首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 63 毫秒
1.
Phosphorus is an essential element for plants and animals, playing a fundamental role in the production of biochemical energy. Despite its relevance, phosphorus is not commonly determined by instrumental neutron activation analysis (INAA), because 32P does not emit gamma-rays in its decay. There are alternative methods for the determination of phosphorus by INAA, such as the use of beta counting or the measurement of bremsstrahlung originated from the high energy beta particle from 32P. Here the determination of phosphorus in plant materials by measuring the bremsstrahlung production was further investigated, to optimize an analytical protocol for minimizing interferences and overcoming the poor specificity. Eight certified reference materials of plant matrices with phosphorus ranging between 171 and 5,180 mg kg−1 were irradiated at a thermal neutron flux of 9.5 × 1012 cm−2 s−1 and measured with a HPGe detector at decay times varying from 7 to 60 days. Phosphorus solutions added to a certified reference material at three levels were used for calibration. Counts accumulated in the baseline at four different regions of the gamma-ray spectra were tested for the determination of phosphorus, with better results for the 100 keV region. The Compton scattering contribution in the selected range was discounted using an experimental peak-to-Compton factor and the net areas of all peaks in the spectra with energies higher than 218 keV, i.e. Compton edge above 100 keV. Amongst the interferences investigated, the production of 32P from sulfur, and the contribution of Compton scattering should be considered for producing good results.  相似文献   

2.
In order to determine traces of boron, silicon and sulfur, B(18O, x)27Mg, Si(18O, x)43Sc and S(18O, x)47V reactions have been investigated between 15 and 44MeV. At 34 MeV, only a few of the systematically identified nuclear interferences produce27Mg and the detection limit is 30ng boron for a 10 minute irradiation with a 0.3μA·cm−2 oxygen-18 beam. Silicon analysis has shown nuclear interferences from Al, P and K; interference-free detection limit is 80 ng silicon for an hour irradiation with a 0.4 μA·cm−2 beam at 39 MeV. There is no nuclear interference for the sulfur determination and the detection limit is 5 ng sulfur for a 30 minutes irradiation with a 0.5 μA·cm−2 beam at 39 MeV. Thus a selective and sensitive sulfur determination can be achieved.  相似文献   

3.
The determination of gold is based on the photoexcitation reaction 197Au(γ,γ’)197mAu with the half-life of 7.73 seconds and energy of emitted gamma-rays of 279 keV. Three 100 ml aliquots of coarsely ground Au-ore (grains <2 mm) corresponding to ca. 150–180 g were irradiated for 20 seconds with bremsstrahlung of maximum energy 10 MeV produced by a microtron at the electron beam current of 30–40 μA, 1–10 times reactivation was applied. After 3 seconds of decay, samples were measured for 20 seconds using scintillation or semiconductor gamma-spectrometry with the detection limits for an ideal sample down to 0.5 μg·g−1 and 0.1–0.2 μg·g−1 of Au, respectively. Content of U and Th undergoing photo-fission increases the detection limits several times.  相似文献   

4.
A novel purge-and-trap method coupled with gas chromatography-mass spectrometry (GC-MS) is developed for the analysis of trace and ultratrace phenols based on their derivatization with acetic anhydride. Parameters affecting the extraction efficiency, such as purge temperature, concentration of sodium chloride, purge time, and volume of derivatization reagent, were investigated. The optimized conditions were addition of 150 μL acetic anhydride, purge time of 25 min at the purge temperature of 60 °C with 30% NaCl. The linear range was 0.2–100 μg L−1 for phenols. The limits of detection (LODs) ranged from 0.08 to 0.15 μg L−1 and the relative standard deviations (RSDs) for most of the phenols at the 10 μg L−1level were below 10%. Natural water samples collected from a pool were successfully analyzed using the proposed method. The recovery of spiked water samples was 72.9–84.2%.  相似文献   

5.
A procedure for the determination of chromium in blood has been developed with a sensitivity of 5×10−3 μg Cr. Dried blood was irradiated with a neutron flux of 1012 n·cm−2·sec−1 in the VVRS reactor for 4 weeks, then the sample was mineralized and the chromium isolated by extraction as perchromic acid. The determination of the chromium content was accomplished by measuring the 0.32 MeV gamma energy of51Cr. In order to make correction for the interfering reaction54Fe(n,α)51Cr, the formation of chromium from high-purity iron was investigated. The chromium content of the blood samples was between 1.03×10−2 and 5.2×10−2 ppm Cr.  相似文献   

6.
The analytical procedure for the determination of sulfur in copper by activation with thermal neutrons is given. The purifications necessary to obtain a radiochemically pure precipitate of baryum sulphate are described. The occurrence of some discrepant values in the determinations led to the observation, for the first time, of abnormally high contents of35S* at a relatively important depth in the samples of irradiated copper (as deep as about 300 μ). Therefore it is necessary to etch the samples to a depth of 300 μ at least on each surface, before doing the chemical separations. Owing to the great influence of the reaction35Cl(n,p)35S*, the determination of sulfur by thermal neutrons is only possible at contents higher than 10−6, even if the chlorine concentration is very low (2·10−8 Cl introduces a correction in terms of sulfur of the order of 10−6). For sulfur contents lower than 10−6, the determination is made by irradiation in fast neutrons. The analytical procedure is described and the corrections in the presence of phosphorus and chlorine are discussed. At contents of the order of 10−8, the corrections are very small and the determination of some 10−7 of sulfur is easy. Finally, the determination of phosphorus in copper by activation in thermal neutrons is given. The chemical separations are the same as in the preceding case. Contents of the order of 10−8 phosphorus are determined without difficulty. The results of the determination of sulfur and phosphorus in many samples of copper are indicated: OFHC copper, High Purity copper (99.999%) and different samples of zone refined copper prepared at the Vitry’s Laboratory.   相似文献   

7.
A procedure has been developed for the detection of gunpowder residues deposited on the hand of a person firing a gun. The method is based on neutron activation analysis of the antimony level on the surface of the hand. The surface materials are removed by a film made by spraying a 4% solution of cellulose acetate in acetone, which sets to form a thin film that can readily be stripped off. This technique was found to be preferable to the paraffin-lift technique which is in common use. Following neutron activation of the film in a nuclear reactor, antimony is assayed by high-resolution Ge(Li) spectrometry without prior chemical processing. The sensitivity of the method is about 5·10−9 g Sb, with a precision of about ±10% at a neutron flux of 5·1013 n·cm−2·sec−1. Analysis of twenty samples taken from the hands of persons who had fired a pistol gave Sb levels of 0.4±0.2 μg, compared with 0.024±0.013 μg found on the hands of persons who had not fired a revolver. The possible extension of the present technique to include the determination of additional elements is discussed. Project carried out with the support of the Office of the Chief Scientist to the Ministry of Defense and with the collaboration of the Israel Police.  相似文献   

8.
A simple and fast flow injection fluorescence quenching method for the determination of iron in water has been developed. Fluorimetric determination is based on the measurement of the quenching effect of iron on salicylic acid fluorescence. An emission peak of salicylic acid in aqueous solution occurs at 409 nm with excitation at 299 nm. The carrier solution used was 2 × 10−6 mol L−1 salicylic acid in 0.1 mol L−1 NH4+/NH3 buffer solution at pH 8.5. Linear calibration was obtained for 5–100 μg L−1 iron(III) and the relative standard deviation was 1.25 % (n = 5) for a 20 μL injection volume iron(III). The limit of detection was 0.3 μg L−1 and the sampling rate was 60 h−1. The effect of interferences from various metals and anions commonly present in water was also studied. The method was successfully applied to the determination of low levels of iron in real samples (river, sea, and spring waters).  相似文献   

9.
Photonuclear activation and high resolution gamma spectrometry have been used to determine nondestructively 28 trace elements in coal. The samples and synthetic multielement standards were simultaneously irradiated in the bremsstrahlung beam at 18 and 30 MeV maximum energies. Taking into account the contribution of the main possible interferences, limits of detection between 0.2 and 125 μg·g−1 were obtained.

Stagiaire Etranger au C. E. A.  相似文献   

10.
The energy-dependent range of charged particles in activation analysis according to the reaction12C(d,n)13N permits the method to be applied to carbon determination in model epitaxial layers of sufficient thickness. We investigated 100 μm epitaxial layers of the n-type and undoped 50 μ layers as to p Czochralski substrates. Deuterons were slowed down with Cu and Ta foils having a limiting energy of 13.5 MeV, to 4.2 MeV and 2.9 MeV, respectively. In the resulting activation depths of 52 and 102 μm, the sensitivity of the method, which is 3·1014 at ·cm−3C at Ed=10 MeV in silicon, is reduced to 25% and 10%, respectively. An optimal flux of 0.9 μA·cm−2 was maintained. After irradiation, 20 or 10 μm were etched off. The sample was inductively fused at 1500 K in a Pb3O4/B2O3 mixture.13N was passed with He as carrier gas into an absorption vessel kept at 77 K, and its activity was measured in γ, γ-coincidence.  相似文献   

11.
The development of a spectrophotometric method for the determination of hydrogen peroxide in uranyl nitrate solutions is reported. The method involves the measurement of the absorbance at 520 nm of a vanadyl peroxide species. This species was formed by the addition of a reagent consisting of vanadium (V) (50 mmol·dm−3) in dilute sulphuric acid (2 mol·dm−3 H2SO4). This reagent, after dilution, was also used as an extractant for organic phase samples. The method is simple and robust and tolerant of nitric acid and U(VI). Specificity and accuracy were improved by the application of solid phase extraction techniques to remove entrained organic solvents and Pu(IV). Reverse phase solid phase extraction was used to clean-up aqueous samples or extracts which were contaminated with entrained solvent. A solid phase extraction system based upon an extraction chromatography system was used to remove Pu(IV). Detection limits of 26 μmol·dm−3 (0.88 μg·cm−3) or 7 μmol·dm−3 (0.24 μg·cm−3) for, respectively, a 1 and 4 cm path length cell were obtained. Precisions of RSD=1.4% and 19.5% were obtained at the extremes of the calibration curve (5 mmol·dm−3 and 50 μmol·dm−3 H2O2, 1 cm cell). The introduction of the extraction and clean-up stages had a negligible effect upon the precision of the determination. The stability of an organic phase sample was tested and no loss of analyte could be discerned over a period of at least 5 days. The presence of trace levels of reductants interfered with the determination, e.g., hydrazine (<2 mmol·dm−3), but this effect was ameliorated by increasing the concentration of the colormetric reagent.  相似文献   

12.
An activation analysis method has been developed for the determination of chromium and zinc in biological material. After the samples had been activated in a thermal flux of 7·1011 n·cm−2·sec−1 for 100 hours, both elements were separated from interfering radionuclides by means of ion-exchange and distillation processes. Gamma spectrometry was used to measure the activities of51Cr and65Zn. The practical limits of detection were found to be 1·10−8 g for chromium and 1·10−7 g for zinc. The results of model experiments and of the analysis of blood taken from two individuals proved to be accurate and reproducible.   相似文献   

13.
A combined solvent extraction—liquid scintillation method is suggested for the determination of plutonium. The quenching by twenty four extracting reagents was examined systematically, and the organo phosphorus extractants such as tributylphosphate (TBP), bis-(2-ethyhexyl) phosphoric acid (HDEHP), and tri-n-octylphosphineoxide (TOPO) were shown to be least quenching compared with amines and beta-diketones. Using TOPO, plutonium from 1 ng to 2 μg was determined within 5% of standard deviation, and the detection limit was 3·10−10 g of239Pu. The quenching by the different ions and the effects of the radioactive elements were also shown.  相似文献   

14.
A rapid, accurate, and precise method is described for the determination of Pb in wine using continuous-flow hydride generation atomic fluorescence spectrometry (CF-HGAFS). Sample pretreatment consists of ten-fold dilution of wine followed by direct plumbane generation in the presence of 0.1 mol L−1 HCl and 1% m/v K3[Fe(CN)6] with 1% m/v NaBH4 as reducing agent. An aqueous standard calibration curve is recommended for Pb quantification in wine sample. The method provides a limit of detection and a limit of quantification of 0.3 μg L−1 and 1 μg L−1, respectively. The relative standard deviation varies between 2–6% (within-run) and 4–11% (between-run) at 3–30 μg L−1 Pb levels in wine. Good agreement has been demonstrated between results obtained by CF-HGAFS and direct electrothermal atomic absorption spectrometry in analyses of red and white wines within the concentration range of 9.2–25.8 μg L−1 Pb.  相似文献   

15.
In soil science (ca. 1970), bromide ion (Br) in various forms (e.g., KBr, NaBr, SrBr2) was introduced as a non-reactive stable tracer in solute transport studies normally moving freely with the flux of water without substantial chemical or physical interactions with the soil. Typically, Br is extracted from soil and quantified using either a bromide selective electrode (sensitivity is ≈10μg/ml) or by high-performance liquid chromatography (sensitivity is ≈0.010 μg/ml). Where the sensitivity is adequate, the selective conductivity method, which is simple, affordable and fast, is preferred. More recently (ca. 1990), workers have reported that 20% of Br tracers, at low groundwater pH, may be adsorbed by iron oxides and kaolinite when present in the alluvial aquifer. We investigated the use of Epithermal Neutron Activation Analysis (ENAA) as a means of measuring Br directly in soil samples without an extraction. ENAA was chosen because of its high theoretical advantage factor over aluminum (i.e. ≈20), the principal interfering soil constituent, calculated for the79Br(n,γ)80Br reaction compared to27Al(n, γ)28Al. Br was measured (sensitivity is ≈0.050 μg/g) in one gram soil samples from a 5 s irradiation (φepi=2.5·1012 n·cm-2·s-1) using a BN capsule.  相似文献   

16.
Barium is estimated in biological material by thermal neutron activation analysis and measurement of139Ba by γ-counting. The biological material is digested with nitric acid and scavenged with ferric hydroxide. A special fluoride precipitation removes calcium and strontium and the barium is recovered as the chromate. The method allows the analysis of up to 40 samples per day and the sensitivity is 0.1 μg after irradiation for 85 mins at 4·1012n·cm−2·sec−1.  相似文献   

17.
A headspace solid-phase microextraction gas-chromatographic (HS-SPME-GC) procedure was used to determine the composition of the volatile fraction of white wine samples from several Spanish certified brands of origin (CBO). The compounds present were previously identified by gas chromatography−mass spectrometry (GC−MS) and quantitative determinations were carried out by GC-FID. Four CBO, Rueda, Ribeiro, Penedés, and Condado de Huelva, were studied. Rueda wines present the highest concentrations of ethyl acetate (55.86−125.27 μg mL−1), isoamyl acetate (0.91−6.72 μg mL−1), hexyl acetate (0.09−0.81 μg g mL−1), and 2-phenethyl acetate (0.14−0.66 μg mL−1). Compounds such as ethyl hexanoate (0.88−2.15 μg mL−1) and ethyl decanoate (0.29−0.96 μg mL−1) appeared in higher concentration in Ribeiro, Rueda, and Penedés samples. According to the results obtained and by applying pattern-recognition procedures differentiation of the considered CBO was attained. Principal-component analysis (PCA), linear discriminant analysis (LDA), and multilayer perceptrons neural networks (MLP-NN) were used as chemometric tools for pattern-recognition studies. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

18.
Irradiation and post-irradiation losses in 7 crude oils encapsulated in polyethylene and irradiated in a flux of 1012n·cm−2 sec−1 have been thoroughly studied. The fraction of mercury released during irradiations ranging from 10 minutes to 2 hours is proportional to the integrated flux received by the samples and does not differ substantially from one oil to another. Post-irradiation loss rates at 20°C range between 0.017 and 0.027%·hr−1. Storage at−20°C reduces them by at least a factor of 2. The influence on the activity of197Hg due to losses in sample weight occuring during the post-irradiation period has been examined. The fraction of radiomercury retained inside the walls of the irradiation vials versus the irradiation time has been assessed. Contamination of an inner irradiation site following prolonged irradiations of oils containing 150 μg/g of this element has been evaluated and found to have a negligible impact for trace measurements above the ng/g level.  相似文献   

19.
The Intercomparison Studies Program (ISP) at the Oak Ridge National Laboratory (ORNL, Oak Ridge, TN, USA) provides natural-matrix urine quality-assurance/quality-control (QA/QC) samples to radiobioassay analysis laboratories. In 2003, a single laboratory (Los Alamos National Laboratory LANL, Los Alamos NM USA) requested a change in the test-samples provided previously by the ISP. The change was requested to evaluate measurement performance for analyses conducted using thermal-ionization mass spectrometry (TIMS). Radionuclides included 239Pu at two activity levels (75–150 μBq·sample−1 and 1200–1600 μBq·sample−1) and 238Pu (3700–7400 μBq·sample−1). In addition, 240Pu was added to the samples so that the 239+240Pu specific activity was 3700–7400 μBq·sample−1. In this paper, the results of testing during the period May, 2003 through September, 2005 are presented and discussed.  相似文献   

20.
Summary A simple and sensitive method for the determination of trace amounts of bisphenol-A (BPA), bisphenol-A diglycidyl dimethacrylate (bis-GMA), bisphenol-A dimethacrylate (bis-DMA) and triethyleneglycol dimethacrylate (TEGDMA) in human saliva is proposed. These materials are used in dental restorations, as composites and sealants, and are sometimes detected in human saliva after dental treatment. The proposed method involves protein precipitation using acetonitrile followed by acidification, evaporation of the solvent and dissolution with dichloromethane prior to injection into a GC-MS. Thermal derivatization in the injection system was used for the identification and quantification of bis-GMA. Clean-up is not necessary using SIM mode. Bisphenol-F (BPF) was used as internal standard. The linear range was 15 to 1000 μg·L−1 for BPA, 50 to 10 000 μg·L−1 for bis-GMA, 50 to 1000 μg·L−1 for bis-DMA and 1 to 100 μg·L−1 for TEGDMA. The detection limits were 3,15,10 and 0.3 μg·L−1 for BPA, bis-GMA, bis-DMA and TEGD-MA, respectively. Validation of the proposed method was carried out by using the standard addition methodology. Samples of 10 mL of human saliva collected 1 h after dental treatment were analysed in order to assess the applicability of the method to detect and quantify such compounds originated from methacrylic resins used in odontological treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号