共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
5.
6.
Modelling and prediction of retention in high-performance liquid chromatography by using neural networks 总被引:1,自引:0,他引:1
Y. L. Xie J. J. Baeza-Baeza J. R. Torres-Lapasió M. C. García-Alvarez-Coque G. Ramis-Ramos 《Chromatographia》1995,41(5-6):435-444
Summary Multi-layer feed-forward neural networks trained with an error back-propagation algorithm have been used to model retention
behaviour of liquid chromatography as a function of the composition of the mobile phases. Conventional hydro-organic and micellar
mobile phases were considered. Accurate retention modelling and prediction have been achieved using mobile phases defined
by two, three and four parameters. With micellar mobile phases, the parameters involved included the concentrations of surfactant
and organic modifier, pH and temperature. It is shown that neural networks provide a competitive tool to model varied inherent
nonlinear relationships of retention behaviour with respect to the mobile phase parameters. The soft models defined by the
weights of the networks are capable of accommodating all types of linear and nonlinear relationships, neural networks being
specially useful when the relationships between retention behaviour and the mobile phase parameters are unknown. However,
to train neural networks more experimental points than with hard-modelling methods are required, hence the use of the networks
is recommended only for those cases where adequate theoretical or empirical models do not exist. 相似文献
7.
Y. L. Xie J. J. Baeza-Baeza J. R. Torres-Lapsió M. C. García-Alvarez-Coque G. Ramis-Ramos 《Chromatographia》1995,40(7-8):435-444
Summary Two analytical methods have been developed for the determination in water of 18 priority phenolics listed in US EPA method 604 and on EEC list 76/464. A solidphase extraction system using eight different sorbents packed in a precolumn was coupled on-line with a liquid chromatograph with UV detection. The ensuing method uses 50–100 mL of ground water; its performance was compared with that of an off-line method using Empore extraction disks and 1 L water samples. Phenol recoveries varied from <20 to 100% for concentrations in the range 0.1–10 g/L at an acid pH. The presence of the phenols in water was confirmed by using thermospray LC-mass spectrometry in the negative ion mode. The stability of the phenols in water was studied at a 10 g/l level in ground and estuarine water at acid pH (2.5–3) and at 4°C for 1 month. The system was validated by various interlaboratory exercises with samples containing 2,4,6-trichlorophenol and pentachlorophenol at concentrations from 0.1 to 0.5 g/L. 相似文献
8.
9.
10.
11.
Methods have been developed for the quantitative determination of celanide [lanatoside C] in substances, in solutions for injection, and in tablets by high-performance liquid chromatography, with the aid of which it is possible to determine small amounts of celanide (0.025 mg/ml) with adequate accuracy. The relative error of the determination does not exceed ±4.0%.All-Union Scientific-Research Institute of Physical Culture, Moscow. Translated from Khimiya Prirodnykh Soedinenii, No. 4, pp. 476–479, July–August, 1983. 相似文献
12.
13.
14.
A procedure was proposed for quantitative analysis of Pentamax tablets, a new multicomponent drug, by high-performance liquid chromatography. Model mixtures containing all active and auxiliary components of the tablets were analyzed by the introduced/found method; the absence of a systematic determination error was verified. Preproduction tablet samples were analyzed. The results of the analysis match the requirements of normative technical documentation and technologic loads. 相似文献
15.
Due to degeneracy of the observed binding sites, the in silico prediction of bacterial sigma(70)-like promoters remains a challenging problem. A large number of sigma(70)-like promoters has been biologically identified in only two species, Escherichia coli and Bacillus subtilis. In this paper we investigate the issues that arise when searching for promoters in other species using an ensemble of SVM classifiers trained on E. coli promoters. DNA sequences are represented using a tagged mismatch string kernel. The major benefit of our approach is that it does not require a prior definition of the typical -35 and -10 hexamers. This gives the SVM classifiers the freedom to discover other features relevant to the prediction of promoters. We use our approach to predict sigma(A) promoters in B. subtilis and sigma(66) promoters in Chlamydia trachomatis. We extended the analysis to identify specific regulatory features of gene sets in C. trachomatis having different expression profiles. We found a strong -35 hexamer and TGN/-10 associated with a set of early expressed genes. Our analysis highlights the advantage of using TSS-PREDICT as a starting point for predicting promoters in species where few are known. 相似文献
16.
17.
18.
E. P. Kondratovich N. I. Zhokhova I. I. Baskin V. A. Palyulin N. S. Zefirov 《Russian Chemical Bulletin》2009,58(4):657-662
The structure—activity classification models for prediction of the assignment of organic compounds to 40 pharmacological groups
were constructed in the framework of the fragmental approach using the support vector machine technique, the Platt—Wu probabilistic
model, and resampling procedure. The models constructed allow one to predict possible types of the side pharmacological effects
of drugs. 相似文献
19.