 共查询到20条相似文献,搜索用时 46 毫秒
1.
An automatic coarse-alignment method for a tilt series of rod-shaped specimen collected with a full angular range (from α = ?90° to +90°, α is the tilt angle of the specimen) is presented; this method is based on a cross-correlation method and uses the outline of the specimen shape. Both the rotational angle of the tilt axis and translational value of each image can be detected in the images without the use of markers. This method is performed on the basis of the assumption that the images taken at α = ?90° and α =  + 90° are symmetric about the tilt axis. In this study, a carbon rod on which gold particles have been deposited is used as a test specimen for the demonstration. This method can be used as an automatic coarse-alignment method prior to the application of a highly accurate alignment method because the alignment procedure can be performed automatically except for the initial setup of some parameters.  相似文献   

2.
3.
Image quality of MeV transmission electrons is an important factor for both observation and electron tomography of microns-thick specimens with the high voltage electron microscope (HVEM) and the ultra-HVEM. In this work, we have investigated image quality of a tilted thick specimen by experiment and analysis. In a 3 MV ultra-HVEM, we obtained transmission electron images in amplitude contrast of 100 nm gold particles on the top surface of a tilted 5 μm thick amorphous epoxy-resin film. From line profiles of the images, we then measured and evaluated image blurring, contrast, and the signal-to-noise ratio (SNR) under different effective thicknesses of the tilted specimen and accelerating voltages of electrons. The variation of imaging blurring was consistent with the analysis based on multiple elastic scattering. When the effective thickness almost tripled, image blurring increased from ~3 to ~20 nm at the accelerating voltage of 3 MV. For the increase of accelerating voltage from 1 to 3 MV in the condition of the 14.6 μm effective thickness, due to the reduction of multiple scattering effects, image blurring decreased from ~54 to ~20 nm, and image contrast and SNR were both obviously enhanced by a factor of ~3 to preferable values. The specimen thickness was shown to influence image quality more than the accelerating voltage. Moreover, improvement on image quality of thick specimens due to increasing the accelerating voltage would become less when it was further increased from 2 to 3 MV in this work.  相似文献   

4.
Statistically Optimal Nearfield Acoustical Holography (SONAH) can be used to reconstruct three-dimensional sound fields by projecting two-dimensional data measured on a “small” aperture that partially covers a composite sound source in a “static” fluid medium. Here, an improved SONAH procedure is proposed that includes the mean flow effects of a moving fluid medium while the sound source and receivers are stationary. The backward projection performance of the proposed procedure is further improved by using a wavenumber filter to suppress subsonic noise components. Through numerical simulations at Mach 0.6, it is shown that the improved procedure can accurately reconstruct sound source locations and radiation patterns: e.g., the spatially averaged reconstruction errors of the conventional and improved SONAH procedures are 15.40 dB and 0.19 dB, respectively, for a monopole simulation and 21.60 dB and 0.19 dB for an infinite-size panel. The wavenumber filter further reduces spatial noise, e.g., decreasing the reconstruction error from 1.73 dB to 0.19 dB for the panel simulation. An existing data measured in a wind tunnel operating at Mach 0.12 is reused for the validation. The locations and radiation patterns of the two loudspeakers are successfully identified from the sound fields reconstructed by using the proposed SONAH procedure.  相似文献   

5.
Sensitivity Encoding (SENSE) is a widely used technique in Parallel Magnetic Resonance Imaging (MRI) to reduce scan time. Reconfigurable hardware based architecture for SENSE can potentially provide image reconstruction with much less computation time. Application specific hardware platform for SENSE may dramatically increase the power efficiency of the system and can decrease the execution time to obtain MR images. A new implementation of SENSE on Field Programmable Gate Array (FPGA) is presented in this study, which provides real-time SENSE reconstruction right on the receiver coil data acquisition system with no need to transfer the raw data to the MRI server, thereby minimizing the transmission noise and memory usage. The proposed SENSE architecture can reconstruct MR images using receiver coil sensitivity maps obtained using pre-scan and eigenvector (E-maps) methods. The results show that the proposed system consumes remarkably less computation time for SENSE reconstruction, i.e., 0.164 ms @ 200 MHz, while maintaining the quality of the reconstructed images with good mean SNR (29 + dB), less RMSE (< 5 × 10 2) and comparable artefact power (< 9 × 10 4) to conventional SENSE reconstruction. A comparison of the center line profiles of the reconstructed and reference images also indicates a good quality of the reconstructed images. Furthermore, the results indicate that the proposed architectural design can prove to be a significant tool for SENSE reconstruction in modern MRI scanners and its low power consumption feature can be remarkable for portable MRI scanners.  相似文献   

6.
陈艳  金伟其  徐超  王霞  高美静  王岭雪 《光子学报》2014,38(8):2155-2159
针对存在不可控微位移的序列低分辨力图像,提出了一种基于2×2不可控微扫描的高分辨力图像重构方法,采用投影法估算出低分辨力图像LR的微位移量,采用基于泰勒级数展开的重构算法由4帧图像重构高分辨力图像.模拟表明:该算法能精确地估计序列图像的帧间位移量并取得较好的重构效果,且算法简单有效可行,处理量小,有利于实现快速处理,在一定程度可满足同步轨道卫星、公安监视等领域对高分辨力成像处理的需求.    相似文献   

7.
《Applied Surface Science》2001,169(1-2):92-98
Self-assembled In0.4Ga0.6As island arrays have been grown on (3 1 1)B GaAs substrates by using atomic hydrogen-assisted molecular beam epitaxy (H-MBE). The evolution process of surface morphology with deposition has been analyzed by atomic force microscopy (AFM) and the development of lateral ordering has been highlighted by two-dimensional fast Fourier transformation (2DFFT) analysis of the AFM images. It is revealed that the InGaAs islands are arranged in nearly perfect two-dimensional (2D) square-like lattice with two sides parallel to [0 1 −1] and [−2 3 3] azimuths. Such an alignment of islands is coincident with the anisotropy of bulk elastic modulus of the GaAs (3 1 1)B substrate.  相似文献   

8.
《Ultrasonics》2013,53(1):36-44
Vibro-acoustography (VA) is a medical imaging method based on the difference-frequency generation produced by the mixture of two focused ultrasound beams. VA has been applied to different problems in medical imaging such as imaging bones, microcalcifications in the breast, mass lesions, and calcified arteries. The obtained images may have a resolution of 0.7–0.8 mm. Current VA systems based on confocal or linear array transducers generate C-scan images at the beam focal plane. Images on the axial plane are also possible, however the system resolution along depth worsens when compared to the lateral one. Typical axial resolution is about 1.0 cm. Furthermore, the elevation resolution of linear array systems is larger than that in lateral direction. This asymmetry degrades C-scan images obtained using linear arrays. The purpose of this article is to study VA image restoration based on a 3D point spread function (PSF) using classical deconvolution algorithms: Wiener, constrained least-squares (CLSs), and geometric mean filters. To assess the filters’ performance on the restored images, we use an image quality index that accounts for correlation loss, luminance and contrast distortion. Results for simulated VA images show that the quality index achieved with the Wiener filter is 0.9 (when the index is 1.0 this indicates perfect restoration). This filter yielded the best result in comparison with the other ones. Moreover, the deconvolution algorithms were applied to an experimental VA image of a phantom composed of three stretched 0.5 mm wires. Experiments were performed using transducer driven at two frequencies, 3075 kHz and 3125 kHz, which resulted in the difference-frequency of 50 kHz. Restorations with the theoretical line spread function (LSF) did not recover sufficient information to identify the wires in the images. However, using an estimated LSF the obtained results displayed enough information to spot the wires in the images. It is demonstrated that the phase of the theoretical and the experimental PSFs are dissimilar. This fact prevents VA image restoration with the current theoretical PSF. This study is a preliminary step towards understanding the restoration of VA images through the application of deconvolution filters.  相似文献   

9.
We investigate the change of higher diffraction order images in holographic image storage and reconstruction process. In experiments, an s-polarized Ar+ laser (488.0 nm) was used to record permanent grating in the dye-doped liquid crystal, 4,4′-n-entylcyanobiphenyl (5CB) doped with 1 wt% methyl-red (MR), at a small incident angle. Higher diffraction order images were observed when the signal beam was focused in front of and behind the film. Then the film was illuminated by an s-polarized He–Ne laser (632.8 nm) in the direction perpendicular to the surface. The higher diffraction order images were reconstructed. A theory about the change of higher diffraction order images is developed, which is in good agreement with experimental results. The results show that the higher diffraction order provides a useful method for optical information processing.  相似文献   

10.
Atomic scale images and low energy electron diffraction pattern of a MoO2(100) single crystal surface are presented, which show different structural modifications depending on surface preparation. A short in-situ heat treatment of the as-grown single crystal results in an atomically ordered surface whose diffraction pattern and STM images are consistent with those expected from the bulk structure. The symmetry of the STM images suggests an oxygen termination of the surface. A significantly longer heat treatment causes a thermodynamically stable (4 × 1) reconstruction which is interpreted to be due to a loss of oxygen chains. The (4 × 1) reconstruction vanishes after Ar-ion-sputtering and subsequent annealing. Additional long sputtering cycles result in a (2 × 1) reconstruction. The observed surface reconstructions can be transformed into each other by heating or sputtering cycles.  相似文献   

11.
《Ultrasonics》2013,53(1):1-16
Synthetic aperture sequential beamforming (SASB) is a novel technique which allows to implement synthetic aperture beamforming on a system with a restricted complexity, and without storing RF-data. The objective is to improve lateral resolution and obtain a more depth independent resolution compared to conventional ultrasound imaging. SASB is a two-stage procedure using two separate beamformers. The initial step is to construct and store a set of B-mode image lines using a single focal point in both transmit and receive. The focal points are considered virtual sources and virtual receivers making up a virtual array. The second stage applies the focused image lines from the first stage as input data, and take advantage of the virtual array in the delay and sum beamforming. The size of the virtual array is dynamically expanded and the image is dynamically focused in both transmit and receive and a range independent lateral resolution is obtained. The SASB method has been investigated using simulations in Field II and by off-line processing of data acquired with a commercial scanner. The lateral resolution increases with a decreasing F#. Grating lobes appear if F#  2 for a linear array with λ-pitch. The performance of SASB with the virtual source at 20 mm and F# = 1.5 is compared with conventional dynamic receive focusing (DRF). The axial resolution is the same for the two methods. For the lateral resolution there is improvement in FWHM of at least a factor of 2 and the improvement at −40 dB is at least a factor of 3. With SASB the resolution is almost constant throughout the range. For DRF the FWHM increases almost linearly with range and the resolution at −40 dB is fluctuating with range. The theoretical potential improvement in SNR of SASB over DRF has been estimated. An improvement is attained at the entire range, and at a depth of 80 mm the improvement is 8 dB.  相似文献   

12.
Experimental parameters used in the annular bright field (ABF) imaging method were tested using images simulated with the multislice method. Images simulated under identical conditions were found to agree well with experimental images. The ABF technique was shown to be relatively insensitive to the sample thickness and the defocus. In experimental ABF images, atomic columns exhibited dark contrast over a wide range of specimen thickness and defocus values, from 10 to 70 nm and ?20 to +20 nm, respectively. A series of diffraction patterns at atomic columns, obtained using the diffraction imaging method, exhibited higher intensities in their central regions (0–11 mrad) for light elements and in their peripheral regions (11–22 mrad) for heavy elements. The results indicated that the contrast of light elements is enhanced by subtraction of the central region of the transmitted beam, since this is blocked by a circular mask in the ABF-STEM technique. Thus, the overall contrast of light elements is greatly improved, allowing them to be clearly visualized.  相似文献   

13.
The atomic structure of sub-monolayer amounts of Ti deposited on the Al(001) surface at room temperature has been investigated using low-energy electron diffraction (LEED) and low-energy ion scattering spectroscopy (LEIS). The Ti coverage was determined using Rutherford backscattering spectroscopy (RBS). Though a crisp LEED image is inherently difficult to obtain, the symmetry of the observed c(2 × 2) LEED images allows us to infer a structure which places Ti atoms in every other Al lattice site. Analysis of the LEIS azimuth- and polar-angle scan spectra has been done to determine the best structural model which supports the c(2 × 2) symmetry of the LEED image as well as LEIS experimental data. It was concluded that the best model consistent with the experimental data, puts Ti preferentially below the surface of the Al substrate at every other lattice site for sub-monolayer coverage of Ti on Al(001). As Ti coverage increases, the presence if Ti atoms in the surface layer also increases. Results of this study are relevant to research pertaining to the possible use of Ti as a catalyst in sodium alanate (NaAlH4) in hydrogen storage applications.  相似文献   

14.
The purpose of this study was to develop a novel magnetic resonance imaging (MRI)-based modeling technique for measuring intervertebral displacements. Here, we present the measurement bias and reliability of the developmental work using a porcine spine model. Porcine lumbar vertebral segments were fitted in a custom-built apparatus placed within an externally calibrated imaging volume of an open-MRI scanner. The apparatus allowed movement of the vertebrae through pre-assigned magnitudes of sagittal and coronal translation and rotation. The induced displacements were imaged with static (T1) and fast dynamic (2D HYCE S) pulse sequences. These images were imported into animation software, in which these images formed a background ‘scene’. Three-dimensional models of vertebrae were created using static axial scans from the specimen and then transferred into the animation environment. In the animation environment, the user manually moved the models (rotoscoping) to perform model-to-‘scene’ matching to fit the models to their image silhouettes and assigned anatomical joint axes to the motion-segments. The animation protocol quantified the experimental translation and rotation displacements between the vertebral models. Accuracy of the technique was calculated as ‘bias’ using a linear mixed effects model, average percentage error and root mean square errors. Between-session reliability was examined by computing intra-class correlation coefficients (ICC) and the coefficient of variations (CV). For translation trials, a constant bias (β0) of 0.35 (± 0.11) mm was detected for the 2D HYCE S sequence (p = 0.01). The model did not demonstrate significant additional bias with each mm increase in experimental translation (β1Displacement = 0.01 mm; p = 0.69). Using the T1 sequence for the same assessments did not significantly change the bias (p > 0.05). ICC values for the T1 and 2D HYCE S pulse sequences were 0.98 and 0.97, respectively. For rotation trials, a constant bias (β0) of 0.62 (± 0.12)° was detected for the 2D HYCE S sequence (p < 0.01). The model also demonstrated an additional bias (β1Displacement) of 0.05° with each degree increase in the experimental rotation (p < 0.01). Using T1 sequence for the same assessments did not significantly change the bias (p > 0.05). ICC values for the T1 and 2D HYCE S pulse sequences were recorded 0.97 and 0.91, respectively. This novel quasi-static approach to quantifying intervertebral relationship demonstrates a reasonable degree of accuracy and reliability using the model-to-image matching technique with both static and dynamic sequences in a porcine model. Future work is required to explore multi-planar assessment of real-time spine motion and to examine the reliability of our approach in humans.  相似文献   

15.
ObjectiveIn this study, we sought to demonstrate the blood suppression performance, image quality and morphological measurements for compressed sensing (CS) based simultaneous 3D black- and gray-blood imaging sequence (CS-siBLAG) in carotid vessel wall MR imaging.Materials and methodsSeven healthy volunteers and five patients were recruited. Healthy subjects underwent five CS-siBLAG scans with 1, 2, 3, 4 and 5-fold accelerations. Signal-to-tissue ratio (STR) and contrast-to-tissue ratio (CTR) were computed as the measures of flowing signal suppression performance and the image quality for black-blood imaging of the technique. Vessel lumen area (LA) and wall area (WA) were compared between fully sampled acquisition and each accelerated acquisition. Patients underwent three CS-siBLAG scans with 1, 3 and 5-fold accelerations as well as a 3D time of flight (3D TOF) scan. Two radiologists reviewed the under-sampled black- and gray-blood image quality.ResultsSTR and CTR values obtained with 2 to 5-fold accelerations were not significantly different from those with full acquisition. LA and WA measured at 2 ×, 3 ×, 4 × and 5 × were all highly correlated to the corresponding values at 1 ×. For patients imaging, two radiologists both found that the dual-contrast images at 3 × acceleration exhibited comparable image quality to that of the fully sampled acquisition, and that the images at 5 × exhibited slightly blurred vessel wall and outer vessel wall boundaries.ConclusionBy combining the CS under-sampling pattern and reconstruction, pseudo-centric phase encoding order and dual blood contrast sequences, this technique provides spatially registered black- and gray-blood images and excellent visualization for vessel wall imaging and gray-blood imaging in a short scan time.  相似文献   

16.
A highly efficient visible wavelength filter enabling a homogeneous integration with an image sensor was proposed and manufactured by employing a standard 90-nm CMOS process. A one dimensional subwavelength Al grating overlaid with an oxide film was built on top of an image sensor to serve as a low-pass wavelength filter; a microlens was then formed atop the filter to achieve beam focusing. The structural parameters for the filter were: a grating pitch of 300 nm, a grating height of 170 nm, and a 150-nm thick oxide overlay. The overall transmission was observed to reach up to 80% in the visible band with a decent roll-off near ~700 nm. Finally, the discrepancy between the observed and calculated result was accounted for by appropriately modeling the implemented metallic grating structure, accompanying an undercut sidewall.  相似文献   

17.
PurposeTo evaluate the use of the double-echo steady-state (DESS) sequence for acquiring high-resolution breast images with diffusion and T2 weighting.Materials and MethodsPhantom scans were used to verify the T2 and diffusion weighting of the DESS sequence. Image distortion was evaluated in volunteers by comparing DESS images and conventional diffusion-weighted images (DWI) to spoiled gradient-echo images. The DESS sequence was added to a standard clinical protocol, and the resulting patient images were used to evaluate overall image quality and image contrast in lesions.ResultsThe diffusion weighting of the DESS sequence can be easily modulated by changing the spoiler gradient area and flip angle. Radiologists rated DESS images as having higher resolution and less distortion than conventional DWI. Lesion-to-tissue contrast ratios are strongly correlated between DWI and DESS images (R = 0.83) and between T2-weighted fast spin-echo and DESS images (R = 0.80).ConclusionThe DESS sequence is able to acquire high-resolution 3D diffusion- and T2-weighted images in short scan times, with image quality that facilitates morphological assessment of lesions.  相似文献   

18.
Total electron yield (TEY) measurement was applied to the scanning photoelectron microscopy (SPEM). The resultant image showed the thickness variation of a zinc overlayer deposited on an iron substrate with 18 nm nominal thickness. The contrast and signal-to-noise ratio of the image were much higher than those of the images obtained by the conventional SPEM. When the order-sorting aperture (OSA) located between the Fresnel zone plate and the sample was biased to +80 V relative to the sample, the contrast of the image was further improved. It also made it possible to perform microscopic X-ray absorption spectroscopy in TEY mode by preventing the unwanted photoelectrons emitted from the OSA, which can cause false TEY, from reaching the sample. Oxidized areas of the iron substrate under the thick zinc overlayer were clearly identified.  相似文献   

19.
In order to estimate the probe size on the specimen surface in a newly developed low-acceleration-voltage (30–60 kV) atomic-resolution scanning transmission electron microscopy (STEM), we compared the intensity profiles of experimentally obtained annular dark field (ADF)-STEM images of Si–Si dumbbells and those of images simulated using a multislice method which takes chromatic aberration into account. However, the simulated ADF images at 30 and 60 kV were found not to match the corresponding experimental images. Subsequently, the simulated images were convolved with probe functions (normal distributions) of different widths until a good match was obtained between the images. This allowed the probe shapes corresponding to the experimental conditions to be determined. ADF-STEM images with chromatic aberration could then be calculated by an incoherent superposition of these probe functions over a range of energies. The full widths at half maximum for the probe functions were estimated to be 99.2 pm for 30 kV and 92.8 pm for 60 kV. The D59 diameters were calculated to be 154.0 pm for 30 kV and 127.8 pm for 60 kV. This means that the 30-kV probe has a larger tail than the 60-kV probe.  相似文献   

20.
Tin (Sn) induced (1 × 2) reconstructions on GaAs(100) and InAs(100) substrates have been studied by low energy electron diffraction (LEED), photoelectron spectroscopy, scanning tunneling microscopy/spectroscopy (STM/STS) and ab initio calculations. The comparison of measured and calculated STM images and surface core-level shifts shows that these surfaces can be well described with the energetically stable building blocks that consist of Sn–III dimers. Furthermore, a new Sn-induced (1 × 4) reconstruction was found. In this reconstruction the occupied dangling bonds are closer to each other than in the more symmetric (1 × 2) reconstruction, and it is shown that the (1 × 4) reconstruction is stabilized as the adatom size increases.  相似文献   