首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Hollow fiber liquid-phase microextraction and CE were applied for the determination of albendazole sulfoxide (ASOX) enantiomers in liquid culture medium after a fungal biotransformation study. The analytes were extracted from 1 mL of liquid culture medium spiked with the internal standard (rac-hydroxychloroquine) and buffered with 0.50 mol/L phosphate buffer, pH 10. The analytes were extracted into 1-octanol impregnated in the pores of the hollow fiber, and into an acid acceptor solution inside the polypropylene hollow fiber. The electrophoretic separations were carried out in 0.05 mol/L tris(hydroxymethyl)aminomethane buffer, pH 9.3, containing 3.0% w/v sulfated-β-CD (S-β-CD) with a constant voltage of +15 kV and detection at 220 nm. The method was linear over the concentration range of 250-5000 ng/mL for each ASOX enantiomer. Within-day and between-day assay precision and accuracy for the analytes were studied at three concentration levels and the values of RSD% and relative error % were lower than 15%. The developed method was applied for the determination of ASOX after a biotransformation study employing the endophytic fungus Penicillium crustosum (VR4). This study showed that the endophytic fungus was able to metabolize the albendazole to ASOX enantioselectively. In addition, it was demonstrated that hollow fiber liquid-phase microextraction coupled to CE can be an excellent and environmentally friendly technique for the analysis of samples obtained in biotransformation studies.  相似文献   

2.
Liquid-phase microextraction based on polypropylene hollow fibers and CE were applied for the chiral determination of hydroxychloroquine (HCQ) and its metabolites (desethylchloroquine, DCQ; desethylhydroxychloroquine, DHCQ; bisdesethylchloroquine, BDCQ) in human urine. The analytes were extracted from 3 mL of urine spiked with the internal standard (metoprolol) and alkalinized with 250 muL of 2 M NaOH. The analytes were extracted into 1-octanol impregnated in the pores of the hollow fiber, and into an acid acceptor solution inside the hollow fiber. The electrophoretic separations were carried out in 100 mmol/L Tris buffer (pH adjusted to 9.0 with phosphoric acid) containing 1% w/v S-beta-CD and 30 mg/mL HP-beta-CD with a constant voltage of +18 kV. The method was linear over the concentration range of 10-1000 ng/mL for each HCQ stereoisomer and 21-333 ng/mL for each metabolite stereoisomer. Within-day and between-day assay precision and accuracy for the analytes were studied at three concentration levels for each stereoisomer and were lower than 15%. The developed method was applied for the determination of the cumulative urinary excretion of HCQ, DCQ, and DHCQ after oral administration of rac-HCQ to a health volunteer. The results obtained are in agreement with previous literature data.  相似文献   

3.
The present work describes for the first time the use of SPME coupled to LC–MS/MS employing the polar organic mode in a stereoselective fungal biotransformation study to investigate the fungi ability to biotransform the drug risperidone into its chiral and active metabolite 9-hydroxyrisperidone (9-RispOH). The chromatographic separation was performed on a Chiralcel OJ-H column using methanol:ethanol (50:50, v/v) plus 0.2% triethylamine as the mobile phase at a flow rate of 0.8 mL min−1. The SPME process was performed using a C18 fiber, 30 min of extraction time and 5 min of desorption time in the mobile phase. The method was completely validated and all parameters were in agreement with the literature recommendations. The Cunninghamella echinulata fungus was able to biotransform risperidone into the active metabolite, (+)-9-RispOH, resulting in 100% of enantiomeric excess. The Cunninghamella elegans fungus was also able to stereoselectively biotransform risperidone into (+)- and (−)-9-RispOH enantiomers at different rates.  相似文献   

4.
An high performance liquid chromatography (HPLC) method for the enantioselective determination of donepezil (DPZ), 5-O-desmethyl donepezil (5-ODD), and 6-O-desmethyl donepezil (6-ODD) in Czapek culture medium to be applied to biotransformation studies with fungi is described for the first time. The HPLC analysis was carried out using a Chiralpak AD-H column with hexane/ethanol/methanol (75:20:5, v/v/v) plus 0.3 % triethylamine as mobile phase and UV detection at 270 nm. Sample preparation was carried out by liquid-liquid extraction using ethyl acetate as extractor solvent. The method was linear over the concentration range of 100-10,000 ng mL(-1) for each enantiomer of DPZ (r ≥ 0.9985) and of 100-5,000 ng mL(-1) for each enantiomer of 5-ODD (r ≥ 0.9977) and 6-ODD (r ≥ 0.9951). Within-day and between-day precision and accuracy evaluated by relative standard deviations and relative errors, respectively, were lower than 15 % for all analytes. The validated method was used to assess DPZ biotransformation by the fungi Beauveria bassiana American Type Culture Collection (ATCC) 7159 and Cunninghamella elegans ATCC 10028B. Using the fungus B. bassiana ATCC 7159, a predominant formation of (R)-5-ODD was observed while for the fungus C. elegans ATCC 10028B, DPZ was biotransformed to (R)-6-ODD with an enantiomeric excess of 100 %.  相似文献   

5.
An enantioselective assay for the determination of methadone and its main metabolite 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine in equine plasma based on capillary electrophoresis with highly sulfated γ‐cyclodextrin as chiral selector and electrokinetic analyte injection is described. The assay is based on liquid/liquid extraction of the analytes at alkaline pH from 0.1 mL plasma followed by electrokinetic sample injection of the analytes from the extract across a buffer plug without chiral selector. Separation occurs cationically at normal polarity in a pH 3 phosphate buffer containing 0.16% (w/v) of highly sulfated γ‐cyclodextrin. The developed assay is precise (intra‐ and interday RSD < 4% and < 7%, respectively), is capable to determine enantiomer levels of methadone and 2‐ethylidene‐1,5‐dimethyl‐3,3‐diphenylpyrrolidine in plasma down to 2.5 ng/mL, and was successfully applied to monitor enantiomer drug and metabolite levels in plasma of a pony that was anesthetized with racemic ketamine and isoflurane and received a bolus of racemic methadone and a bolus followed by constant rate infusion of racemic methadone. The data suggest that the assay is well suited for pharmacokinetic purposes.  相似文献   

6.
A simple hollow fiber liquid‐phase microextraction method for the determination of synthetic pyrethroid metabolites, 3‐phenoxybenzoic acid and 4‐hydroxy‐3‐phenoxybenzoic acid, in human and rat urine was developed and validated. A polypropylene hollow fiber tightly fitted onto a Nylon rod and impregnated with organic solvent served as a disposable extraction device. Desorption of analytes was carried out in NaOH solution, analyzed further by gradient HPLC and diode array detection method. Important factors were identified using Taguchi OA16 (45) orthogonal array design and further optimized using univariate approach. The optimum method performance was observed when 1 mL of urine hydrolyzed with 0.2 mL of concentrated HCl was further supplemented with 100 mg of NaCl and extracted for 120 min into dihexyl ether immobilized in the pores of the hollow fiber. Metabolites were desorbed into 0.1 mL of 0.1 M NaOH for another 120 min. Limits of detection and quantitation of 15 and 50 ng/mL were obtained for both analytes. Relative standard deviations of 1.6–12.6% over the linear range (50–10,000 ng/mL, r > 0.9906) were observed. Intra‐ and inter‐day accuracies of the method ranged from 98.3 to 109.5% and from 93.3 to 110.9%, respectively. The optimized method was applied to the analysis of real urine samples collected from rats exposed orally to cypermethrin. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
Capillary electrophoresis and liquid-phase microextraction using porous polypropylene hollow fibers were employed for the enantioselective analyses of mirtazapine and its metabolites demethylmirtazapine and 8-hydroxymirtazapine in human urine. Before the extraction, urine samples (1.0 mL) were submitted to enzymatic hydrolysis at 37 degrees C for 16 h. Then, the enzyme was precipitated with trichloroacetic acid, the pH was adjusted to 8 with 0.5 mol/L phosphate buffer solution (pH 11) and 15% sodium chloride was further added. The analytes were transferred from the aqueous donor phase, through n-hexyl ether (organic solvent immobilized in the fiber), into 0.01 moL/L acetic acid solution (acceptor phase). The electrophoretic analyses were carried out in 50 mmol/L phosphate buffer solution (pH 2.5) containing 0.55% w/v carboxymethyl-beta-cyclodextrin. The method was linear over the concentration range of 62.5-2500 ng/mL for each mirtazapine and 8-hydroxymirtazapine enantiomer and 62.5-1250 ng/mL for each demethylmirtazapine enantiomer. The quantification limit was 62.5 ng/mL for all the enantiomers. Within-day and between-day assay precision and accuracy were lower than 15% for all the enantiomers. Finally, the method proved to be suitable for pharmacokinetic studies.  相似文献   

8.
An ionic liquid mediated sol-gel sorbents for hollow fiber solid-phase microextraction (HF-SPME) was developed for extraction of the pesticides: diazinon, fenitrothion, malathion, fenvalerate, phosalone and tridemorph from human hair and water samples. The analytes were subsequently analyzed with high performance liquid chromatography and diode array detection (HPLC-DAD). Preliminary experiments were carried out in order to study experimental conditions for pesticides' extraction from spiked hair and water samples with HF-SPME using hollow fiber-supported ionic liquid mediated sol-gel sorbent. The sol-gel nanocomposites were reinforced with nanoparticles such as carboxylic functionalized multi-walled carbon nanotubes (COOH-MWCNTs), amino functionalized multi-walled carbon nanotubes (NH(2)-MWCNTs), nano SiO(2), nano TiO(2) and nano MgO comparatively to promote extraction efficiency. In this device, the innovative solid sorbents were developed by the sol-gel method via the reaction of tetraethylorthosilicate (TEOS) with 2-amino-2-hydroxymethyl-propane-1,3-diol (TRIS). In the basic condition (pH 10-11), the gel growth process in the presence of ionic liquid and nanoparticles was initiated. Then, the sol was injected into a polypropylene hollow fiber segment for in situ gelation process. Parameters affecting the efficiency of HF-SPME were thoroughly investigated. Linearity was observed over a range of 0.01-25,000 ng/mL with detection limits between 0.004 and 0.095 ng/mL for the pesticides in the aqueous matrices and 0.003-0.080 ng/mL in the hair matrices. The relative recoveries in the real samples ranged from 82.0% to 94.0% for the pesticides store seller's hair and the work researchers' hair. Results are showing the great possibilities of HF-SPME-HPLC-PDA for analysis of pesticides in biological and environmental samples.  相似文献   

9.
A three-phase hollow-fiber liquid-phase microextraction (HF-LPME) method for the stereoselective determination of bufuralol metabolites 1'-oxobufuralol (1'-Oxo-BF) and 1'-hydroxybufuralol (1'-OH-BF) in microsomal preparations is described for the first time. The HPLC analysis was carried out using a Chiralcel OD-H column with hexane/2-propanol/methanol (97.5:2.0:0.5, v/v/v) plus 0.5% diethylamine as the mobile phase, and UV detection at 248 and 273 nm. The HF-LPME optimized conditions involved: n-octanol as the organic solvent, 0.2 mol/L acetic acid as the acceptor phase, donor phase pH adjusted to 13, sample agitation at 1500 rpm and extraction for 30 min. By using this extraction procedure, the recovery rates were in the range of 63-69%. The method was linear over the concentration range of 100-5000 ng/mL for each enantiomer of 1'-Oxo-BF (r>0.9978) and of 100-2500 ng/mL for each stereoisomer of 1'-OH-BF (r>0.9957). The quantification limits were 100 ng/mL for all analytes. The validated method was used to assess the in vitro biotransformation of bufuralol using rat liver microsomal fraction that demonstrated predominant formation of (S)-1'-Oxo-BF and (R,R)-1'-OH-BF.  相似文献   

10.
This study used the general applicability of 2,6-didi-o-methyl-β-cyclodextrin (DM-β-CD) as the chiral selector in capillary electrophoresis for fast and efficient chiral separation of repaglinide enantiomers. A systematic study of the parameters affecting separation was performed with UV detection at 243 nm. The optimum conditions were determined to be 1.25% (w/v) DM-β-CD in 20 mM sodium phosphate (pH 2.5) as the running buffer and separation voltage at 20 kV. DM-β-CD had the best enantiomer resolution properties under the tested conditions, whereas other β-cyclodextrins showed inferior performances or no performance. The proposed method had a linear calibration curve in the concentration range of 12.5-400 μg/mL. The limit of detection was 100 ng/mL. The intra-day and inter-day precisions were 2.8 and 3.2%, respectively. Recoveries of 97.9-100.9% were obtained. The proposed method was fast and convenient, and was determined to be efficient for separating enantiomers and applicable for analyzing repaglinide enantiomers in quality control of pharmaceutical production.  相似文献   

11.
For the first time, a fast, high-performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of the new ultra-short hypnotic HIE-124 and its metabolite in mice serum. Each compound, together with carbamazepine (internal standard) was extracted from the serum matrix using liquid-liquid extraction (LLE). Chromatographic resolution of the analytes was performed on a Chromolith Speed Rod monolithic silica column (100 mm × 4.6 mm i.d.) under isocratic conditions using a mobile phase of 65:35 (v/v), 20 mM phosphate buffer (pH 7.0 adjusted with phosphoric acid)-acetonitrile. The elution of the analytes were monitored at 240 nm and conducted at ambient temperature. Because of high column efficiency the mobile phase was pumped at a flow rate of 2.5 mL min(-1). The total run time of the assay was 2 min. The method was validated over the range of 60-2000 ng mL(-1) for HIE-124 and 200-1600 ng mL(-1) for the metabolite (r(2) = 0.99). The limit of detection (LOD) for HIE-124 and its metabolite were 20 ng mL(-1) and 65 ng mL(-1), respectively. The proposed method was validated in compliance with ICH guidelines, in terms of accuracy, precision, limits of detection and quantitation and other aspects of analytical validation. The developed method could be used for the trace analyses of HIE-124 and its metabolite in serum and was finally used for the pharmacokinetic study investigation of HIE-124 in mice serum.  相似文献   

12.
A sensitive, rapid and specific method for the simultaneous quantification of oxysophocarpine (OSC) and its active metabolite sophocarpine (SC) in rat plasma was developed and validated, using a liquid-liquid extraction procedure followed by liquid chromatography/electrospray ionization mass spectrometric (LC/ESI-MS) analysis. The separation was performed on a Zorbax Extend-C(18) column (2.1 mm i.d. x 50 mm, 5 microm) with a C(18) guard column using methanol-water containing 5 mm ammonium acetate (15:85, v/v) as mobile phase. Analysis was performed in selected ion monitoring (SIM) mode with an electrospray ionization (ESI) interface. [M + H](+) at m/z 263 for OSC, [M + H](+) at m/z 247 for SC and [M + H](+) at m/z 249 for matrine (internal standard) were selected as detecting ions, respectively. The method was linear in the concentration ranges 10-1000 ng/mL for OSC and 5-500 ng/mL for SC. The intra- and inter-day precisions (coefficient of variation) were within 7% for both analytes. Their accuracy (relative error) ranged from -6.4 to 1.5%. The limits of detection for OSC and SC were 3 and 1.5 ng/mL, respectively. The limits of quantitation for OSC and SC were 10 and 5 ng/mL, respectively. Recoveries of both analytes were greater than 85% at the low, medium and high concentrations. Both analytes were stable during all sample storage, preparation and analytic procedures. The method was successfully applied to a pharmacokinetic study after an oral administration of OSC to rats with a dose of 15 mg/kg.  相似文献   

13.
Tsai TF  Lee MR 《Talanta》2008,75(3):658-665
Trace amounts of diuretics were determined in human urine by hollow fiber liquid-phase microextraction (LPME) combined with liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) in this study. Chromatography was performed on a C(8) reversed-phase column. A 25 microL n-octanol was used to extract analytes in urine. Extraction was optimized using a pH 2 solution spiked with 0.15 g/mL NaCl for 40 min at 40 degrees C with 1010 rpm stirring. The limits of detection of diuretics in urine were 0.3-6.8 ng/mL, and linearity range was 1-1000 ng/mL. Recoveries of spiked 50 ng/mL diuretics were 97.7-102.5%. The intra-day precision and inter-day precision were 3-18% and 4-21%, respectively. The diuretics concentration profiles in patient urine were also determined. The results of this study reveal the adequacy of LPME-LC-MS/MS method for analyzing diuretics in urine and quantification limits exceed World Anti-Doping Agency requirements.  相似文献   

14.
This paper presents two procedures for the determination of four selective serotonin reuptake inhibitors (citalopram, paroxetine, fluoxetine, and sertraline) and one metabolite (norfluoxetine) in sewage sludge utilizing three-phase hollow fiber liquid-phase microextraction (HF-LPME). First, direct HF-LPME was used for extraction, clean-up, and preconcentration. The pharmaceuticals were extracted from slurry samples into an organic phase and then back-extracted into an aqueous phase in the lumen of the hollow fiber. Second, a procedure combining pressurized hot water extraction and HF-LPME for clean-up and preconcentration was developed for the same analytes and matrix. The extracts were subsequently analyzed by liquid chromatography-mass spectrometry. For direct HF-LPME, limits of detection were between 1 and 12 ng g(-1) (dry weight) and the relative standard deviation (RSD) values were 3-12%. For the second method, limits of detection were approximately 6 ng g(-1) for all the compounds and RSD values were 8-12%. The methods were validated by comparison of results for the same samples. Sewage sludge from a Swedish wastewater treatment plant was analyzed by both methods; average concentrations were similar for citalopram, paroxetine, and fluoxetine with values of approximately 530, 40, and 200 ng g(-1) , respectively.  相似文献   

15.
A selective method using three-phase liquid-phase microextraction (LPME) in conjunction with LC-MS-MS was devised for the enantioselective determination of chloroquine and its n-dealkylated metabolites in plasma samples. After alkalinization of the samples, the analytes were extracted into n-octanol immobilized in the pores of a polypropylene hollow fiber membrane and back extracted into the acidic acceptor phase (0.1 M TFA) filled into the lumen of the hollow fiber. Following LPME, the analytes were resolved on a Chirobiotic V column using methanol/ACN/glacial acetic acid/diethylamine (90:10:0.5:0.5 by volume) as the mobile phase. The MS detection was carried out using multiple reaction monitoring with ESI in the positive ion mode. The optimized LPME method yielded extraction recoveries ranging from 28 to 66%. The method was linear over 5-500 ng/mL and precision (RSD) and accuracy (relative error) values were below 15% for all analytes. The developed method was applied to the determination of the analytes in rat plasma samples after oral administration of the racemic drug.  相似文献   

16.
A simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated for simultaneous quantification of olanzapine, clozapine, ziprasidone, haloperidol, risperidone, and its active metabolite 9-hydroxyrisperidone, in rat plasma using midazolam as internal standard (IS). The analytes were extracted from rat plasma using a single step liquid-liquid extraction technique. The compounds were separated on a Waters Atlantis dC-18 (30 mm x 2.1 mm i.d., 3 microm) column using a mobile phase of acetonitrile/5 mM ammonium formate (pH 6.1 adjusted with formic acid) with gradient elution. All of the analytes were detected in positive ion mode using multiple reaction monitoring (MRM). The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. LLOQ was 0.1 ng/mL and correlation coefficient (R(2)) values for the linear range of 0.1-100 ng/mL were 0.997 or greater for all the analytes. The intra-day and inter-day precision and accuracy were better than 8.05%. The relative and absolute recovery was above 77% and matrix effects were low for all the analytes except for ziprasidone. This validated method has been successfully used to quantify the plasma concentration of the analytes after chronic treatment with antipsychotic drugs.  相似文献   

17.
A new, rapid analytical method, based on liquid chromatography with diode array detection, has been developed and applied to the determination of risperidone and its main active metabolite 9-hydroxyrisperidone in human plasma. The chromatographic separation was obtained on a C8 (150 x 4.6 mm, 5 microm) column, using a mobile phase composed of acetonitrile (27%) and a pH 3.0 phosphate buffer (73%). A sample clean-up procedure was carried out by using C8 cartridges and eluting the analytes with methanol. The extraction yield was highly satisfactory for both analytes, with average absolute recovery values of about 95%. The experimental conditions permitted the quantitative determination of risperidone and 9-hydroxyrisperidone with high precision (RSD < 3.6%) and satisfactory sensitivity (LOQ = 4 ng mL(-1)). The method was applied to plasma samples from a patient who had tried to poison himself with 150 mg of risperidone, and was undergoing polypharmacy.  相似文献   

18.
A simple and efficient method based on hollow fiber protected headspace liquid-phase in conjunction with high performance liquid chromatography has been introduced for extraction and determination of three residual monomers (2-ethylhexyl acrylate (EHA), vinyl acetate (VA), glycidyl methacrylate (GM)) in polymer latex. Using this methodology, the analytes of interest extracted from a sample are led into organic solvent located inside the porous hollow fiber membrane. Initially, several experimental parameters were controlled and optimized and the optimum conditions were reached with 8 cm neatly cut hollow fibers containing heptanol, which were exposed to the headspace of a 12 mL sample solution containing 20% (w/v) NaCl thermostated at 110 °C and stirred at 800 rpm for 20 min. Finally, 20 μL of the extraction solution was withdrawn into a syringe and injected into HPLC for analysis. The calibration curves were linear (r2 ≥ 0.994) over the concentration range of 0.05-10 mg L−1 for VA and 0.02-10 mg L−1 for other analytes. The relative standard deviation (RSD%) for three-replicate extractions and measurements was below 8.6%. The limits of detection of this method for quantitative determination of the analytes were found within the range of 0.005 to 0.011 mg kg−1 with the enrichment factors within the 5-164 range. The method was successfully applied for determination of residual monomers in polymer latex.  相似文献   

19.
A static and exhaustive extraction mode of hollow fiber-supported liquid membrane was developed for field sample passive pretreatment of environmental water samples. The extraction device was prepared by immobilizing dihexyl ether in the wall of a polypropylene hollow fiber membrane (60 cm length, 50 μm wall thickness, and 280 μm id) as liquid membrane and filling the fiber lumen with 0.1 M NaOH as acceptor, and closing the two ends of the fiber with an aluminum foil. Passive extraction was conducted by immersing the device into 15 mL water samples modified with 0.01 M HCl and 20% m/v NaCl. Model analytes including 4-chlorophenol, 2,4-dichlorophenol, and 2,4,6-trichlorophenol were transferred into acceptor with extraction efficiencies over 79% in 10 h at room temperature, and determined by high-performance liquid chromatography. The proposed method has the enrichment factor of 394-498 and LOD of 0.3-0.4 μg/L for the three chlorophenols. Humic acid and salinity in the environmentally relevant range had no significant influence on the extraction, and chlorophenols in various environmental waters were determined with spike recoveries between 71.6 and 120%. The static passive extraction nature benefited field sample pretreatment without power, whereas the exhaustive extraction mode effectively eliminated the sample matrix effects.  相似文献   

20.
Li P  Duan J  Hu B 《Electrophoresis》2008,29(14):3081-3089
A hollow fiber-based liquid-liquid-liquid microextraction (HF-LLLME) combined with on-line large-volume sample stacking (LVSS) has been developed for the speciation of organomercury in biological samples by CE with UV detection. Separation was achieved in less than 11 min with an electrolyte consisting of 35 mM sodium tetraborate at pH 9.1. In LVSS, a reverse electrode polarity-stacking mode (REPSM) was applied as on-line preconcentration strategy. In HF-LLLME, the analytes were extracted from 12 mL volume of sample solution (pH adjusted to 3.0) into bromobenzene impregnated in the pores of the hollow fiber, and into an acceptor solution of L-cysteine (15 microL, 0.02% w/v) inside the hollow fiber. Under the optimized conditions, concentration factors of 2610-4580 were achieved and LODs in the range of 0.03-0.14 microg/L were feasible. The linearity was found to be over two orders of magnitude with correlation coefficient of 0.9991-0.9996. The developed method has been validated using a certified reference material (DORM-2, dogfish muscle), and the determined values coincided very well with the certified values. The method was also applied to the speciation of organomercury in three kinds of fish samples and human hair samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号