首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
In this study, SPE-CE-ESI-MS is explored for the preconcentration and separation of dilute solutions of six opioid peptides. First, a CE-ESI-MS methodology was developed and validated. LODs of around 1 microg/mL were obtained for all the studied peptides. For SPE-CE-ESI-MS experiments, a home-made SPE microcartridge containing a C18 sorbent was constructed near the inlet of the separation capillary. After optimizing the on-line preconcentration methodology, LODs between 10 and 0.1 ng/mL were achieved. Repeatability, reproducibility, durability of the microcartridges and linearity of the SPE-CE-ESI-MS methodology were also investigated and compared to the values obtained by CE-ESI-MS. Finally, human plasma samples fortified with opioid peptides were analyzed by SPE-CE-ESI-MS in order to show the potential of the methodology for the analysis of biological fluids.  相似文献   

2.
A single step on-line concentration and separation method for peptides in non-aqueous capillary electrophoresis was developed. ACN containing 50 mM tetraethylammonium perchlorate was used as the electrophoretic medium; angiotensins I-IV were separated as a result of the differences in the magnitudes of their interactions with perchlorate anions. When the sample solution (ACN containing 0.5% trifluoroacetic acid and angiotensins) was injected as a large-volume plug, the analytes were concentrated at the inlet end of the capillary by both sweeping and stacking mechanisms; the separation procedure then started automatically without any operations such as polarity change. It was found that the concentration of analytes, injection period, and concentration of tetraethylammonium perchlorate in the electrophoretic medium were important factors for both separation and concentration efficiencies. The angiotensins were concentrated and separated with the large-volume injection of up to 80% of the effective capillary length.  相似文献   

3.
The separation of three selective serotonin reuptake inhibitors (SSRIs) by capillary electrophoresis (CE) with fully integrated solid-phase extraction (SPE) is described. Polymeric monolithic SPE modules were prepared in situ within a fused silica capillary from either butyl methacrylate-co-ethylene dimethacrylate or 3-sulfopropyl methacrylate-co-butyl methacrylate-co-ethylene dimethacrylate. Using a 1 cm SPE module placed at the inlet of the capillary, a mixture of sertraline, fluoxetine and fluvoxamine was extracted from aqueous solution by applying a simple pressure rinse. Under pressure-driven conditions, efficient elution was possible from both SPE materials investigated using 50 mM phosphate buffer, pH 3.5 in acetonitrile (20/80, v/v). Two different strategies were investigated for the efficient elution and subsequent CE separation. Injection of an aqueous sample plug directly into the non-aqueous elution/separation buffer was found to be unsuitable with poor elution profiles observed in the electrodriven mode. Alternatively, a sample plug equivalent to several capillary volumes could be injected by pressure followed by filling the capillary with the non-aqueous elution/separation buffer from the outlet end using a combination of pressure and electrodriven flow. Using a neutral monolith, efficient elution/separation was not possible due to an unstable electroosmotic flow (EOF), however, by adding the ionisable monomer, 3-sulfopropyl methacrylate to the SPE module to increase and stabilise the EOF, it was possible to achieve efficient elution from the SPE module, followed by baseline separation by CE using a 200 mM acetate buffer, pH 3.5 in acetonitrile (10/90, v/v). With enrichment factors of over 500 achieved for each of the analytes this demonstrates the potential of in-line SPE-CE for the sensitive analysis of these drugs.  相似文献   

4.
A sensitive capillary electrophoretic separation method with contactless conductivity detection (C4D) for analysis of five priority haloacetic acids (HAA5) is presented. The analytes were baseline separated in an electrolyte composed of 20 mM 2-(N-Morpholino) ethanesulfonic acid (MES), 20 mM L-histidine (HIS), and 30 μM cetyltrimethylammonium bromide (CTAB) at pH 6.0 in less than 4 min. A simplified solid-phase extraction (SPE) preconcentration procedure on highly cross-linked polystyrene-divinylbenzene (PS-DVB) type sorbent was developed and optimized with respect to short preconcentration time. HAA5 from a 25-mL sample aliquot of tap and swimming pool water could be preconcentrated in less than 5 min using an in-house made SPE column with recoveries ranging from 23 to 98%. Combining the SPE preconcentration procedure with capillary electrophoretic analysis, the attained limits of detection were between 6.1 and 12.2 μg/L with total analysis time of less than 10 min.  相似文献   

5.
The feasibility of using C1-C5 alcohols as electrolyte solutions in nonaqueous capillary zone electrophoresis was investigated. The separation of basic narcotic analgesics and acidic diuretics was modified by changing the alcohol in an electrolyte solution containing alcohol-acetonitrile-acetic acid (50:49:1, v/v) and 20 mM ammonium acetate while other experimental conditions were kept constant. The alcohols studied were methanol, ethanol, 1-propanol, 2-propanol, 1-butanol, 2-butanol, and 1-pentanol. The results indicate that even longer-chain alcohols can be used in nonaqueous capillary zone electrophoresis and, because of the lower currents they allow, they are especially advantageous in wider capillaries. Basic analytes were separated in 200 microm and 320 microm ID capillaries with 1-butanol-acetonitrile-acetic acid (50:49:1, v/v) containing 20 mM ammonium acetate as electrolyte solution. Problems related to the use of wide-bore capillaries are discussed.  相似文献   

6.
In order to enhance the UV detection sensitivity, an application study of an on-line preconcentration technique for micellar electrokinetic chromatographic (MEKC) was carried out. The simultaneous determination of four test ecdysteroids, 20-hydroxyecdysone, ajugasterone C, polypodine B and ponasterone A has been investigated by using the normal stacking mode in MEKC with UV detection. The effects of anionic surfactant composition and concentration, the applied voltage, the pH buffer, the kind and the amount of organic solvent and the injection time on the analyte resolution were evaluated. The optimised conditions for the separation involved the use of a 50 mM borate as the running buffer containing 50 mM of a mixture of sodium dodecyl sulphate (SDS) and sodium cholate (SC) in the ratio of 1:1 together with a concentration of 10% (v/v) of 2-PrOH at pH 9.0. Hydrodynamic injection of 12 s at 50 mbar and separation voltage of 20 kV at temperature of 20 degrees C were employed. These conditions allowed a repeatability separation within 21 min. Concentration detection limit for the neutral analytes studied improve about an order of magnitude. The method was also applied to the determination of ecdysteroids in a real sample.  相似文献   

7.
Capillary electrophoresis (CE) was applied to analyse the long-chain fatty acid composition of vegetable oils, and their degradation products formed upon ageing when drying oils are used as binding media. The analytes were detected with contactless conductivity detection (CCD) and indirect UV absorption, both detectors positioned on-line at the separation capillary. The long-chain fatty acids were resolved in a background electrolyte (BGE) consisting of phosphate buffer (pH = 6.86, 15 mM) containing 4 mM sodium dodecylbenzensulfonate, 10 mM Brij 35, 2% (v/v) 1-octanol and 45% (v/v) acetonitrile. As in this system dicarboxylic analytes, the products of oxidative degradation of unsaturated fatty acids, cannot be determined, a suitable background electrolyte was developed by the aid of computer simulation program PeakMaster. It makes use of a 10 mM salicylic acid, 20 mM histidine buffer, pH 5.85, which combines buffering ability with the optical properties obligatory for indirect UV detection. This buffer avoids system eigenpeaks, which are often impairing the separation efficiency of the system. Separation of the dicarboxylic analytes was further improved by a counter-directed electroosmotic flow (EOF), obtained by dynamically coating the capillary wall with 0.2 mM cetyltrimethylammonium bromide. Long-chain fatty acids and their decomposition products could be determined in recent and aged samples of drying oils, respectively, and in samples taken from two paintings of the 19th century.  相似文献   

8.
This paper describes two different approaches for increasing the sensitivity for the analysis of ceftiofur by capillary electrophoresis (CE). Two different techniques based on the introduction of an enlarged volume of sample, namely large volume sample stacking (LVSS) and in-line solid phase extraction (SPE) were studied and compared. LVSS allowed the on-column electrophoretic preconcentration of ceftiofur without modification of the separation capillary. In-line SPE-CE was developed by using a home-made microcartridge that was filled with a reversed-phase sorbent (C18). The microcartridge was coupled in-line near the inlet of the separation capillary. LVSS and in-line SPE-CE allowed automated operation and improved sensitivity for the analysis of ceftiofur with respect to conventional CE. When environmental water samples were analyzed, an additional pretreatment step based on off-line SPE was necessary in both cases to further decrease the detection limits. In terms of sensitivity for the determination of ceftiofur in river water samples, the combination of off-line SPE with in-line SPE-CE was found the most sensitive with a detection limit of 10 ng L−1, whereas the method based on the use of off-line SPE with LVSS presented a detection limit of 100 ng L−1.  相似文献   

9.
On-line coupling of SPE and CE-MS for peptide analysis   总被引:1,自引:0,他引:1  
An on-line SPE-CE-MS system has been developed for the analysis of peptides. Analytes are preconcentrated using a C(18) microcolumn (5 x 0.5 mm id), and then introduced into the CE system via a valve interface. The CE system with a Polybrene-poly(vinylsulfonate) bilayer coated capillary is combined with an ion-trap mass spectrometer via ESI using a coaxial sheath-liquid sprayer. The on-line coupling of the SPE and CE step by the valve interface is advantageous because it allows an independent functioning of the system parts. Optimization of the SPE-CE system was performed using UV detection. Subsequently, the SPE-CE system has been coupled to the ion-trap mass spectrometer. Test solutions with enkephalin peptides (50 ng/mL) were used for evaluation of system performance. Repeatability of effective mobility and peak area ratio of the two enkephalins were within 1.2% and 9% RSD, respectively. The analysis of 1:1 v/v diluted cerebrospinal fluid samples spiked with enkephalin peptides showed detection limits (S/N = 3) in the range of 1.5-3 ng/mL (around 5 nM), which were similar to those obtained for enkephalin test solutions. Moreover, the potential of the on-line SPE-CE-MS system was demonstrated by the analysis of a cytochrome C digest. Some hydrophilic peptides did not show sufficient retention on the SPE column, and were lost during preconcentration. Nonetheless, positive identification of the protein was achieved, indicating the feasibility of the system for proteomics.  相似文献   

10.
Novel polymer monolith microextraction (PMME) using a poly(methacrylic acid-ethylene glycol dimethacrylate) (poly(MAA-EGDMA)) monolith in conjunction with capillary zone electrophoresis (CZE) was developed for the determination of several angiotensin II receptor antagonists (ARA-IIs) in human urine. The extraction device consisted of a regular plastic syringe (1 mL), a poly(MAA-EGDMA) monolithic capillary (2 cm x 530 microm I.D.) and a plastic pinhead connecting the former two components seamlessly. The extraction was achieved by driving the sample solution through the monolithic capillary tube using a syringe infusion pump, and for the desorption step, an aliquot of organic solvent was injected via the monolithic capillary and collected into a vial for subsequent analysis by CZE. The best separation was realized at 25 kV using a buffer that consisted of 50% acetonitrile and 50% buffer solution (v/v) containing 10 mM disodium hydrogenphosphate (adjusted to pH 2.3 with 1M hydrochloric acid). The method was successfully applied to the determination of telmisartan (T), irbesartan (I) and losartan (L) in urine samples with candesartan (C) as internal standard, yielding the detection limit of 15-20 ng/mL. Close correlation coefficients (R>0.999) and excellent method reproducibility were obtained for all the analytes over a linear range of 0.08-3 microg/mL.  相似文献   

11.
This article presents an overview of the design and application of coupled solid-phase extraction-capillary electrophoresis (SPE-CE) systems that have been reported in the literature between January 2009 and July 2011. The present paper is an update of two previous review papers covering the years 2000-2009 (Electrophoresis 2008, 29, 108-128; Electrophoresis 2010, 31, 44-54). Both in-line and on-line SPE-CE approaches are treated and outlined. Attention is paid to emerging technological developments, such as the use of carbon nanotubes and magnetic particles for on-line extraction of sample components prior to CE analysis. Selected examples illustrate the applicability of SPE-CE in biomedical, pharmaceutical, environmental and food analysis. A full overview of recent SPE-CE studies is given in table format, providing information about sample type, SPE sorbent, coupling mode, detection mode and limit of detection. Finally, some general conclusions and future perspectives are given.  相似文献   

12.
A novel approach for in-line solid-phase extraction capillary electrophoresis (SPE-CE) for basic analytes was developed. The method is based on the use of a weak cation-exchange monolith synthesised in situ in the front end of the CE capillary via photoinitiated polymerization to form poly(methacrylic acid-co-ethylene glycol dimethacrylate), which was used to create the SPE phase in-line with the CE separation capillary. The monolithic SPE material exhibited a surface area of 23.1 m2/g and a capacity of 403 nM for dopamine. Adsorption of the analytes as protonated, cationic species onto the SPE phase was achieved using an electrolyte of 6 mM phosphate and 12 mM sodium ion, buffered at pH 7.0, which is above the pKa of the monolith but below the pKa of the analytes. Elution of the analytes from the SPE phase was achieved using an electrolyte with a pH below that of the pKa of the monolith, namely 12 mM phosphate and 12 mM sodium ion, buffered at pH 3.0. Due to the discontinuous electrolyte combination, analytes were simultaneously eluted and focused as the electrophoretically mobilised pH step boundary moved through the SPE monolith, after which the analytes were separated by conventional CZE in the remainder of the capillary. Quantitative extraction from a solution of 0.5 microg/ml dopamine and epinephrine was achieved when flushing up to 15 column volumes of sample through the capillary. The limits of detection (S/N=3) for dopamine and epinephrine were 3.7 and 4.3 ng/ml, and this method provided a sensitivity enhancement for dopamine of 462 times compared to CZE using hydrodynamic injection. The developed method was used to preconcentrate a test mixture of neurotransmitters comprising dopamine, epinephrine, 5-hydroxytryptamine, metanephrine and also histamine. The applicability of this approach to real life samples was demonstrated by using a urine sample from a healthy person to detect dopamine at sub-ppm levels.  相似文献   

13.
A sensitive and reliable method using capillary zone electrophoresis with UV-diode array detection has been developed and validated for trace determination of residues of sulfonylurea herbicides in environmental water samples and grapes from different origins. The analytes included are triasulfuron, rimsulfuron, flazasulfuron, metsulfuron-methyl, and chlorsulfuron. Optimum separation has been achieved on a 48.5-cm × 50-μm (effective length 40 cm) bubble cell capillary using 90 mM ammonium acetate buffer, pH 4.8, by applying a voltage of 20 kV at 25 °C and using p-aminobenzoic acid as the internal standard. In order to increase sensitivity, large volume sample stacking with polarity switching has been applied as on-line preconcentration methodology. For water samples, a solid-phase extraction (SPE) procedure based on the use of Oasis HLB cartridges was applied for off-line preconcentration and cleanup. For grape samples, the SPE procedure was achieved with C18 sorbent, after extraction of the compounds with MeOH:H2O (1:1) by sonication. The limits of detection for the studied compounds were between 0.04 and 0.12 μg/L for water samples and 0.97 and 8.30 μg/kg in the case of grape samples, lower in all cases than the maximum residue limits permitted by the EU for this kind of food. The developed methodology has demonstrated its suitability for the monitoring of these residues in environmental water and grape samples with high sensitivity, precision, and satisfactory recoveries.  相似文献   

14.
Zhang H  Zhou L  Chen X 《Electrophoresis》2008,29(7):1556-1564
An easy, simple, and highly efficient on-line preconcentration method for polyphenolic compounds in CE was developed. It combined two on-line concentration techniques, large-volume sample stacking (LVSS) and sweeping. The analytes preconcentration technique was carried out by pressure injection of large-volume sample followed by the EOF as a pump pushing the bulk of low-conductivity sample matrix out of the outlet of the capillary without the electrode polarity switching technique using five polyphenols as the model analytes. Identification and quantification of the analytes were performed by photodiode array UV (PDA) detection. The optimal BGE used for separation and preconcentration was a solution composed of 10 mM borate-90 mM sodium cholate (SC)-40% v/v ethylene glycol, without pH adjustment, the applied voltage was 27.5 kV. Under optimal preconcentration conditions (sample injection 99 s at 0.5 psi), the enhancement in the detection sensitivities of the peak height and peak area of the analytes using the on-line concentration technique was in the range of 18-26- and 23-44-fold comparing with the conventional injection mode (3 s). The detection limits for (-)-epigallocatechin (EGC), (-)-epicatechin (EC), (+)-catechin (C), (-)-epigallocatechin gallate (EGCG), and (-)-epicatechin gallate (ECG) were 4.3, 2.4, 2.2, 2.0, and 1.6 ng/mL, respectively. The five analytes were baseline-separated under the optimum conditions and the experimental results showed that preconcentration was well achieved.  相似文献   

15.
SPE coupled in-line to CE, as the strategy to enhance the concentration sensitivity in CE, has been used to enrich naproxen in tap water samples. In this study, a microcartridge containing an octadecyl silica (C18) sorbent was placed near the inlet within the separation capillary column. The optimum conditions were obtained when naproxen in an acidic aqueous solution (pH 3.5) was loaded into the capillary at 930 mbar for 30 min, and 20 mM ammonium acetate in methanol/water (70:30 v/v) was used as both an elution solution and a separation BGE. Under these conditions, the sensitivity was enhanced 1820-fold with respect to normal hydrodynamic injection, and the LOD achieved was 0.2 microg/L. To show the capability of the in-line SPE-CE method, tap water samples were analysed after a pretreatment consisting in an off-line C18-SPE procedure. The recovery of this procedure was higher than 80%. Under these conditions, naproxen could be detected at a concentration of 10 ng/L; so the potential of the procedure for the sensitive analysis of this type of drugs in water samples was demonstrated. Afterwards, these results were compared with those previously obtained for naproxen in water samples using different sample stacking techniques.  相似文献   

16.
A new method for the simultaneous separation of cocaine and four metabolites in urine by CE-ESI-MS via a pressurized nanoliquid junction interface was developed. The resolution of cocaine, cocaethylene, benzoylecgonine, norcocaine, and ecgonine methyl ester was achieved in a polyvinyl-alcohol-coated capillary with 75 μm id × 50 cm total length, using a 15 mM ammonium formate electrolyte solution (pH 9.5) in less than 15 min. In addition, to enhance sensitivity, a field-amplified sample injection (FASI) was evaluated in terms of injection time and sample solvent composition. The limits of detection achieved with the FASI method ranged from 1.5 to 10 ng/mL for all the compounds. The detection of the studied compounds was performed using an ion-trap mass spectrometer in a positive ionization mode. A mixture of methanol:water (80:20 v/v) containing 0.1% v/v of formic acid was employed as spray liquid and delivered at ~200 nL/min. Under optimal CE-MS conditions, linearity was assessed in the concentration range of interest for all analytes with correlation coefficients r2 ≥ 0.9913. Intra- and inter-day precision provided a relative standard deviation lower than 1.54% for migration times and lower than 12.15% for peak areas. Finally, urine samples, spiked with the standard mixture, were extracted using a solid-phase extraction procedure and injected under FASI conditions, providing recoveries from 80% to 94% for all analytes.  相似文献   

17.
An on-line preconcentration method using a polymeric monolithic support is proposed for the retention of the decapeptide angiotensin I and its subsequent analysis by CZE. Monolithic capillary columns were prepared in fused-silica (FS) capillaries of 150 microm id by ionizing radiation-initiated in situ polymerization and cross-linking of diethylene glycol dimethacrylate and glycidyl methacrylate, and chemically modified with iron protoporphyrin IX (Fe-ProP). Monolithic microcolumns (8 mm long) were coupled on-line to the inlet of the separation capillary (FS capillary, 75 microm id x10 cm from the inlet to the microcolumn and 27 cm from the microcolumn to the detector). Angiotensin I was released from the sorbent by a 50 mM sodium phosphate, pH 2.5/ACN, 75:25 v/v solution and then analyzed by CZE with UV absorption detection at 214 nm. The concentration LOQ (CLOQ) was 0.5 ng/mL. The Fe-ProP-derivatized monolithic microcolumn coupled to the separation capillary exhibited a high retention capacity for peptide angiotensin I, and showed as much as 10,000-fold improvement in concentration sensitivity.  相似文献   

18.
Abstract

Fluorescent probes, especially a newly synthesized N-substituted 1-cyanobenz[f]-isoindole quaternary ammonium fluorophore, were used as counter ions in a reaction detector for on-line ion-pair extraction of phenoxyacid herbicides. The probe was used in an on-line post-column set-up coupled to a reversed-phase chromatographic system. After separation on an C-8-bonded silica column using an aqueous methanol (pH 2.5) mobile phase, the herbicides were on-line deprotonated by post-column addition of a 10mM sodium phosphate buffer (pH 8.0), in which the probe was dissolved. Subsequently, the ion-pairs were extracted on-line with chloroform-1-butanol (80:20, v/v) and were monitored by fluorescence detection. Using this system, at least seven herbicides could be separated. The detection limits of 2,4-dichlorophe xyacetic acid and 2,4,5-trichlorophenoxyacetic acid were 400 pg (S/N = 3). The repeatability, based on peak height measurements, for 100ng injections was about 0.5%. Calibration curves were linear over the investigated range of 1–100ng, with correlation coefficients of 0.999 for the two analytes. Application to a drinking water sample is presented.  相似文献   

19.
Zhou L  Wang W  Wang S  Hui Y  Luo Z  Hu Z 《Analytica chimica acta》2008,611(2):212-219
A novel method based on separation by nonaqueous capillary electrophoresis (NACE) combined with laser-induced fluorescence (LIF) detection was developed and compared with classic aqueous modes of electrophoresis in terms of resolution of solutes of interest and sensitivity of the fluorescence detection. Catecholamines derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) were chosen as test analytes for their subtle fluorescence properties. In aqueous systems, capillary zone electrophoresis (CZE) was not suitable for the analysis of test analytes due to complete fluorescence quenching of NBD-labeled catecholamines in neat aqueous buffer. The addition of micelles or microemulsion droplets into aqueous running buffer can dramatically improve the fluorescence response, and the enhancement seems to be comparable for micellar electrokinetic chromatography (MEKC) and microemulsion electrokinetic chromatography (MEEKC). As another alternative, NACE separation was advantageous when performing the analysis under the optimum separation condition of 20 mM sodium tetraborate, 20 mM sodium dodecyl sulfate (SDS), 0.1% (v/v) glacial acetic acid, 20% (v/v) acetonitrile (ACN) in methanol medium after derivatization in ACN/dimethyl sulfoxide (DMSO) (3:2, v/v) mixed aprotic solvents containing 20 mM ammonium acetate. Compared with derivatization and separation in aqueous media, NACE-LIF procedure was proved to be superior, providing high sensitivity and short migration time. Under respective optimum conditions, the NACE procedure offered the best fluorescence response with 5-24 folds enhancement for catecholamines compared to aqueous procedures. In addition, the mechanisms of derivatization and separation in nonaqueous media were elucidated in detail.  相似文献   

20.
Zhu HD  Lü WJ  Li HH  Ma YH  Hu SQ  Chen HL  Chen XG 《Journal of chromatography. A》2011,1218(34):5867-5871
This paper for the first time describes the development of micelle to solvent stacking (MSS) to nonaqueous capillary electrophoresis (NACE). In this proposed MSS-NACE, sodium dodecyl sulfate (SDS) micelles transport, release, and focus analytes from the sample solution to the running buffer using methanol as their solvent. After the focusing step, the focused analytes were separated via NACE. The focusing mechanism and influencing factors were discussed using berberine (BBR) and jatrorrhizine (JTZ) as model compounds. And the optimum condition was obtained as following: 50 mM ammonium acetate, 6% (v/v) acetic acid and 10 mM SDS in redistilled water as sample matrix, 50 mM ammonium acetate and 6% (v/v) acetic acid in pure methanol as the running buffer, -20 kV focusing voltage with 30 min focusing time. Under these conditions, this method afforded limits of detection (S/N=3) of 0.002 μg/mL and 0.003 μg/mL for BBR and JTZ, respectively. In contrast to conventional NACE, the concentration sensitivity was improved 128-153-fold.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号