首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A Chromolith Performance octadecylsilyl (ODS) monolithic silica column (Merck) was compared with a conventional microparticulate ODS-bonded silica column in the high-performance liquid chromatography separation of natural polyprenols. A system comprising two connected monolithic columns afforded an equivalent separation at half the analysis time of the conventional method. Furthermore, ten connected columns achieved a tremendously high-resolution separation, in which the complicated series of homologous polyprenols with geometric isomerism were fully separated.  相似文献   

3.
Summary The complete separation of the major cinchona alkaloids and their dihydro derivatives is achieved in less than 30 minutes, using a Hypersil 5m octadecylsilyl column in the reversed-phase mode. Excellent peak symmetry is obtained by incorporation of a long chain amine additive in the acidic mobile phase.  相似文献   

4.
Multimodal copolymer-encapsulated particles for liquid chromatography were prepared by bonding 1-octadecene and unsaturated carboxylic acids on silica particles (5 microm diameter, 300 A pores) for liquid chromatography of proteins. These multimodal copolymer-encapsulated particles can provide both hydrophobic and hydrogen bonding interactions with polar compounds. The chromatographic performance of these multimodal copolymer-encapsulated particles for peptide and protein separations was evaluated under reversed-phase conditions. Compared with typical C8-bonded silica, polymer-encapsulated particles were more stable in acidic mobile phases and provided better recoveries, especially for large proteins (Mr>0.5 x 10(6)). Totally hydrophobic polymer-encapsulated particles were found to produce broad peaks for proteins, and significant improvements were observed by introducing hydrophilic groups (-COOH) onto the polymer-encapsulated surface to form a multimodal phase. For the reversed-phase liquid chromatography of peptides and proteins, improved selectivity and increased solute retention were found using the multimodal polymer-encapsulated particles. More peaks were resolved for the separation of complex peptide mixtures such as protein digests using the multimodal polymer-encapsulated particles as compared to totally hydrophobic polymer-encapsulated particles.  相似文献   

5.
In micro total analysis systems, liquid chromatography (LC) works under pressure-driven flow is the essential analysis component. There were not, however, much works on microchip LC. Here we developed a microchip for reversed-phase LC using porous monolithic silica. The chip consisted of a double T-shaped injector and a approximately 40-cm serpentine separation channel. The octadecyl-modified monolithic silica was prepared in the specified part of the channel on the microchip using sol-gel process. Furthermore, the effect of geometry of turn sections on band dispersion at turns was examined under pressure-driven flow. High separation efficiencies of 15,000-18,000 plates/m for catechins were obtained using the LC chip.  相似文献   

6.
Bhosale SN  Khopkar SM 《Talanta》1985,32(2):155-157
Germanium(IV) can be separated by reversed-phase extraction chromatography with TBP as stationary phase on a column of silica gel, with 6M hydrochloric acid as the mobile phase, and stripped with various eluents. Germanium can thus be separated (by selective extraction) from those elements which are not extractable with TBP, and (by selective stripping) from elements that are extractable.  相似文献   

7.
Bhosale SN  Khopkar SM 《Talanta》1979,26(9):889-891
Iron(III) is separated by reversed-phase extraction chromatography with TBP as the stationary phase on a column of silica gel, with 2-6M hydrochloric acid as the mobile phase. From knowledge of the distribution coefficients, several separations have been devised, such as separation of Fe(III) from alkali and alkaline earth metals, chromium, manganese, cobalt, nickel, copper, vanadium zirconium, thorium, uranium, yttrium and titanium.  相似文献   

8.
建立了超高效反相液相色谱-高分辨质谱方法以实现米格列奈及其3种异构体杂质的分离,以ACQUITY UPLC HSS T3(100 mm×2.1 mm,1.8 μ m)为色谱柱,以水-乙腈-正戊醇(75:25:1)(用甲酸调节pH至1.8)为流动相,流速为0.4 mL/min。根据Q Exactive四极杆/静电场轨道阱高分辨质谱的精确质量数及碎裂情况,发现了米格列奈及3种异构体存在碎片离子丰度的明显差异,确认其中两种为本次新发现的异构体杂质,并推断了米格列奈及3种异构体杂质可能的质谱裂解机理。经验证,该方法的灵敏度、重复性及线性均满足分析要求。在此基础上,对米格列奈异构体杂质的来源进行了探讨,发现异构体杂质1可在高温下降解产生,并对各企业的米格列奈钙原料样品进行了测定。  相似文献   

9.
Preparation methods of monolithic silica columns for HPLC including the surface modification were reviewed. Chemical modification methods recently reported to obtain stationary phases for reversed-phase (RP), chiral, ion-exchange, and hydrophilic interaction chromatography (HILIC) separations were discussed. Recent results related to preparation methods of monolithic silica were also covered. The characteristics and properties of silica monoliths and some applications of monolithic silica columns for different analytical and bioanalytical fields will be commented.  相似文献   

10.
Chromatographic properties of a new type of monolithic silica rod columns were examined. Silica rod columns employed for the study were prepared from tetramethoxysilane, modified with octadecylsilyl moieties, and encased in a stainless-steel protective column with two polymer layers between the silica and the stainless-steel tubing. A 25 cm column provided up to 45,000 theoretical plates for aromatic hydrocarbons, or a minimum plate height of about 5.5 μm, at optimum linear velocity of ca. 2.3 mm/s and back pressure of 7.5 MPa in an acetonitrile-water (80/20, v/v) mobile phase at 40°C. The permeability of the column was similar to that of a column packed with 5 μm particles, with K(F) about 2.4×10(-14) m(2) (based on the superficial linear velocity of the mobile phase), while the plate height value equivalent to that of a column packed with 2.5 μm particles. Generation of 80,000-120,000 theoretical plates was feasible with back pressure below 30 MPa by employing two or three 25 cm columns connected in series. The use of the long columns enabled facile generation of large numbers of theoretical plates in comparison with conventional monolithic silica columns or particulate columns. Kinetic plot analysis indicates that the monolithic columns operated at 30 MPa can provide faster separations than a column packed with totally porous 3-μm particles operated at 40 MPa in a range where the number of theoretical plates (N) is greater than 50,000.  相似文献   

11.
Silica gel was used as a support for the covalent coupling of liposomes, which could overcome drawbacks of soft gel beads in column efficiency and separation speed. The influences of the concentration of added dimethylaminopyridine and reaction time on the chloroformate activation reaction of silica gel were investigated. Temperature and pH for covalent coupling of liposomes on the activated silica gel were also optimized. Experimental results indicated that the stability of the covalently coupled liposome columns was obviously superior to that of the noncovalently coated liposome columns but the selectivity of both columns was basically identical. Separation and analysis of a crude extract of a traditional Chinese medicine Ligusticum Wallichii and a mixture of small peptides on both columns further support this conclusion.  相似文献   

12.
The separation and characterization of octylphenol ethoxylate surfactants were carried out by reversed-phase high-performance liquid chromatography on branched fluorinated silica gel columns. For Triton X-100, simultaneous separation of octylphenol ethoxylate oligomers, positional isomers of octylphenyl group and butylphenol ethoxylate oligomers was achieved. These oligomers were completely separated and identified by means of MS spectra. Ethoxylated oligomers are eluted in the sequence from small to large oligomers. Fifty-five oligomers of Triton X-405 could be separated by using gradient elution. To separate octylphenol ethoxylate surfactant, non-end-capped branched fluorinated silica gel columns were superior to end-capped columns. The relationship between ln k' and methanol concentration was linear, indicating that branched fluorinated silica gel columns were operating in the reversed-phase mode. As Van 't Hoff plots of capacity factor for all oligomers gave straight lines, the equilibrium of conformation for the ethylene oxide chain might lay to one side of either zigzag or meander conformers.  相似文献   

13.
An investigation of the liquid chromatography of the minor capsaicinoids in a commercial capsaicinoid mixture is reported. Twelve stationary phases including C8, C18, C30, phenyl, and cation-exchange chemistries were examined in combination with isocratic aqueous methanol and aqueous acetonitrile mobile phases. A phenyl stationary phase and aqueous acetonitrile mobile phase baseline-resolved 7 of 11 capsaicinoids, and selected ion chromatograms (LC–ESI-MS) demonstrated this was the most effective reversed-phase separation. Argentation chromatography with an alkyl or phenyl column and aqueous silver nitrate–methanol mobile phase revealed the presence of the 6-ene-8-methyl and 6-ene-9-methyl homocapsaicin isomers and the absence of 7-ene-9-methyl homocapsaicin. A mixed phenyl–cation-exchange stationary phase (charged with silver ion) enabled unique and useful separations of the capsaicinoids.  相似文献   

14.
The isocratic reversed-phase liquid chromatography of the angiotensins and a number of their synthetic analogues is described. Complete separation of 10 out of 12 peptides was achieved through a solvent optimization strategy with a total analysis time of about 20 min. The retention behavior of the angiotensins studied was described in terms of the hydrophobic contribution of their amino acid residues; there was good correlation between predicted and experimental retention for those peptides that were retained by a common mechanism. However, because ion-pair chromatography was required for good peak symmetry, retention was substantially modulated by the presence of acidic and basic residues. The limit of detection of these peptides was 3-5 pmol by UV absorbance at 214 nm. For those peptides containing a primary amino group the detection limit was improved by two orders of magnitude by fluorogenic derivatization with naphthalene-2,3-dicarboxaldehyde/cyanide to the corresponding N-substituted 1-cyanobenz[f]isoindole (CBI) derivatives. The contribution of the CBI ring system to retention was also investigated.  相似文献   

15.
The nucleic acid analogues poly(9-vinyladenine) (PVAd), poly(9-adenylethyl methacrylate) and poly(thymylethyl methacrylate) (PTM) were chemically bonded to porous silica gel, which had been pretreated with 3-trimethoxysilylpropyl methacrylate, by free radical copolymerization to produce novel packing materials for affinity chromatographic columns. The columns separated nucleosides and nucleotide dimers on the basis of hydrophobic interaction using an aqueous buffer and complementary hydrogen bonding interaction in methanol as an eluent. The PVAd- and PTM-silica gel columns gave a nucleobase-selective separation of oligonucleotides differing in length from mixtures of oligoadenylic and oligouridylic acids. On the PVAd-silica gel column terminal phosphate isomers of oligouridylic acid up to seven mer were resolved and the elution order of the isomers was different from that on an ODS column.  相似文献   

16.
Soluble fragments of elastin are frequently present in biological tissue in small amounts. Because of their hydrophobic character, these peptides are not well resolved by a number of conventional techniques. However, their separation should be possible by reversed-phase chromatography. A wide range of columns, gradients and solvents were evaluated. Two systems are described. One was a C18 liganded silica column eluted isocratically by gravity flow. Some degree of size fractionation was achieved with larger peptides being eluted with methanol and smaller ones with isopropanol. The second system uses a pressurized elution from another C18 ligand column. A concave gradient of trifluoroacetic acid-acetonitrile with a decreasing acetonitrile concentration was optimal. Similar resolution of peptides produced by a variety of digestion methods was obtained with the lower-molecular-mass peptides eluting in the middle of the gradient.  相似文献   

17.
Summary After summarizing published results on silica gel and alkyl-bonded silica gel solubilities, the experimental solubility of unmodified silica and copper silicate gel (used in ligand exchange chromatography) in watermethanol-ammonia and water-acetonitrile-ammonia mixtures are given. These results demonstrate that silica gel solubility, measured by a static method, varies greatly with the water volume fraction of a ternary mixture. Curiously, no influence from the organic nature of the solvent was demonstrated. This observation is inconsistent with the fact that the copper silicate gel used in ligand-exchange chromatography with water-methanol-ammonia as mobile phase is attacked more rapidly than with water-acetonitrile-ammonia.An explanation based upon the variations of acid-base properties of silicic acid versus mobile phase dielectric constant values in conjunction with the methanol protophilic properties is proposed. Finally, it is shown that chromatographic columns filled with copper silicate gel have lifetimes of several months, if they are used with a procolumn (of copper silicate gel) and with acetonitrile as organic solvent with a volume fraction greater than 0.5 in the mobile phase.  相似文献   

18.
19.
20.
The efficiency and dynamic characteristics of seven silica-gel-based monolithic capillary columns were analyzed by separating on them a mixture of five light hydrocarbons. For helium carrier gas flowing at an optimum velocity, the height equivalent to a theoretical plate was found to be 0.15–0.20 mm, values comparable to those typical of packed capillary columns. An analysis of the Van Deemter curves for the columns under study demonstrated that the main contribution to the smearing of the chromatographic zone comes from the diffusional processes in the mobile phase while the mass transfer between the mobile and stationary phases plays only a minor role. At the same time, the parameter A in the Van Deemter equation, which characterizes the degree of column packing uniformity, was found to be negative. This result contradicts the classical theory of chromatography and calls for further studies of monolithic capillary columns.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号