首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chromium(III) ion selective electrode based on glyoxal bis(2-hydroxyanil)   总被引:1,自引:0,他引:1  
Gholivand MB  Sharifpour F 《Talanta》2003,60(4):707-713
A poly(vinyl chloride) membrane based on glyoxal bis(2-hydroxyanil) as membrane carrier was prepared and investigated as a Cr(III)-selective electrode. The electrode has a linear dynamic range of 3.0×10−6-1.0×10−2 mol l−1, with a Nernstian slope of 19.8±0.5 mV per decade and a detection limit of 6.3×10−7 mol l−1. It has a fast response time of <20 s and can be used for at least 3 months without any considerable divergence in potential. The proposed electrode revealed good sensitivities for Cr(III) over a wide variety of metal ions and could be used in a pH range of 2.7-6.5. Above all, the membrane sensor has been used very successfully for the analysis of some food materials and alloys for the determination of Cr(III) ion.  相似文献   

2.
The potentiometric response characteristics of Cu2+-selective electrodes based on bis(acetylacetone)propylenediimine (I) combined with anion localizing agent (sodium tetraphenyl borate (NaTPB)) and solvent mediators (dibutyl butyl phosphonate (DBBP), tri-n-butyl phosphate (TBP) and chloronaphthalene (CN)) were investigated. The best results for Cu2+ sensing was obtained for the electrode membrane containing PVC, I, DBBP and NaTPB in composition 5:100:200:6 (I:PVC:DBBP:NaTPB) (w/w; mg), where the electrode had a Nernstian response (30.0 mV/decade) to Cu2+ within the concentration range 1.0 × 10−5 to 1.0 × 10−1 M and detection limit of 0.5 ppm. The operational pH range of the electrode was 3.3-7.0. Selectivity characteristic of the proposed electrode was also assessed by calculating using fixed interference method matched potential method. The sensor has been successfully used in the potentiometric titration of copper ions with EDTA.  相似文献   

3.
A coated-wire ion-selective electrode (CWISE), based on a Schiff base as a neutral carrier, was successfully developed for the detection of Pb(II) in aqueous solution. CWISE exhibited a linear response with a Nernstian slope of 29.4 +/- 0.5 mV/decade within the concentration range of 1.0 x 10(-5) - 1.0 x 10(-1) M lead ion. CWISE has shown detection limits of 5.0 x 10(-6) M. The electrode exhibited good selectivity over a number of alkali, alkaline earth, transition and heavy metal ions. This sensor yielded a steady potential within 10 to 20 s at a linear dynamic range. The electrode was suitable for use in aqueous solutions in a pH range of 2.0 to 5.0. Applications of this electrode for the determination of lead in real samples and as indicator electrode for potentiometric titration of Pb2+ ion using K2CrO4 are reported.  相似文献   

4.
A novel solvent polymeric membrane electrode based on bis(1,3,4-thiadiazole) complexes of Hg(II) is described which has excellent selectivity and sensitivity toward iodide ion. The electrode, containing 1,4-bis(5-methyl-1,3,4-thiadiazole-2-yl-thio)butanemercury(II) [Hg(II)BMTB(NO3)4], has a Nernstian potentiometric response from 2.0×10–8 to 2.0×10–2 mol L–1 with a detection limit of 8.0×10–9 mol L–1 and a slope of –59.0±0.5 mV/decade in 0.01 mol L–1 phosphate buffer solution (pH 3.0, 20°C). The selectivity sequence observed is iodide>bromide>thiocyanate>nitrite>nitrate>chloride>perchlorate>acetate>sulfate. The selectivity behavior is discussed in terms of the UV–Vis spectrum, and the process of transfer of iodide across the membrane interface is investigated by use of the AC impedance technique. The electrode was successfully applied to the determination of iodide in Jialing River and Spring in Jinyun Mountains, with satisfactory results.  相似文献   

5.
6.
A new PVC membrane mercury(II) ion electrode based on N,N-dimethylformamide-salicylacylhydrazone (DMFAS) as an ionophore is described, which shows excellent potentiometric response characteristics and displays a linear log[Hg(2+)] versus EMF response over a wide concentration range between 6.2 x 10(-7) and 8.0 x 10(-2) M with a Nerstian slope of 29.6 mV per decade and a detection limit of 5.0 x 10(-7) M. The response time for the electrode is less than 30 s and the electrode can be used for more than 2 months with less than a 2 mV observed divergence in a potentials. The proposed electrode exhibits very good selectivity for mercury(II) ions over many cations in a wide pH range (pH 1 - 4). The electrode was also applied to the determination of a mercury(II) ion in vegetables and in Azolla filiculoides.  相似文献   

7.
The potentiometric response properties and applications of a tetra-coordinate nickel(II) complex with relatively high selectivity toward nitrate ion are described. The nickel(II) complex of 5,7,12,14-tetramethyl-1,4,8,11-tetraazacyclotetradeca-4,6,11,13-tetraene was used as a neutral carrier into plasticized poly(vinyl chloride) (PVC) membrane. The influence of several variables was investigated in order to optimize the potentiometric response and selectivity of the electrode. The resulting membrane electrode incorporating 31.0% PVC, 61.0% dioctyl phthalate (DOP) as plasticizer, 3% methyltrioctylammonium chloride (MTOAC) as a cationic additive and 5% carrier (all w/w) demonstrates a Nernstian response slope of −59.6 mV per decade over the concentration range of 5×10−6-1×10−1 M NO3. The electrode exhibits a fast response time (≤10 s), a detection limit of 2.5×10−6 M, and can be used over a wide pH range of 4-12. The electrode shows improved selectivity in comparison to most of the previously reported nitrate-selective electrodes. It was successfully applied to the determination of nitrate ion in natural water samples.  相似文献   

8.
The construction, performance characteristics and applications of a polymeric membrance electrode for lead(II) ion are reported. The electrode was prepared by incorporating cryptand(222) as the neutral carrier into a plasticized poly(vinyl chloride) membrane. The influence of membrane composition, pH and concentration of internal reference solution were investigated. The electrode exhibits a potentiometric response for Pb2+ ion over the concentration range 10–1–10–5 M with a detection limit of 5 × 10–6 M Pb2+. It shows a relatively fast response time of about 30 s and can be used for about two months without any considerable divergence in potential. The proposed sensor revealed good selectivities for Pb2+ in the presence of several metal ions and could be used in the pH range of 2.5 to 7.5. It was used as an indicator electrode in the potentiometric titration of Pb2+ with EDTA. Received: 20 November 1998 / Revised: 26 March 1999 / Accepted: 31 March 1999  相似文献   

9.
The construction, performance characteristics and applications of a polymeric membrance electrode for lead(II) ion are reported. The electrode was prepared by incorporating cryptand(222) as the neutral carrier into a plasticized poly(vinyl chloride) membrane. The influence of membrane composition, pH and concentration of internal reference solution were investigated. The electrode exhibits a potentiometric response for Pb2+ ion over the concentration range 10–1–10–5 M with a detection limit of 5 × 10–6 M Pb2+. It shows a relatively fast response time of about 30 s and can be used for about two months without any considerable divergence in potential. The proposed sensor revealed good selectivities for Pb2+ in the presence of several metal ions and could be used in the pH range of 2.5 to 7.5. It was used as an indicator electrode in the potentiometric titration of Pb2+ with EDTA. Received: 20 November 1998 / Revised: 26 March 1999 / Accepted: 31 March 1999  相似文献   

10.
Wu HL  Yu RQ 《Talanta》1987,34(6):577-579
A pH-sensitive PVC membrane electrode based on methyldioctadecylamine as neutral carrier has been prepared. It gives linear response over the pH-range 3.0-11.0 and a slope of - 58.4 +/- 0.3 mV/pH (at 20 degrees). The electrode has fairly low resistance and good potential reproducibility. The selectivity and other characteristics of the electrode have been studied.  相似文献   

11.
A novel selective thiocyanate PVC membrane electrode based on bis-bebzoin-semitriethylenetetraamine binuclear copper(II) [Cu(II)2–BBSTA] as neutral carrier is reported, which displays an anti-Hofmeister selectivity sequence in following order: SCN > ClO4 > I >Sal >SO32− >NO3 > H2PO4 > Cl >NO2 > SO42−. The electrode exhibits Nernstian potential linear range to thiocyanate from 1.0 × 10−1 to 9.0 × 10−7 mol/l with a detection limit 7.0 × 10−7 mol/l and a slope of −57.0 mV/decade in pH 5.0 of phosphorate buffer solution at 25 °C. The response mechanism is discussed in view of the AC impedance technique and the UV spectroscopy technique. From comparison of potentiometric response characteristics between the binuclear metallic complex copper(II) [Cu(II)2–BBSTA] and mononuclear copper(II) metallic complex [Cu(II)–BBSDA], an enhanced response towards thiocyanate from the electrode based on binuclear metallic complex copper (II) [Cu(II)2–BBSTA] was observed. The electrode based on binuclear copper(II) compound was used to determine the thiocyanate content in waste water with satisfactory results.  相似文献   

12.
Scanning electron microscopy (SEM) and energy dispersive atomic X-ray spectrometry (EDAX) were used to study the response mechanism of a previously reported new Hg membrane ion-selective electrode (ISE) based on 1,3-diphenylthiourea. These techniques allowed the study of the membrane surface characteristics, such as the morphological homogeneity and chemical composition. A 'twice Nernstian' response at pH > or = 7 was explained by the detection of the Hg(OH)+ cation. A normal Nernstian response was found at acidic pH values. Using these techniques, both coordination compounds, [Ligand-Hg-OH] at pH 7 and [Ligand-Hg-Ligand] at pH 4.5, were confirmed on the electrode membrane surface activated with Hg(NO3)2 solution at both pH values. These methods provide results which are independent of the potential measurement data and in agreement with them. A successful response model has explained both independent and unbiased sets of results. These conclusions confirm the proposed response mechanisms for this new Hg membrane sensor.  相似文献   

13.
Cu2+ selective PVC membrane electrode based on new Schiff base 2, 2'-[1,9 nonanediyl bis (nitriloethylidyne)]-bis-(1-naphthol) as a selective carrier was constructed. The electrode exhibited a linear potential response within the activity range of 1.0 x 10(-6) - 5.0 x 10(-3) moll(-1) with a Nernstian slope of 29 +/- 1 mV decade(-1) of Cu2+ activity and a limit of detection 8.0 x 10(-7) mol l(-1). The response time of the electrode was fast, 10 s, and stable potentials were obtained within the pH range of 3.5- 6.5. The potentiometric selectivity coefficients were evaluated using two solution method and revealed no important interferences except for Ag+ ion. The proposed electrode was applied as an indicator electrode to potentiometric titration of Cu2+ ions and determination of Cu2+ content in real samples such as black tea leaves and multivitamin capsule.  相似文献   

14.
A novel selective thiocyanate electrode of a PVC membrane based on bis-[N-(2-hydroxyethyl)salicylaldimino]copper(II) [Cu(II)-BNSDM] as a neutral carrier is reported. The selectivity sequence of this electrode is as follows: SCN- > ClO4- > I- > Sal- > Br- > NO2- > Cl- > NO3- > H2PO4- > SO4(2-), which is an anti-Hofmeister selectivity sequence. The electrode exhibits a Nernstian potential linear range to thiocyanate from 1.0 x 10(-1) to 6.0 x 10(-6) mol/L with a detection limit of 2.0 x 10(-6) mol/L and a slope of (-59.0+/-0.2)mV/decade in pH 5.0 of a phosphate buffer solution at 25 degrees C. Electrochemical impedance spectroscopy (EIS) and UV spectroscopy techniques were performed to understand the response mechanism of the electrode. The electrode had the advantage of simplicity, high selectivity, fast response and low detection limit compared with the other electrode, which had been reported before. The electrode had been applied to wastewater analysis, and the obtained results were satisfactory.  相似文献   

15.
Gholivand MB  Nozari N 《Talanta》2001,54(4):597-602
Poly(vinyl chloride) membrane electrode, that is highly selective and sensitive to Cu(II) ions, was developed by using 2,2'-dithiodianiline and dibutyl phthalate as carrier and plasticizer, respectively. The electrode exhibits good potentiometric response for Cu(II) over a wide concentration range (5.0x10(-2)-7.0x10(-7) mol l(-1)) with Nernstian slope of 30+/-1 mV per decade. The response time of the electrode is 10 s and it has been used for a period of one month and exhibits good selectivity towards Cu(2+) in comparison to alkali, alkaline earth, transition and heavy metal ions, with no interference caused by Pb(2+), Cd(2+) and Fe(+2) which are known to interfere with many other copper electrodes.  相似文献   

16.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on butane -2,3-dione bis(salicylhydrazonato) zinc(II) [Zn (BDSH)] complex as carrier for thiocyanate-selective electrode is reported. The influence of membrane composition, pH and possible interfering anions were investigated on the response properties of the electrode. The sensor responds to thiocyanate in linear range from 1.0 × 10−6 to 1.0 × 10−1 M with a slope −56.5 ± 1.1 mV decade−1, over a wide pH range of 3.5-8.5. The limit of detection of the electrode was 7.0 × 10−7 M SCN. Selectivity coefficients determined with fixed interference method (FIM) indicate a good discriminating ability towards SCN ion in comparison to other anions. The proposed sensor has a fast response time of about 5-15 s and can be used for at least 3 months without any considerable divergence in potential. It was applied as indicator electrode in titration of thiocyanate with Ag+ and in potentiometric determination of thiocyanate in saliva and urine samples.  相似文献   

17.
A new PVC membrane electrode for Zn2+ ions based on tetra(2-aminophenyl) porphyrin (TAPP) as membrane carrier is prepared. The sensor exhibits a linear stable response over a wide concentration range (5.0×10−5 to 1.0×10−1 M) with a slope of 26.5 mV/decade and a limit of detection 3.0×10−5 M (1.96 ppm). It has a response time of about l0 s and can be used for at least 8 months without any divergence in potential. The propose membrane sensor revealed good selectivities for Zn2+ over a wide variety of other metal ions and can be used in pH range of 3.0–6.0. It was successfully applied to the direct determination of zinc in a pharmaceutical sample and also as an indicator electrode in potentiometric titration of Zn2+ ions.  相似文献   

18.
A new PVC membrane electrode based on the bis(benzoin)-semiethylenediamine (BBSEA) complex of Hg(II) is described which exhibits excellent selectivity towards iodide, related to the unique interaction between the central Hg(II) and the iodide ion. The electrode has a linear response to iodide from 5 × 10–7 to 5 × 10–4 mol/L with a slope of 58 mV/dec.(20°C). The response characteristics were investigated in detail and the mechanism of the electrode was studied with AC impedance and quartz crystal microbalance (QCM) techniques. It can be used for iodide determinations in drug preparations.  相似文献   

19.
A new PVC membrane electrode based on the bis(benzoin)-semiethylenediamine (BBSEA) complex of Hg(II) is described which exhibits excellent selectivity towards iodide, related to the unique interaction between the central Hg(II) and the iodide ion. The electrode has a linear response to iodide from 5 × 10–7 to 5 × 10–4 mol/L with a slope of 58 mV/dec.(20°C). The response characteristics were investigated in detail and the mechanism of the electrode was studied with AC impedance and quartz crystal microbalance (QCM) techniques. It can be used for iodide determinations in drug preparations. Received: 29 January 1997 / Revised: 17 April 1997 / Accepted: 20 April 1997  相似文献   

20.
Mahajan RK  Kaur I  Lobana TS 《Talanta》2003,59(1):101-105
A new ion-selective PVC membrane electrode based on salicylaldehyde thiosemicarbazone as an ionophore is developed successfully as sensor for mercury(II) ions. The electrode shows excellent potentiometric response characteristics and displays a linear log[Hg2+] versus EMF response over a wide concentration range of 1.778×10−6-1.0×10−1 M with Nernstian slope of 29 mV per decade with the detection limit of 1.0×10−6 M. The response time of the electrode is less than 30 s and the membrane electrode operates well in the pH range of 1.0-3.0. The lifetime of the sensor is about 2 months. The electrode shows better selectivity towards Hg2+ ions in comparison with the alkali, alkaline and some heavy metal ions; most of these metal ions do not show significant interference (KPotHg,M values of the order of 10−3-10−4). The present sensor showed comparable or even better performance vis-à-vis similar PVC based ion-selective electrodes reported in literature. The sensor was also applied as an indicator electrode for potentiometric titration of Hg2+ions with I and Cr2O72−.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号