-aminofenoterol that was immobilized onto chromatographic support. LC was performed on a Waters hydrophilic interaction chromatography (HILIC) column (150 mm x 2.1mm), using an isocratic mobile phase of methanol:ammonium acetate (10mM, pH 6.8) (90:10, v/v) at a flow rate of 0.2 ml/min. The MS was operated in the single ion monitoring mode (m/z 304.2 for R,R'-fenoterol, m/z 318.1 for R,R'-methoxyfenoterol, and m/z 339.2 for R,S'-naphthylfenoterol). Optimization of analytes desorption process from the immunoextraction column was performed by factorial analysis and the sample calibration curves were made with spiked rat plasma samples containing 0.5-100 ng/ml of drugs. The cross-selectivity studies of the antibody were determined and the results suggested high selectivities toward R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol. The accuracy of assay was more than 96% while intra- and inter-day precision of assay were less than 12.4%. Stability studies (2h benchtop, freeze/thaw, and autosampler stability) were conducted and the analytes were stable through out studies. The validated method was used to determine the plasma concentration-time profiles of drugs after oral administration to rats of R,R'-fenoterol, R,R'-methoxyfenoterol and R,S'-naphthylfenoterol.  相似文献   

2.
A highly sensitive electrochemical sensor based on arenediazonium tosylates was designed to detect meldonium in urine. The effect of the concentration of ArN2+OTs arenediazonium tosylate modifier and various substituents was studied. Basic operating parameters for voltammetric meldonium detection were established and the procedure for urine sample preparation was developed. The following values were obtained: limit of detection (LOD) 0.005 mg ⋅ L−1 (P=0.95) and limit of quantification (LOQ) 0.01 mg ⋅ L−1. The relationship between the analytical signal and meldonium concentration in the solution ranging from 0.01 to 400 mg ⋅ L−1 was described by a linear function. The meldonium concentration error did not exceed 18 %. The analysis time for a single urine sample was reduced to 15 minutes.  相似文献   

3.
Status epilepticus (SE) is considered the second most frequent neurological emergency. Its therapeutic management is performed using sequential antiepileptic drug regimens. Diazepam (DIA), midazolam (MID), phenytoin (PHT) and phenobarbital (PB) are four drugs of different classes used sequentially in the management of SE. A sensitive, selective, accurate and precise method was developed and validated for simultaneous determination of the four antiepileptic drugs in human plasma. Their separation and quantification were achieved using ultra‐performance liquid chromatography (UPLC) with mass detection using carbamazepine as internal standard (IS). For the first three drugs and the IS, UPLC–MS/MS with electrospray ionization working in multiple reaction monitoring mode was used at the following transitions: m/z 285 → 193 for DIA; m/z 326 → 291 for MID; m/z 253 → 182 for PHT; and m/z 237 → 194, 237 → 192 for IS. For the fourth drug (PB), a molecular ion peak of PB [M + H] + at m/z 233 was used for its quantitation. The method was linear over concentration ranges 5–500 ng/mL for DIA and MID and 0.25–20 μg/mL for PHT and PB. Bioanalytical validation of the developed method was carried out according to European Medicines Agency guidelines. The developed method can be applied for routine drug analysis, therapeutic drug monitoring and bioequivalence studies.  相似文献   

4.
A simultaneous, selective, sensitive and rapid liquid chromatography/tandem mass spectrometry method was developed and validated for the quantification of gefitinib, erlotinib and afatinib in 250 μL samples of human blood plasma. Diluted plasma samples were extracted using a liquid‐phase extraction procedure with tert‐butyl methyl ether. The three drugs were separated by high‐performance liquid chromatography using a C18 column and an isocratic mobile phase running at a flow rate of 0.2 mL/min for 5 min. The drugs were detected using a tandem mass spectrometer with electrospray ionization using imatinib as an internal standard. Calibration curves were generated over the linear concentration range of 0.05–100 nm in plasma with a lower limit of quantification of 0.01 or 0.05 nm for all compounds. Finally, the validated method was applied to a clinical pharmacokinetic study in patients with nonsmall‐cell lung cancer (NSCLC) following the oral administration of afatinib. These results indicate that this method is suitable for assessing the risks and benefits of chemotherapy in patients with NSCLC and is useful for therapeutic drug monitoring for NSCLC treatment. As far as we know, this is the first report on LC‐MS/MS method for the simultaneous quantification of NSCLC tyrosine kinase inhibitor plasma concentrations including afatinib. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
Pharmaceuticals have become major targets in environmental chemistry due to their presence in aquatic environments (following incomplete removal in wastewater treatment or point-source contaminations), threat to drinking water sources and concern about their possible effects to wildlife and humans. Recently several methods have been developed for the determination of drugs and their metabolites in the lower nanogram per litre range, most of them using solid-phase extraction (SPE) or solid-phase microextraction (SPME), derivatisation and finally gas chromatography mass spectrometry (GC-MS), gas chromatography tandem mass spectrometry (GC-MS/MS) and liquid chromatography electrospray tandem mass spectrometry (LC-ES/MS/MS). Due to the elevated polarity of non-steroidal anti-inflamatory drugs (NSAIDs), analytical techniques based on either liquid chromatography coupled to mass spectrometry (LC-MS) and gas chromatography coupled to mass spectrometry (GC-MS) after a previous derivatisation step are essential. The most advanced aspects of current GC-MS, GC-MS/MS and LC-MS/MS methodologies for NSAID analysis are presented.  相似文献   

6.
Yunaconitine (YAC) is a toxic aconite alkaloid that is considered to be a hidden aconite poison since it is frequently found in body fluids from aconite poisoning patients, but has not been well studied in commonly used herbal drugs. In this paper, a rapid and sensitive ultra high‐performance liquid chromatography–tandem mass spectrometry (UHPLC‐MS/MS) detection combined with microwave‐assisted extraction (MAE) was developed for high throughput simultaneous determination of YAC and six other toxic aconite alkaloids in 31 samples of crude, processed aconites and aconite‐containing drugs. The optimized method showed excellent linearity, precision, accuracy and recovery for all target compounds with short run time. YAC was detected in some samples with contents from 0.015 to 10.41 mg/g. This is the first report on the determination of YAC in Radix Aconiti, Radix Aconiti Kusnezoffii and aconite‐containing drugs. This newly developed method facilitates the rapid screening of YAC and related toxic aconite alkaloids and allows YAC to be used as a chemical marker for the quality control of aconites and aconite‐containing drugs. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
A simple and highly sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) bioanalytical method was developed and fully validated for the first time for the simultaneous determination of newly discovered antiviral drugs, namely sofosbuvir (SOF) and daclatasvir (DAC) in human plasma. Tadalafil (TAD) was used as internal standard (IS). SOF, DAC and TAD (IS) were extracted from plasma using liquid–liquid extraction technique with methyl tert‐butyl ether. The chromatographic separation was carried out using ZorbaxSB‐C18 column (4.6 × 50 mm,5 μm) and 5 mm ammonium formate buffer (pH 3.5)–acetonitrile (50:50, v/v) as mobile phase in an isocratic elution mode pumped at a flow rate 0.7 mL min−1. The quantitation was performed on API4500 triple quadrupole tandem mass spectrometer with positive electrospray ionization interface in multiple reaction monitoring mode. Validation was applied according to US Food and Drug Administration guidelines for bio‐analytical methodswith respect to linearity, precision, accuracy, selectivity, carry‐over, stability and dilution integrity. Linearity was obtained over concentration ranges of 0.3–3000 and 3–3000 ng mL−1 for SOF and DAC, respectively, by applying a weighted least‐squares linear regression method (1/x2). The proposed method could be applied successfully in bioequivalence and/or clinical studies for therapeutic drug monitoring of patients undergoing dual combination therapy as the latter combination proved more efficacious and powerful tool for the complete treatment of hepatitis C genotype 3 within 16 weeks. The suggested method has been applied successfully to pharmacokinetic studies with excellent assay ruggedness and reproducibility.  相似文献   

8.
Therapeutic drug monitoring of antiepileptic drugs is widely practiced to achieve optimal efficacy and avoid adverse side effects. We describe an ultra‐high‐performance liquid chromatography tandem mass spectrometry (UHPLC/MS/MS) method developed for the monitoring of four frequently prescribed antiepileptic drugs – lamotrigine, levetiracetam, oxcarbazepine and topiramate. The main pharmacologically active metabolite of oxcarbazepine (mono‐hydroxy‐derivative metabolite, MHD) was also quantified. After addition of internal standards and a simple stage of protein precipitation, plasmatic samples were analyzed on a C18 column. All antiepileptic drugs were separated and quantified in 6 min, without interference. A good linearity was observed all over the calibration range (r2 > 0.99), up to 20 μg/mL (40 μg/mL for MHD). The limit of quantification was 0.20 μg/mL (0.40 μg/mL for MHD) with precision and accuracy ranging from 1.0 to 2.1% and from 96.7 to 110.8%, respectively. Intra‐ and inter‐day precision and accuracy values were within 15%. No significant matrix effect was observed for all analytes. Clinical application was successfully evaluated in 259 samples from patients treated for epilepsy or bipolar disorders. In conclusion, a rapid, specific and sensitive UHPLC/MS/MS method was developed and validated for simultaneous quantification of antiepileptic drugs, suitable for therapeutic drug monitoring in neurology and psychiatry.  相似文献   

9.
The present study was undertaken to investigate the pharmacokinetics of isoliquiritigenin (isoLQ) as determined by the automated dosing/blood sampling (ABS) and traditional manual blood sampling techniques in awake and freely moving mice using combined liquid chromatography tandem mass spectrometry. Pharmacokinetic comparison was conducted by allocating mice into two groups; an ABS group (intravenous study and oral studies, n = 5 each) and a manual group (intravenous and oral studies; n = 5 each). Significant differences in pharmacokinetic parameters (area under the curve and clearances) were observed between ABS and manual groups. This could be mainly due to the blood sampling site difference (via heart puncture in traditional manual group and via carotid artery in ABS groups). The low F of isoLQ could be mainly due to a considerable gastrointestinal and/or hepatic first‐pass effect and not to incomplete absorption. The driving force for distribution and elimination of drugs is its concentration in the arterial blood. Therefore, the ABS method was found to be a useful drug development tool for accelerating the process of preclinical in vivo studies and for obtaining reliable and accurate pharmacokinetic parameters in mice. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
11.
Streamlined quantitative metabolomics in central metabolism of bacteria would be greatly facilitated by a high-efficiency liquid chromatography (LC) method in conjunction with accurate quantitation. To achieve this goal, a methodology for LC-tandem quadrupole mass spectrometry (LC-MS/MS) involving a pentafluorophenylpropyl (PFPP) column and culture-derived global (13)C-labeled internal standards (I.Ss.) has been developed and compared to hydrophilic interaction liquid chromatography (HILIC)-MS/MS and published combined two-dimensional gas chromatography and LC methods. All 50 tested metabolite standards from 5 classes (amino acids, carboxylic acids, nucleotides, acyl-CoAs and sugar phosphates) displayed good chromatographic separation and sensitivity on the PFPP column. In addition, many important critical pairs such as isomers/isobars (e.g. isoleucine/leucine, methylsuccinic acid/ethylmalonic acid and malonyl-CoA/3-hydroxybutyryl-CoA) and metabolites of similar structure (e.g. malate/fumarate) were resolved better on the PFPP than on the HILIC column. Compared to only one (13)C-labeled I.S., the addition of global (13)C-labeled I.Ss. improved quantitative linearity and accuracy. PFPP-MS/MS with global (13)C-labeled I.Ss. allowed the absolute quantitation of 42 metabolite pool sizes in Methylobacterium extorquens AM1. A comparison of metabolite level changes published previously for ethylamine (C2) versus succinate (C4) cultures of M. extorquens AM1 indicated a good consistency with the data obtained by PFPP-MS/MS, suggesting this single approach has the capability of providing comprehensive metabolite profiling similar to the combination of methods. The more accurate quantification obtained by this method forms a fundamental basis for flux measurements and can be used for metabolism modeling in bacteria in future studies.  相似文献   

12.
A mixture of tiletamine, a dissociative anesthetic, and zolazepam, a minor tranquilizer, has been widely used as an anesthetic or an immobilizing agent in a variety of animal species. However, interestingly, their pharmacokinetic behaviors have been published only in polar bears and pigs. In this study, we introduce a sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for determining the two drugs in dog plasma. After simple protein precipitation with acetonitrile including midazolam (internal standard), the analytes were chromatographed on a reversed‐phase column with a mobile phase of 10 m m ammonium acetate aqueous solution and acetonitrile (1:4, v/v). The accuracy and precision of the assay were in accordance with FDA regulations for the validation of bioanalytical methods. This method was used to measure the concentrations of zolazepam and tiletamine in plasma after a single intramuscular 10 mg dose of each in beagle dogs. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
A fast and easy tailored dispersive solid‐phase extraction (d‐SPE) procedure has been developed for the determination of 13 cytostatic drugs. Combined with a rapid and simultaneous ultra performance liquid chromatography/tandem mass spectrometry method for residue identification and quantification in urine, it has been fully validated and tested to study a realistic situation in working environment. The target compounds were chosen from the most common classes used in hospitals. The d‐SPE adsorbent was obtained mixing Oasis HLB® with C18 and applied to a large volume of sample (10 mL). The electrospray ionization‐mass spectrometry acquisition was conducted in a mixed period mode: six acquisition windows were in positive ionization and one in negative (for 5‐fluorouracil). The lowest limit of quantification was found at 0.04 μg/L urine for methotrexate. The absolute recovery of cytotoxic drugs was assessed at two concentrations levels and ranged from 67.1% (cytarabine) to 102.3% (etoposide) and from 65.3% (cytarabine) to 101.2% (methotrexate) for the lower and higher levels, respectively, with the relative standard deviation always <12%. This method gives the opportunity to analyze drugs in a wide molecular weight range (from 130 to 853 a.m.u.) and in a complex matrix, such as urine, without losing any of the features that a method intended for trace quantification must have. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

14.
赵颖  刘瑜  金雁  徐宜宏  钟钰  蒋施  李晓东  曾凡  周健南 《色谱》2012,30(9):908-914
建立了同时测定配合饲料中喹诺酮类、磺胺类、大环内酯类和硝基呋喃类共计29种兽药的超高效液相色谱-电喷雾串联四极杆质谱(UPLC-ESI-MS/MS)检测方法。饲料样品用甲醇-乙腈(1:1, v/v)混合溶液提取,提取液经Oasis HLB固相萃取柱净化,采用UPLC-ESI-MS/MS检测。以甲醇和含0.1%(v/v)甲酸的水溶液作为流动相,进行梯度洗脱,用C18色谱柱分离,正离子模式扫描,多反应监测模式检测。29种兽药在0.01~5.0 mg/L范围内线性关系良好,相关系数(r)均大于0.99;在复合预混饲料、全价配合饲料、浓缩饲料中4个添加水平下29种兽药的平均回收率在61.2%~94.3%范围内,相对标准偏差(RSD)为2.2%~15.0%;方法的检出限(以信噪比大于10计)为0.01 mg/kg或0.05 mg/kg。该方法简便、快速、准确,重现性好,灵敏度高,适用于配合饲料中多种兽药的同时检测。  相似文献   

15.
We developed an ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method to determine four antibacterial drugs in human plasma for clinical usage. Samples were prepared using protein precipitation with methanol. Chromatographic separation was accomplished in 4.5 min on a BEH C18 column (2.1 × 50 mm, 1.7 μm) using a gradient elution of methanol and water (containing 7.71 g/L concentrated ammonium acetate, adjusted to pH 6.5 with acetic acid) at a flow rate of 0.4 mL/min. Positive electrospray was used for ionization. The method was linear in the concentration range 1–100 μg/mL for vancomycin, norvoncomycin, and meropenem; and 0.5–50 μg/mL for R-isomer of moxalactam and S-isomer of moxalactam. For all analytes, the intra- and inter-day accuracies and precisions were −8.47%–10.13% and less than 12%, respectively. The internal standard normalized recoveries and matrix effect were 62.72%–105.78% and 96.67%–114.20%, respectively. All analytes were stable at six storage conditions, with variations of less than 15.0%. The method was applied in three patients with central nervous system infection. The validated method might be useful for routine therapeutic drug monitoring and pharmacokinetic study.  相似文献   

16.
A rapid, simple and validated liquid chromatography coupled to tandem mass spectrometric method (LC-MS/MS) for topiramate analysis in human plasma has been applied to pharmacokinetic and bioequivalence studies in 24 healthy male Korean volunteers. The procedure involves a simple liquid extraction of topiramate and prednisone (internal standard) with acetonitrile and separation by HPLC equipped with a Capcell Pak C18 column using acetonitrile-0.1% triethylamine (80:20, v/v) as a mobile phase. Detection was carried out on an API 2000 MS system by multiple reactions monitoring mode. The ionization was optimized using ESI(-) and selectivity was achieved by MS/MS analysis, m/z 338.0 --> 77.5 and m/z 357.1 --> 327.2 for topiramate and prednisone, respectively. The method had a total run time of 2.5 min and showed good linearity over a working range of 20-5000 ng/mL in human plasma with a lower limit of quantification of 20 ng/mL. No metabolic compounds were found to interfere with the analysis. The inter-day and intra-day accuracy were in the ranges of 99.24-116.63 and 93.45-108.68%, respectively, and inter-day and intra-day precisions were below 6.24 and 5.25%, respectively. This method was successfully applied for pharmacokinetic and bioequivalence studies by analysis of blood samples taken up to 96 h after an oral administration of 100 mg of topiramate in 24 healthy Korean volunteers.  相似文献   

17.
Two new standard reference materials (SRM) for drugs of abuse in human hair have been developed. SRM 2379 consists of hair spiked with cocaine, benzoylecgonine, cocaethylene, phencyclidine, amphetamine, and methamphetamine. SRM 2380 consists of hair spiked with codeine, morphine, monoacetylmorphine, and tetrahydrocannabinol (THC). The SRMs were prepared by soaking the hair in a solution of the target analytes in water-dimethylsulfoxide. The concentration of each analyte was determined using two methods, one based upon gas chromatography/mass spectrometry (GC/MS) and one based upon liquid chromatography/mass spectrometry (LC/MS). Both methods used 0.1 M HCl for extraction of all the analytes from the hair, except for THC, which was extracted with 1 M NaOH. For isolation of the analytes from the extracts, the GC/MS-based methods used different clean-up procedures from those used for the LC/MS-based methods. The results from the two methods were in good agreement with mean differences for the analytes ranging from 4% to 16%. These materials will enable laboratories performing analyses of hair for drugs of abuse to test the accuracy of their methods.  相似文献   

18.
A simple LC‐MS/MS method was developed and validated for quantitatively analyzing six classes of 26 abused drugs and metabolites in human urine: (1) illicit drugs; (2) opiates; (3) synthetic opioids; (4) sedative; (5) stimulants; and (6) γ‐aminobutyric acid analogs. All urine samples were diluted with a mixture of isotope‐labeled internal standards, hydrolyzed with β‐glucuronidase and directly injected in a gradient chromatographic run. The mobile phase was composed of 0.1% formic acid in water and 0.1% of formic acid in methanol. A 4.9 min run time using the multiplexing driver and ultra‐biphenyl column (50 × 2.1 mm, 5 µm, RESTEK) allowed all drugs to have sufficient resolution in a short elute time. The overlapping liquid chromatography runs and scheduled multiple reaction monitoring acquisition method resulted in a higher overall throughput for the system. The result was linear over the studied range (2–16,000 ng/mL) for all compounds with correlation coefficients r2 ≥ 0.995. The intra‐day and inter‐day precisions and accuracies were within 15% and recovery was between 83 and 115% for all analytes. Freeze–thaw stability for three cycles and long‐term stability (57 days, ?20°C) were established for all analytes. The cross‐validation between College of American Pathologists and in‐house was validated (0.06% ≤ bias ≤ 12.3%). The applicability of the method was examined by analyzing urine samples from chronic pain patients (n = 610). Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
Diabetes is a major global health problem which requires new studies for its prevention and control. Scoparia dulcis , a herbal product, is widely used for treatment of diabetes. Recent studies demonstrate coixol as a potent and nontoxic insulin secretagog from S. dulcis . This study focuses on developing two quantitative methods of coixol in S. dulcis methanol‐based extracts. Quantification of coixol was performed using high‐performance liquid chromatography–tandem mass spectrometry (method 1) and high‐performance liquid chromatography–ultraviolet detection (method 2) with limits of detection of 0.26 and 11.6 pg/μL, respectively, and limits of quantification of 0.78 and 35.5 pg/μL, respectively. S. dulcis is rich in coixol content with values of 255.5 ± 2.1 mg/kg (method 1) and 220.4 ± 2.9 mg/kg (method 2). Excellent linearity with determination coefficients >0.999 was achieved for calibration curves from 10 to 7500 ng/mL (method 1) and from 175 to 7500 ng/mL (method 2). Good accuracy (bias < −8.6%) and precision (RSD < 8.5%) were obtained for both methods. Thus, they can be employed to analyze coixol in plant extracts and herbal formulations.  相似文献   

20.
A sensitive and efficient liquid chromatography tandem mass spectrometry method was developed and validated for the simultaneous determination of piperaquine (PQ) and its N ‐oxidated metabolite (PQ‐M) in plasma. A simple protein precipitation procedure was used for sample preparation. Adequate chromatographic retention was achieved on a C18 column under gradient elution with acetonitrile and 2 mm aqueous ammonium acetate containing 0.15% formic acid and 0.05% trifluoroacetic acid. A triple‐quadrupole mass spectrometer equipped with an electrospray source was set up in the positive ion mode and multiple reaction monitoring mode. The method was linear in the range of 2.0–400.0 ng/mL for PQ and 1.0–50.0 ng/mL for PQ‐M with suitable accuracy, precision and extraction recovery. The lower limits of detection (LLOD) were established at 0.4 and 0.2 ng/mL for PQ and PQ‐M, respectively, using 40 μL of plasma sample. The matrix effect was negligible under the current conditions. No effect was found for co‐administrated artemisinin drugs or hemolysis on the quantification of PQ and PQ‐M. Stability testing showed that two analytes remained stable under all relevant analytical conditions. The validated method was successfully applied to a pharmacokinetic study performed in rats after a single oral administration of PQ (60 mg/kg).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号