首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Liu Q  Yuan J  Li Y  Yao S 《Electrophoresis》2008,29(4):871-879
In this paper, we presented the first example of using gemini surfactants as semipermanent coatings in CE for protein separation. These coatings are based on the self-assembly of a series of cationic gemini surfactants, alkanediyl-alpha,omega-bis(dimethylalkylammonium bromide) (m-s-m), on the capillary wall. The coatings can keep stable for a long time without surfactant in the buffer, e.g., after the surfactants were removed from the buffer, the reversed EOF only decreased by 3.6 and 3.9% for 18-2-18 and 16-2-16 coatings over 60 min under continuous electrophoretic conditions. The coating stability increased with the alkyl chain length m. The double long chains of geminis (m > or = 14) yielded a good coating stability; meanwhile, the spacer group acted as an EOF modifier. Thus, this bifunctional surfactant coating provided a new buffer-independent method for EOF control. For 18-s-18 series, the best coating stability and largest EOF were obtained at s = 10. Ranging s from 3 to 10 yielded a linear fine-tuning of EOF and thereby allowed the adjustment of the protein apparent mobility. Highly efficient separation (>500 000 plates/m) was achieved with all the 18-s-18 coatings. Excellent run-to-run and day-to-day reproducibility (RSD of migration time 相似文献   

2.
Yao L  Liu Q  Li Y  Yao S 《Journal of separation science》2011,34(18):2441-2447
Separation of inorganic anions by capillary electrophoresis (CE) is usually conducted in co-electroosmotic mode due to the large electrophoretic mobilities of inorganic anions. Semipermanent surfactant coatings have been shown to be effective for CE of inorganic anions due to their strong capability of electroosmotic flow (EOF) manipulation. However, semipermanent coatings often suffer from their unsatisfactory stability. In addition, organic solvent additives are usually required to adjust the selectivity, which also aggravate the degradation of coating. In this work, a novel semipermanent coating consisting of cationic Gemini surfactant 18-10-18 and nonionic surfactant Tween 20 was developed to separate inorganic anions in CE. This coating is easy to prepare and more stable than pure Gemini coating. The introduction of nonionic surfactant in the coating not only suppresses the reversed EOF but can also adjust the selectivity of separation. Good separations of six model anions were achieved, the separation efficiency was as high as 65040-169700 plates/m and the RSDs of the migration times were less than 0.5 and 2.5% for run-to-run and day-to-day assays, respectively. Calibration curves were linear in the range of 0.05-5.0 mM; the detection limits ranged from 20 to 50 μM. More importantly, no organic solvents are required in the background buffer to achieve the satisfactory separations. This guarantees the coating stability and makes the method greener than most of other methods for CE of inorganic anions.  相似文献   

3.
This report describes the creation of semipermanent capillary coatings that are compatible with organic-water solvent systems in CE. The coatings are created by simply rinsing the fused-silica capillary with long double-chain cationic surfactants, such as dimethyl-ditetradecyl ammonium bromide (2C(14)DAB), dihexadecyldimethyl ammonium bromide (2C(16)DAB), and dimethyldioctadecyl ammonium bromide (2C(18)DAB). These surfactants generate semipermanent bilayer coatings on the capillary surface, which display a high degree of stability in buffers containing up to 60% v/v of organic solvents, such as methanol and ACN. The coating stability increases with increasing hydrophobicity of the surfactant, i.e., with increasing chain length. For instance, the EOF changes by only 1.2% in a 2C(18)DAB-coated capillary after 130 capillary volumes of rinsing with 60% v/v methanol containing buffer. The bilayer coatings allow separations to be performed without the need to regenerate the coating between runs or to maintain the EOF modifier in the run buffer. Rapid separations (<2 min) of anions and basic drugs with migration time reproducibility of less than 0.5% RSD and efficiencies of 0.4-0.6 million plates/m are obtained. In addition, selectivity changes for small anions and cationic drugs are also observed when the organic solvent content is adjusted.  相似文献   

4.
Yang R  Shi R  Peng S  Zhou D  Liu H  Wang Y 《Electrophoresis》2008,29(7):1460-1466
We present cationized hydroxyethylcellulose (cat-HEC) synthesized in our laboratory as a novel physically adsorbed coating for CE. This capillary coating is simple and easy to obtain as it only requires flushing the capillary with polymer aqueous solution. A comparative study with and without polymers was performed. The adsorbed cat-HEC coating exhibited minimal interactions with basic proteins, providing efficient basic protein separations with excellent reproducibility. Under broad pHs, the amine groups are the main charged groups bringing about a global positive charge on the capillary wall. As a consequence, the cat-HEC coating produced an anodal EOF performance. A comparative study on the use of hydroxyethylcellulose (HEC) and cat-HEC as physically adsorbed coatings for CE are also presented. The separation efficiency and analysis reproducibility proved that the cat-HEC polymer was efficient in suppressing the adsorption of basic proteins onto the silica capillary wall. The long-term stability of the cat-HEC coating in consecutive protein separation runs has demonstrated the suitability of the coating for high-throughput electrophoretic protein separations.  相似文献   

5.
CE of biomolecules is limited by analyte adsorption on the capillary wall. To prevent this, monolayer or successive multiple ionic‐polymer layers (SMILs) of highly charged polyelectrolytes can be physically adsorbed on the inner capillary surface. Although these coatings have become commonly used in CE, no systematic investigation of their performance under different coating conditions has been carried out so far. In a previous study (Nehmé, R., Perrin, C., Cottet, H., Blanchin, M. D., Fabre, H., Electrophoresis 2008, 29, 3013–3023), we investigated the influence of different experimental parameters on coating stability, repeatability and peptide peak efficiency. Optimal coating conditions for monolayer and multilayer (SMILs) poly(diallyldimethylammonium) chloride/ poly(sodium 4‐styrenesulfonate) coated capillaries were determined. In this study, the influence of polyelectrolyte concentration and ionic strength of the coating solutions, and the number of coating layers on coating stability and performance in limiting protein adsorption was carried out. EOF magnitude and repeatability were used to monitor coating stability. Coating ability to limit protein adsorption was investigated by monitoring variations of migration times, time‐corrected peak areas and separation efficiency of test proteins. The separation performance of polyelectrolyte coatings were compared with those obtained with bare silica capillaries.  相似文献   

6.
Capillary coatings are crucial for high-quality separation performance in capillary electrophoresis analysis of proteins or peptides as they prevent analyte adsorption at the capillary wall. These coating materials have to fulfill many requirements such as a good separation performance and ensuring a good repeatability. The number of commercially available coating materials is still limited, especially with regard to the charge density on the coating material and the induced electroosmotic flow (EOF) velocity. In this work, we compare the separation performance of the novel self-made cationic capillary coating OHNOON and two commercially available coating materials, the acrylamide based, neutral LN® and the cationic hexadimethrine bromide (Polybrene), using the same coating procedure for all three coating materials. The coatings are investigated regarding the separation efficiency, analyte resolution, coating stability, and migration time stability in tryptic peptide analysis. Good separation performance was confirmed for all three coating materials: all coatings provided high plate numbers of up to 400,000–500,000 and a repeatability of the EOF and the analyte migration times in the range of 1 % relative standard deviation or below. Our results reveal a moderate EOF velocity for the novel OHNOON coating in comparison to the Polybrene coating. We present a detailed discussion of the impact of this reduced EOF velocity and the separation performance. The results presented here will help to define the necessary properties of coating materials to achieve the best compromise between speed of analysis and resolution for the respective application. We show that our novel OHNOON coating is especially valuable for the analysis of low mobility analytes and for samples with a broad range of analyte mobilities.  相似文献   

7.
Luo Z  Wang S  Zhou L  Hu Z 《Talanta》2008,76(2):413-418
In this paper, the long-chained, silanizing agent chloro(dodecyl)dimethylsilane (CDDS) was investigated as a semipermanent coating in micellar electrokinetic capillary chromatography (MEKC). CDDS coating had great stability due to the formation of covalent bonding with the silanol groups on the surface of fused-silica capillary and remained stable for over 100 min after removal of the rinse step of CDDS solution. Anionic surfactant sodium dodecyl sulfate (SDS) could aggregate at this CDDS coating by the hydrophobic group and formed a SDS layer which could increase the electroosmotic flow (EOF). The separation was performed with the running buffer composed of 60mM sodium tetraborate, 12 mM SDS at pH 9.9, with the applied voltage of 20 kV and capillary temperature 25 degrees C. The effect of the coating agent was investigated by the analysis of amino acids. Compared with previous no-coating method, the EOF increases from 4.34 x 10(-4)cm(2)V(-1)s(-1) to 7.02 x 10(-4)cm(2)V(-1)s(-1). Migration time reproducibility was less than 0.97% R.S.D. from run to run and less than 1.56% R.S.D. from day to day.  相似文献   

8.
Protein adsorption to the inner capillary wall hinders the use of kinetic capillary electrophoresis (KCE) when studying noncovalent protein-ligand interactions. Permanent and dynamic capillary coatings have been previously reported to alleviate much of the problems associated with protein adsorption. The characteristic limitations associated with permanent and dynamic coatings motivated us to look at a third type of coating - semipermanent. Here, we demonstrate that a semipermanent capillary coating, designed by Lucy and co-workers, comprised of dioctadecyldimethylammonium bromide (DODAB) and polyoxyethylene (POE) stearate, greatly reduces protein adsorption at physiological pH - a necessary requirement for KCE. The coating (i) does not inhibit protein-DNA complex formation, (ii) prevents the adsorption of the analytes, and (iii) supports an electoosmotic flow required for many applications of KCE. The coating was tested in three physiological buffers using a well-known DNA aptamer and four proteins that severely bind to bare silica capillaries as standards. For every protein, a condition was found under which the semipermanent coating effectively suppresses protein adhesion. While no coating can completely prevent the adsorption of all proteins, our findings suggest that the DODAB/POE stearate coating can have a broad impact on CE at large, as it prevents the absorption of several well studied, highly adhesive proteins at physiological pH.  相似文献   

9.
Modification of capillary electrophoresis (CE) capillaries by poly(hydroxyethyl methacrylate) (poly(HEMA), poly(diethylene glycol monomethacrylate) (poly(DEGMA) and poly(triethylene glycol monomethacrylate) (poly(TEGMA), was studied. Methods based on physical adsorption of the modifier and on its chemical binding were compared on the basis of the electroosmotic flow (EOF) reproducibility, the EOF dependence on the pH, the symmetry of the peak of positively charged tyramine, the stability of the coating and the separation of standard and milk proteins in the modified capillaries. Reproducible coatings were obtained by chemical binding of the polymers to the capillary walls and by coating with a solution of a polymer, as also demonstrated by the atomic force microscopy.  相似文献   

10.
Separation of atropisomers of analogues of the anti-hepatitis drug dimethyl diphenyl bicarboxylate (DDB) by capillary electrophoresis with vancomycin as the chiral selector is described. Among several tested chiral selectors, including various cyclodextrin derivatives as well as vancomycin, only the latter displayed the enantioselectivity to the studied atropisomers. However, relatively poor separation efficiency was obtained due to the adsorption of vancomycin on the capillary wall. This problem was overcome by modifying the capillary wall with a polycationic electrolyte named hexadimethrine bromide (HDB) to produce a positively charged coating, which minimized the adsorption of vancomycin on the capillary wall by electrostatic repulsion. Moreover, the positively charged coating could shorten the separation time by reversing the EOF because the reversed EOF migrated to the same direction as the negatively charged analyte. Effects of buffer pH, vancomycin and buffer concentrations and applied voltage on the separation were investigated and the optimal conditions were established as follows: 40 mM Tris-phosphate buffer (pH 6.0) containing 6.0 mM vancomycin and 0.001% HDB. Baseline separation of three racemic DDB analogues was obtained within 12 min under the optimal conditions.  相似文献   

11.
Capillary electrophoretic separations of inorganic anions are performed using a capillary coated with a mixture of the cationic surfactant didodecyldimethylammonium bromide (DDAB) and the zwitterionic surfactant 1,2-dilauroyl-sn-phosphatidylcholine (DLPC). These double-chained surfactants form semi-permanent coatings on the capillary wall, which allows the excess surfactant to be removed from the buffer prior to separation. Interactions between surfactant aggregates in the buffer and analyte anions are thus eliminated. The electroosmotic flow (EOF) can be altered from fully reversed (100% DDAB) to near zero (100% DLPC) using different ratios of DDAB and DLPC. Controlling the EOF allows for improved resolution of the anions while maintaining a rapid, co-EOF separation, free from analyte-surfactant additive interactions.  相似文献   

12.
Wang C  Lucy CA 《Electrophoresis》2004,25(6):825-832
Mixtures of the cationic surfactant cetyltrimethylammonium bromide (CTAB) with the anionic surfactant sodium dodecyl sulfate (SDS) form more stable coatings in fused-silica capillaries than CTAB alone. The reversed electroosmotic flow (EOF) generated by CTAB/SDS mixtures remains stable for over 80 min after removal of the surfactants from the buffer. Enhanced stability (relative to CTAB alone) was found even when the ratio of SDS to CTAB was as low as 1%. This greater coating stability is attributed to the structural transition from adsorbed micelle to bilayer, which is induced by addition of SDS. Separation of a mixture of basic proteins yielded efficiencies of 364 000-562 000 plates/m and recoveries ranging from 85% to 98%. Migration time reproducibility was less than 0.9% relative standard deviation (RSD) from run to run and less than 2.6% RSD from day to day.  相似文献   

13.
Capillary electrophoresis (CE) provides a new analytical tool for the separation of proteins, and almost all traditional modes of electrophoresis can be carry out in CE. But serious adsorption of proteins on capillary wall prohibited the proper separation. Three main approaches are used to overcome adsorption and control electroosmotic flow, (1) buffer of high or low pH,high salt concentration and additives, (2) pre-adsorption of neutral or charged macromolecules on the capillary wall and (3) chemically bonded coatings which are expected to give the best shield of silanol groups present on bare silica by vaious hydrophilic polymers. Capillaries coated with linear polyacrylamide represent the most successful approach available to date. Cross-linkage of polyacrylamide coating is desired to increase its stability.  相似文献   

14.
G Azadi  A Tripathi 《Electrophoresis》2012,33(14):2094-2101
Control of EOF in microfluidic devices is essential in applications such as protein/DNA sizing and high‐throughput drug screening. With the growing popularity of poly(methyl methacrylate) (PMMA) as the substrate for polymeric‐based microfludics, it is important to understand the effect of surfactants on EOF in these devices. In this article, we present an extensive investigation exploring changes in EOF rate induced by SDS, polyoxyethylene lauryl ether (Brij35) and CTAB in PMMA microfluidic capillaries. In a standard protein buffer (Tris‐Glycine), PMMA capillaries exhibited a cathodic EOF with measured mobility of 1.54 ± 0.1 (× 10?4 cm2/V.s). In the presence of surfactant below a critical concentration, EOF was independent of surfactant concentration. At high concentrations of surfactants, the electroosmotic mobility was found to linearly increase/decrease as the logarithm of concentration before reaching a constant value. With SDS, the EOF increased by 257% (compared to buffer), while it was decreased by 238% with CTAB. In the case of Brij35, the electroosmotic mobility was reduced by 70%. In a binary surfactant system of SDS/CTAB and SDS/Brij35, addition of oppositely charged CTAB reduced the SDS‐induced EOF more effectively compared to nonionic Brij35. We propose possible mechanisms that explain the observed changes in EOF and zeta potential values. Use of neutral polymer coatings in combination with SDS resulted in 50% reduction in the electroosmotic mobility with 0.1% hydroxypropyl methyl cellulose (HPMC), while including 2% poly (N,N‐dimethylacrylamide) (PDMA) had no effect. These results will potentially contribute to the development of PMMA‐based microfluidic devices.  相似文献   

15.
A brush-like copolymer consisting of poly(ethylene glycol) methyl ether methacrylate and N,N-dimethylacrylamide (PEGMA-DMA) was synthesized and used as a novel static physically adsorbed coating for protein separation by capillary electrophoresis for the first time, in order to stabilize electroosmotic flow (EOF) and suppress adsorption of proteins onto the capillary wall. Very stable and low EOF was obtained in PEGMA-DMA-coated capillary at pH 2.2-7.8. The effects of molar ratio of PEGMA to DMA, copolymer molecular mass, and pH on the separation of basic proteins were discussed. A comparative study of bare capillary with PEGMA-DMA-coated capillary for protein separation was also performed. The basic proteins could be well separated in PEGMA-DMA-coated capillary over the investigated pH range of 2.8-6.8 with good repeatability and high separation efficiency because the copolymer coating combines good protein-resistant property of PEG side chains with excellent coating ability of PDMA-contained backbone. Finally, the coating was successfully applied to the fast separation of other protein samples, such as protein mixture and egg white, which reveals that it is a potential coating for further proteomics analysis.  相似文献   

16.
Control of the electroosmotic flow (EOF) is critical for achieving optimal separations by capillary electrophoresis. For instance, manipulation of the EOF can yield either high resolution separations or rapid analyses. Dynamic capillary coatings are a simple and cost-effective approach to altering the EOF. The normal EOF can be slowed using buffer additives such as Mg2+ and hexamethonium which ion exchange onto the surface silanols to lower the effective wall charge. Alternatively, cationic polyelectrolytes or cationic surfactants can be used to establish a cationic coating on the capillary wall, which results in a reversed EOF. Practical considerations such as pH stability and reproducibility obtainable with an EOF modifier will be discussed.  相似文献   

17.
The use of mixtures of ionic and zwitterionic surfactants in poly(dimethylsiloxane) (PDMS) microchips is reported. The effect of surfactant concentration on electroosmotic flow (EOF) was studied for a single anionic surfactant (sodium dodecyl sulfate, SDS), a single zwitterionic surfactant (N-tetradecylammonium-N,N-dimethyl-3-ammonio-1-propanesulfonate, TDAPS), and a mixed SDS/TDAPS surfactant system. SDS increased the EOF as reported previously while TDAPS showed an initial increase in EOF followed by a reduction at higher concentrations. When TDAPS was added to a solution containing SDS, the EOF decreased in a concentration-dependent manner. The EOF for all three surfactant systems followed expected pH trends, with increasing EOF at higher pH. The mixed surfactant system allowed tuning of the EOF across a range of pH and concentration conditions. After establishing the EOF behavior, the adsorption/desorption kinetics were measured and showed a slower adsorption/desorption rate for TDAPS than SDS. Finally, the separation and electrochemical detection of model catecholamines in buffer and reduced glutathione in red blood cell lysate using the mixed surfactant system were explored. The mixed surfactant system provided shorter analysis times and/or improved resolution when compared to the single surfactant systems.  相似文献   

18.
Wei W  Ju H 《Electrophoresis》2005,26(3):586-592
A zwitterionic surfactant, dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium (C12H25N+(CH3)2CH2CHOHCH2SO3-), named dodecyl sulfobetaine (DSB), was used as a novel modifier to coat dynamically capillary walls for capillary electrophoresis separation of basic proteins. The DSB coating suppressed the electroosmotic flow (EOF) in the pH range of 3-12. At high DSB concentration, the EOF was suppressed by more than 8.8 times. The DSB coating also prevented successfully the adsorption of cationic proteins on the capillary wall. Anions, such as Cl-, Br-, I-, SO4(2-), CO3(2-), and ClO4-, could be used as running buffer modifiers to adjust the EOF for better separation of analytes. Using this dynamically coated capillary, a mixture of eight inorganic anions achieved complete separation within 4.2 min with the efficiencies from 24,000 to 1,310,000 plates/m. In the presence of ClO4- as EOF adjustor, the separation of a mixture containing four basic proteins (lysozyme, cytochrome c, alpha-chymotrypsinogen A, and myoglobin) yielded efficiencies of 204,000-896,000 plates/m and recoveries of 88%-98%. Migration time reproducibility of these proteins was less than 0.5% relative standard deviation (RSD) from run to run and less than 3.1% RSD from day to day, showing promising application of this novel modifier in protein separation.  相似文献   

19.
To stabilize electroosmotic flow (EOF) and suppress protein adsorption onto the silica capillary inner wall, a cationic hydroxyethylcellulose-graft-poly (poly(ethylene glycol) methyl ether methacrylate) (cat-HEC-g-PPEGMA) graft copolymer composed of cationic backbone and bottle brush-like side chains was synthesized for the first time and used as a novel physically adsorbed coating for protein separation by capillary electrophoresis. Reversed (anodal) and very stable EOF was obtained in cat-HEC-g-PPEGMA-coated capillary at pH 2.2-7.8. The effects of degree of cationization, PEGMA grafting ratio, PEGMA molecular mass, and buffer pH on the separation of basic proteins were investigated. A systematic comparative study of protein separation in bare and HEC-coated capillaries and in cat-HEC-g-PPEGMA-coated capillary was also performed. The basic proteins can be well separated in cat-HEC-g-PPEGMA-coated capillary over the pH range of 2.8-6.8 with good repeatability and high separation efficiency, because the coating combines good protein-resistant property of bottle brush-like PPEGMA side chains with excellent coating ability of cat-HEC backbone. Besides its success in separation of basic proteins, the cat-HEC-g-PPEGMA coating was also superior in the fast separation of other protein samples, such as protein mixture, egg white, and saliva, which indicates that it is a promising coating for further proteomics analysis.  相似文献   

20.
Summary Capillary zone electrophoresis has been developed for the separation of seed albumins fromVicia faba using both uncoated and polyoxyethylene ether (Brij-35) coated octadecysilane derivatized capillaries. Optimal separation conditions were found by studying the effect of pH, buffer composition and applied voltage. The nonionic surfactant/C18 coated capillary significantly reduced albumin adsorption and electroosmotic flow (EOF). A gradual washing out of the surfactant from the coated capillary during use altered not only the magnitude of the EOF, but also its reproducibility. The introduction of hydrophilic polymer solutions between analyses for dynamic modification of the Brij/C18 coated capillary surface prevented desorption of coating material, allowed optimization of resolution and ensured stability of the EOF. CE with surface-modified capillaries was then used to compare seed albumin profiles of severalVicia species. This technique appears to provide a powerful tool for use in taxonomic investigations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号