首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The separation and preconcentration of vanadium (IV) and vanadium (V) using Sephadex DEAE A-25 with Eriochrome Cyanine R has been studied, based on the preconcentration of vanadium (IV) in the first step and V(V) after reduction with ascorbic acid in the second step. Factors affecting the optimum fixation of the complex were investigated. The absorbance of the solid phase is measured directly at 563 nm for V(IV), at 585 nm for V(V) and at 750 nm for both. The proposed method provides a simple and specific procedure for the separation of vanadium in natural waters. The calibration graph is linear up to 150 ng/mL, with RSD of 4.7% for V(IV) and 4.0% for V(V). The detection limits are 1.6 and 1.4 ng/mL for V(IV) and V(V), respectively.  相似文献   

2.
An on-line separation, preconcentration and determination system for vanadium(IV) and vanadium(V) comprising inductively coupled plasma optical emission spectrometry (ICP-OES) coupled to a flow injection (FI) method with an ultrasonic nebulization (USN) system was studied. The vanadium species were retained on an Amberlite XAD-7 resin as a vanadium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (V-5-Br-PADAP) complex at pH 3.7. Enhanced selectivity was obtained with the combined use of the formation on-line of the complexes and 1,2-cyclohexanediaminetetraacetic acid (CDTA) as masking agent. The vanadium complexes were removed from the microcolumn with 25% v/v nitric acid. A sensitivity enhancement factor of 225 was obtained with respect to ICP-OES using pneumatic nebulization (15-fold for USN and 15-fold for the microcolumn). The detection limit for the preconcentration of 10 mL of aqueous solution was 19 ng L-1. The precision for 10 replicate determinations at the 5 micrograms L-1 V level was 2.3% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the separation and preconcentration system for vanadium species was linear with a correlation coefficient of 0.9992 at levels from near the detection limits up to at least 100 micrograms L-1. The method was successfully applied to the speciation of vanadium in river water samples.  相似文献   

3.
A new poly(epoxy-melamine) chelating resin is synthesized from epoxy resin and used for the preconcentration and separation of traces of Ru(III), Au(III), V(V) and Ti(IV) ions from sample solutions. The ions analyzed can be quantitatively enriched by the resin at a flow-rate of 2 mL/min at pH 4, and quantitatively desorbed with 10 mL of 1 mol/L HCl + 0.2 g CS(NH2)2 at a flow-rate of 1 mL/min with recoveries of over 97%. The chelating resin can be reused 7 times without obvious loss of efficiency. Thousand-fold excesses of coexistent ions caused little interference during the enrichment and determination steps. The RSDs for the determination of 50 ng/mL Ru(III) and Au(III), 5.0 ng/mL V(V) and Ti(IV) were in the range of 1.5–4.5%. The recoveries of added standards in a real sample solution are between 96% and 100%, and the results for the ions analyzed in a nickel alloy sample are in good agreement with their reported values. Received: 12 May 1997 / Revised: 1 September 1997 / Accepted: 9 October 1997  相似文献   

4.
A sensitive and simple method for low temperature electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV-ICP-OES) determination of V(IV) and V(V) after separation/preconcentration by a micro-column packed with immobilized thenoyltrifluoroacetone (TTA) on microcrystalline naphthalene has been developed. Thenoyltrifluoroacetone was used as both a chelating agent for micro-column separation/preconcentration and a chemical modifier for ETV-ICP-OES determination of vanadium. Both vanadium species could be trapped by micro-column at pH 4.0, and the vanadate (VO2+) ion could be collected selectively at pH 2.4. Solid material loaded with analyte in the micro-column was dissolved with 100 μL of acetone containing 2.0 mmol L−1 TTA and the vanadium was determined subsequently by ETV-ICP-OES. The concentration of vanadyl (VO2+) ion was calculated by subtracting the vanadate concentration from the total concentration of vanadium. Under the optimized experimental conditions, the detection limit (3σ) for the preconcentration of 5 mL of aqueous solution is 0.068 μg L−1 for both species and the relative standard deviations were 4.3% for vanadium(V) and 4.8% for vanadium(IV) (c=10 μg L−1, n=7), respectively. The method was applied successfully to the determination of vanadium(IV) and vanadium(V) in natural water samples.  相似文献   

5.
A method was developed for the chromatographic separation of V(V) and V(IV) based on the different sorption forces of these vanadium species in C18 columns in presence of KH-phthalate. The vanadium species were detected with a flame atomic absorption spectrometer with acetylene/N2O flame. The detection limits (3σ) of V(V) and V(IV) were 0.18 μg/mL and 0.15 μg/mL, respectively. The relative standard deviations (N = 5) are 4.2% and 3.4% for 20–20 μg/mL V(V) and V(IV), respectively. The sampling frequency is 75/h. Because of the special interaction occurring between phthalate and V(IV) on the C18 column and the acetylene/N2O flame atomic absorption detection, practically no interferences can be detected even in large inorganic matrix. Received: 20 February 1997 / Revised: 2 June 1997 / Accepted: 7 June 1997  相似文献   

6.
Tetrakis(4-carboxyphenyl)porphyrin (TCPP) has been loaded on aminopropyl-silica gel by physical adsorption and by direct immobilization through formation of an amide bond to obtain chelating sorbents. These sorbents have been studied for preconcentration and separation of vanadium prior to its determination by atomic absorption spectrometry. Several parameters, such as sorption capacity of the chelating resin, pH for retention of V(IV) and V(V), volume of sample and eluent, were evaluated. Both vanadium species sorbed on TCPP-modified resin could be eluted using 2 mol L(-1) nitric acid solution. The recovery values were > 94% and preconcentration factor of 160 was obtained. For speciation analysis, cyclohexane-1,2-diaminetetraacetic acid (CDTA) was added to the sample for complexation of vanadium(IV), which was not retained on the microcolumn. The proposed method was examined for reference standard materials (TM-25.2 and CAAS-3) as well as for river water samples.  相似文献   

7.
Nakano S  Sakamoto K  Takenobu A  Kawashima T 《Talanta》2002,58(6):1263-1270
A flow-injection chemiluminescent (CL) method is proposed for the successive determination of nanogram levels of vanadium(IV) and total vanadium. The method is based on the catalytic effect of vanadium(IV) on the oxidation of purpurogallin by periodate to produce light emission at 4 °C. The presence of hydrogen carbonate enhanced the light emission arising from the vanadium(IV)-catalyzed reaction. Since vanadium(V) did not catalyze the CL reaction of purpurogallin, vanadium(V) was determined after being reduced to vanadium(IV) by using an on-line silver-reducing column. Calibration curves for vanadium(IV) and (V) were linear in the range 0.1–10 ng ml−1 with sampling rate of about 50 h−1. The limit of detection for signal-to-noise ratio of 2 was 0.05 ng ml−1 and the relative standard deviations were 1.4 and 1.6% for ten determinations of 2.0 ng ml−1 vanadium(IV) and (V), respectively. Interferences from metal ions could be eliminated by the use of O,O′-bis(2-aminoethyl)ethyleneglycol- N,N,N′,N′-tetraacetic acid and diphosphate as masking agents. The proposed method was successfully applied to the determination of vanadium(IV) and total vanadium in fresh water samples.  相似文献   

8.
A new, simple, sensitive and selective catalytic method is developed for the determination of vanadium in natural and sea waters. The method is based on the catalytic effect of V(V) and/or V(IV) on the bromate oxidative-coupling reaction of metol with 2,3,4-trihydroxybenzoic acid (THBA). The reaction is followed spectrophotometrically by tracing the oxidation product at 380 and/or 570 nm after 5 min of mixing the reagents. The optimum reaction conditions are 6.4 x 10(-3) mol l-1 of metol, 2.0 x 10(-3) mol l-1 of THBA and 0.16 mol l-1 of bromate at 35 degrees C and in the presence of an activator-buffer solution of 1 x 10(-2) mol l-1 of tartrate (pH = 3.10). Following the recommended procedure, V(V) and/or V(IV) can be determined with linear calibration graphs up to 0.75 ng ml-1 and detection limits, based on the 3Sb criterion, of 0.008 and 0.018 ng ml-1 at 380 and 570 nm, respectively. The developed method was successfully applied, without any separation or preconcentration processes, to the determination of vanadium in natural and seawaters following the direct calibration and standard addition techniques, respectively.  相似文献   

9.
An RP-HPLC method for the separation and determination of aluminium(III), vanadium(V), iron(III), copper(II) and nickel(II) with CALKS (Chromazol KS) and PAR ([4-(2-pyridylazo)resorcinol]) chelating on a YWG-ODS column was developed. A mixture of methanol-tetrahydrofuran(THF)-water (60:5:35 v/v) containing 0.2 mol/L LiCl, 5 x 10(-5) mol/L CALKS, 5 x 10(-5) mol/L PAR and acetate buffer solution (pH 4.9) was selected as mobile phase. The method has high sensitivity, with the detection limits being 6 ng/mL for aluminium(III), 3.5 ng/mL for vanadium(V), 10.4 ng/mL for iron(III), 6.3 ng/mL for copper(II) and 8.7 ng/mL for nickel(II). It also has good selectivity, so that most foreign metal ions do not interfere under the optimum conditions. The method can be applied to the simultaneous determination of trace amounts of aluminium, vanadium, iron, copper and nickel in rice and flour samples.  相似文献   

10.
An analytical procedure has been developed for the separation of Cu(II), Ni(II), Co(II), Fe(II), Pd(II), Th(IV), V(IV), and determination of Fe(II), Co(II), Ni(II), and V(IV) by MEKC after chelation with bis(salicylaldehyde)tetramethylethylenediimine (H2SA2Ten). Uncoated fused silica capillary was used with an applied voltage of 30 kV with photo‐diode array detection at 228 nm. SDS was added as micellar medium at pH 8.2 with sodium tetraborate buffer (0.1 M). Linear calibrations were established within 0.015–1000 μg/mL of each element with LOD within 5–67 ng/mL. The method was applied for the determination of vanadium from crude oil and ore samples in the range 0.34–2.40 and 114.2–720.7 μg/g with RSD 1.7–3.8 and 0.98–2.30% (n = 3), respectively. Fe, Ni, and Co present in crude oil and ore samples were also determined with RSD 1.3–2.8, 1.1–4.1, and 1.2–3.5% (n = 3), respectively. The results were compared with that of supplier's specifications and atomic absorption spectrometry (AAS). Method was evaluated by standard addition technique.  相似文献   

11.
An on-column complexation method has been developed for the simultaneous determination of V(IV) and V(V). Vanadium species were chelated with aminopolycarboxylic acids to form anionic complexes which were separated by capillary zone electrophoresis (CZE) with direct UV detection. Ethylenediaminetetraacetic acid (EDTA), diethylenetriaminepentacetric acid (DTPA), nitrilotriacetic acid (NTA), and N-2-hydroxyethylethlendiaminetriacetric acid (HEDTA) were investigated as both ligand and running electrolyte. Of the ligands studied the complexes of EDTA with V(IV) and V(V) resulted in the highest selectivity and UV response.The conditions used for on-column complexation and separation, including pH, and electrolyte ligand concentration, were examined to achieve reasonable separation selectivity and detection sensitivity. The optimum separation of the anionic forms of V(IV) and V(V) was obtained by use of CZE with UV detection at 185 nm and an electrolyte containing 5 mmol L(-1) EDTA at pH 4.0. Linear calibration plots were obtained in the concentration range10-300 micro mol L(-1); detection limits were 3 micro mol L(-1) for V(IV) and 1 micro mol L(-1) for V(V). The proposed method was demonstrated for the determination of vanadium in groundwater spiked with V(IV) and V(V).  相似文献   

12.
The optimum conditions for the formation of complexes of vanadium(IV) with Chrome Azurol S (CAS) in the presence of cationic (benzyldodecyldimethylammonium bromide (ST)) and non-ionic (Triton X-100, Tween 20 and Brij 35) surfactants have been determined. The complexes are formed in weakly acid solution (optimum pH: 4.6, 4.0 and 3.9) and show the absorption maxima at 603, 600 and 598 nm, respectively. The highest sensitivity was obtained for the method based on quaternary system V(IV)-CAS-ST-Triton X-100 due to the higher CAS: V(IV) molar ratio in this complex than in binary and ternary complexes: V(IV)-CAS) and V(IV)-CAS-ST. The molar absorptivity of this system is 8.08 × 104 L/mol cm. The LOD and LOQ values are: 0.006 and 0.02 μg/mL, respectively. Beer’s law is obeyed in the range: 0.02–0.60 μg/mL of V. The precision (RSD = 0.51%) and accuracy (1.9%) are satisfactory. This method has been applied to the determination of vanadium in plant materials.  相似文献   

13.
A sensitive kinetic spectrophotometric method has been developed for the determination of Se(IV) over the range of 45 to 4000 ng in 10 mL of solution. The method is based on the catalytic effect of Se(IV) on the reduction reaction of bromate by hydrazinium dichloride, with subsequent reaction of Ponceau S with products of the above reaction (chlorine and bromine), causing color changing of Ponceau S. Method development includes optimization of time interval for measurement of slope, pH, reagents concentration, and temperature. The optimized conditions yielded a theoretical detection limit of 33 ng/?10 mL of solution of Se(IV). The interfering effects were studied and removed. The method was applied to the determination of selenium in spiked water, Kjeldahl tablet, selenium tablet, and shampoo. Vanadium(V) has an inhibition effect on the catalyzed reaction of bromate and hydrazine by selenium. Using this effect, V(V) can be determined in the range of 70 to 2500 ng in 10 mL of solution. The optimization procedure includes pH and selenium concentration. An extraction method was used for interference removal. The method was applied to the determination of vanadium in petroleum. Received: 20 October 1998 / Revised: 17 April 1999 / Accepted: 3 June 1999  相似文献   

14.
A spectrophotometric determination of vanadium as vanadium(IV) pyridine thiocyanate is described. The blue complex is formed in acidic aqueous solution and extracted into pyridine-chloroform. Absorbance is measured at 7.40 mμ. The range of best accuracy for 1-cm cells is from about 80 to 240 μg of vanadium per ml, and sensitivity is 0.4 μg of vanadium per cm2 at 7.40 mμ. The vanadium may be present initially as vanadium(IV) or vanadium(V), which is reduced to vanadium(IV) by the large excess of thiocyanate ion added. Several elements interfere in the determination ; a separation procedure involving mercury cathode electrolysis is suggested.  相似文献   

15.
在酸性介质条件下,钒(Ⅳ)能显著催化溴酸钾对二甲酚橙的氧化褪色反应。据此建立了测定痕量钒(Ⅳ)的顺序注射催化光度法。方法的线性范围为0.5~50ng/mL、检出限为0.4ng/mL。对10ng/mL的钒(Ⅳ)连续11次测定的相对标准偏差为1.1%。用于环境水样中痕量钒(Ⅳ)的测定,加标回收率为91%~108%。  相似文献   

16.
A new poly(epoxy-melamine) chelating resin is synthesized from epoxy resin and used for the preconcentration and separation of traces of Ru(III), Au(III), V(V) and Ti(IV) ions from sample solutions. The ions analyzed can be quantitatively enriched by the resin at a flow-rate of 2 mL/min at pH 4, and quantitatively desorbed with 10 mL of 1 mol/L HCl + 0.2 g CS(NH2)2 at a flow-rate of 1 mL/min with recoveries of over 97%. The chelating resin can be reused 7 times without obvious loss of efficiency. Thousand-fold excesses of coexistent ions caused little interference during the enrichment and determination steps. The RSDs for the determination of 50 ng/mL Ru(III) and Au(III), 5.0 ng/mL V(V) and Ti(IV) were in the range of 1.5–4.5%. The recoveries of added standards in a real sample solution are between 96% and 100%, and the results for the ions analyzed in a nickel alloy sample are in good agreement with their reported values.  相似文献   

17.
Rostampour L  Taher MA 《Talanta》2008,75(5):1279-1283
Natural clinoptilolite was used as a sorbent material for solid phase extraction and preconcentration of vanadium. The clinoptilolite was first saturated with a cation such as nickel(II) and then modified with benzyldimethyltetradecyleammonium chloride (BDTA) for increasing sorption of 4-(2-pyridylazo)resorcinol (PAR). Vanadium–PAR complex was quantitatively retained on the sorbent by the column method at the pH range 6.2–7.0 at a flow rate of 1 mL min−1. It was removed from the column with 5.0 mL of dimethylformamide solution at a flow rate of 0.8 mL min−1 and determined by UV–vis spectrophotometry at λmax = 550 nm. 0.031 μg of vanadium can be concentrated from 450 mL of aqueous sample (where detection limit as 0.07 ng mL−1 with preconcentration factor of 90). Relative standard deviation for eight replicate determination of 5.0 μg of vanadium in final solution is 2.1%. The interference of number of anions and cations has been studied in detail to optimize the conditions and method was successfully applied for determination of all vanadium as V(IV) form in standard samples.  相似文献   

18.
A selective and precise spectrophotometric determination of vanadium(V) is performed after preceding extraction with N-benzoyl-N-phenylhydroxylamine (BPHA). The color is developed in a water-ethanol solution with hydrogen peroxide and 2-(5-chloro-2-pyridylazo)-5-dimethylaminophenol (5-Cl-DMPAP). The molar absorptivity at 588 nm is (6.57 ± 0.05) × 104 L mol–1 cm–1 at pH 2.1. The method permits the determination of vanadium (V) at trace levels in the presence of large amounts of other ions. It is applied to the determination of vanadium in aluminium (analytical reagent grade) and in human hair. High accuracy and precision is obtained. Received: 18 April 1997 / Revised: 20 June 1997 / Accepted: 25 June 1997  相似文献   

19.
In the present paper, a simple and sensitive method is proposed for vanadium(IV) determination in the presence of vanadium(V). This is based on the oxidation of vanadium(IV) present in the sample to vanadium(V) by addition of iron(III) cation, followed by a complexation reaction of iron(II) with the spectrophotometric reagent 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Br-PADAP). The iron(II) reacts with Br-PADAP immediately, forming a stable complex with a large molar absorptivity. The vanadium(IV) determination is possible, with a calibration sensitivity of 0.549 g ml–1, for an analytical curve of 18.8 ng ml–1 to 2.40 g ml–1, molar absorptivity of 2.80 × 104 1 mole–1 cm–1 and a detection limit of 5.5 ng ml–1. Selectivity was increased with the use of EDTA as a masking agent. The proposed method was applied for the vanadium(IV) determination in the presence of several amounts of vanadium(V). The results revealed that 200 g of vanadium(V) do not interfere with determination of 5.00 g of vanadium(IV). The precision and the accuracy obtained were satisfactory (R. S. D.<2%).  相似文献   

20.
A method was developed for the chromatographic separation of V(V) and V(IV) based on the different sorption forces of these vanadium species in C18 columns in presence of KH-phthalate. The vanadium species were detected with a flame atomic absorption spectrometer with acetylene/N2O flame. The detection limits (3σ) of V(V) and V(IV) were 0.18 μg/mL and 0.15 μg/mL, respectively. The relative standard deviations (N = 5) are 4.2% and 3.4% for 20–20 μg/mL V(V) and V(IV), respectively. The sampling frequency is 75/h. Because of the special interaction occurring between phthalate and V(IV) on the C18 column and the acetylene/N2O flame atomic absorption detection, practically no interferences can be detected even in large inorganic matrix.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号