首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This review covers theoretical principles and experimental procedures for the determination of gas-liquid partition coefficients, KL, by gas chromatography. In order to precisely define the relationship between KL, retention time and experimental parameters, the retention theory, both for ideal and for imperfect gas phase, is expounded. The most important sources of systematic error, as peak asymmetry, mixed retention mechanisms, column hold-up time and stationary phase mass determination, are discussed. Although the review is focussed on packed columns, comparison to capillary columns is discussed in those aspects in which these last show advantages.  相似文献   

2.
A rapid, efficient and low-cost headspace technique useful for the determination of liquid/gas partition coefficients of gases and volatile substances of low and intermediate solubility is described. The equilibration step is carried out at constant pressure using glass syringes, with a ratio of liquid/gas phase volumes of ca. 1:3; after 30 min at the desired temperature, the headspace is recovered by transfer into another syringe and analyzed by gas chromatography. A study of the partition coefficients in water at 37 degrees C of 27 volatile compounds demonstrated that the method is fully applicable for all gases, with exception of those with a partition coefficient higher than 300.  相似文献   

3.
Curie-point pyrolysis with a relatively low resolution gas—liquid chromatographic system (packed Carbowax 20M columns) provided data on washed cells of oral streptococci. When the data were ordered into a hierarchy of comparisons the steps were matched not only by the increase in variability between sets but also by the proportion of the output showing relatively high variability. It was possible to segregate strains of Streptococcus mutans serotype c from those of different serotypes by use of a discriminant function derived from only three pyrogram peaks.  相似文献   

4.
The method to predict 1-octanol-water partition coefficients (K ow) from capacity factors (k) obtained by Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) has been extended to use gradient elution rather than isocratic elution. The mobile phase has been changed either linearly or exponentially with time. The initial composition of the mobile phase and its rate of change affected the log K ow versus log k relation. This relation was exponential in linear gradient experiments. For non-linear gradient elution in which the water fraction of the mobile phase decreased exponentially from 100% to approach 0% asymptotically, a physically-based equation describing the dependence of log K ow on log k has been derived. Without any preliminary estimation, RP-HPLC gradient elution allows a precise prediction of log K ow over a range of nearly six orders of magnitude.  相似文献   

5.
梁超  乔俊琴  韩艺源  练鸿振 《色谱》2016,34(12):1240-1249
通过反相高效液相色谱法系统地考察了中性和弱酸性化合物在新型胆固醇基键合相色谱柱(Cholester柱)上的保留行为。以甲醇和乙腈为有机调节剂,建立了保留因子(k)与有机调节剂比例(φ)间的关系,并外推获取100%水相为流动相时的log kw;同时进一步建立并验证了不同流动相下正辛醇/水分配系数的对数(log Kow)和log kφ(log kw)间的模型,并预测了部分化合物的log Kow。结果表明,使用Cholester柱测定log Kow时,甲醇比乙腈更适合作为有机调节剂;对中性化合物和中性状态的酸性化合物,可以用任意甲醇比例下获取的log kφ预测log Kow;对存在离解的酸性化合物,依然用外推方式获取的log kw预测log Kow。将采用Cholester柱与文献中采用C18柱、C8柱建立的log Kow-log kφ模型进行对比,结果表明化合物与胆固醇基键合相存在特别的作用。  相似文献   

6.
We describe a novel two-dimensional liquid chromatography (2D-LC) method for fast and robust isolation and concentration of low abundant carbohydrates (sorbitol, glycerol) from biological matrices (plasma and urine). Off-line pre-purified fractions, enriched by analyte of interest, were analyzed by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS-MS). Initial 2D-LC automated sample pre-purification improved MS detection, eliminated matrix effects, and achieved high sensitivity (picogram detection limit) with a 6 min runtime and increased column lifetime. Using this method we have analyzed more than 1300 samples from biological matrices without column replacement.  相似文献   

7.
To avoid the limitation of the widely used prediction methods of soil organic carbon partition coefficients (KOC) from hydrophobic parameters, e.g., the n-octanol/water partition coefficients (KOW) and the reversed phase high performance liquid chromatographic (RP-HPLC) retention factors, the soil column liquid chromatographic (SCLC) method was developed for KOC prediction. The real soils were used as the packing materials of RP-HPLC columns, and the correlations between the retention factors of organic compounds on soil columns (ksoil) and KOC measured by batch equilibrium method were studied. Good correlations were achieved between ksoil and KOC for three types of soils with different properties. All the square of the correlation coefficients (R2) of the linear regression between log ksoil and log KOC were higher than 0.89 with standard deviations of less than 0.21. In addition, the prediction of KOC from KOW and the RP-HPLC retention factors on cyanopropyl (CN) stationary phase (kCN) was comparatively evaluated for the three types of soils. The results show that the prediction of KOC from kCN and KOW is only applicable to some specific types of soils. The results obtained in the present study proved that the SCLC method is appropriate for the KOC prediction for different types of soils, however the applicability of using hydrophobic parameters to predict KOC largely depends on the properties of soil concerned.  相似文献   

8.
Narrow-bore column liquid chromatography coupled on-line with capillary gas chromatography (LC/GC) is used for the determination of polychlorinated biphenyls (PCBs) in sediment via a heart-cutting technique. This method is compared with a method in which two off-line column clean-up steps are used with subsequent analysis by capillary gas chromatography. For the LC/GC analysis the recovery of PCBs was 90–100%. For two sediment samples from the river Meuse the LC/GC and the other, more laborious method showed good agreement.  相似文献   

9.
Gestrinone was studied by high performance liquid chromatography (HPLC) for screening and by gas chromatography/mass spectrometry (GC/MS) for confirmation. When the chromatograms of blank, spiked urine and dosed urine were compared by HPLC, two unknown metabolites were found and these were excreted as the conjugated forms. Metabolites 1 and 2 were tested by LC/MS and LC/MS/MS and both had parent ions at m/z 325. The fragment ion of metabolite 1 was at m/z 263 and ions for metabolite 2 were m/z 307 [MH - H(2)O](+), 289, 279 and 241. LC/MS/MS of m/z 263 as the parent ion of metabolite 1 gave fragment ions at m/z 245 and 217, which were assumed to be [263 - H(2)O](+) and [235 - H(2)O](+), respectively. The trimethylsilyl (TMS)-enol-TMS ether derivative of gestrinone displayed three peaks in its GC/MS chromatogram, formed by tautomerism.  相似文献   

10.
Summary Equilibrium headspace gas chromatography has been applied to the determination of the partition coefficients of volatile compounds in water-air systems. Only techniques that are suited to a fully automatic headspace procedure using the pneumatic headspace sampling-technique have been considered. Particularly simple is the technique of vapor phase calibration —VPC where an external vapor standard is used to calibrate the concentration of the volatile analyte in the headspace, while the concentration in the sample is found from the difference in the total amount in the vial. This technique is described in detail for 2-butanone in water. Finally, the water-air partition coefficients of several selected volatile compounds at different temperatures are listed together with their temperature functions.Dedicated to Professor Leslie S. Ettre on the occasion of his 70th birthday.  相似文献   

11.
The photostability of guaiazulene (1,4-dimethyl-7-isopropylazulene; GA), a natural azulenic compound used in cosmetic and health-care products, as well as in pharmaceutical preparations, was investigated in solution (methanol, ethanol, acetonitrile), by different techniques: gas chromatography/mass spectrometry (GC/MS) and high-performance liquid chromatography combined with atmospheric pressure chemical ionization mass spectrometry and UV detection (LC/APCI-MS and HPLC/UV). A solar simulator (xenon-arc lamp) was used as UV-A radiation source. The study involved: monitoring compound decomposition, identifying products of photodegradation (PPs), assessing the role of oxygen and evaluating the kinetics of the process. Minor PPs are volatile compounds and were characterized by GC/MS, while oligomeric polyoxygenated compounds, tentatively characterized on the basis of MS and MS/MS spectra, were found to be the main photoproducts. The photodegradation was found to be enhanced by the presence of oxygen; nevertheless, determination of the singlet oxygen quantum yield for GA gave a lower value than that for the reference standard Rose Bengal. The obtained results and the developed stability-indicating methods (GC/MS and LC/MS) are of interest for stability studies and/or quality control purposes of GA as raw material or cosmetic products.  相似文献   

12.
Triacylglycerols (TGs) from a sample of summer butterfat (bovine milk) were analysed and fractionated by reversed-phase liquid chromatography (RPLC). Fatty acid and TG composition of eac of the 47 RPLC fractions ranging from 0.1 to 6.9% were determined by capillary gas chromatography. The data were used together to determine the quantitative composition of the molecular species of TGs. A large number of TG species, accounting for 80% of the total, could be unequivocally identified and individually determined. The combination of the chromatographic methods used proved to be a powerful and accurate approach for the determination of molecular species of TGs in a complex fat, but also a difficult and time-consuming task.  相似文献   

13.
14.
15.
Ten different composites used in dentistry for cavity filling, cementation and sealing were analyzed by gas chromatography/ mass spectrometry and liquid chromatography/mass spectrometry using a particle beam interface and direct ionisation mass spectrometry. In this way monomers and various additives as well as contaminants from manufacturing processes could be identified, including compounds which should be avoided from a toxicological point of view.  相似文献   

16.
17.
18.
Inverse gas chromatography (IGC) is a very fast, accurate, and reliable technique to measure diffusion coefficients. This technique however, has been limited to measurements in the infinite dilution region, i.e., in the region of negligible amount of solvent in the polymer. We have extended the scope of inverse gas chromatography to measure diffusion coefficients at finite concentrations of the solvent. This involves doping the carrier gas with a solvent of interest to achieve finite concentrations of solvent in the carrier gas and hence in the polymer. The carrier gas is passed through a saturator maintained at constant temperature to achieve this purpose. Diffusion coefficients for polyvinyl acetate–toluene, and polystyrene–toluene systems were determined at finite concentrations. The results were compared with the traditional gravimetric sorption and piezoelectric sorption measurements reported in the literature. The data are in excellent agreement with the values reported, correlate well with the Vrentas–Duda free volume theory, and can also be predicted from infinitely dilute data using the free volume theory. © 1997 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 35 : 1279–1290, 1997  相似文献   

19.
trans Isomers of naturally occurring cis-unsaturated fatty acids are produced when liquid vegetable oils or marine oils are partially hydrogenated to produce margarine, shortenings, and other hardened-fat products. Isomeric trans fatty acids are also formed in the intestinal tract of ruminants, and they appear in small amounts in dairy products and ruminant meat. Currently, satisfactory analyses for the fatty acid profiles of fats containing trans fatty acids are obtained by gas chromatography (GC) using capillary columns coated with highly polar cyanosilicone stationary phases. In capillary GC methods, the key limitation has been the incomplete separation of trans-monoenoic acid isomers from their cis isomers; however, recent reports have demonstrated that improvements in separation are attainable with the use of 100 m columns. In these columns, there is very little overlap of cis and trans isomers. More accurate trans fatty acid analyses can be obtained by coupling GC with either silver-nitrate thin-layer chromatography or silver-nitrate liquid chromatography.  相似文献   

20.
The constituents in synthetic alkylbenzene samples were analyzed by a comprehensive capillary liquid chromatography (micro-LC) x capillary gas chromatography (CGC). The micro-LC separates the mixture into aliphatic compounds, monosubstituted alkylbenzenes, multisubstituted alkylbenzenes and binuclear aromatic compounds. Each fraction from a single micro-LC injection is stored in turn in a multiloop interface, and then transferred online into CGC sequentially with large volume in-column splitless injection technique for detailed analysis. No sample discrimination was found with this coupling and injection technique. Both the micro-LC column dimension and transfer speed of fraction from interface to CGC were optimized. Quantitative results and the carbon number distribution of each chemical class are obtained by using the comprehensive micro-LC x CGC with flame ionization detection. The reproducibility of peak area is better than 2% RSD.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号