首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper describes a multivariate approach to study the effect on chromatographic conditions and to optimize such conditions in capillary liquid chromatography when high injection volumes are required. Several separations have been evaluated by using isocratic and gradient solvent elution, as well as isocratic elution combined with temperature programming. In this study, easily ionisable organic compounds with low logP have been used as representative analytes. Injection volume and nature of the injection solution have been evaluated in order to increase the sensitivity (peak area) and column performance (N values). The equations obtained by multiple linear regressions and response surfaces allow achieving the optimum on-column focusing conditions for chlorophenoxy acids, carbamates and heterocyclic amines.  相似文献   

2.
Maximization of peak capacity is a very important step in developing one-dimensional separations of complex samples. In recent work, it was shown that the use of small particles in combination with the new technique of ultrahigh pressure liquid chromatography (UHPLC) was able to generate very high peak capacities. Here we show the ability of conventional HPLC instrumentation to give comparable peak capacities to those obtained in UHPLC for the important case of complex mixtures of peptides but at much lower pressures by using a 60 cm long set of columns packed with 5 microm pellicular (superficially porous) particles. We first show, in complete agreement with the well known results of the theory of isocratic separations that, when time is not limiting, the best peak capacities in gradient elution chromatography are obtained by using large particles and the longest column that can be operated at the pump's pressure limit. Two different types of 5 microm particles (superficially porous and totally porous) were compared for their efficiency in gradient chromatography of peptides. We find that the pellicular material gave about 50% higher peak capacity compared to the analogous porous material. A 60 cm column set packed with pellicular particles was made by connecting short columns in series; a peak capacity of about 460 was obtained in 4 h at room temperature. Increasing the column temperature to 70 degrees C reduced the analysis time to 2 h and further increased the peak capacity to more than 500. The number of peaks observed in the separation of bovine serum albumin tryptic peptides was greatly increased and the separation quality was significantly improved.  相似文献   

3.
We report on the optimization of nano‐LC gradient separations of proteomic samples that vary in complexity. The gradient performance limits were visualized by kinetic plots depicting the gradient time needed to achieve a certain peak capacity, while using the maximum system pressure of 80 MPa. The selection of the optimal particle size/column length combination and corresponding gradient steepness was based on scouting the performance of 75 μm id capillary columns packed with 2, 3, and 5 μm fully porous silica C18 particles. At optimal gradient conditions, peak capacities up to 500 can be obtained within a 120 min gradient using 2 μm particle‐packed capillary columns. Separations of proteomic samples including a cytochrome c tryptic digest, a bovine serum albumin tryptic digest, a six protein mix digest, and an Escherichia coli digest are demonstrated while operating at the kinetic‐performance limit, i.e. using 2‐μm packed columns, adjusting the column length and scaling the gradient steepness according to sample complexity. Finally, good run‐to‐run retention time stability (RSD values below 0.18%) was demonstrated applying ultra‐high pressure conditions.  相似文献   

4.
In this study, ultra performance liquid chromatography (UPLC) using pressures up to 1,000 bar and columns packed with sub-2 microm particles has been combined with high temperature mobile phase conditions (up to 90 degrees C). By using high temperature ultra performance liquid chromatography (HT-UPLC), it is possible to drastically decrease the analysis time without loss in efficiency. The stability and chromatographic behavior of sub-2 microm particles were evaluated at high temperature and high pressure. The chromatographic support remained stable after 500 injections (equivalent to 7,500 column volumes) and plate height curves demonstrated the capability of HT-UPLC to obtain fast separations. For example, a separation of nine doping agents was performed in less than 1 min with sub-2 microm particles at 90 degrees C. Furthermore, a shorter column (30 mm length) was used and allowed a separation of eight pharmaceutical compounds in only 40s.  相似文献   

5.
Enantioseparation of limonene‐based bicyclic 1,3‐aminoalcohols and 1,3,5‐ and 1,3,6‐aminodiols was performed by normal‐phase high‐performance liquid chromatographic and supercritical fluid chromatographic (SFC) methods on polysaccharide‐based chiral stationary phases. The effects of the composition of the mobile phase, the column temperature and the structures of the analytes and chiral selectors on retention and selectivity were investigated by normal‐phase LC and SFC technique. Thermodynamic parameters derived from selectivity–temperature‐dependence studies were found to be dependent on the chromatographic method applied, the nature of the chiral selector and the structural details of the analytes. Enantiorecognition in most cases was enthalpically driven but an unusual temperature behavior was also observed: decreased retention times were accompanied by improved separation factors with increasing temperature, i.e. some entropically driven separations were also observed. The elution sequence was determined in all cases. The separation of the stereoisomers was optimized in both chromatographic modalities.  相似文献   

6.
A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite‐5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended.  相似文献   

7.
Monodisperse poly(glycidyl methacrylate-divinylbenzene) microspheres were functionalized with propyl sulfonic acid moieties to obtain beads negatively charged in a wide pH range. They were packed into fused-silica capillary of 50 micro, I.D. in order to separate proteins by capillary electrochromatography (CEC). Baseline separation of four basic proteins as well as three cytochrome c variants with an average column efficiency of 60,000 theoretical plates was obtained under isocratic elution conditions. The high efficiency is attributed to the uniformity of the column packing and the hydrophilic surface coverage of the polymer beads derived from the functionalization process. The effect of pH and salt concentration on protein separations was investigated and the results showed that the CEC separation mechanism is the combination of chromatographic retention and electrophoretic migration. Moreover, the column packed with the strongly acidic poly(glycidyl methacrylate-divinylbenzene) beads was also suitable for protein separations by micro-HPLC with a salt gradient. The comparison between the two kinds of elution modes shows that the column described here exhibited higher peak efficiency with isocratic elution in CEC than with gradient elution in micro-HPLC.  相似文献   

8.
The effect of temperature on separation using reversed-phase monolithic columns has been investigated using a nano-LC pumping system for gradient separation of tryptic peptides with MS detection. A goal of this study was to find optimal conditions for high-speed separations. The chromatographic performance of the columns was evaluated by peak capacity and peak capacity per time unit. Column lengths ranging from 20 to 100 cm and intermediate gradient times from 10 to 30 min were investigated to assess the potential of these columns in a final step separation, e.g. after fractionation or specific sample preparation. Flow rates from 250 to 2000 nL/min and temperatures from 20 to 120°C were investigated. Temperature had a significant effect on fast separations, and a flow rate of 2000 nL/min and a temperature of 80°C gave the highest peak capacity per time unit. These settings produced 70% more protein identifications in a biological sample compared to a conventional packed column. Alternatively, an equal amount of protein identifications was obtained with a 40% reduction in run time compared to the conventional packed column.  相似文献   

9.
Currently, chromatographic analyses are carried out by operating columns packed with sub-2 μm particles under very high pressure gradients, up to 1200 bar for 5 cm long columns. This provides the high flow rates that are necessary for the achievement of high column efficiencies and short analysis times. However, operating columns at high flow rates under such high pressure gradients generate a large amount of heat due to the viscous friction of the mobile phase stream that percolates through a low permeability bed. The evacuation of this heat causes the formation of significant or even large axial and radial gradients of all the physico-chemical parameters characterizing the packing material and the mobile phase, eventually resulting in a loss of column efficiency. We previously developed and successfully applied a model combining the heat and the mass balances of a chromatographic column operated under very high pressure gradients (VHPLC). The use of this model requires accurate estimates of the dispersion coefficients at each applied mobile phase velocity. This work reports on a modification of the mass balance model such that only one measurement is now necessary to accurately predict elution peak profiles in a wide range of mobile phase velocities. The conditions under which the simple equilibrium-dispersive (ED) and transport-dispersive (TD) models are applicable in VHPLC are also discussed. This work proves that the new combination of the heat transfer and the ED model discussed in this work enables the calculation of accurate profiles for peaks eluted under extreme conditions, like when the column is thermostated in a water bath.  相似文献   

10.
Nowadays, there are new technologies in high-performance liquid chromatography columns available enabling faster and more efficient separations. In this work, we compared three different types of columns for the analysis of main soy isoflavones. The evaluated columns were a conventional reverse phase particle column, a fused-core particle column, and a monolithic column. The comparison was in terms of chromatographic parameters such as resolution, asymmetry, number of theoretical plates, variability of retention time, and peak width. The lower column pressure was provided by the monolithic column, although lower chromatographic performance was achieved. Conventional and fused-core particle columns presented similar pressure. Results also indicate that direct transfer between particle and monolithic columns is not possible requiring adjustment of conditions and a different method optimization strategy. The best chromatographic performance and separation speed were observed for the fused-core particle column. Also, the effect of sample solvent on the separation and peak shape was evaluated and indicated that monolithic column is the most affected especially when using higher concentrations of acetonitrile or ethanol. Sample solvent that showed the lowest effect on the chromatographic performance of the columns was methanol. Overall evaluation of methanol and acetonitrile as mobile phase for the separation of isoflavones indicated higher chromatographic performance of acetonitrile, although methanol may be an attractive alternative. Using acetonitrile as mobile phase resulted in faster, higher resolution, narrower, and more symmetric peaks than methanol with all columns. It also generated the lower column pressure and flatter pressure profile due to mobile phase changes, and therefore, it presents a higher potential to be explored for the development of faster separation methods.  相似文献   

11.
Temperature was investigated as active parameter in the liquid chromatography (LC) analysis of octylphenol ethoxylates. Significant differences in selectivity were observed when the oligomers were analyzed by reversed phase LC (RPLC) on silica-, zirconia- and polystyrene/divinylbenzene based stationary phases at low (ambient), medium and elevated temperature with acetonitrile/water as mobile phase. As ascertained by LC-mass spectroscopy (MS), in most cases the elution order of the oligomers was completely reversed comparing ambient and high temperature separations. On a graphitized carbon type column, the selectivity remained unchanged, regardless the analysis temperature. Also in normal phase LC, the elution order remained unaffected by temperature variations both for acetonitrile/water and methanol/water mixtures as mobile phase. Surprisingly, when reversed phase LC on a octadecylsilicagel column at different temperatures was repeated with methanol instead of acetonitrile as mobile phase ingredient, the reversal of elution order did not take place. Results are evaluated in terms of thermodynamic parameters.  相似文献   

12.
Fast liquid chromatographic (LC) methods are important for a variety of applications. Reducing the particle diameter (d(p)) is the most effective way to achieve fast separations while preserving high efficiency. Since the pressure drop along a packed column is inversely proportional to the square of the particle size, when columns packed with small particles (<2 microm) are used, ultrahigh pressures (>689 bar) must be applied to overcome the resistance to mobile phase flow. Elevating the column temperature can significantly reduce the mobile phase viscosity, allowing operation at higher flow rate for the same pressure. It also leads to a decrease in retention factor. The advantage of using elevated temperatures in LC is the ability to significantly shorten separation time with minimal loss in column efficiency. Therefore, combining elevated temperature with ultrahigh pressure facilitates fast and efficient separations. In this study, C6-modified 1.0 microm nonporous silica particles were used to demonstrate fast separations using a temperature of 80 degrees C and a pressure of 2413 bar. Selected separations were completed in 30 s with efficiencies as high as 220,000 plates m(-1).  相似文献   

13.
Stoll DR  Li X  Wang X  Carr PW  Porter SE  Rutan SC 《Journal of chromatography. A》2007,1168(1-2):3-43; discussion 2
The absolute need to improve the separating power of liquid chromatography, especially for multi-constituent biological samples, is becoming increasingly evident. In response, over the past few years, there has been a great deal of interest in the development of two-dimensional liquid chromatography (2DLC). Just as 1DLC is preferred to 1DGC based on its compatibility with biological materials we believe that ultimately 2DLC will be preferred to the much more highly developed 2DGC for such samples. The huge advantage of 2D chromatographic techniques over 1D methods is inherent in the tremendous potential increase in peak capacity (resolving power). This is especially true of comprehensive 2D chromatography wherein it is possible, under ideal conditions, to obtain a total peak capacity equal to the product of the peak capacities of the first and second dimension separations. However, the very long timescale (typically several hours to tens of hours) of comprehensive 2DLC is clearly its chief drawback. Recent advances in the use of higher temperatures to speed up isocratic and gradient elution liquid chromatography have been used to decrease the time needed to do the second dimension LC separation of 2DLC to about 20s for a full gradient elution run. Thus, fast, high temperature LC is becoming a very promising technique. Peak capacities of over 2000 and rates of peak capacity production of nearly 1 peak/s have been achieved. In consequence, many real samples showing more than 200 peaks with signal to noise ratios of better than 10:1 have been run in total times of under 30 min. This report is not intended to be a comprehensive review of 2DLC, but is deliberately focused on the issues involved in doing fast 2DLC by means of elevating the column temperature; however, many issues of broader applicability will be discussed.  相似文献   

14.
Two dimensional (2D) liquid chromatography (LC) separations of proteins can be obtained faster and more automated than traditional 2D gel electrophoresis. Previously we have described a 2D LC method for separation of native proteins with separation according to pI by pH-gradient strong anion exchange (SAX) chromatography in the first dimension, and according to hydrophobicity by reversed phase chromatography in the second dimension. Since there are few literature reports on the combination of reduced/alkylated proteins and modern LC, a basic study of the chromatographic properties of a few reduced /alkylated proteins was undertaken with a pH-gradient SAX chromatographic system. Proteins where the disulfide groups were reduced, but not alkylated, were also included. The conditions that separated native proteins according to pI could not be used for neither reduced nor reduced/alkylated proteins. High concentrations of urea (4–8 M) were needed in the mobile phase in order to obtain good peak shapes. Addition of urea had an undesired impact on both the retention of the proteins and the pH gradient profile, with the effect that little correlation between reported pI values and elution pH was found. The conclusion was that proteins should be separated in the native state if good pI–pH correlations are important, and in the alkylated state with urea if other considerations are more important.  相似文献   

15.
16.
Nash MJ  Maskall JE  Hill SJ 《The Analyst》2006,131(6):724-730
Novel HPLC-ICP-MS methodologies are developed using strong anion exchange (Phenomenex SAX-SB) and weak anion exchange (Alltec HAAX) stationary phases in conjunction with a range of aqueous mobile phases to enable simultaneous separations of inorganic Sb(III), Sb(V) and organic trimethylantimony dichloride (TMSb) species in synthetic solutions. Optimum isocratic separations of inorganic Sb(V) and Sb(III) species are achieved using mobile phases comprised of ammonium tartrate under controlled pH conditions, and rapid pH gradient elution profiles are developed to facilitate separations of the Sb(V), Sb(III) and TMSb species in a single chromatographic run. Optimum peak resolution is achieved when using the 100 x 4.6 mm HAAX column at 20 degrees C and 100 mM ammonium tartrate mobile phases with a gradient from pH 3.0 to pH 1.2, although a system peak co-elutes with TMSb under these conditions and precludes quantitative analyses. Interestingly, the elution order of Sb(V), Sb(III) and TMSb species reverses when the temperature of the HAAX stationary phase is increased to 60 degrees C, and concurrent use of a less acidic pH gradient elution profile from pH 2.3 to pH 1.5 is shown to enable successful species separations whilst preventing occurrence of the co-eluting system peak. Limits of detection are achieved in the sub ng mL(-1) range using these novel HPLC-ICP-MS methodologies and provide scope for future environmental analysis applications.  相似文献   

17.
张晶  陈晓东  李丽群  贺建峰  范军  章伟光 《色谱》2016,34(3):321-326
超临界流体色谱(SFC)分离具有速度快、分离效率高、溶剂消耗少等优点,近年来在手性化合物的分离分析中得到诸多应用。本文对比研究了涂覆型多糖手性色谱柱在SFC和高效液相色谱(HPLC)上拆分24种手性化合物的差异。通过比较这些化合物在色谱柱上的保留时间和选择因子等发现多数化合物在SFC上的分离效率要高于其在HPLC上的分离效率,但HPLC对轴手性化合物的分离效率要优于SFC。SFC和HPLC的分离表现出一定的互补性,随着苯环侧链烷基的碳数增加,化合物在SFC上的保留逐渐增强,而在HPLC的保留却逐渐减弱。叶菌唑在使用SFC和HPLC分析时出现了洗脱顺序反转的现象。这些结果为SFC手性拆分提供了参考。  相似文献   

18.
Increasing the column temperature accelerates markedly elution in HPLC. The separation of five free sterols was studied on three packing materials that can withstand high temperatures. These stationary phases included graphitic carbon, a polymeric C18 silica, and a zirconia-based adsorbent. Measurements of retention data were made at up to 150 degrees C with mobile phases of different compositions. Since the columns tested afford different retention mechanisms, a variety of elution patterns were observed, with some being more advantageous than others for certain sterol separations. Effects observed include some selectivity improvements and some elution order reversals. The separation of free sterols in selected fruit juices is also presented. Albeit at the expense of a longer analysis time, the graphitic carbon column produced the best separation of the sterols in this study.  相似文献   

19.
High temperature liquid chromatography (HTLC), with water as the mobile phase, combined with ICP-MS tuned to the detection of Br, for quantification, and a linear ion trap MS, for structural identification, were applied to determine the disposition and metabolic fate of 2-, 3- and 4-bromobenzoic acids (BBAs) following in vitro incubation with rat hepatocytes at 4 mM. The separation of the metabolites was performed using a thermal gradient to increase the eluotropic strength of the aqueous mobile phase through the run to elute less polar components. The use of highly aqueous solvents for separations involving ICP-MS is advantageous because the water does not change the conductivity of the plasma thereby providing a more stable system. The improved system stability resulted in better sensitivity, as shown by the increased signal intensity for HTLC compared to conventional reversed-phase separations. Using HTLC to investigate the in vitro metabolic fate of the BBAs showed the major route of metabolism to be glycine conjugation, irrespective of the structure of the parent, but with different amounts produced depending on the positional isomer. The comparison of HTLC with the conventional methodology showed that chromatography at elevated temperatures had no effect on the observed metabolite profile. HTLC was also applied to urine obtained from an in vivo sample and showed an improved chromatographic peak shape compared to conventional liquid chromatography (LC) whilst providing the same analytical result.  相似文献   

20.
For the separation of complex samples it is necessary to run the analyses on a chromatographic set-up with high peak capacity. The concept of peak capacity is broader than the one of the theoretical plate numbers because it covers both the column characteristics and the run time of the separation. Therefore, a desired peak capacity can be obtained with many combinations of particle diameter, column length, pressure, and analysis time: either with a short column, small-diameter packing, short analysis time, and high pressure; or with less pressure at the expense of a longer column, larger-diameter packing, and longer analysis time. These combinations can be presented in the form of nomograms with the analysis time as x-axis and the peak capacity as y-axis and including particle diameter, column length, and pressure as parameters. The practical limits of the peak capacity are given by the maximum pressure delivered by the pump in use. These considerations are valid for isocratic and gradient separations as well. They are based on a 1982 paper by Halász and G?rlitz and apply the concept of HPLC columns used at their Van Deemter optimum.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号