首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Controlled adsorptive accumulation of testosterone, methyltestosterone and progesterone on the static mercury drop electrode provides the basis for direct stripping measurement of these compounds ar nanomolar concentrations. The adsorptive stripping behavior is evaluated with respect to preconcentration time and potential, stripping mode, concentration dependence, drop size and other variables. With 5-min accumulation, peak current enhancements of 45, 18 anal 12 are observed for 5 × 10?8 M testosterone, progesterone and methyltestosterone, respectively, relative to direct pulse voltammetry. Detection limits are 1.6 × 10?10 M for testosterone, 2 × 10?10 M for progesterone and 3.3 × 10?10 M for methyltestosterone with 15-min preconcentration. The relative standard deviation for 8 × 10?8 M progesterone is 3.4% (n=8). Applicability to direct measurements of methyltestosterone in pharmaceutical formulations is assessed.  相似文献   

2.
Controlled adsorptive accumulation at the hanging mercury drop electrode enables 0.8–11 × 10?5 M chlordiazepoxide to be quantified by differential-pulse stripping voltammetry with accumulation times of 1–3 min. With 3-min accumulation, the peak current is enhanced 12-fold for 1.0 × 10?7 M chlordiazepoxide compared to the current from differential pulse polarography. The detection limit is 0.9 × 10?9 M for 4-min accumulation. The procedure is applied to spiked human serum after preseparation of the drug on a Sep-Pak C18 cartridge.  相似文献   

3.
Arsenic (III), respectively arsenic(V) after the reduction were determined in model solutions and some inorganic and organic materials by fast scan differential pulse cathodic stripping voltammetry and by direct current cathodic stripping voltammetry with a rapid increase of potential. The accumulation on a hanging mercury drop electrode followed by cathodic stripping was carried out in 0.7–0.8M HCl or 1–2M H2SO4 solutions containing Cu(II)-ions. Detection limits calculated from regression parameters was determined to be under 1 ng/ml for the samples containing very low arsenic concentrations. The relative standard deviation did not reach 8% for arsenic contents about of 5 ng/ml.  相似文献   

4.
Dimenhydrinate exhibits a single adsorptive stripping peak at a hanging mercury drop electrode after accumulation at 0.0V vs Ag/AgCl electrode at pH 3.8 (acetate buffer). The addition of trace amounts of copper ions enhanced the dimenhydrinate peak and its height depends on the concentration of each dimenhydrinate and Cu2+. The adsorptive stripping response was evaluated with respect to accumulation time and potential, concentration dependence, electrolyte, the presence of other purines, surfactants and other metal ions, and some variables. The calibration graph for dimenhydrinate determination is linear over the range 2.0×10–8–2.0×10–7 M (pre-concentration for 60s). The correlation factor is found to be 0.985 and RSD is 3.2% at 1.0×10–7 M. Detection limit is 1.0×10–8 M after 5 min accumulation. The determination of dimenhydrinate in pharmaceutical formulations by the proposed method is also reported.  相似文献   

5.
The behaviour of selenium(IV) in cathodic stripping voltammetry is evaluated systematically. The effects of copper concentration, pH, deposition potential and complexing agents on the stripping peak are examined and criteria are given for the choice of suitable quantitative parameters. The detection limit was found to be 20 ng l?1 and the background contamination level was 35 ng l?1. Zinc and lead do not affect the determination of selenium if EDTA is added to the solution whereas cadmium interferes badly; the corresponding mechanisms are discussed.  相似文献   

6.
Adsorptive stripping voltammetry was used for the determination of trace amounts of the dye Tartrazine (E-102) by square-wave (SWS) and differential pulse techniques (DPS). Its adsorptive voltammetric behaviour was investigated at different pH media. NH4Cl/NH3 buffer solution was chosen as the most suitable, taking into account the sensitivity and definition of the reduction peaks obtained. The effects of the experimental parameters on the determination are discussed. Standard deviations of 3.3% and 2.6% were obtained by SWS and DPS for 100 and 50 μg/L Tartrazine solutions, respectively (n = 10). Both methods were applied to determine the dye in several commercial soft drinks, containing very small amounts of it. Measurements were made directly in the commercial samples. A comparison of the results obtained by the proposed voltammetric methods with those of an HPLC method was also made. Good correlations between the voltammetric results and the values supplied by the manufacturer were found, whereas recoveries of the same order of magnitude were obtained by the HPLC method. Received: 23 May 1996 / Revised: 5 July 1996 / Accepted: 10 July 1996  相似文献   

7.
Hu N  Guo H  Lin S 《Talanta》1994,41(8):1269-1274
In a supporting electrolyte of NaOH, a pair of cathodic and anodic peaks of N,N'-diphenyl-N,N'-bis(1-phenylmethyl-4-piperidinyl)-ethanediamide (DBPPE) is found by cyclic voltammetry at a Hg electrode. The cathodic and anodic peak potentials are -1.53 and -1.46 V (vs. Ag/AgCl), respectively. The cathodic peak shows adsorptive characteristics when the concentration of DBPPE is low and the preconcentration time is long. The adsorbed species is most probably the DBPPE neutral molecule. The method for measuring trace amount of DBPPE by adsorptive stripping voltammetry is established and the detection limit can reach 5 x 10(-9)M with a 6-min preconcentration.  相似文献   

8.
Folic acid can be determined at nanomolar concentrations by controlled adsorptive accumulation of folic acid on a static mercury drop electrode held at ?0.3 V vs. Ag/AgCl followed by reduction of the surface species. In 0.1 M sulfuric acid, a cathodic scan gives peaks at ?0.47 v and ?0.75 V vs. Ag/Agcl; the latter peak provides greater sensitivity. Differential-pulse stripping is shown to be superior to normal-pulse and d.c. stripping. After a 5-min preconcentration, the detection limit is about 1 × 10?10 M folic acid. The adsorptive stripping response is evaluated with respect to concentration dependence, preconcentration time and potential, solution acidity and the presence of gelatin and bromide. The relative standard deviation at the 5 × 10?8 M level is 1.2%. This method is applied to the determination of folic acid in pharmaceutical tablets.  相似文献   

9.
Ertas FN  Fogg AG  Moreira JC  Barek J 《Talanta》1993,40(10):1481-1488
The behaviour of the copper complexes of glycyl-L-histidyl-glycine (GHG) was investigated using cyclic voltammetry and differential pulse voltammetry after their adsorptive accumulation on the surface of a hanging mercury drop electrode (HMDE). The nature of the observed cathodic and anodic peaks was established and optimum conditions were found for the differential pulse cathodic stripping voltammetric detemination of GHG at the 1 x 10(-8)M concentration level using adsorptive accumulation at -0.20 V vs. Ag/AgCl reference electrode and the cathodic stripping peak around -0.4 V (pH 8.3). This peak corresponds to the reduction of the Cu(I)-GHG complex formed at the HMDE surface as an intermediate in the reduction of Cu(II)-GHG to Cu(O)amalgam.  相似文献   

10.
Farias PA  Ohara AK  Takase I  Ferreira SL  Gold JS 《Talanta》1993,40(8):1167-1171
A new method is described for the determination of Ni based on the cathodic adsorptive stripping of Ni(II) complexed with hydroxynaphthol blue (HNB) at a static mercury drop electrode. Optimal conditions were found to be: accumulation potential -0.50 V (vs. Ag/AgCl); final potential -1.10 V; accumulation time 50 sec; scan rate 200 mV/sec; linear scan mode; filter 0.1 sec; supporting electrolyte acetic acid/acetate (0.25M, pH = 6.0) and concentration of HNB 3.3 x 10(-5)M. The response of the system was found to be linear in a range of Ni concentrations from 25 ppb to the detection limit. The detection limit was found to be 1.7 nM (0.10 ppb) with 2 mins of accumulation time. The effect of various potential interferences (including a variety of cations, anions and organic surfactants) were also studied. With the exception of Co, at less than equimolar concentrations no significant interferences were observed. Al was found to interfere at high concentrations with respect to Ni, but Al concentrations up to 1000 ppb may be masked by sodium citrate or sodium fluoride. The utility of the method is demonstrated by the recovery of Ni in a doped sample of commercial mineral water.  相似文献   

11.
Pseudouridine (5-ribosyluracil), uridine (N,1-ribosyluracil), deoxyuridine (N,1-deoxyribosyluracil) and uracil are investigated by means of d.c. polarography and by differential and normal pulse polarography. Pseudouridine, which is known to be a cancer marker, yields anodic polarographic currents in the pH range 7–11, whereas uridine and deoxyuridine are inactive under the same conditions. The polarographic response of pseudouridine obtained is due to the formation of a sparingly soluble mercury compound. Pseudouridine can be determined by differential pulse polarography in the concentration range 2–6 × 10?6 M and by differential-pulse cathodic stripping voltammetry at concentrations two orders of magnitude lower. Small excesses of uridine, deoxyuridine or proteins do not interfere with the determination.  相似文献   

12.
13.
The Ge(IV)—Ge(0) system was investigated by cyclic and stripping voltammetry at HMDE in acidic pyrogallol medium and in phosphate, borate and carbonate buffers. It was found that germanium electrodeposited from dilute Ge(IV) solutions dissolved anodically forming two peaks corresponding to the oxidation of the unstable homogeneous and stable heterogeneous amalgams. Both peaks can be exploited analytically for the determination of traces of germanium but due to the complex nature of the germanium amalgam the sensitivity and reproducibility of the determinations are lower compared to the results obtained for metals well-soluble in mercury.  相似文献   

14.
Lutetium has been determined by differential pulse anodic stripping voltammetry in an acidic solution containing Zn-EDTA. Lutetium (III) ions liberated zinc (II), which was preconcentrated on a hanging mercury drop electrode and stripped anodically, resulting in peak current linearly dependent on lutetium (III) concentration. Less than 0.4 ng mL−1 lutetium could be detected after a 2 min deposition.   相似文献   

15.
Banica FG  Fogg AG  Moreira JC 《Talanta》1995,42(2):227-234
Oxidized glutathione (GSSG) can be determined after previous accumulation on the HMDE at E > -0.2 V (vs. the Ag AgCl reference electrode). GSH is formed during the accumulation, possibly by a mercury-ion-assisted hydrolytic disproportionation of GSSG. In the subsequent cathodic scan GSH is released and catalyses the reduction of nickel ion, giving a peak located at -0.6 V. This enables the determination of GSSG by differential-pulse cathodic stripping voltammetry at pH 7.0 in the phosphate acetate or MOPS buffer containing 0.5-1.0 mM Ni(II). The detection limit is 10 nM. The calibration graph is linear even in the presence of small amounts of human serum albumin, HSA. However, HSA increases the detection limit (20 nM for 3 x 10(-4)% HSA). Acetyl-cysteine in small excess or Cu(II) present as reagent impurity do not interfere. Glutathione, cysteine and similar compounds, which accumulate as mercury salts and form stable nickel complexes, will interfere. The method is put forward as a novel alternative stripping voltammetric method to those involving accumulation and determination as mercury or copper salts and complexes, in the knowledge that it may have advantages in particular analytical situations. In particular the method discriminates against compounds which accumulate as mercury salts but which do not form stable nickel complexes.  相似文献   

16.
The utility of a copper-based mercury film electrode (MFE) in cathodic stripping voltammetry (c.s.v.) is tested by comparing the cyclic and stripping voltammograms obtained with this electrode for thiocyanate, tryptophane, cysteine and benzotriazole against those obtained with the hanging copper-amalgam drop electrode (HCADE) and the HMDE. The cathodic stripping peaks obtained at the copper-based MFE and the HCADE are usually narrower and higher and are located at more negative potentials than the peaks obtained at the HMDE. Lower detection limits and better separations of adjacent peaks are thus achieved, and useful peaks can be separated from the mercury waves obtained with the conventional HMDE. The advantage of the copper-based MFE over the HCADE is its simplicity of preparation and maintenance. Thiocyanate, tryptophane, cysteine and benzotriazole can be determined at the copper-based MFE by c.s.v. with detection limits of 1 × 10?8, 1 × 10?8, 5 × 10?8 mol dm?3, respectively.  相似文献   

17.
Indomethacin is a non-steroidal anti-inflammatory drug possessing anti-pyretic and analgesic properties. A fully validated square-wave adsorptive cathodic stripping voltammetric procedure is described for determination of indomethacin. The procedure was based on the reduction of the C=O double bond of the drug molecule in Britton-Robinson buffer (pH 4) after its preconcentration onto the mercury electrode surface. The optimized conditions of the procedure were: frequency 120 Hz, scan increment 10 mV, pulse amplitude 50 mV, preconcentration potential -0.9 V (vs. Ag/AgCl/KCl(s)) and preconcentration time 90 s. The proposed procedure was successfully applied for determination of the drug in tablets and human serum with good recoveries. The limits of detection in bulk form and human serum were 6.7 x 10(-10) mol L(-1) and 8.1 x 10(-10) mol L(-1), respectively.  相似文献   

18.
19.
Conditions convenient for the determination of traces of seIenium(IV) by cathodic stripping technique are described. Several electrolytes were tested. Three procedures are given in which the troublesome splitting of the stripping peak is eliminated. Suitable conditions include perchloric acid solution at elevated temperature, hydrochloric acid solution after preconcentration at zero current, and perchloric acid solution containing a small amount of iodide. The detection limits are 5 × 10-9, 2 × 10-9 and 5 × 10-10 mol dm-3, respectively. The time required for the entire procedure is about 30 min starting with a soluble seIenium(IV) sample.  相似文献   

20.
A highly sensitive cathodic stripping voltammetric method for the determination of naringin is presented. It is based on the formation and accumulation of two naringin–mercury complexes at the electrode surface, followed by reduction of the surface species during a differential pulse voltammetric scan. The cathodic stripping responses at −0.25 V and −0.42 V, are evaluated with respect to various experimental conditions, such as composition and pH of the supporting electrolyte, naringin concentration, accumulation potential and preconcentration time. The new method is suitable for the determination of naringin concentrations between 0.1 mg l−1 (1.72×10−7 mol l−1) and 40 mg l−1 (6.88×10−5 mol l−1). A 3σ limit of detection of 32 μg l−1 (55 nmol l−1) can be reached. The relative standard deviation (r.s.d.) is <1.5%. Recovery experiments yielded a mean recovery of 97% (r.s.d.=4.1%). The application of the procedure to the selective determination of naringin in grapefruit juice is demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号