首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A solid-phase microextraction (SPME) method was developed for air monitoring of organic solvents frequently used in chemical laboratories (namely pentane, dimethyl ether, acetone, acetonitrile, dichloromethane, hexane, ethylacetate, tetrahydrofurane, cyclohexane, benzene, and toluene). SPME sampling conditions and chromatographic separation were optimised. Linearity of response for each component of the mixture was tested. Standard solutions containing all the compounds, at three different concentrations, were analysed in triplicate and the relative standard deviations (RSDs) were calculated. The method was applied to the monitoring of indoor air in a research chemical laboratory. An SPME fibre was used as a sampling device inside the laboratory. Moreover an SPME fibre was used as a portable sampling device in order to determine the effective human exposure. Comparison of the portable and fixed sampling device showed differences in the amount of solvents associated with activities performed nearby.  相似文献   

2.
This study examined the characteristics of a solid phase microextraction (SPME) assembly as a passive sampler to determine the short-term exposure level (STEL) of methylene chloride. Two types of SPME fibers and six sampling-related factors were chosen and nested in an L(18) Taguchi's orthogonal array. Samples were thermally desorpted and analyzed by gas chromatograph equipped with an electron capture detector (GC/ECD). The use of 85-mum Carboxen/polydimethylsiloxane (Car/PDMS) fibers resulted in greater adsorbed mass, which was highly correlated with the product of concentration and sampling time (r>0.99, p<0.0001), than 85-microm polyacrylate fibers. The sampling rate (SR) of the 85-microm Carboxen/polydimethylsiloxane fibers was not significantly affected by variations in relative humidity (0-80%) and coexistent toluene (none to 100 ppm). Variance of sampling rate was predominantly attributed to the diffusive path length (86.4%) and sampling time (5.7%). With diffusive paths of 3, 10 and 15 mm, the sampling rates of 85-microm Carboxen/polydimethylsiloxane fibers for methylene chloride were 1.4 x 10(-2), 7.7 x 10(-3) and 5.1 x1 0(-3)mL min(-1), respectively. The measured sampling rates were greater than the theoretical values, and decreased with increment of sampling time until they came to constant.  相似文献   

3.
This paper proposes a solid-phase microextraction (SPME) method for the passive sampling and determination of N,N-dimethylacetamide (DMA) and N,N-dimethylformamide (DMF) in air by capillary GC with flame ionization detection. The optimized conditions for SPME method were grab sampling, polydimethylsiloxane/divinylbenzene fiber, extraction for 90 min at 25 +/- 2 degrees C, desorption for 3 min at 220 degrees C, and relative humidity 45 +/- 2%. Under these conditions, the method presented good linearity (R = 0.996), repeatability (%RSD 2.79 and 9.85 for DMF and DMA, respectively), and detection limit (0.021 and 0.024 mg/m3 for DMF and DMA, respectively).  相似文献   

4.
称取美甲贴样品0.0010g置于20mL顶空瓶中,在选定的条件下[孵化温度为36℃,孵化时间为15min,振动器转速为300r·min^-1,固相微萃取(SPME)温度为常温和样品的萃取次数为10次]进行顶空采样和固相微萃取,并将所得挥发性有机物(VOCs,包括所需测定的丙酮、正己烷、乙酸乙酯、乙酸异丙酯、甲苯和乙酸丁酯等6种化合物)引入气相色谱-质谱仪中进行分析。用HP-VOC色谱柱(60m×0.25mm,0.25μm)在40~250℃区间以程序升温模式进行色谱分离,并在电子轰击离子源和选择离子扫描模式等条件下进行质谱测定。采用外标法定量。测得上述6种VOCs的质量在相同的范围(2~250ng)内与其相应的峰面积呈线性关系,其检出限(3.14s)也相同(0.5ng)。以实际样品为基体,在5个浓度水平上加入标准溶液进行回收试验,测得其回收率为80.0%~110%,测定值的相对标准偏差(n=7)为0.030%~5.0%。  相似文献   

5.
Solid-phase microextraction (SPME) with adsorptive Carboxen/PDMS fibre is a powerful sampling device for volatile organic compounds (VOCs) at trace levels in air. However, owing to competitive adsorption, quantification remains a challenging task. In this area, a theoretical model, based on Fick's laws and an extended Langmuir equation, is proposed to deal with the adsorption kinetics of acetone/toluene mixture on SPME fibre under various static extraction conditions. The semipredictive model is first used to determine the axial diffusion coefficients of analytes in the sampling device. The model is then tested with a complex VOC mixture, showing good agreement with experimental data.  相似文献   

6.
Gorlo D  Wolska L  Zygmunt B  Namieśnik J 《Talanta》1997,44(9):1543-1550
A calibration procedure for solid phase microextraction-gas chromatographic (SPME-GC) analysis of organic vapours in air was described in which GC detector (MS in this case) signal is directly related to concentration of analytes of interest sampled by SPME. Gaseous standard mixtures used for the calibration were generated by means of a home-made permeation-type apparatus described elsewhere, W. Janicki et al., Chem. Anal., 38 (1993) 423 and modified to permit easy sampling of analytes on an SPME fibre. To establish sampling parameters, times for equilibrium partitioning of five selected organic compounds (carbon tetrachloride, toluene, chlorobenzene, p-xylene, n-decane) between gaseous mixtures and the fibre (fused silica fibre coated with 100 mum polydimethylsiloxane) were determined. For 10 min sampling time, the detector response and hence amount sampled on the fibre were linear functions of analytes concentration in a gaseous sample.  相似文献   

7.
Field air analysis with SPME device   总被引:5,自引:0,他引:5  
Solid-phase microextraction (SPME) devices were used for a wide scope of air-monitoring including field sampling and analysis of volatile organic compounds (VOCs), formaldehyde, and particulate matter (PM) in air. Grab (instantaneous) and time-weighted average (TWA) sampling were accomplished using exposed and retracted SPME fibers, respectively. Sampling time varied from 1 to 75 min, followed by analysis with a gas chromatograph (GC). A portable GC equipped with unique, in-series detectors: photoionization (PID), flame ionization (FID), and dry electrolytic conductivity (DELCD), provided almost real-time analysis and speciation for common VOCs during an indoor air quality surveys. Indoor air samples collected with SPME devices were compared with those collected using conventional National Institute for Occupational Safety and Health (NIOSH) methods. Air concentrations measured with the SPME device were as low as 700 parts-per-trillion (ppt) for semi-volatile organic compounds. SPME methodology proved to be more sensitive than conventional methods, and provided a simple approach for fast, cost-effective sampling and analysis of common VOCs in indoor air. SPME technology combined with fast portable GC reduced the sampling and analysis time to less than 15 min. The configuration offered the conveniences of immediate on-site monitoring and decision making, that are not possible with conventional methods. In addition, SPME fibers were applied to sampling of particulate matter in diesel engine exhaust. Linear uptake and particulate build-up on the fiber were observed. Preliminary research suggests that SPME fibers could also be applied to sampling of airborne particulate matter.  相似文献   

8.
This article presents the results of an exploratory application of the Solid Phase MicroExtraction (SPME) technique to the analysis of BTEX (benzene, toluene, ethylbenzene and xylenes) at the microg/m3 level in outdoor and indoor air. The salient features of the method validation are reported. As shown by the various examples of field sampling described, SPME technique appears as a method of choice for fast qualitative analysis and quantitative determination of Volatile Organic Compounds (VOC). The small dimensions of the SPME sampling system and the short sampling time let envisage its utilisation for the rapid diagnostic of outdoor and indoor air quality.  相似文献   

9.
The aim of the study was to analyse BTEX compounds (benzene, toluene, ethylbenzene, xylenes) in air by solid phase micro-extraction/gas chromatography/mass spectrometry (SPME/GC/MS), and this article presents the features of the calibration method proposed. Examples of real-world air analysis are given. Standard gaseous mixtures of BTEX in air were generated by dynamic dilution. SPME sampling was carried out under non-equilibrium conditions using a Carboxen/PDMS fibre exposed for 30 min to standard gas mixtures or to ambient air. The behaviour of the analytical response was studied from 0 to 65 g/m3 by adding increasing amounts of BTEX to the air matrix. Detection limits range from 0.05 to 0.1 g/m3 for benzene, depending on the fibre. Inter-fibre relative standard deviations (reproducibility) are larger than 18%, although the repeatability for an individual fibre is better than 10%. Therefore, each fibre should be considered to be a particular sampling device, and characterised individually depending on the required accuracy. Sampling indoor and outdoor air by SPME appears to be a suitable short-delay diagnostic method for volatile organic compounds, taking advantage of short sampling time and simplicity.  相似文献   

10.
固相微萃取-气相色谱/质谱分析栀子花的头香成分   总被引:30,自引:0,他引:30  
刘百战  高芸 《色谱》2000,18(5):452-455
 分别用固相微萃取和动态顶空法分离栀子鲜花的头香成分,用GC/MS技术分析鉴定,并用GC/MS总离子流色谱峰的峰面积进行归一化定量。在固相微萃取方法中,共鉴定了54种化学成分,占总峰面积的99.98%。主要成分(质量分数)依次为金合欢烯(64.86%)、罗勒烯(29.33%)、芳樟醇(2.74%)、惕各酸顺式叶醇酯(1.34%)和苯甲酸甲酯(0.25%)等。经与动态顶空法的分析结果比较发现,固相微萃取法不仅操作简便,而且具有较高的采样灵敏度,获得的化学成分的信息量多于动态顶空法。  相似文献   

11.
Solid-phase dynamic extraction (SPDE) belongs to the most innovative sample preparation and enrichment techniques. However, there is still a lack of knowledge on the fundamentals of SPDE and its applicability in the field of environmental monitoring. A homemade sampling device is constructed to make a detailed study of SPDE kinetics for toluene extraction. It proved that at least 50 aspirating and dispensing cycles were necessary to obtain toluene equilibration between gas and coating phase. A mechanistic model is proposed to explain that in every dispensing step during SPDE, significant losses of retained analytes (up to 48%) occur due to desorption processes. A new accelerated solid-phase dynamic extraction procedure (ASPDE) has been developed that avoids dispensing stages during extraction. The resulting extraction time proves to be 1.7 min, being a reduction by a factor of 37 compared with the SPDE extraction time. ASPDE proved to have high potential in ambient/indoor air monitoring. The limit of detection for toluene was determined to be 56 ppb(v), i.e. a factor of respectively, 6 and 35 lower than obtained with SPME and conventional headspace sampling with gas syringe.  相似文献   

12.
The headspace solid-phase microextraction (HS-SPME) efficiencies from vegetable oil of the recently available Carboxen-poly(dimethylsiloxane) (PDMS) and divinylbenzene-Carboxen-PDMS fibres were found to be much greater than those of the PDMS fibre for a number of volatile contaminants. Using these Carboxen-based fibres, the commonly used HS-SPME equilibration times for aqueous matrices of 30-45 min at room temperature for a number of halogenated and aromatic analytes with volatilities ranging from 1,1-dichloroethylene to hexachlorobenzene were found to be insufficient for the effective extraction of the less volatile analytes from vegetable oil. HS-SPME at 100 degrees C for 45 min, followed by rapid cooling to 0 degrees C with a 10 min continuing extraction, however, significantly increased the SPME efficiencies for the less volatile analytes. Spiking solutions were prepared in vegetable oil instead of methanol as the latter was found to displace analytes from the Carboxen material. Using either of the Carboxen-based fibres and SPME at 100 degrees C, all the target analytes could be determined at low or sub-microg kg(-1) with repeatability < or =10%, even though an equilibrium SPME of the less volatile analytes was not achieved.  相似文献   

13.
In this study, a combination of solid-phase extraction (SPE) and solid-phase microextraction (SPME) has been used to determine chlorobenzenes in air. Analytes were sampled by pumping a known volume of air through a porous polymer (Tenax TA). Then, the adsorbent was transferred into a glass vial and SPME was performed. The quantification was carried out using gas chromatography (GC)-electron-capture detection or GC-MS. Several SPME coatings (100 microm poly(dimethylsiloxane) (PDMS), 75 microm Carboxen (CAR)-PDMS, 65 microm PDMS-divinylbenzene (DVB), 65 microm PDMS-DVB and 85 microm polyacrylate (PA) were evaluated, obtaining the highest responses with Carbowax (CW)- PDMS for the most volatile chlorobenzenes, and with PDMS-DVB or CW-DVB fibers for the semivolatile compounds. To optimize some other factors that could affect the SPME step, a factorial design was used. Kinetic studies of the SPME process were also performed. Concerning the SPE step, breakthrough was studied, showing that 2.5 m3 of air could be processed without losses of the most volatile compounds. The performance of the method was evaluated. External calibration, which does not require the complete sampling process, demonstrated to be suitable, obtaining good linearity (R2 > 0.99) for all chlorobenzenes. Recovery studies were performed at two concentration levels (4 and 40 ng/m3), obtaining quantitative recoveries (>80%). Limits of detection at the sub ng/m3 were achieved for all the target compounds.  相似文献   

14.

Background

A sampling campaign of indoor air was conducted to assess the typical concentration of indoor air pollutants in 8 National Libraries and Archives across the U.K. and Ireland. At each site, two locations were chosen that contained various objects in the collection (paper, parchment, microfilm, photographic material etc.) and one location was chosen to act as a sampling reference location (placed in a corridor or entrance hallway).

Results

Of the locations surveyed, no measurable levels of sulfur dioxide were detected and low formaldehyde vapour (< 18???g?m-3) was measured throughout. Acetic and formic acids were measured in all locations with, for the most part, higher acetic acid levels in areas with objects compared to reference locations. A large variety of volatile organic compounds (VOCs) was measured in all locations, in variable concentrations, however furfural was the only VOC to be identified consistently at higher concentration in locations with paper-based collections, compared to those locations without objects. To cross-reference the sampling data with VOCs emitted directly from books, further studies were conducted to assess emissions from paper using solid phase microextraction (SPME) fibres and a newly developed method of analysis; collection of VOCs onto a polydimethylsiloxane (PDMS) elastomer strip.

Conclusions

In this study acetic acid and furfural levels were consistently higher in concentration when measured in locations which contained paper-based items. It is therefore suggested that both acetic acid and furfural (possibly also trimethylbenzenes, ethyltoluene, decane and camphor) may be present in the indoor atmosphere as a result of cellulose degradation and together may act as an inferential non-invasive marker for the deterioration of paper. Direct VOC sampling was successfully achieved using SPME fibres and analytes found in the indoor air were also identified as emissive by-products from paper. Finally a new non-invasive, method of VOC collection using PDMS strips was shown to be an effective, economical and efficient way of examining VOC emissions directly from the pages of a book and confirmed that toluene, furfural, benzaldehyde, ethylhexanol, nonanal and decanal were the most concentrated VOCs emitted directly from paper measured in this study.  相似文献   

15.
A denuder sampler has been evaluated for a mixture of three gaseous diisocyanates, i.e. toluene diisocyanate (TDI), hexamethylene diisocyanate (HDI) and isophorone diisocyanate (IPDI). Sampling was performed at a total concentration of diisocyanates close to the Swedish occupational exposure limit (OEL), which is 10 ppbv (69-92 microg m(-3)), for a 5-min period. The denuder tube was coated with a chemosorptive stationary phase consisting of SE-30 (polydimethylsiloxane) and the derivatising reagent dibutylamine (DBA). It was shown that the denuder has a collection efficiency for HDI and IPDI comparable to that of an impinger method, while sampling of TDI resulted in an 8% lower concentration. Both short-term (15 min) and long-term (8 h) sampling periods were shown to yield reproducible results. For 8-h measurements, a sampling flow rate of 5 mL min(-1) was shown to be suitable for the investigated concentration range, i.e. 10-100 ppbv (69-921 microg m(-3)). A flow rate of 25 mL min(-1) or higher resulted in breakthrough after 8 h due to chromatography of the compounds in the adsorbent. The limit of detection (LOD) for the air sampling method is nearly 500 times lower than the OEL. The denuder tubes can be prepared at least 10 days prior to sampling without degradation of performance. Furthermore, they can be stored up to 6 days in a freezer after sampling without significant loss of analytes.  相似文献   

16.
A solid-phase microextraction (SPME) sampling method is developed to evaluate indoor exposure to benzene, toluene, ethylbenzene, xylene, and styrene with gas chromatography and flame ionization detection for quantitative analysis. An SPME holder with a 100-pm polydimethylsiloxane (PDMS) and 65-pm PDMS-divinylbenzene fiber coating is tested in different air relative humidity conditions. The method gives good resolution, shows a linear response, is repeatable, and presents high sensitivity. This method is compared with National Institute of Occupational Safety and Health (NIOSH) active sampling.  相似文献   

17.
Furan may be formed in food under heat treatment and is highly suspected to appear in indoor air. The possible exposure to indoor furan raises concerns because it has been found to cause carcinogenicity and cytotoxicity in animals. To determine airborne furan, solid-phase microextraction (SPME) technique was utilised as a diffusive sampler. The Carboxen/Polydimethylsiloxane (CAR/PDMS, 75 μm) fibre was used, and the SPME fibre assembly was inserted into a polytetrafluoroethene tubing. Furan of known concentrations was generated in Tedlar gas bags for the evaluation of SPME diffusive samplers. After sampling, the sampler was inserted into the injection port of a gas chromatograph coupled with a mass spectrometer (GC/MS) for thermal desorption and analysis. Validation of the SPME device with active sampling by charcoal tube was performed side by side as well. The charcoal tube was desorbed by acetone before analysis with GC/MS. The experimental sampling constant of the sampler was found equal to (9.93 ± 1.28) × 10?3 (cm3 min?1) at 25°C. Furthermore, side-by-side validations between SPME device and charcoal tube showed linear relationship with r = 0.9927. The designed passive sampling device for furan has the advantages of both passive sampling and SPME technique and looks suitable for assessing indoor air quality.  相似文献   

18.
Headspace SPME was used to analyse malodorous sulfur compounds in liquid industrial effluents. A pulsed flame photometric detector (PFPD) was selected for a specific and sensitive analysis. Two fibres, PDMS/Dvb and PDMS/Carboxen, which are particularly convenient for extracting small and volatile molecules were tested. To compare these fibres, both sensitivity and artefact formation were considered. The PDMS/Carboxen fibre showed the lower limits of detection and moreover the least artefact formation yields. It was therefore selected and headspace SPME extraction conditions were optimised. Limits of detection of the target compounds evaluated were 12–31 ng L–1 and repeatability was around 7%. Due to the adsorption mechanism involved, extraction is strongly influenced by the sample matrix and the low affinity compounds can suffer displacement effects. To investigate the occurrence of this phenomenon, two sampling times corresponding to non-equilibrium (5 min) and equilibrium conditions (60 min) were investigated. An external calibration was carried out by using standard solutions for both sampling times. The developed procedure was then compared to the standard addition method on a real industrial effluent. The results obtained from the two methods and for the two extraction times were in good agreement, demonstrating that even a long sampling time can be used. Therefore, the simple and timesaving external calibration was defined as relevant for an accurate quantification of sulfur compounds by headspace SPME.  相似文献   

19.
A novel method is firstly presented for field and rapid analysis of short-chain aliphatic amines in water as their pentafluorobenzaldehyde (PFBAY) derivative using solid-phase microextraction (SPME) and portable GC. In the proposed method, short-chain aliphatic amines in water rapidly reacted with PFBAY, and then were headspace extracted and concentrated by SPME. The formed amines derivatives were analyzed by portable GC. The SPME parameters of fiber selection, extraction temperature, extraction time, and stirring rate were studied. The method validations including LOD, recovery, precision, and linearity were studied. It was found that the proposed method required the whole analysis time 22 min, and provided low LOD of 1.2-4.6 ng/mL, good recovery of 91-106%, good precision of RSD value 3.5-9.3%, and linear range 20.0-500 ng/mL (r(2) >0.99). The obtained results demonstrated that the SPME-portable GC is a simple, rapid, and efficient method for the field analysis of short-chain aliphatic amines. Finally, the proposed method was further applied to the quantification of ethylamine, propylamine, and butylamine in environmental water.  相似文献   

20.
Isetun S  Nilsson U 《The Analyst》2005,130(1):94-98
A simple setup for dynamic air sampling using a solid-phase microextraction (SPME) device designed for use in the field was evaluated for organophosphate triester vapour under both equilibrium and non-equilibrium conditions. The effects of varying the applied airflows in the sampling device were evaluated in order to optimise the system with respect to the Reynolds number and magnitude of the boundary layer that developed near the surface. Further, the storage stability of the analytes was studied for both capped and uncapped 100-microm PDMS fibres. Organophosphate triesters are utilized on large scales as flame-retardants and/or plasticizers, for instance in upholstered furniture. In indoor working environments these compounds have become common components in the surrounding air. Measurements were performed in a recently furnished working environment and the concentration of tris(2-choropropyl) phosphate was found to be 7 microg m(-3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号