首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A reversed-phase liquid chromatography coupled to tandem mass spectrometry (LC?CMS?CMS) method was developed and validated for the determination of fulvestrant in rat plasma. Sample preparation involved a liquid-liquid extraction using 1.0 mL of n-hexane?Cisopropanol (90:10, v/v) to extract the analyte from 0.1 mL of rat plasma. The analytes were separated on a phenyl-based column using the mobile phase consisting of methanol/water containing 5 mM ammonium acetate at the flow rate of 0.3 mL min?1. The analytes were monitored by tandem mass spectrometry under electrospray negative ionization mode. Linear calibration curves were generated over the fulvestrant concentration ranges of 0.05?C10.0 ng mL?1 in rat plasma. The accuracy and within- and between-day precisions were within the generally accepted criteria for bioanalytical methods (<15%). This developed and validated assay method was successfully employed to characterize the plasma concentration-time profile of fulvestrant after its intramuscular administration in rats at a dose of 10 mg kg?1.  相似文献   

3.
A sensitive and specific liquid chromatography?Celectrospray ionization?Ctandem mass spectrometry method has been developed and validated for the identification and quantification of brivudine in human plasma using diclofenac as an internal standard. The method involves extraction with ethyl acetate. The analyte was separated on a C18 column and analyzed in multiple reaction monitoring mode with a negative electrospray ionization interface using the [M?CH]? ions, m/z 332.8??m/z 80.9 for brivudine, m/z 293.6??m/z 249.5 for diclofenac. The method was validated over the concentration range of 5.54?C2,836 ??g L?1 for brivudine. The intra-and inter-day precisions were less than 8.91% in terms of relative standard deviation (RSD), and the accuracy was within ?4.22% in terms of relative error (RE). The lower limit of quantification (LLOQ) was 5.54 ??g L?1 with acceptable precision and accuracy. There were almost no matrix effects. Recovery of brivudine spiked in drug-free plasma was higher than 77.17%. The method was used to study the pharmacokinetic profile of brivudine in human plasma after oral administration of brivudine tablets.  相似文献   

4.
5.
A fast, sensitive, and specific LC?CMS?CMS method for determination of quinine (QN) and doxycycline (DOX) in rat plasma has been developed and validated. QN, DOX, and cimetidine (internal standard, IS) were extracted from the plasma by protein precipitation. The compounds were separated on a C18 column with methanol?C0.1% aqueous formic acid 70:30 (v/v) as mobile phase at a flow rate of 0.5 mL min?1 (split 1:3). Detection was by positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode, monitoring the transitions 325.0 ?? 307.0, 445.0 ?? 428.1, and 252.8 ?? 159.0, for QN, DOX, and IS, respectively. The analysis was carried out in 2.0 min and the method was linear in the plasma concentration range 5?C5,000 ng mL?1. The mean extraction recoveries for QN, DOX, and IS from plasma were 89.4, 90.5, and 86.3%, respectively. The method was validated for linearity, precision, accuracy, specificity, and stability; the results obtained were within the acceptable range. The proposed method was successfully applied to the determination of QN and DOX in rat plasma samples to support pharmacokinetic studies.  相似文献   

6.
A rapid and sensitive LC?CMS?CMS method was developed for the quantification of amphotericin B in rabbit tears using natamycin as internal standard. The analyte and internal standard were extracted from the tear sample using a solid phase extraction method. Chromatographic separation was achieved on a Phenomenex Luna 3 ??m CN column (100 × 2 mm, 3 ??m) using 3.5 mM ammonium acetate (pH 4):methanol (10:90) as mobile phase. The assay was validated with a linear range of 0.1?C3.2 ??g mL?1 for amphotericin B using 10 ??L of tear sample. The intra- and inter-day assay precision ranged from 2.49 to 4.37 and 2.17 to 5.59%, respectively, and intra- and inter-day assay accuracy was between from 0.27 to 3.32 and ?0.51 to 3.72%, respectively. The method was successfully applied to the pharmacokinetic studies of amphotericin B eye drops in rabbit tears.  相似文献   

7.
A rapid, sensitive and accurate high performance liquid chromatography method using tandem mass spectrometry detection for hydralazine in BALB/C mouse plasma and brain was developed and validated. The method involved a derivatization with 2,4-pentanedione at 50 °C for 1 h, and a step of solid phase extraction to purify and concentrate hydralazine derivative. Chromatographic separation was carried out on an Agilent ZORBAX SB-C18 column by elution with methanol?C0.01 mol L?1 ammonium acetate (60:40, v/v). The multiple reaction monitoring transition used for quantification was m/z 225.2 ?? 129.5 in the electrospray positive ionization mode. Good linearity was obtained over the concentration range of 10?C200 ng mL?1. The limits of detection were 0.49 and 1.05 ng mL?1 for hydralazine in mouse plasma and brain, respectively. The limits of quantitation were 1.5 and 3.18 ng mL?1 for hydralazine in mouse plasma and brain, respectively. Sample analysis time was 6 min including sample separation. The method was successfully applied to a pharmacokinetic study following intraperitoneal injection of hydralazine in BALB/C mice at the dose of 20 mg kg?1.  相似文献   

8.
A rapid and selective liquid chromatographic/tandem mass spectrometric method for the determination of JBP485 was developed and validated. Following protein precipitation, the analyte and internal standard (JBP923) were separated from human plasma using an isocratic mobile phase on an Elite Kromasil C18 column. An API 3200 tandem mass spectrometer equipped with a Turbo ionSpray ionization source was used as the detector and operated in the positive ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 201.2 ?? 86.2 and m/z 219.2 ?? 86.2 was performed to quantify JBP485 and JBP923, respectively. The method was linear in the concentration range of 0.10?C50.00 ??g mL?1 using 100 ??L of plasma. The lower limit of quantification was 0.10 ??g mL?1. The intra- and inter-day relative standard deviations over the entire concentration range were less than 6.65%. Accuracy determined at three concentrations (0.25, 4.00 and 25.00 ??g mL?1 for JBP485) ranged from ?0.78 to 2.74% in terms of relative error. Each plasma sample was chromatographed within 2.0 min. The method was successfully applied to characterize the pharmacokinetic profiles of JBP485 in rats after an intravenous injection of 6.25 mg kg?1 JBP485.  相似文献   

9.
Xin Hu  Yun-Feng Lv  Kai-Shun Bi 《Chromatographia》2009,69(9-10):1073-1076
A rapid and simple high-performance liquid chromatographic tandem mass spectrometric method has been developed and validated for analysis of strictosamide in rat plasma. Chromatographic separation was achieved on a C18 column by gradient elution with mixtures of methanol, water, and acetonitrile containing 0.05% acetic acid. Digoxin was used as internal standard. Selected reaction monitoring (SRM) was used for MS quantitation. Linearity was good in the range 0.05–20 ng mL?1 in rat plasma. The lower limit of quantitation was 0.04 ng mL?1. The method is precise and reliable and can be applied to pharmacokinetic studies.  相似文献   

10.
A rapid and sensitive liquid chromatographic–tandem mass spectrometric method for analysis of adefovir in human plasma has been developed and validated. After protein precipitation and evaporation, 10 μL supernatant was injected for reversed-phase LC separation. Adefovir and the internal standard (acyclovir) were monitored in selected reaction monitoring (SRM) mode at m/z 274.10 → 256.00 and 226.10 → 152.00, respectively. The calibration plot was linear over the concentration range 0.5–100 ng mL?1, and correlation coefficients were >0.999. Mean intra-day and inter-day accuracy ranged from 89.43 to 93.20% and from 91.40 to 95.57%, respectively, and mean intra-day and inter-day precision was between 2.40 and 7.66% and between 5.60 and 10.47%, respectively. The method was successfully applied to a Phase I pharmacokinetic study of adefovir after oral administration of adefovir dipivoxil capsules at doses of 5, 10, and 20 mg to twenty-four healthy Chinese volunteers.  相似文献   

11.
《Analytical letters》2012,45(7):1365-1379
Abstract

A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC–ESI–MS) method was developed and validated for the identification and quantification of indapamide in human plasma. After the addition of the internal standard (IS) and 0.1 M sodium hydroxide solution, plasma samples were extracted with diethyl ether. The organic layer was evaporated under a stream of nitrogen at 40°C. The residue was reconstituted with 200 µL methanol. The compounds were separated on a stainless‐steel column (C18 Shim‐pack 5 µm 150 mm×2.0 mm I.D., Shimadzu) at a flow rate of 0.2 mL/min by a gradient elution. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via an electrospray ionization (ESI) source. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 0.5–100.0 ng/mL with a coefficient of determination (r) of 0.9998 and good back‐calculated accuracy and precision. The intra‐ and inter‐day precision (RSD%) was lower than 10% and accuracy ranged from 85% to 115%. The lower limit of quantification was identifiable and reproducible at 0.2 ng/mL with 0.2 mL plasma. The proposed method enables the unambiguous identification and quantification of indapamide for pharmacokinetic, bioavailability, or bioequivalence studies.  相似文献   

12.
13.
A specific and accurate high-performance liquid chromatographic method for analysis of cinnamic acid (CA) and paeonol (PN) in rat plasma has been developed and validated. Plasma samples were pretreated by protein precipitation with methanol, and the supernatant was injected for reversed-phase separation on a C18 column with acetonitrile–0.1% phosphoric acid 24:76 (v/v) as mobile phase at a flow-rate of 1.0 mL min?1. Phenylbutyric acid was used as the internal standard. Good linear relationships were obtained between response and concentration in the range 0.130–52.0 μg mL?1 (r = 0.9980) and 0.1785–71.4 μg mL?1 (r = 0.9950) for CA and PN, respectively. Intra-day and inter-day assay precision (RSD, n = 6) at three concentrations was not above 15.1% for either CA and PN, and accuracy was from 94.3 to 104.7% and from 103.3 to 113.1% for CA and PN, respectively. Mean recovery of CA and PN from plasma samples was 87.5 and 86.8%, respectively, and recovery of the internal standard at a concentration of 1.00 mg mL?1 was 88.5%. Results from a stability study suggested CA and PN were stable under the experimental conditions used. Finally, the validated method was successfully applied to a pharmacokinetic study of CA and PN in rats after intragastric administration of Guizhi–Fuling capsule. The results obtained would be very useful for evaluation of the clinical efficacy of GFC.  相似文献   

14.
15.
16.
A facile preparation of the title compound by 1,3-dipolar cycloaddition reaction of benzonitrile oxides with isatin imines or isatin diimines, in excellent yield, are reported.  相似文献   

17.
18.
Nilam C. Dige 《合成通讯》2013,43(21):2498-2510
An efficient, four-component reaction of isatin, 1,3-indanedione, ethyl acetoacetate, and ammonium acetate in ethanol/water (9:1) system furnished spiro[4H-indeno[1,2-b]pyridine-4,3′-[3H]indoles] at room temperature. Merits of the method are mild reaction conditions, simple workup procedure, and ambient temperature. The synthesized compounds exhibit excellent fluorescence properties.  相似文献   

19.
Choi  Young Hee  Suh  Jung Hwa  Lee  Joo Hyun  Cho  Il Hwan  Lee  Chul Kyu  Lee  Myung Gull 《Chromatographia》2009,70(9-10):1435-1439

A simple, rapid, and reproducible reversed-phase LC method with UV detection at 215 nm has been developed for analysis of SP-8203 in rat samples. A C18 column was used with 3,000:1,050 (v/v) 0.01 m K2HPO4 buffer (pH 3)–acetonitrile as mobile phase at a flow rate of 1.7 mL min−1 at 50 °C. Samples were extracted with dichloromethane containing ondansetron (internal standard). Detection limits for SP-8203 in plasma, urine, and gastrointestinal tract samples were 0.05, 0.5, and 10 μg mL−1, respectively. The method was suitable for pharmacokinetic study of SP-8203 in rats after intravenous administration.

  相似文献   

20.
A reliable and sensitive liquid chromatographic–tandem mass spectrometric method, with rutin as internal standard, has been developed and validated for simultaneous determination of danshensu, salvianolic acid B (SAB), and hydroxysafflor yellow A (HSYA) in beagle dog plasma. Plasma samples spiked with the analytes were extracted by solid-phase extraction and the analytes were separated on a 250 × 4.6 mm i.d., 5-μm particle, C18 column with methanol–acetonitrile–0.5% formic acid 20:25:55 (v/v) as mobile phase at a flow rate of 1 mL min?1. LC–MS–MS analysis was performed with a Finnigan TSQ triple-quadrupole tandem mass spectrometer operated in negative-ion selected-reaction-monitoring mode, using electrospray ionization. The accuracy and precision of the method were acceptable and linearity was good over the range 20–4,000 ng mL?1 for danshensu, 50–10,000 ng mL?1 for SAB, and 10–2,000 ng mL?1 for HSYA. The method was successfully applied to a pharmacokinetic study of a traditional Chinese medicinal preparation, Danhong lyophilized powder for injection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号