共查询到20条相似文献,搜索用时 15 毫秒
1.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory. 相似文献
2.
New potential biomarkers for mesterolone misuse in human urine by liquid chromatography quadrupole time‐of‐flight mass spectrometry 下载免费PDF全文
Jianghai Lu María Fernández‐Álvarez Sheng Yang Genye He Youxuan Xu Rodigo Aguilera 《Journal of mass spectrometry : JMS》2015,50(1):153-159
In this paper, mesterolone metabolic profiles were investigated carefully. Mesterolone was administered to one healthy male volunteer. Urinary extracts were analyzed by liquid chromatography quadruple time‐of‐flight mass spectrometry (LC‐QTOFMS) for the first time. Liquid–liquid extraction was applied to processing urine samples, and dilute‐shoot analyses of intact metabolites were also presented. In LC‐QTOFMS analysis, chromatographic peaks for potential metabolites were hunt down by using the theoretical [M–H]? as target ions in full scan experiment, and their actual deprotonated ions were analyzed in targeted MS/MS mode. Ten metabolites including seven new sulfate and three glucuronide conjugates were found for mesterolone. Because of no useful fragment ion for structural elucidation, gas chromatography–mass spectrometry instrumentation was employed to obtain structural details of the trimethylsilylated phase I metabolite released after solvolysis. Thus, their potential structures were proposed particularly by a combined MS approach. All the metabolites were also evaluated in terms of how long they could be detected, and S1 (1α‐methyl‐5α‐androst‐3‐one‐17β‐sulfate) together with S2 (1α‐methyl‐5α‐androst‐17‐one‐3β‐sulfate) was detected up to 9 days after oral administration, which could be the new potential biomarkers for mesterolone misuse. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
3.
Sample‐directed pseudotargeted method for the metabolic profiling analysis of rice seeds based on liquid chromatography with mass spectrometry 下载免费PDF全文
Junjie Zhang Chunxia Zhao Zhongda Zeng Ping Luo Yanni Zhao Jieyu Zhao Lili Li Xin Lu Guowang Xu 《Journal of separation science》2016,39(2):247-255
Rice is one of the most important food crops in the world. Metabolite composition in rice seeds varies significantly depending on genetic variety, climatic alternation and agricultural practice. Metabolomics is a powerful tool to reveal the metabolic response of rice to various conditions. In this work, a rice seed sample‐directed pseudotargeted metabolomics method was first established and validated based on ultra high performance liquid chromatography with triple quadrupole mass spectrometry in the multiple reaction monitoring mode. A total of 749 and 617 ion pairs in positive and negative modes were achieved, respectively. Among them, about 200 metabolites were identified or tentatively identified. The developed method showed better linearity and repeatability than those of non‐targeted metabolomics method. Good intra‐day and inter‐day precisions, recoveries and wide linear range were also obtained. Furthermore, the method was applied for the investigation of metabolic variation of rice seeds with two wild cultivars and their transgenic lines that were grown in two locations. Principal component analysis indicated that the effects of cultivar and location on metabolic variations were far more than those of gene modification. The nonparametric Mann–Whitney U test revealed that most metabolites were influenced by cultivar, location and gene modifications together. 相似文献
4.
New clostebol metabolites in human urine by liquid chromatography time‐of‐flight tandem mass spectrometry and their application for doping control 下载免费PDF全文
Jianghai Lu María Fernández‐Álvarez Sheng Yang Genye He Youxuan Xu R. Aguilera 《Journal of mass spectrometry : JMS》2015,50(1):191-197
In this study, clostebol metabolic profiles were investigated carefully. Clostebol was administered to one healthy male volunteer. Urinary extracts were analyzed by liquid chromatography quadrupole time‐of‐flight mass spectrometry (MS) using full scan and targeted MS/MS techniques with accurate mass measurement for the first time. Liquid–liquid extraction and direct injection were applied to processing urine samples. Chromatographic peaks for potential metabolites were found by using the theoretical [M–H]? as target ion in full scan experiment, and their actual deprotonated ions were analyzed in targeted MS/MS mode. Fourteen metabolites were found for clostebol, and nine unreported metabolites (two free ones and seven sulfate conjugates) were identified by MS, and their potential structures were proposed based on fragmentation and metabolism pathways. Four glucuronide conjugates were also first reported. All the metabolites were evaluated in terms of how long they could be detected and S1 (4ξ‐chloro‐5ξ‐androst‐3ξ‐ol‐17‐one‐3ξ‐sulfate) was considered to be the long‐term metabolite for clostebol misuse detected up to 25 days by liquid–liquid extraction and 14 days by direct injection analysis after oral administration. Five conjugated metabolites (M2, M5, S2, S6 and S7) could also be the alternative biomarkers for clostebol misuse. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
5.
Evaluation of analytical performance and reliability of direct nanoLC‐nanoESI‐high resolution mass spectrometry for profiling the (xeno)metabolome 下载免费PDF全文
Mass spectrometry (MS) profiling techniques are used for analysing metabolites and xenobiotics in biofluids; however, detection of low abundance compounds using conventional MS techniques is poor. To counter this, nanoflow ultra‐high‐pressure liquid chromatography‐nanoelectrospray ionization‐time‐of‐flight MS (nUHPLC‐nESI‐TOFMS), which has been used primarily for proteomics, offers an innovative prospect for profiling small molecules. Compared to conventional UHPLC‐ESI‐TOFMS, nUHPLC‐nESI‐TOFMS enhanced detection limits of a variety of (xeno)metabolites by between 2 and 2000‐fold. In addition, this study demonstrates for the first time excellent repeatability and reproducibility for analysis of urine and plasma samples using nUHPLC‐nESI‐TOFMS, supporting implementation of this platform as a novel approach for high‐throughput (xeno)metabolomics. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
6.
Simultaneous determination of benzene,toluene, ethylbenzene,and xylene metabolites in human urine using electromembrane extraction combined with liquid chromatography and tandem mass spectrometry 下载免费PDF全文
Joon Hyuk Suh Hye Yeon Lee Unyong Kim Han Young Eom Junghyun Kim Hyun‐Deok Cho Sang Beom Han 《Journal of separation science》2015,38(24):4276-4285
For the first time, electromembrane extraction combined with liquid chromatography and tandem mass spectrometry was applied for the determination of urinary benzene, toluene, ethylbenzene, and xylene metabolites. S‐Phenylmercapturic acid, hippuric acid, phenylglyoxylic acid, and methylhippuric acid isomers were extracted from human urine through a supported liquid membrane consisting of 1‐octanol into an alkaline acceptor solution filling the inside of a hollow fiber by application of an electric field. Various extraction factors were investigated and optimized using response surface methodology, the statistical method. The optimum conditions were established to be 300 V applied voltage, 15 min extraction time, 1500 rpm stirring speed, and 5 mM ammonium acetate (pH 10.2) acceptor solution. The method was validated with respect to selectivity, linearity, accuracy, precision, limit of detection, limit of quantification, recovery, and reproducibility. The results showed good linearity (r2 > 0.995), precision, and accuracy. The extract recoveries were 52.8–79.0%. Finally, we applied this method to real samples and successfully measured benzene, toluene, ethylbenzene, and xylene metabolites. 相似文献
7.
Over the last decade, time-of-flight (TOF) instruments have increasingly been used as quantitation tools. In addition, because of their high resolving power, they can be used for verification of empirical formulas. Historically, TOF instruments have had limited quantitation capabilities because of their narrow dynamic range. However, recent advances have improved these limitations. This review covers the rationale for using TOF for LC detection, and describes the many methods currently in the literature for the quantitation of pharmaceuticals, environmental pollutants, explosives and many phytochemicals. 相似文献
8.
Acylglycines play a crucial regulatory and detoxification role in the accumulation of the corresponding acyl CoA esters and are an important class of metabolites in the diagnoses of inborn errors of metabolism. Sensitive quantification of a large number of acylglycines not only improves diagnosis but also enables the discovery of potential new biomarkers of diseases. We report an ultra-high performance liquid chromatography tandem mass spectrometry (UPLC–MS) method for quantifying acylglycines in human urine with high sensitivity. This method is based on the use of a newly developed isotope labeling reagent, p-dimethylaminophenacyl (DmPA) bromide, to label acylglycines to improve detection sensitivity. Eighteen acylglycines, namely acetylglycine, propionylglycine, isobutyrylglycine, butyrylglycine, 4-hydroxyphenylacetylglycine, 2-furoylglycine, tiglylglycine, 2-methybutyrylglycine, 3-methylcrotonylglycine, isovalerylglycine, valerylglycine, hexanoylglycine, phenylacetylglycine, phenylpropionylglycine, glutarylglycine, heptanoylglycine, octanoylglycine and suberylglycine, were measured. This method uses calibration standards prepared in surrogate matrix (un-derivatized urine) and stable-isotope labeled analytes as the internal standards. The analysis was carried out in the positive ion detection mode using multiple reaction monitoring (MRM) survey scans. The calibration curves were validated over the range of 1.0–500 nM. The method achieved a lower limit of quantitation (LLOQ) of 1–5 nM for all analytes, as measured by the standard derivations associated with calibration curves and confirmed in surrogate matrix; the signal-to-noise ratio at LLOQ ranged from 12.50 to 156.70. Both accuracy (% RE or relative error) and precision (% CV) were <15%. Matrix effects were minimized using the surrogate matrix. All eighteen analytes were stable in urine for at least 5 h at room temperature, autosampler (4 °C) for 24 h, 7 weeks at −20 °C and after three freeze/thaw cycles. This surrogate matrix approach was validated using a standard addition experiment. As an example of applications, the endogenous concentrations of all eighteen analytes in urine samples of 20 healthy individuals collected in three consecutive days (i.e., 60 samples) were determined; there was no significant correlation found between the acylglycine profile and gender or body mass indices. 相似文献
9.
建立了同时检测人尿液中7种邻苯二甲酸酯代谢物的高效液相色谱-串联三重四极杆质谱法。尿液经酶水解后,采用萃取柱净化,以2%(v/v)甲酸甲醇溶液为洗脱剂,经苯基柱分离,以0.1%(v/v)乙酸水溶液和0.1%(v/v)乙酸乙腈溶液为流动相进行梯度洗脱,采用电喷雾离子源负离子模式和多反应监测模式采集信号,用同位素内标法进行定量分析。尿液中7种邻苯二甲酸酯代谢物在0.2~200.0 μg/L范围内定量离子的相对峰面积比值与质量浓度均呈良好线性关系(r≥0.99976);检出限(LOD)为13.43~80.21 ng/L,定量限为44.77~267.37 ng/L; 3个水平的加标回收率为88.8%~108.9%,日内和日间精密度均不大于17.05%。该方法可同时准确、灵敏、简便地测定人尿液中7种邻苯二甲酸酯代谢物的暴露水平。 相似文献
10.
We developed an analytical method for a simple, sensitive and simultaneous determination of oxidized nucleosides in urine using column-switching liquid chromatography-electrospray/tandem mass spectrometry (LC-ESI/MS/MS). We connected two columns through a six-way switching valve and effectively separated nucleosides in the urine from the interference by column-switching liquid chromatography. We monitored separated nucleosides using positive ionization tandem mass spectrometry in selective reaction monitoring (SRM) mode. The calibration ranges of nucleosides were 0.2-100 nmol/mL. The linearity of the method was 0.994-0.999, and the limits-of-detection (LOD) at a signal-to-noise (S/N) ratio of 3 were 0.1-0.2 nmol/mL. The coefficients of variation were in the range 2.28-11.74% for within-day variation and 4.36-11.15% for day-to-day variation, respectively. To explore the relationship between breast cancer and the nucleosides level in human urine, we measured the concentrations of nucleosides in female patients with breast cancer (n = 30) and in normal female subjects (n = 30). The concentration of nucleosides was significantly increased in patients with breast cancer when compared with the normal controls (1-methyladenosine; p < 0.005, N(2),N(2)-dimethylguanosine; p < 0.01, 5-hydroxymethyl-2'-deoxyuridine; p < 0.001, 8-hydroxy-2-deoxyguanosine; p < 0.001). Therefore, the elevated levels of nucleosides could be used as an important biomarker for breast-cancer research. 相似文献
11.
Hon Kit Lee Yan Ping Heidi Iu Chi Chung Shek Helene Bendstrup Klinke 《Analytica chimica acta》2009,649(1):80-719
Withdrawal of the support for the REMEDi HS drug profiling system has necessitated its replacement within our laboratories with an alternative broad toxicological screening technique. To this end, a novel method, based on ultra-performance liquid chromatography (UPLC) and time-of-flight (TOF) mass spectrometry, was developed for the routine analysis of urine samples. Identification was achieved by comparison of acquired data to libraries containing more than 300 common drugs and metabolites, and was based on a combination of retention time, exact mass and fragmentation patterns. Validation data for the method is presented and comprised an evaluation of the following parameters: precision; transferability of the methodology between the six collaborating laboratories; specificity; extraction recovery and stability of processed samples; matrix effects and sensitivity.This paper presents the benefits of supplementary fragmentation data with particular regard to increasing specificity and confidence of identification and its usefulness with overdosed samples. The utility of the method was assessed by the parallel analysis of 30 authentic urine samples using the REMEDi HS and UPLC-TOF. The latter provided enhanced detection, leading to the identification of twice as many drugs. Furthermore it did not miss any compounds that were identified by REMEDi HS. The UPLC-TOF findings were further verified by a combination of data from three other conventional screening techniques, i.e., GC-MS, HPLC-DAD and UPLC-MS/MS. 相似文献
12.
Juan C. Domínguez-Romero Juan F. García-Reyes Rubén Martínez-Romero Paula Berton Esther Martínez-Lara María L. Del Moral-Leal Antonio Molina-Díaz 《Analytica chimica acta》2013
The development of comprehensive methods able to tackle with the systematic identification of drug metabolites in an automated fashion is of great interest. In this article, a strategy based on the combined use of two complementary data mining tools is proposed for the screening and systematic detection and identification of urinary drug metabolites by liquid chromatography full-scan high resolution mass spectrometry. The proposed methodology is based on the use of accurate mass extraction of diagnostic ions (compound-dependent information) from in-source CID fragmentation without precursor ion isolation along with the use of automated mass extraction of accurate-mass shifts corresponding to typical biotransformations (non compound-dependent information) that xenobiotics usually undergo when metabolized. The combined strategy was evaluated using LC–TOFMS with a suite of nine sport drugs representative from different classes (propranolol, bumetanide, clenbuterol, ephedrine, finasteride, methoxyphenamine, methylephedrine, salbutamol and terbutaline), after single doses administered to rats. The metabolite identification coverage rate obtained with the systematic method (compared to existing literature) was satisfactory, and provided the identification of several non-previously reported metabolites. In addition, the combined information obtained helps to minimize the number of false positives. As an example, the systematic identification of urinary metabolites of propranolol enabled the identification of up to 24 metabolites, 15 of them non previously described in literature, which is a valuable indicator of the usefulness of the proposed systematic procedure. 相似文献
13.
Moriwaki H Watanabe A Arakawa R Tsujimoto Y Shimizu M Noda T Warashina M Tanaka M 《Journal of mass spectrometry : JMS》2002,37(11):1152-1157
We describe a novel method for the determination of three kinds of dimethylbenzylmercapturic acids (DMM) and six kinds of dimethylhippuric acids (DMH), found in urine as metabolites of trimethylbenzenes, based on liquid chromatography/electrospray ionization tandem mass spectrometry. A solid-phase extraction procedure was used for the extractions of DMM and DMH from a urine sample, and the separation was performed on a reversed-phase C(30) column. The analytes were ionized by electrospray in the positive-ion mode. Operating in the multiple reaction monitoring mode, the linearity of the relative mass spectrometric responses to the internal standard versus analyte concentrations were established in the range 0.1-100 ng ml(-1). The extraction procedure was rapid and the relative standard deviations were below 5%. The detection limits of DMM and DMH in the urine by the proposed method were in the ranges 0.26-0.41 and 0.42-2.0 ng l(-1), respectively. Furthermore, DMM and DMH were detected in a urine sample from an individual who did not suffer from occupational exposure to trimethylbenzenes, by using this method. 相似文献
14.
超高效液相色谱-串联质谱法测定人尿液中全氟有机化合物 总被引:1,自引:0,他引:1
采用超高效液相色谱-串联质谱(UPLC-MS/MS)联用技术,建立了对人尿液中12种全氟有机化合物(PFCs)的分析方法。首先在尿液样品中加入相应的同位素内标,以2%(体积分数)甲酸甲醇溶液超声萃取、离心后,将提取液用弱阴离子交换固相萃取柱净化,采用UPLC-MS/MS测定,内标法定量。12种目标化合物在0.05~50 μg/L质量浓度范围内线性良好,相关系数(r)均大于0.992,检出限在0.44~3.47 ng/L之间。在20、100、500 ng/L添加水平下,平均回收率范围为80.3%~116.2%,相对标准偏差(n=6)在5.5%~13.8%之间。该方法灵敏度高、重现性好、回收率高、操作简单,适合人尿液中PFCs的测定。 相似文献
15.
Structural elucidation of new urinary tamoxifen metabolites by liquid chromatography quadrupole time‐of‐flight mass spectrometry 下载免费PDF全文
Jianghai Lu Chunji He Genye He Xiaobing Wang Youxuan Xu Yun Wu Ying Dong Gangfeng Ouyang 《Journal of mass spectrometry : JMS》2014,49(7):570-578
In this study, tamoxifen metabolic profiles were investigated carefully. Tamoxifen was administered to two healthy male volunteers and one female patient suffering from breast cancer. Urinary extracts were analyzed by liquid chromatography quadruple time‐of‐flight mass spectrometry using full scan and targeted MS/MS techniques with accurate mass measurement. Chromatographic peaks for potential metabolites were selected by using the theoretical [M + H]+ as precursor ion in full‐scan experiment and m/z 72, 58 or 44 as characteristic product ions for N,N‐dimethyl, N‐desmethyl and N,N‐didesmethyl metabolites in targeted MS/MS experiment, respectively. Tamoxifen and 37 metabolites were detected in extraction study samples. Chemical structures of seven unreported metabolites were elucidated particularly on the basis of fragmentation patterns observed for these metabolites. Several metabolic pathways containing mono‐ and di‐hydroxylation, methoxylation, N‐desmethylation, N,N‐didesmethylation, oxidation and combinations were suggested. All the metabolites were detected in the urine samples up to 1 week. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
16.
Profiling of 19-norsteroid sulfoconjugates in human urine by liquid chromatography mass spectrometry
19-Nortestosterone (nandrolone) major metabolites in human urine are excreted as sulfoconjugated and glucuroconjugated forms. A sensitive and selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method in negative ESI mode was developed for direct quantification of 19-norandrosterone sulfate (19-NAS) and 19-noretiocholanolone sulfate (19-NES). For both sulfoconjugates, the [M−H]− ion at m/z 355 and the fragment ion at m/z 97 were used as the precursor and product ions, respectively. The purification method involved a complete and rapid separation of sulfates and glucuronides in two extracts after loading the sample on a weak anion exchange solid phase extraction support (SPE Oasis® WAX). Then, sulfates were separated by LC (Uptisphere® ODB, 150 mm × 3.0 mm, 5 μm) and analyzed on a linear trap and a triple quadrupole mass spectrometer. The lower limit of detection (LLOD) and lowest limit of quantification (LLOQ) were of 100 pg mL−1 and 1 ng mL−1, respectively. Assay validation demonstrated good performances in terms of trueness (92.0-104.9%), repeatability (0.6-7.2%) and intermediate precision (1.3-10.8%) over the range of 1-2500 ng mL−1. Finally, 19-NAS and 19-NES in urine samples collected after intake of 19-norandrostenedione (nandrolone precursor) were quantified. This assay may be easily implemented to separate glucuronide and sulfate steroids from urine specimens prior to quantification by LC/MS/MS. 相似文献
17.
Yu Huang Zhiqiang Liu Shu Liu Fengrui Song Xiuli Hu Yuhua Qin Yongri Jin 《Journal of separation science》2022,45(2):507-517
Dementia is a chronic and multifactor-induced neurodegenerative disorder that occurs frequently in the elderly with weak constitution and insufficient vital energy. However, the relationship between vital energy deficiency and the occurrence and development of dementia is still unclear. In this study, a rat model of dementia with vital energy deficiency was established through intraperitoneal injection with d -galactose and AlCl3 and combined with exhaustive swimming. Changes in the dementia with vital energy deficiency rat model were assessed by examining behaviors, hippocampal histopathological and biochemical parameters, and serum biochemical parameters. Urine metabolomics based on ultra-high-performance liquid chromatography coupled with an orbitrap mass spectrometer was also used to discover endogenous metabolic profile and disease-related biomarkers and investigate the potential mechanism of dementia with vital energy deficiency. Among the 31 potential biomarkers that were identified, nine involved metabolic pathways. The four main types were phenylalanine, tyrosine and tryptophan metabolism, taurine and hypotaurine metabolism, and citrate cycle and pyrimidine metabolism. The pathogenesis of dementia with vital energy deficiency is mainly neurotoxin accumulation and body aging that leads to oxidative stress injury and loss of neuronal protective substances. Vital energy deficiency inhibits the body's energy metabolism and eventually leads to aggravate the dementia. 相似文献
18.
Laura Herrero Sagrario CalvarroMario A. Fernández Jesús Eduardo Quintanilla-LópezMaría José González Belén Gómara 《Analytica chimica acta》2015
Phthalates (PAEs) are ubiquitous toxic chemical compounds. During the last few years, some phthalate metabolites (MPAEs) have been proposed as appropriate biomarkers in human urine samples to determine PAE human intake and exposure. So, it is necessary to have fast, easy, robust and validated analytical methods to determine selected MPAEs in urine human samples. Two different instrumental methods based on gas (GC) and ultra-high performance liquid (UHPLC) chromatography coupled to mass spectrometry (MS) have been optimized, characterized and validated for the simultaneous determination of nine primary and secondary phthalate metabolites in urine samples. Both instrumental methods have similar sensitivity (detection limits ranged from 0.03 to 8.89 pg μL−1 and from 0.06 to 0.49 pg μL−1 in GC–MS and UHPLC–MS2, respectively), precision (repeatability, expressed as relative standard deviation, which was lower than 8.4% in both systems, except for 5OH-MEHP in the case of GC–MS) and accuracy. But some advantages of the UHPLC–MS2 method, such as more selectivity and lower time in the chromatographic runs (6.8 min vs. 28.5 min), have caused the UHPLC–MS2 method to be chosen to analyze the twenty one human urine samples from the general Spanish population. Regarding these samples, MEP showed the highest median concentration (68.6 μg L−1), followed by MiBP (23.3 μg L−1), 5cx-MEPP (22.5 μg L−1) and MBP (19.3 μg L−1). MMP (6.99 μg L−1), 5oxo-MEHP (6.15 μg L−1), 5OH-MEHP (5.30 μg L−1) and MEHP (4.40 μg L−1) showed intermediate levels. Finally, the lowest levels were found for MBzP (2.55 μg L−1). These data are within the same order of magnitude as those found in other similar populations. 相似文献
19.
建立了两性离子亲水作用色谱/质谱联用方法用于大肠杆菌胞内极性代谢物的分离分析。选取52个代表性极性物质对方法进行考察,发现此方法有较好的线性范围,且大部分物质最低检测限均在ng/mL数量级。平行制备6份样品进行分析,结果显示85%以上代谢物峰面积的RSD值小于30%。6个内标物质在低、中、高3个浓度下的日内精密度(RSD)均小于20%,大部分物质的相对回收率都在可接受的范围内(70%~130%)。把此方法用于yfcC基因改造的3株大肠杆菌代谢组分析,发现一些小肽、氨基酸、核苷、有机酸、磷脂等物质在基因改造后发生明显变化。此研究结果表明,建立的两性离子亲水作用色谱/质谱方法检测到的物质化学性质分布广,跨越了极性磷脂到小肽的各个范围,且具有良好的重复性、稳定性和适用性。 相似文献
20.
Xiaoling Su Nan Wang Deying Chen Yunong Li Yingfeng Lu Tao Huan Wei Xu Liang Li Lanjuan Li 《Analytica chimica acta》2016
Human urine and feces can be non-invasively collected for metabolomics-based disease biomarker discovery research. Because urinary and fecal metabolomes are thought to be different, analysis of both biospecimens may generate a more comprehensive metabolomic profile that can be better related to the health state of an individual. Herein we describe a method of using differential chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) for parallel metabolomic profiling of urine and feces. Dansylation labeling was used to quantify the amine/phenol submetabolome changes among different samples based on 12C-labeling of individual samples and 13C-labeling of a pooled urine or pooled feces and subsequent analysis of the 13C-/12C-labeled mixture by LC-MS. The pooled urine and pooled feces are further differentially labeled, mixed and then analyzed by LC-MS in order to relate the metabolite concentrations of the common metabolites found in both biospecimens. This method offers a means of direct comparison of urinary and fecal submetabolomes. We evaluated the analytical performance and demonstrated the utility of this method in the analysis of urine and feces collected daily from three healthy individuals for 7 days. On average, 2534 ± 113 (n = 126) peak pairs or metabolites could be detected from a urine sample, while 2507 ± 77 (n = 63) peak pairs were detected from a fecal sample. In total, 5372 unique peak pairs were detected from all the samples combined; 3089 and 3012 pairs were found in urine and feces, respectively. These results reveal that the urine and fecal metabolomes are very different, thereby justifying the consideration of using both biospecimens to increase the probability of finding specific biomarkers of diseases. Furthermore, the CIL LC-MS method described can be used to perform parallel quantitative analysis of urine and feces, resulting in more complete coverage of the human metabolome. 相似文献