首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A multilaboratory study was conducted to compare the VIDAS LIS immunoassay with the standard cultural methods for the detection of Listeria in foods using an enrichment modification of AOAC Official Method 999.06. The modified enrichment protocol was implemented to harmonize the VIDAS LIS assay with the VIDAS LMO2 assay. Five food types--brie cheese, vanilla ice cream, frozen green beans, frozen raw tilapia fish, and cooked roast beef--at 3 inoculation levels, were analyzed by each method. A total of 15 laboratories representing government and industry participated. In this study, 1206 test portions were tested, of which 1170 were used in the statistical analysis. There were 433 positive by the VIDAS LIS assay and 396 positive by the standard culture methods. A Chi-square analysis of each of the 5 food types, at the 3 inoculation levels tested, was performed. The resulting average Chi square analysis, 0.42, indicated that, overall, there are no statistical differences between the VIDAS LIS assay and the standard methods at the 5% level of significance.  相似文献   

2.
A rapid and reliable analytical method was developed to detect and confirm the presence of Listeria monocytogenes in raw and partially processed foods. Forty-nine food samples (25 mixed cut vegetable salad, 12 smoked salmon, and 12 sterile smoked salmon) were individually inoculated with high levels [10-100 colony forming units (cfu)/25 g sample] and low levels (1-10 cfu/25 g sample) of L. monocytogenes, and were screened using the Vitek Immuno Diagnostic Assay (VIDAS) Listeria monocytogenes (VIDAS LMO)]. Positive test results were confirmed as L. monocytogenes by nonradioactive DNA probe. All samples inoculated with high levels of L. monocytogenes were detected by VIDAS and 96% were confirmed as L. monocytogenes by DNA probe. VIDAS LMO detected 89% of samples inoculated with low levels of L. monocytogenes, and 87% of these were confirmed as positive by DNA probe. In addition, 12 other samples (4 from each of mixed cut vegetable salad, smoked salmon, and sterile smoked salmon) were inoculated with high levels of L. ivanovii, L. seeligeri, L. welshimeri, L. innocua, L. grayi, and L. murrayi. Samples were assayed by the same protocol and all gave negative results. Compared with the cultural method, the VIDAS LMO nonradioactive DNA probe combination is highly specific, discriminates between L. monocytogenes and all other Listeria species, and reduces analytical time.  相似文献   

3.
In a multilaboratory study, the effectiveness of an alternative method for rapid screening of Listeria species compared to traditional reference methods was demonstrated in a variety of food products. A collaborative study was conducted to compare the VIDAS Listeria species Xpress (LSX) method and the standard cultural methods for the detection of Listeria species in foods. Six food types were tested: vanilla ice cream, cheddar cheese, raw ground beef, frozen green beans, deli turkey, and cooked shrimp. Each food, inoculated with a different Listeria strain at two levels and uninoculated test portions, was analyzed by each method. A total of 15 laboratories representing government and industry participated. In this study 1134 tests were analyzed in the statistical analysis. There were 490 positives by the VIDAS LSX method using the sample boiling step, 483 positives by the VIDAS LSX method using the Heat and Go system, and 439 positives by the standard culture methods. Overall, the Chi-square result for the VIDAS LSX method with boiling for all foods was 7.25, indicating a significant statistical difference between the VIDAS method and the standard methods at the 5% confidence. For the VIDAS LSX method with the Heat and Go system, the Chi-square result for all foods was 5.37, indicating a significant statistical difference between the VIDAS LSX assay with the Heat and Go system and the standard methods at the 5% level of significance. In both cases, the VIDAS method was more sensitive than the standard methods. The LSX method detects Listeria species in foods with negative or presumptive positive results in a minimum of 30 h compared to at least 5 days for the cultural methods. Based on the results of this collaborative study, it is recommended that the VIDAS LSX method be adopted as an AOAC Official Method for the detection of Listeria species in dairy products, vegetables, seafood, raw meats and poultry, and processed meats and poultry.  相似文献   

4.
A multilaboratory study was conducted to compare the automated BAX system and the standard cultural methods for detection of Listeria monocytogenes in foods. Six food types (frankfurters, soft cheese, smoked salmon, raw, ground beef, fresh radishes, and frozen peas) were analyzed by each method. For each food type, 3 inoculation levels were tested: high (average of 2 CFU/g), low (average of 0.2 CFU/g) and uninoculated controls. A total of 25 laboratories representing government and industry participated. Of the 2335 samples analyzed, 1109 were positive by the BAX system and 1115 were positive by the standard method. A Chi square analysis of each of the 6 food types, at the 3 inoculation levels tested, was performed. For all foods, except radishes, the BAX system performed as well as or better than the standard reference methods based on the Chi square results.  相似文献   

5.
The VIDAS LIS method and the traditional culture methods for detection of Listeria species in food were evaluated in a multilaboratory comparative study. The 6 foods tested were either naturally contaminated or inoculated with 3 different concentrations of Listeria. Results for each food and each contamination level with the VIDAS LIS method were as good as or better than those obtained with the traditional culture method. Of 1558 samples tested, 935 were positive: 839 by the VIDAS method and 809 by standard culture methods. Overall false negative rates were 10.3 and 13.5% for the VIDAS LIS and culture methods, respectively. The false positive rate for the VIDAS LIS assay was 1.4% based on 9 VIDAS LIS positive assays that did not confirm positive by isolation of Listeria. The agreement between the VIDAS LIS and culture methods for all samples tested was 86%.  相似文献   

6.
In this study to certify the BAX for Screening/Listeria monocytogenes assay (DuPont Qualicon, Wilmington, DE), an internal evaluation was conducted on 16 food types that were simultaneously analyzed with the BAX system (BAX), and the ISO method for the detection of L. monocytogenes (ISO). No statistically significant difference in performance between the BAX and ISO methods was observed. Inclusivity/exclusivity testing showed that the BAX system was able to detect 97 of 97 (100%) of L. monocytogenes strains tested. None of 56 other Listeria species or non-Listeria tested gave a reproducible positive BAX result. Ruggedness testing demonstrated that performance of the assay was not affected by reasonable variability in the operating parameters. BAX was then submitted for independent laboratory validation. In this phase, BAX was compared with standard culture methods for the detection of L. monocytogenes in chicken (USDA-FSIS), crab meat (BAM), and milk (AOAC). This study validated product claims of sensitivity and specificity >98% in accordance with AOAC Performance Tested Method requirements.  相似文献   

7.
Test portions from 3 environmental surface types, representative of typical surfaces found in a food production facility, were analyzed by the Visual Immunoprecipitate assay (VIP) and the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) culture method for Listeria monocytogenes and related Listeria species. In all cases, naturally contaminated environmental test samples were collected from an actual food production facility by sponge or swab. Test samples from concrete surfaces were collected by both swab and sponge; sponge test samples were collected from rubber surfaces, and swabs were used to sample steel surfaces. Test portions from each surface type were simultaneously analyzed by both methods. A total of 27 laboratories, representing government agencies as well as private industry in both the United States and Canada, participated in the study. During this study, a total of 615 test portions and controls was analyzed and confirmed, of which 227 were positive and 378 were negative by both methods. Nine test portions were positive by culture, but negative by the VIP. Five test portions were negative by culture, but positive by the VIP. Four test portions were negative by VIP and by culture, but confirmed positive when VIP enrichment broths were subcultured to selective agars. The data reported here indicate that the VIP method and the USDA/FSIS culture method are statistically equivalent for detection of L. monocytogenes and related Listeria species from environmental surfaces taken by sponges or swabs.  相似文献   

8.
The VIDAS Salmonella (SLM) Easy Salmonella method is a specific enzyme-linked fluorescent immunoassay performed in the automated VIDAS instrument. The VIDAS Easy Salmonella method is a simple 2-step enrichment procedure, using pre-enrichment followed by selective enrichment in a newly formulated broth, SX2 broth. This new method was compared in a multilaboratory collaborative study to the U.S. Food and Drug Administration's Bacteriological Analytical Manual, Chapter 5 method for five food matrixes (liquid egg, vanilla ice cream, spinach, raw shrimp, and peanut butter) and the U.S. Department of Agriculture's Microbiology Laboratory Guidebook 4.04 method for deli turkey. Each food type was artificially contaminated with Salmonella at three inoculation levels. A total of 15 laboratories representing government, academia, and industry, throughout the United States, participated. In this study, 1583 samples were analyzed, of which 792 were paired replicates and 791 were unpaired replicates. Of the 792 paired replicates, 285 were positive by both the VIDAS and reference methods. Of the 791 unpaired replicates, 341 were positive by the VIDAS method and 325 were positive by the cultural reference method. A Chi-square analysis of each of the six food types was performed at the three inoculation levels tested. For all foods evaluated, the VIDAS Easy SLM method demonstrated results comparable to those of the reference methods for the detection of Salmonella.  相似文献   

9.
Test portions from 3 environmental surface types, representative of typical surfaces found in a food production facility, were analyzed by the Assurance Listeria Polyclonal Enzyme Immunoassay (EIA) and the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) culture method for Listeria monocytogenes and related Listeria species. In all cases, naturally contaminated environmental test samples were collected from an actual food production facility by sponge or swab. Test samples from concrete surfaces were collected by both swab and sponge; sponge test samples were collected from rubber surfaces, and swabs were used to sample steel surfaces. Test portions from each surface type were simultaneously analyzed by both methods. A total of 23 collaborators, representing government agencies, as well as private industry in both the United States and Canada, participated in the study. During this study, a total of 550 test portions and controls was analyzed and confirmed, of which 207 were positive and 336 were negative by both methods. Six test portions were positive by culture, but negative by the EIA. Three test portions were negative by culture, but positive by the EIA. Two test portions were negative by EIA and by culture, but confirmed positive when EIA enrichment broths were subcultured to selective agars. The data reported here indicate that the Assurance Listeria EIA method and the USDA/FSIS culture method are statistically equivalent for detection of L. monocytogenes and related Listeria species from environmental surfaces taken by sponges or swabs.  相似文献   

10.
Listeria monocytogenes is an important foodborne pathogen that must be controlled to ensure food safety. For the years 2003 and 2004, L. monocytogenes caused 20 deaths per 100 listeriosis cases and was responsible for most food recalls for pathogen contamination. The objective of this work was to develop a quantitative method to assess disinfectant activity against L. monocytogenes. Standard procedures for testing disinfectants against 3 bacteria are described in the AOAC Official Methods of Analysis as use-dilution methods. No standard methods are provided for L. monocytogenes. In this study, preliminary efficacy of a quaternary ammonium compound with hydroperoxide ion was determined for 25 bacterial strains. The zones of inhibition ranged from 7.0 to 12.5 mm, and the minimum inhibitory concentration ranged from 5 to 250 ppm. For final efficacy, stainless steel carriers were contaminated with L. monocytogenes and tested separately for 5, 10, and 15 min in disinfectant or phenol. After exposure, the carriers were placed into 2 series of D/E neutralization broth. For 3 replications with duplicate samples, the phenol coefficient was 3.3. This research presents a technique-sensitive method that provides quantitative data for comparison and analysis of disinfectant activity against L. monocytogenes.  相似文献   

11.
A method was developed for the detection of Listeria monocytogenes in food. The method is based on real-time PCR using hydrolysis probes (5' Nuclease). This advanced PCR method was designed to reduce the time necessary to achieve results from PCR reactions and to enable the user to monitor the amplification of the PCR product simultaneously, in real-time. After DNA isolation using the BIOTECON foodproof ShortPrep II Kit designed for the rapid preparation of L. monocytogenes DNA for direct use in PCR, the real-time detection of L. monocytogenes DNA is carried out using the foodproof Listeria monocytogenes Detection Kit. The kit provides primers and hydrolysis probes for sequence-specific detection, convenient premixed reagents, and controls for reliable interpretation of results. For the internal comparison study, three different foods (soft cheese, coalfish, and smoked ham) were analyzed, chosen from the 15 food groups recommended by the AOAC Research Institute for detection of L. monocytogenes. From each food, 20 samples were inoculated with a low level (1-10 CFU/25 g) and 20 samples with a high level (10-50 CFU/25 g) of L. monocytogenes. Additionally, five nonspiked samples were prepared from each food. Depending on the matrix, the food samples were examined with the test kits and compared with the cultural methods according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture/Food Safety and Inspection Service Microbiology Laboratory Guidebook.  相似文献   

12.
Listeria monocytogenes continues to be a threat to food safety in the United States despite a "zero tolerance" policy. When Listeria species are identified by standard cultural methods, confirmation of L. monocytogenes takes days to complete. RAPID'L.Mono agar, developed by Bio-Rad Laboratories, is a chromogenic medium that differentiates L. monocytogenes from other species of Listeria by a simple color change reaction. Differentiation is based on the specific detection of phosphatidylinositol phospholipase C activity, resulting in a blue colony, and the inability of L. monocytogenes to metabolize xylose, resulting in the absence of a yellow halo. Detection principles of standard method agars, Oxford and PALCAM, are based on the ability of all species of Listeria to hydrolyze esculin. Thus, all species of Listeria have similar colony morphology on these agars, making differentiation of pathogenic L. monocytogenes from other nonhuman pathogens difficult. RAPID'L.Mono agar has been validated with surimi, mixed salad, brie, and processed deli turkey because of the prevalence of L. monocytogenes in these foods. Sensitivity and specificity for this medium was determined to be 99.4 and 100%, respectively. Overall method agreement of RAPID'L.Mono with standard culture methods (U.S. Department of Agriculture/Food Safety and Inspection Service; U.S. Food and Drug Administration/Bacteriological Analytical Manual; and AOAC INTERNATIONAL) was excellent, with enrichment protocols 24 h shorter than those of standard methods.  相似文献   

13.
The ability of Listeria monocytogenes to attach to various food contact surfaces, such as stainless steel, polypropylene, and rubber compounds, is well documented. The retention of these or other pathogenic bacteria on food contact surfaces increases the risk of transmission to food products. The objective of this study was to compare several methods for quantitative recovery of Listeria monocytogenes from stainless steel surfaces. A cocktail of 4 serotypes of Listeria monocytogenes mixed in equivalent concentrations was inoculated onto type 304 stainless steel coupons in a 2 x 2 cm area. After 1 h exposure, coupons were sampled by one of the following methods: (1) swabbing with a premoistened Dacron swab; (2) rinsing with phosphate-buffered saline; (3) direct contact onto tryptic soy agar containing 0.6% yeast extract (TSA + YE) plates for 10 s; (4) sonication in an ultrasonic water bath (40 kHz); (5) contact with the bristles of a sonicating brush head for 1 min; and (6) indirect contact (2-4 mm distance) with a sonicating brush head for 1 min. The 3 sonication methods yielded higher recovery than the other 3 methods (P < 0.05). Brushing the coupons with the sonicating brush head (contact or noncontact) yielded a recovery level of about 60%. The lowest cell recovery (about 20%) was observed with the swab and direct agar contact methods. After a 12 h exposure, recoveries ranged from 17.4 (brush contact method) to 2% (swab method).  相似文献   

14.
Molecular subtyping methods for Listeria monocytogenes   总被引:2,自引:0,他引:2  
Conventional, phenotypic, and DNA-based subtyping methods allow differentiation of Listeria monocytogenes beyond the species and subspecies level. Bacterial subtyping methods not only improve our ability to detect and track human listeriosis outbreaks, but also provide tools to track sources of L. monocytogenes contamination throughout the food system. The use of subtyping methods also provides an opportunity to better understand the population genetics, epidemiology, and ecology of L. monocytogenes. The last 5 years have seen tremendous advancements in the development of sensitive, rapid, automated, and increasingly easy-to-use molecular subtyping methods for L. monocytogenes. This review highlights key aspects of different L. monocytogenes subtyping methods and provides examples of their application in public health, food safety, population genetics, and epidemiology. A significant focus is on the application of subtyping methods to define L. monocytogenes subtypes and clonal groups, which may differ in phenotypic characteristics and pathogenic potential.  相似文献   

15.
A new DNA hybridization assay in microwell format for detection of Listeria spp. in foods and environmental samples was developed. This assay uses Listeria-specific oligonucleotide probes labeled with horseradish peroxidase and a photometrically determined end point. Validation studies with 15 different food commodities and a variety of environmental sample types were conducted to compare the performance of this alternative test versus reference methods. Meats, seafood, dairy products, and vegetables comprised the categories of food tested. Food samples were inoculated at 2 levels and refrigerated or frozen for at least 72 h. Uninoculated (negative) control samples were included in each trial. Samples were enriched according to the procedure recommended by either the U.S. Food and Drug Administration (FDA) or the U.S. Department of Agriculture (USDA), Food Safety and Inspection Service (FSIS). Samples enriched for 24 h were transferred to Oxford agar plates and incubated for 24 h. The surface of the plates was then swabbed and any growth present was transferred to phosphate buffer solution for the performance of the DNA assay. A standard confirmation procedure was used to compare the number of positive samples obtained with the DNA method versus reference methods. Statistical analyses of the results indicate that the proposed alternative method performs equally to cultural reference methods. The DNA assay is able to detect as low as 1 colony-forming unit of Listeria in a 25 g food sample, with results available as early as 48 h after the start of sample enrichment.  相似文献   

16.
A multilaboratory study was conducted to compare the automated BAX System to the standard cultural methods for detection of Salmonella in selected foods. Five food types--frankfurters, raw ground beef, mozzarella cheese, raw frozen tilapia fish, and orange juice--at 3 inoculation levels, were analyzed by each method. A sixth food type, raw ground chicken, was tested using 3 naturally contaminated lots. A total of 16 laboratories representing government and industry participated. In this study, 1386 samples were analyzed, of which 1188 were paired samples and 198 were unpaired samples. Of the 1188 paired samples, 461 were positive by both methods and 404 were negative by both methods. Thirty-seven samples were positive by the BAX System but negative by the standard reference method, and 11 samples were positive by standard cultural method and negative by the BAX System. Of the 198 unpaired samples, 106 were positive by the BAX System and 60 were positive by the standard cultural method. A Chi square analysis of each of the 6 food types, at the 3 inoculation levels tested, was performed. For all foods, the BAX System demonstrated results comparable to those of the standard reference methods based on the Chi square results.  相似文献   

17.
A one-step, recovery-enrichment broth, optimized Penn State University (oPSU) broth, was developed to consistently detect low levels of injured and uninjured Listeria monocytogenes cells in ready-to-eat foods. The oPSU broth contains special selective agents that inhibit growth of background flora without inhibiting recovery of injured Listeria cells. After recovery in the anaerobic section of oPSU broth, Listeria cells migrated to the surface, forming a black zone. This migration separated viable from nonviable cells and the food matrix, thereby reducing inhibitors that prevent detection by molecular methods. The high Listeria-to-background ratio in the black zone resulted in consistent detection of low levels of L. monocytogenes in pasteurized foods by both cultural and molecular methods, and greatly reduced both false-negative and false-positive results. oPSU broth does not require transfer to a secondary enrichment broth, making it less laborious and less subject to external contamination than 2-step enrichment protocols. Addition of 150mM D-serine prevented germination of Bacillus spores, but not the growth of vegetative cells. Replacement of D-serine with 12 mg/L acriflavin inhibited growth of vegetative cells of Bacillus spp. without inhibiting recovery of injured Listeria cells. oPSU broth may allow consistent detection of low levels of injured and uninjured cells of L. monocytogenes in pasteurized foods containing various background microflora.  相似文献   

18.
建立了食品中沙门菌和单增李斯特菌的多重PCR-芯片电泳快速检测方法。根据沙门菌和单增李斯特菌的特征基因合成2对特异性引物,优化聚合酶链反应(PCR)体系,采用芯片毛细管电泳快速检测食品中上述2种致病菌的多重PCR扩增产物。在优化的实验条件下,6 min内即可完成沙门菌和单增李斯特菌的同时检测;迁移时间的日内精密度为0.20%~1.7%,日间精密度3.7%~4.5%。  相似文献   

19.
A method was developed for the detection of L. monocytogenes in food based on real-time polymerase chain reaction (PCR). This advanced PCR method was designed to reduce the time needed to achieve results from PCR reactions and to enable the user to monitor the amplification of the PCR product simultaneously, in real-time. After DNA isolation using the Roche/BIOTECON Diagnostics ShortPrep foodproof II Kit (formerly called Listeria ShortPrep Kit) designed for the rapid preparation of L. monocytogenes DNA for direct use in PCR, the real-time detection of L. monocytogenes DNA is performed by using the Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes Detection Kit. This kit provides primers and hybridization probes for sequence-specific detection, convenient premixed reagents, and different controls for reliable interpretation of results. For repeatability studies, 20 different foods, covering the 15 food groups recommended from the AOAC Research Institute (AOAC RI) for L. monocytogenes detection were analyzed: raw meats, fresh produce/vegetables, processed meats, seafood, egg and egg products, dairy (cultured/noncultured), spices, dry foods, fruit/juices, uncooked pasta, nuts, confectionery, pet food, food dyes and colorings, and miscellaneous. From each food 20, samples were inoculated with a low level (1-10 colony-forming units (CFU)/25 g) and 20 samples with a high level (10-50 CFU/25 g) of L. monocytogenes. Additionally, 5 uninoculated samples were prepared from each food. The food samples were examined with the test kits and in correlation with the cultural methods according to U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) or U.S. Department of Agriculture (USDA)/Food Safety and Inspection Service (FSIS) Microbiology Laboratory Guidebook. After 48 h of incubation, the PCR method in all cases showed equal or better results than the reference cultural FDA/BAM or USDA/FSIS methods. Fifteen out of 20 tested food types gave exactly the same amount of positive samples for both methods in both inoculation levels. For 5 out of 20 foodstuffs, the PCR method resulted in more positives than the reference method after 48 h of incubation. Following AOAC RI definition, these were false positives because they were not confirmed by the reference method (false-positive rate for low inoculated foodstuffs: 5.4%; for high inoculated foodstuffs: 7.1%). Without calculating these unconfirmed positives, the PCR method showed equal sensitivity results compared to the alternative method. With the unconfirmed PCR-positives included into the calculations, the alternative PCR method showed a higher sensitivity than the microbiological methods (low inoculation level: 100 vs 98.0%; sensitivity rate: 1; high inoculation level: 99.7 vs 97.7%; sensitivity rate, 1). All in-house and independently tested uninoculated food samples were negative for L. monocytogenes. The ruggedness testing of both ShortPrep foodproof II Kit and Roche/BIOTECON LightCycler foodproof L. monocytogenes Detection Kit showed no noteworthy influences to any variation of the parameters component concentration, apparatus comparison, tester comparison, and sample volumes. In total, 102 L. monocytogenes isolates (cultures and pure DNA) were tested and detected for the inclusivity study, including all isolates claimed by the AOAC RI. The exclusivity study included 60 non-L. monocytogenes bacteria. None of the tested isolates gave a false-positive result; specificity was 100%. Three different lots were tested in the lot-to-lot study. All 3 lots gave equal results. The stability study was subdivided into 3 parts: long-term study, stress test, and freeze-defrost test. Three lots were tested in 4 time intervals within a period of 13 months. They all gave comparable results for all test intervals. For the stress test, LightCycler L. monocytogenes detection mixes were stored at different temperatures and tested at different time points during 1 month. Stable results were produced at all storage temperatures. The freeze-defrost analysis showed no noteworthy aggravation of test results. The independent validation study examined by Campden and Chorleywood Food Research Association Group (CCFRA) demonstrated again that the LightCycler L. monocytogenes detection system shows a comparable sensitivity to reference methods. With both the LightCycler PCR and BAM methods, 19 out of 20 inoculated food samples were detected. The 24 h PCR results generated by the LightCycler system corresponded directly with the FDA/BAM culture results. However, the 48 h PCR results did not relate exactly to the FDA/BAM results, as one sample found to be positive by the 48 h PCR could not be culturally confirmed and another sample which was negative by the 48 h PCR was culturally positive.  相似文献   

20.
Detection of L. monocytogenes is often limited by the performance of the enrichment media used to support bacterial growth to detectable levels. Because Listeria may exist at extremely low levels in foods, sample enrichment protocols must amplify these low initial populations to detectable limits. Listeria may also exist in an injured state in food products as a result of processing treatments such as heating, freezing, exposure to acids, or exposure to sanitizing compounds. Selective agents in enrichment media normally used for recovery of Listeria may inhibit repair and detection of sublethally injured Listeria, which may go on to repair, grow, and regain pathogenicity. Simple modifications to existing regulatory protocols, such as those that use more than one enrichment broth, raise sensitivity of detection to 90%. This review shows the efficacy of repair/enrichment strategies, which increase sensitivity of detection to 97.5-98.8% compared with 65-70% by standard regulatory protocols. Ribotype analysis of isolates obtained from meat samples reveals a complex microbial ecology, with striking differences in both number and distribution of distinct genetic types of Listeria, depending upon whether samples are enriched in selective or repair/enrichment media. In studies on enrichment of dairy environmental samples in University of Vermont medium and Listeria repair broth (UVM and LRB), combining these 2 primary enrichment media into a single tube of Fraser broth for dual secondary enrichment yielded a significantly higher percentage (p < 0.05) of Listeria-positive samples than did use of either LRB or UVM alone. Refinement of conventional Listeria recovery methods should consider the importance of the enrichment step, the nutritional needs of specific genetic types, and the physiological condition of Listeria isolates in foods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号