首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In the dairy industry one of the most common frauds is mixing high-value milk (sheep’s and goats’) with milk of lower value (cows’). This illegal practice has commercial, ethical, and serious sanitary consequences because consumers can be exposed to hidden allergens contained in the undeclared cows’ milk. Here, we investigated the possibility of using matrix-assisted laser-desorption/ionization (MALDI)-time of flight (TOF) mass spectrometry (MS) as a rapid, sensitive, and accurate technique for detection of milk adulteration by analysis of phospholipid profiles. Lipid extracts of pure raw milk, commercial milk, and binary mixtures of cows’ and goats’ milk and cows’ and sheep’s milk (the concentrations of each milk varied from 0 % to 50 %) were analyzed with α-cyano-4-chlorocinnamic acid as matrix. The abundance ratio of the ions at m/z 703 and m/z 706 was found to be species-correlated and was used as marker of cows’ milk in sheep’s and goats’ milk. Furthermore, the procedure could potentially be applied to cheese samples, because peaks at m/z 703 and 706 were also found in several commercial cheese samples. This approach proved to be an efficient, rapid, and inexpensive method of detecting milk fraud.
Figure
MALDI-TOF MS analysis of intact phospholipid in milk mixtures  相似文献   

2.
Data-independent mass spectrometry activates all ion species isolated within a given mass-to-charge window (m/z) regardless of their abundance. This acquisition strategy overcomes the traditional data-dependent ion selection boosting data reproducibility and sensitivity. However, several tandem mass (MS/MS) spectra of the same precursor ion are acquired during chromatographic elution resulting in large data redundancy. Also, the significant number of chimeric spectra and the absence of accurate precursor ion masses hamper peptide identification. Here, we describe an algorithm to preprocess data-independent MS/MS spectra by filtering out noise peaks and clustering the spectra according to both the chromatographic elution profiles and the spectral similarity. In addition, we developed an approach to estimate the m/z value of precursor ions from clustered MS/MS spectra in order to improve database search performance. Data acquired using a small 3 m/z units precursor mass window and multiple injections to cover a m/z range of 400–1400 was processed with our algorithm. It showed an improvement in the number of both peptide and protein identifications by 8 % while reducing the number of submitted spectra by 18 % and the number of peaks by 55 %. We conclude that our clustering method is a valid approach for data analysis of these data-independent fragmentation spectra. The software including the source code is available for the scientific community.
Figure
?  相似文献   

3.
Laboratory identification of carbapenemase-producing clinical isolates is crucial to limit the spread of the bacteria. In this study, we shall first develop the matrix-assisted laser desorption ionization–time-of-flight mass spectrometry (MALDI-TOF MS) assay in automatic identification of carbapenemase producers. A total of 143 well-characterized isolates were studied. After an incubation of bacteria with meropenem trihydrate, the mixture was centrifuged and the supernatant analyzed by MALDI-TOF MS. A genetic algorithm model with ClinProTools software was built using spectra of 43 carbapenemase-positive isolates and 40 carbapenemase-negative isolates after 2 h of incubation. This model was externally validated using 60 test isolates. All spectra of supernatants of the carbapenemase-negative isolates showed peak profiles comparable to that of pure meropenem (m/z 384.159, 406.140, and 428.122 of its two sodium salt variants) regardless of the incubation time tested. For the carbapenemase-positive isolates, the specific peak for meropenem at m/z 384.159 disappeared during the incubation time, two products of meropenem degradation were identified with m/z 358.18 (the decarboxylated product) and 380.161 (sodium salt of the decarboxylated product), and other degradation products were observed (native molecule with disrupted amide bond with m/z 402.169, three sodium salt variants with m/z 424.151, 446.133, and 468.115). Sixty test isolates were 100 % correctly classified as carbapenemase positive and carbapenemase negative with the genetic algorithm model. MALDI-TOF MS coupled with ClinProTools is capable of rapidly, accurately, and automatically identifying carbapenemase producers.
Figure
The average spectra of the carbapenemase-positive (red) and carbapenemasenegative isolates (green) were shown. Nine peaks differentiating the two classes are highlighted by arrows. x axis, mass per charge [m/z (in daltons)]; y axis, intensity(arbitrary units [arb.u.]).  相似文献   

4.
An ion mobility/time-of-flight mass spectrometer (IMS/TOF MS) platform that allows for resonant excitation collision induced dissociation (CID) is presented. Highly efficient, mass-resolved fragmentation without additional excitation of product ions was accomplished and over-fragmentation common in beam-type CID experiments was alleviated. A quadrupole ion guide was modified to apply a dipolar AC signal across a pair of rods for resonant excitation. The method was characterized with singly protonated methionine enkephalin and triply protonated peptide angiotensin I, yielding maximum CID efficiencies of 44 % and 84 %, respectively. The Mathieu qx,y parameter was set at 0.707 for these experiments to maximize pseudopotential well depths and CID efficiencies. Resonant excitation CID was compared with beam-type CID for the peptide mixture. The ability to apply resonant waveforms in mobility-resolved windows is demonstrated with a peptide mixture yielding fragmentation over a range of mass-to-charge (m/z) ratios within a single IMS-MS analysis.
Figure
?  相似文献   

5.
Comprehensive multi-dimensional hyphenation of a thermogravimetry device (i.e. a thermobalance) to gas chromatography and single photon ionization–time-of-flight mass spectrometry (TG–GC×SPI–MS) has been used to investigate two crude oil samples of different geographical origin. The source of the applied vacuum ultraviolet radiation is an electron beam pumped rare gas excimer lamp (EBEL). The soft photoionization favors the formation of molecular ions. Introduction of a fast, rapidly modulated gas chromatographic separation step in comparison with solely TG–SPI–MS enables strongly enhanced detection especially with such highly complex organic matrices as crude oil. In contrast with former TG–SPI–MS measurements, separation and identification of overlying substances is possible because of different GC retention times. The specific contribution of isobaric compounds to one mass signal is determined for alkanes, naphthalenes, alkylated benzenes, and other compounds.
Figure
Specific characteristics of a two-dimensional TG–GC×SPI–MS contour plot obtained from Turkish crude oil. The complete m/z and TG temperature ranges are displayed in a. The magnified region from m/z 50–250 and 140–170 °C reveals the “pixilated” structure (b). Parts c and d reveal the system’s ability to investigate compounds in a broad m/z range with limitations for very-high and very-low boiling compounds as shown for m/z 260 and m/z 70, respectively  相似文献   

6.
The need for a routinely applicable assay to measure low estradiol levels in adult men, postmenopausal women, and young adolescents was recently discussed in an Endocrine Society position statement. Our aim was to develop a sensitive liquid chromatography–tandem mass spectrometry method for estradiol and estrone in human serum without the need for derivatization or extended extraction protocols. After protein precipitation of serum with a mixture of methanol/acetonitrile (85/15) (v/v) containing isotopic internal standards (17β-estradiol-16,16,17-d 3 and estrone-2,3,4-13C), we quantified estradiol and estrone by two-dimensional liquid chromatography–tandem mass spectrometry with electrospray ionization in the negative mode monitoring 5?×?271.20→145.00 (17β-estradiol) and 269.20→145.00 (estrone). Sensitivity was increased by using fluoride and summation of 5 identical transitions for estradiol. Our method was analytically validated, compared against direct immunoassays using serum of 25 adult men, and clinically tested by measuring samples of 3 men at baseline and after chemical castration, 30 postmenopausal women and 15 patients receiving aromatase inhibitors. Total imprecision was below 20 % for the low quality controls. Limit of quantification was 1.3 ng/L (4.8 pmol/L) for estradiol and 1.2 ng/L (4.4 pmol/L) for estrone. Estradiol in Certified Reference Material BCR-576 was within specified uncertainty limits. No significant ion suppression or interference was observed. Our method showed modest correlation with direct immunoassay for estradiol (r 2?=?0.64) but no correlation for estrone (r 2?=?0.12). Patient sample results were within expected ranges. In conclusion, we developed a routinely applicable liquid chromatography–tandem mass spectrometry method for estradiol and estrone measurement which is sensitive enough for use in men, postmenopausal women, and young adolescents.
Figure
Chromatogram of E2 in serum with S/N for one MRM and for the summation of 5 identical MRMs  相似文献   

7.
Bacterial products based on Bacillus thuringiensis are registered in many countries as plant protection products (PPPs) and are widely used as insecticides and nematocides. However, certain B. thuringiensis strains produce harmful toxins and are therefore not allowed to be used as PPPs. The serotype B. thuringiensis thuringiensis produces the beta-exotoxin thuringiensin (ßeT) which is considered to be toxic for almost all forms of life including humans (WHO 1999). The use of a non-registered PPP based on B. thuringiensis thuringiensis called bitoxybacillin was established through the determination of ßeT. First, an analytical reference standard of ßeT was characterized by nuclear magnetic resonance, liquid chromatography–high-resolution mass spectrometry and liquid chromatography–tandem mass spectrometry (LC-MS/MS). Then, a confirmatory quantitative method for the determination of ßeT in PPPs and selected greenhouse crops based on LC-MS/MS was developed and validated. A limit of quantitation of 0.028 mg/kg was established, and average recoveries ranged from 85.6 % to 104.8 % with repeatability (RSDr) of 1.5–7.7 % and within-lab reproducibility (RSDWLR) of 17 %. The method was used for analysis of >100 samples. ßeT was found in leaves of ornamentals, but no evidence was found for use in edible crops.
Figure
HMBC NMR spectrum of beta exotoxin thuringiensin  相似文献   

8.
Carboplatin and paclitaxel co-loaded nanovesicles (CPT-PTX-CLV), a novel intravenous formulation void of cremophor EL, may have significant advantages over conventional carboplatin and paclitaxel formulations with respect to tumor targeting, sustained drug release, reduced toxicity, and synergistic efficacy profiles. The aim of this study was to develop and validate a rapid, specific, sensitive, and reliable liquid chromatography–time of flight–mass spectrometry (LC/TOF MS)-based bioanalytical method for the simultaneous quantification of CPT and PTX in a fetal bovine serum (FBS) vehicle containing the dispersed nanovesicles. The analytes were extracted from FBS by simple protein precipitation, with subsequent separation of CPT and PTX on a Waters HPLC SunFire C18 column at a flow rate of 0.25 ml/min using gradient elution mode. The total analytical time was only 12 min. Detection and quantitation was performed by electrospray ionization (ESI) in the positive ionization mode with selective ion monitoring (SIM) at m/z 310.0152 for CPT and 876.3224 for PTX. The calibration curves were linear over the concentration range of 10–4,000 ng/ml for CPT and 5–2,000 ng/ml for PTX (r 2 ?>?0.99), with the respective lower limit of quantification (LLOQ) at 10 and 5 ng/ml. The intra- and inter-day precision and accuracy of analysis of the quality control samples at low, medium, and high concentration levels were ≤13.6 % relative standard deviation (RSD) and ≤14.6 % relative errors (RE). The rapid, sensitive, and reproducible LC/TOF MS method may be used to support preclinical and clinical pharmacological studies of the CPT-PTX-CLV administered by injection in animal and human cancer models.
Figure
Typical SIM chromatograms for the LLOQ samples: carboplatin (upper) at m/z 310.0152 and paclitaxel (lower) at m/z 876.3224.  相似文献   

9.
Apurinic/apyrimidinic (AP) sites are common DNA lesions arising from spontaneous hydrolysis of the N-glycosidic bond and base-excision repair mechanisms of the modified bases. Due to the strong association of AP site formation with physically/chemically induced DNA damage, quantifying AP sites provides important information for risk assessment of exposure to genotoxins and oxidative stress. However, rigorous quantification of AP sites in DNA has been hampered by technical problems relating to the sensitivity and selectivity of existing analytical methods. We have developed a new isotope dilution liquid chromatography–coupled tandem mass spectrometry (LC-MS/MS) method for the rigorous quantification of AP sites in genomic DNA. The method entails enzymatic digestion of AP site-containing DNA by endo- and exonucleases, derivatization with pentafluorophenylhydrazine (PFPH), addition of an isotopically labeled PFPH derivative as internal standard, and quantification by LC-MS/MS. The combination of PFPH derivatization with LC-MS/MS analysis on a triple quadrupole mass spectrometer allows for sensitive and selective quantification of AP sites in DNA at a detection limit of 6.5 fmol, corresponding to 4 AP sites/109 nt in 5 μg of DNA, which is at least ten times more sensitive than existing analytical methods. The protocol was validated by AP site-containing oligonucleotides and applied in quantifying methyl methanesulfonate-induced formation of AP sites in cellular DNA.
Fig
Chemistry of apurinic/apyrimidinic site formation  相似文献   

10.
The extent of internal energy deposition into ions upon storage, radial ejection, and detection using a linear quadrupole ion trap mass spectrometer is investigated as a function of ion size (m/z 59 to 810) using seven ion-molecule thermometer reactions that have well characterized reaction entropies and enthalpies. The average effective temperatures of the reactants and products of the ion-molecule reactions, which were obtained from ion-molecule equilibrium measurements, range from 295 to 350 K and do not depend significantly on the number of trapped ions, m/z value, ion trap q z value, reaction enthalpy/entropy, or the number of vibrational degrees of freedom for the seven reactions investigated. The average of the effective temperature values obtained for all seven thermometer reactions is 318?±?23 K, which indicates that linear quadrupole ion trap mass spectrometers can be used to study the structure(s) and reactivity of ions at near ambient temperature.
Figure
?  相似文献   

11.
Charge detection mass spectrometry (CDMS) measurements have been performed for cytochrome c and alcohol dehydrogenase (ADH) monomer using a modified cone trap incorporating a cryogenically cooled JFET. Cooling the JFET increases its transconductance and lowers thermal noise, improving the signal to noise (S/N) ratio. Single ions with as few as 9 elementary charges (e) have been detected. According to simulations, the detection efficiency for ions with a charge of 13 e is 75 %, and for charges above 13 e the detection efficiency rapidly approaches 95 %. With the low limit of detection achieved here, adjacent charge states are easily resolved in the m/z spectrum, so the accuracy and precision of the image charge measurements can be directly evaluated by comparing the measured image charge to the charge deduced from the m/z spectrum. For ADH monomer ions with 32 to 43 charges, the root mean square deviation of the measured image charge is around 2.2 e. Ions were trapped for over 1500 cycles. The number of cycles detected appears to be limited mainly by collisions with the background gas.
  相似文献   

12.
We describe the implementation and characterization of activated ion electron transfer dissociation (AI-ETD) on a hybrid QLT-Orbitrap mass spectrometer. AI-ETD was performed using a collision cell that was modified to enable ETD reactions, in addition to normal collisional activation. The instrument manifold was modified to enable irradiation of ions along the axis of this modified cell with IR photons from a CO2 laser. Laser power settings were optimized for both charge (z) and mass to charge (m/z) and the instrument control firmware was updated to allow for automated adjustments to the level of irradiation. This implementation of AI-ETD yielded 1.6-fold more unique identifications than ETD in an nLC-MS/MS analysis of tryptic yeast peptides. Furthermore, we investigated the application of AI-ETD on large scale analysis of phosphopeptides, where laser power aids ETD, but can produce b- and y-type ions because of the phosphoryl moiety’s high IR adsorption. nLC-MS/MS analysis of phosphopeptides derived from human embryonic stem cells using AI-ETD yielded 2.4-fold more unique identifications than ETD alone, demonstrating a promising advance in ETD sequencing of PTM containing peptides.
Figure
?  相似文献   

13.
Limonene and its ozone-initiated reaction products were investigated in situ by low temperature plasma (LTP) ionization quadrupole time-of-flight (QTOF) mass spectrometry. Helium was used as discharge gas and the protruding plasma generated ~850 ppb ozone in front of the glass tube by reaction with the ambient oxygen. Limonene applied to filter paper was placed in front of the LTP afterglow and the MS inlet. Instantly, a wide range of reaction products appeared, ranging from m/z 139 to ca. 1000 in the positive mode and m/z 115 to ca. 600 in the negative mode. Key monomeric oxidation products including levulinic acid, 4-acetyl-1-methylcyclohexene, limonene oxide, 3-isopropenyl-6-oxo-heptanal, and the secondary ozonide of limonene could be identified by collision-induced dissociation. Oligomeric products ranged from the nonoxidized dimer of limonene (C20H30) and up to the hexamer with 10 oxygen atoms (C60H90O10). The use of LTP for in situ ozonolysis and ionization represents a new and versatile approach for the assessment of ozone-initiated terpene chemistry.
Figure
?  相似文献   

14.
The gas-phase reactions of the reactive λ 3-phenyl(trifluoromethyl)iodonium (PhI+(III)CF3, 1 at m/z 273) to the radical cation of iodobenzene (PhI?+, 2 at m/z 204) via the loss of ·CF3 and the radical cation of trifluoromethylbenzene (PhCF3 ?+, 3 at m/z 146) via the loss of ·I, were studied by electrospray ionization tandem mass spectrometry (ESI-MS/MS). Interestingly, the gas-phase intramolecular coupling reaction of CF3 with phenyl via the CF3 migration process of 1 at m/z 273 from iodine to the phenyl to give 3 at m/z 146 could only occur according to an intramolecular aromatic substitution mechanism. Density functional theory (DFT) calculations showed that the gas-phase intramolecular aryltrifluoromethylation of 1 at m/z 273 to 3 at m/z 146 occurred via a Meisenheimer complex intermediate (MC), where the triplevalent I center of 1 was reduced to monovalent I. Most importantly, the structure of 3 at m/z 146 derived from 1 at m/z 273 in ESI-MS/MS process was confirmed by comparison of its MS/MS with that of an authentic PhCF3 ?+ at m/z 146 acquired from the electron ionization (EI)-MS/MS analysis of PhCF3. Thus, our studies revealed the intrinsic reactivity tendencies of λ3-phenyl(trifluoromethyl)iodonium under solvent-free conditions.   相似文献   

15.
Trace levels of the veterinary antibiotic compound sulfadiazine (SDZ) can be determined in agricultural drainage water samples with this new method. Optimized sample pretreatment and solid-phase extraction was combined with liquid chromatography coupled to tandem mass spectrometry (SPE LC-MS/MS) using positive electrospray ionization. The linear dynamic range for the LC-MS/MS was assessed from 5 μg/L to 25 mg/L with a 15-point calibration curve displaying a coefficient of correlation r 2?=?0.9915. Agricultural drainage water spiked at a concentration of 25 ng/L gave recoveries between 63 and 98 % (relative standard deviation 15 %), while at 10 ng/L, it showed a lower recovery of 32 % (relative standard deviation 47 %). The final SPE LC-MS/MS method had a limit of detection (LOD)Method and a limit of quantification (LOQ)Method of 7.5 and 23 ng/L agricultural drainage water, respectively. Determination of SDZ, spiked at a realistic concentration of 50 μg/L, in artificial drainage water (ADW) containing common and high levels of phosphate (0.05, 0.5, and 5 mg/L) gave recoveries between 70 and 92 % (relative standard deviation 7.4–12.9 %). Analysis of the same realistic concentration of SDZ in ADW, spiked with common and high levels of dissolved organic carbon (2, 6, and 15 mg/L) confirmed the possible adaptation of a tandem solid-phase extraction (strong anion exchange (SAX)-hydrophilic-lipophilic balance (HLB)) followed by liquid chromatography-tandem mass spectrometry methodology. Recoveries obtained ranged from 104 to 109 % (relative standard deviation 2.8–5.2 %). The new methods enable determination of the veterinary antibiotic compound SDZ in agricultural drainage water from field experiments and monitoring schemes for phosphate- and dissolved organic carbon (DOC)-rich water samples in intensive farming areas.
Figure
Clean-up and up-concentration of sulfadiazine from agricultural drainage water  相似文献   

16.
A sensitive, rapid and reproducible LC–MS/MS method for the determination of olmesartan (OLM), amlodipine (ALM) and hydrochlorothiazide (HCZ) in rat plasma and urine has been developed and validated. Irbesartan (IRB) was used as an internal standard. The analytes were separated on a Waters XTerra-C18 column using gradient elution with acetonitrile and 10 mM ammonium acetate buffer (pH 3.5, adjusted with acetic acid) at a flow rate of 1.0 mL min?1. The three analytes were ionized by positive ion electrospray using multiple-reaction monitoring (MRM) mode to monitor precursor?→?product ion transitions m/z 447.31?→?234.97 for OLM, 408.87?→?238.18 for AML and 290.1?→?204.85 for HCZ. The specificity, matrix effect, recovery, sensitivity, linearity, accuracy, precision, and stabilities were all validated over the concentration range 0.4–100 ng mL?1 for AML, 0.2–100 ng mL?1 for OLM, 0.1–100 ng mL?1 for HCZ. The mean concentrations (Cmax) are 10.32, 587, and 3.4 for OLM, ALM, and HCZ, respectively, by the oral administration of 15 mg kg?1 of each analyte.  相似文献   

17.
An atmospheric pressure laser desorption/ionization mass spectrometry imaging ion source has been developed that combines high spatial resolution and high mass resolution for the in situ analysis of biological tissue. The system is based on an infrared laser system working at 2.94 to 3.10 μm wavelength, employing a Nd:YAG laser-pumped optical parametrical oscillator. A Raman-shifted Nd:YAG laser system was also tested as an alternative irradiation source. A dedicated optical setup was used to focus the laser beam, coaxially with the ion optical axis and normal to the sample surface, to a spot size of 30 μm in diameter. No additional matrix was needed for laser desorption/ionization. A cooling stage was developed to reduce evaporation of physiological cell water. Ions were formed under atmospheric pressure and transferred by an extended heated capillary into the atmospheric pressure inlet of an orbital trapping mass spectrometer. Various phospholipid compounds were detected, identified, and imaged at a pixel resolution of up to 25 μm from mouse brain tissue sections. Mass accuracies of better than 2 ppm and a mass resolution of 30,000 at m/z?=?400 were achieved for these measurements.
Figure
Infrared laser desorption/ionization mass spectrometry imaging provides for direct analysis of biological tissue with a high spatial resolution of 25 μm  相似文献   

18.
Biological tissue imaging by secondary ion mass spectrometry has seen rapid development with the commercial availability of polyatomic primary ion sources. Endogenous lipids and other small bio-molecules can now be routinely mapped on the sub-micrometer scale. Such experiments are typically performed on time-of-flight mass spectrometers for high sensitivity and high repetition rate imaging. However, such mass analyzers lack the mass resolving power to ensure separation of isobaric ions and the mass accuracy for elemental formula assignment based on exact mass measurement. We have recently reported a secondary ion mass spectrometer with the combination of a C60 primary ion gun with a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) for high mass resolving power, high mass measurement accuracy, and tandem mass spectrometry capabilities. In this work, high specificity and high sensitivity secondary ion FT-ICR MS was applied to chemical imaging of biological tissue. An entire rat brain tissue was measured with 150 μm spatial resolution (75 μm primary ion spot size) with mass resolving power (mm 50%) of 67,500 (at m/z 750) and root-mean-square measurement accuracy less than two parts-per-million for intact phospholipids, small molecules and fragments. For the first time, ultra-high mass resolving power SIMS has been demonstrated, with mm 50%?>?3,000,000. Higher spatial resolution capabilities of the platform were tested at a spatial resolution of 20 μm. The results represent order of magnitude improvements in mass resolving power and mass measurement accuracy for SIMS imaging and the promise of the platform for ultra-high mass resolving power and high spatial resolution imaging.
Figure
C60 secondary ion FT-ICR MS provides unprecedented mass resolving power and mass accuracy for SIMS imaging of biological tissue sections. Overlaid selected ion images from rat brain (left) and high spatial resolution imaging of organic dye underneath a TEM grid (right).  相似文献   

19.
An optimised and validated method for the determination of pharmaceutical residues in blue mussels (Mytilus spp.) is presented herein, as well as an investigation of the effect of cooking (by steaming) on any potential difference in human exposure risk. Selected pharmaceuticals included two non-steroidal anti-inflammatory drugs (diclofenac and mefenamic acid), an antibiotic (trimethoprim), an anti-epileptic (carbamazepine) and a lipid regulator (gemfibrozil). An in vivo exposure experiment was set up in the laboratory in which mussels were exposed either directly by injection (10 ng) or daily through spiked artificial seawater (ASW) over 96 h. In liquid matrices, pharmaceutical residues were either determined using liquid chromatography–tandem mass spectrometry (LC-MS/MS) directly, or in combination with solid-phase extraction (SPE) for analyte concentration purposes. The extraction of pharmaceuticals from mussel tissues used an additional pressurised liquid extraction step prior to SPE and LC-MS/MS. Limits of quantification of between 2 and 46 ng L?1 were achieved for extracted cooking water and ASW, between 2 and 64 μg L?1 for ASW in exposure tanks, and between 4 and 29 ng g?1 for mussel tissue. Method linearities were achieved for pharmaceuticals in each matrix with correlation coefficients of R 2?>?0.975. A selection of exposed mussels was also cooked (via steaming) and analysed using the optimised method to observe any effect on detectable concentrations of parent pharmaceuticals present. An overall increase in pharmaceutical residues in the contaminated mussel tissue and cooking water was observed after cooking.
Figure
Pharmaceutical residues in cooked and uncooked marine bivalves  相似文献   

20.
A method for the simultaneous analysis of nucleosides and nucleotides in infant formula using reversed-phase liquid chromatography–tandem mass spectrometry is described. This approach is advantageous for compliance testing of infant formula over other LC-MS methods in which only nucleotides or nucleosides are measured. Following sample dissolution, protein was removed by centrifugal ultrafiltration. Chromatographic analyses were performed using a C18 stationary phase and gradient elution of an ammonium acetate/bicarbonate buffer, mass spectrometric detection and quantitation by a stable isotope-labelled internal standard technique. A single laboratory validation was performed, with spike recoveries of 80.1–112.9 % and repeatability relative standard deviations of 1.9–7.2 %. Accuracy as bias was demonstrated against reference values for NIST1849a certified reference material. The method has been validated for the analysis of bovine milk-based, soy-based, caprine milk-based and hydrolysed milk protein-based infant formulae.
Figure
LC-MS/MS MRM chromatogram of mixed nucleoside and nucleotide standard  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号