首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A simple, sensitive, selective and precise liquid-column chromatographic assay for clonazepam is described, in which 1 ml of serum containing 50 micrograms/l methylclonazepam as an internal standard is extracted by elution from a Bond-Elut column with 400 microliter of methanol. An aliquot of the eluate is injected on to a reversed-phase column and eluted with a mobile phase of acetonitrile--phosphate buffer (30:70) at a flow-rate of 2 ml/min at a column temperature of 50 degrees C. Detection is at 254 nm. Chromatography is complete in 12 min. A sensitivity of 2 ng/ml is attained when 1 ml of serum is extracted. Analytical recovery of the clonazepam added to serum ranged from 91% to 99% with a coefficient of variation of 6.0%. This assay for clonazepam has good precision, with coefficients of variation of 11% at 15 ng/ml and 2.6% at 50 ng/ml. There was no interference from any of the commonly used antiepileptics.  相似文献   

2.
An analytical method is described for the determination of the free base of pioglitazone hydrochloride (U72, 107A, AD-4833) in dog serum. The method used solid-phase extraction of pioglitazone from serum followed by high-performance liquid chromatographic analysis on an octadecylsilane column with an eluent of acetonitrile-water (41:59, v/v) containing 1.2 ml/l acetic acid (pH 6.0 +/- 0.05). The column effluent was monitored at 229 nm. The analytical procedure has a linear range of 25 ng/ml to 20 micrograms/ml, a minimum quantifiable level of 25 ng/ml, absolute recovery of greater than 90% (n = 15), and precision of less than or equal to 8.8% (n = 45). The method was used in a preliminary dose proportionality study in the dog.  相似文献   

3.
A simple and sensitive high-performance liquid chromatographic method with ultraviolet detection is described for the simultaneous determination of lansoprazole and its metabolites in human serum and urine. The analytes in serum or urine were extracted with diethyl ether-dichloromethane (7:3, v/v) followed by evaporation, dissolution and injection into a reversed-phase column. The recoveries of authentic analytes added to serum at 0.05-2 micrograms/ml or to urine at 1-20 micrograms/ml were greater than 88%, with the coefficients of variation less than 7.1%. The minimum determinable concentrations of all analytes were 5 ng/ml in serum and 50 ng/ml in urine. The method was successfully applied to a pharmacokinetic study of lansoprazole in human.  相似文献   

4.
A high-performance liquid chromatographic assay has been developed and validated for the determination of centbutindole and its hydroxy metabolite in serum. The method involves extraction of serum samples with diethyl ether at pH greater than 8, back-extraction into 0.5 M hydrochloric acid and finally again with diethyl ether after addition of 2 M potassium hydroxide. Separation was accomplished by reversed-phase high-performance liquid chromatography on a cyano column with an acetonitrile-phosphate buffer system. The recovery of centbutindole and its metabolite was always greater than 80%. Calibration curves were linear over the concentration range 0.25-5 ng/ml for centbutindole and 0.05-1 ng/ml for the hydroxy metabolite. Although the lower limit of detection was 0.1 ng/ml for centbuntindole and 0.02 ng/ml for the hydroxy metabolite, the reliable limits of quantitation were 0.25 and 0.05 ng/ml, respectively, using 4 ml of serum.  相似文献   

5.
A simple, sensitive method for the determination of the prifinium ion, a quaternary ammonium ion, in human serum and urine is described. The method is based on extraction of the test solution with chloroform in the presence of saturated potassium bromide solution and normal-phase high-performance liquid chromatography using aqueous methanol as the mobile phase at pH 10. To prevent the dissolution of silica from the analytical column, the mobile phase is pre-saturated with silica by using a silica saturation column. Quantitation is possible down to 0.5 ng/ml of prifinium ion using 2 ml of serum and down to 5 ng/ml using a 1 ml of urine. The coefficients of variation of the method are less than 1.3% in both serum and urine. Serum levels and urinary excretion data obtained with this method are given for three healthy volunteers who had received a 60-mg oral dose of prifinium bromide.  相似文献   

6.
The chromatographic behaviour of ofloxacin on various sorbents, including ODS, C8, C1, nitril, phenyl and tert,-butyl, as stationary phases was investigated and a high-performance liquid chromatography (HPLC) assay was developed for the determination of ofloxacin in serum. The serum samples were directly introduced onto an HPLC column after filtering through a Morcut II membrane filter to remove proteins. The filtrate was concentrated on a pre-column using a phenyl stationary phase and was then introduced to an analytical column with an ODS stationary phase by column switching. Ofloxacin and enoxacin as an internal standard were detected by ultraviolet absorbance at 300 nm. Determination was possible for ofloxacin over the concentration range 50-2000 ng/ml; the limit of detection was 20 ng/ml. The recovery of ofloxacin added to serum was 88.8-101.7% with a coefficient of variation of less than 5.2%. This method is applicable to pharmacokinetic studies of patients after treatment with ofloxacin.  相似文献   

7.
An assay is presented for the extraction and quantitation of two oximes, 2-hydroxyimino-methyl-3-methyl-1-[2-(3-methyl-3-nitrobutyloxyme thyl)] imidazolium chloride (oxime A) and 1-[1-(3-butynyloxymethyl)]-2-hydroxyiminomethyl-3-methylimidazo lium chloride (oxime B), in human plasma and is demonstrated to be linear over two overlapping concentration ranges: 10-500 and 100-1000 ng/ml. The assay utilizes a liquid-liquid, ion-pair extraction and a normal-phase chromatographic separation on a silica column with ultraviolet detection at 270 nm. The method is sensitive, rapid and accurate. The limit of detection is 10 ng/ml (signal-to-noise ratio S/N greater than 10). The mean extraction recoveries of the oximes were greater than 86% at all concentration levels. The intra-assay variability was less than 3.3%, the inter-assay variability less than 7.2%. The compound is stable in plasma for 23 weeks when stored at -15 degrees C or -80 degrees C.  相似文献   

8.
A novel, sensitive and specific method for the quantitative determination of ivermectin B(1a) in animal plasma using liquid chromatography combined with positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is presented. Abamectin was used as the internal standard. Extraction of the samples was performed with a deproteinization step using acetonitrile. Chromatographic separation was achieved on a Nucleosil ODS 5 microm column, using gradient elution with 0.2% (v/v) acetic acid in water and 0.2% (v/v) acetic acid in acetonitrile. The method was validated according to the requirements defined by the European Community. Calibration curves using plasma fortified between 1 and 100 ng ml(-1) showed a good linear correlation (r > or = 0.9989, goodness-of-fit coefficient < or =8.1%). The trueness at 2 and 25 ng ml(-1) (n = 6) was +4.2 and -17.1%, respectively. The trueness and between-run precision for the analysis of quality control samples at 25 ng ml(-1) was -4.0 and 11.0%, respectively (n = 16). The limit of quantification of the method was 1.0 ng ml(-1), for which the trueness and precision also fell within acceptable limits. Using a signal-to-noise ratio of 3 : 1, the limit of detection was calculated to be 0.2 ng ml(-1). The specificity was demonstrated with respect to ivermectin B(1b).The method was successfully used for the quantitative determination of ivermectin B(1a) in plasma samples from treated bovines, demonstrating the usefulness of the developed method for application in the field of pharmacokinetics.  相似文献   

9.
An isocratic high-performance liquid chromatographic method specifically developed to allow simple and rapid determination of retinol concentrations in serum and plasma is reported. Retinol and retinol acetate (the internal standard) are extracted into butanol-ethyl acetate, with no subsequent evaporation step. Separation is achieved on a reversed-phase C-18 column, with a mobile phase consisting of acetonitrile-1% ammonium acetate (89:11), and UV detection at 313 nm. Recoveries of both retinol and the internal standard were 100%, and both compounds were stable in the extraction solvent for at least 2.5 h. Three anticoagulants (oxalate, citrate, EDTA) and perchloric acid (used in some methods to denature protein) all caused losses of retinol. Each run required 9 min; same-day coefficient of variation (C.V.) for identical samples averaged 2.5%; between-day C.V. was 6.4%; sensitivity was better than 10 ng/ml, while clinical concentrations were 400-1200 ng/ml. This method permits simple, rapid, sensitive, precise, and accurate determination of retinol using 0.5 ml serum or heparinized plasma.  相似文献   

10.
A reversed-phase, two-dimensional, liquid chromatographic method incorporating column switching and electrochemical detection was used for the direct analysis of the dopamine (D2) agonist (-)-2-(N-propyl-N-2-thienylethylamino)-5-hydroxytetralin hydrochloride in plasma. Sample work-up consisted of addition of internal standard, filtration, then direct injection of the plasma sample onto an internal surface reversed-phase (ISRP) guard column where the dopamine agonist and internal standard were separated from plasma proteins. An automated pneumatic valve was then used to switch to a stronger eluent which stripped the retained substances from the ISRP support onto a C18 analytical column where the analytes were separated from endogenous biological interferences. A dual-electrode electrochemical detector was used to minimize interferences and provide the desired sensitivity. The method has a detection limit of 1.5 ng/ml and requires a total assay time of 20 min per plasma sample. The method is linear from 1.5 to 1000 ng/ml and yielded greater than 80% drug recovery for plasma concentrations greater than 10 ng/ml. Precision for the method at 100 ng/ml yielded a relative standard deviation of 4.4%. Reproducibility was within 6.5% on a 20 ng/ml spiked plasma sample assayed on different days by different people. The method has successfully been applied to human plasma samples and for pharmacokinetic studies in rats and monkeys.  相似文献   

11.
A sensitive and selective high-performance liquid chromatographic method has been developed for a new sulphonylurea, glimepiride, and its metabolites. The assay involves extraction with diethyl ether, thermolysis of the sulphonylureas at 100 degrees C and trapping of the resulting amines with 2,4-dinitrofluorobenzene. The derivatives were quantitated on a reversed-phase column by absorbance at 350 nm using a step gradient for the three compounds in serum and an isocratic run for the metabolites in urine. Analogous compounds were used as internal standards. The detection limit was 5 ng/ml for glimepiride and metabolite II and 10 ng/ml for metabolite I using 1 ml of serum. The method has been applied to the analysis of serum and urine samples from pharmacokinetic studies in humans.  相似文献   

12.
A rapid, specific and direct method based on capillary column gas chromatography with electron-capture detection is described for the simultaneous determination of nicardipine, a new calcium antagonist, and its pyridine metabolite II in human plasma. In this method, the nicardipine, its pyridine metabolite II and internal standard are extracted from the plasma and then partially purified by acid-base partitioning prior to the final injection onto the capillary column gas chromatograph for quantification by means of an electron-capture detector. The quantification limit of the method is 1 ng/ml of plasma for both nicardipine and its pyridine metabolite II. The coefficients of variation for nicardipine and the pyridine metabolite II at concentrations of 1-50 ng/ml are less than 7% and less than 9% (n = 4), respectively. The method has been validated against a previously developed high-performance liquid chromatographic method (sensitivity 5 ng/ml).  相似文献   

13.
A simple, rapid and highly sensitive reversed-phase liquid chromatographic method has been developed for the determination of sialic acids in human serum. The sialic acids, released by hydrolysis of serum, are converted in borate buffer with malononitrile to highly fluorescent compounds. The reaction mixture is separated isocratically within 5 min using an octadecyl-bonded silica column and a mobile phase of methanol and ammonium acetate buffer (15:85, v/v; pH 5.5). Measurement of the fluorescence intensity of the reaction mixture at 434 nm with irradiation at 357 nm allowed determination of 30-1000 ng/ml of sialic acids with high reproducibility. The limit of detection was 2 ng/ml. Intra-day and inter-day coefficients of variation for assaying 300 ng/ml N-acetylneuraminic acid (NANA) were 1.5% (n = 9) and 2.6% (n = 7), respectively. The recoveries of NANA were 98.5-101.1% for serum. The method has been used for clinical determinations.  相似文献   

14.
A novel method for the determination of vitamin B12 by high-performance liquid chromatography with fluorescence detection is reported. The method was simple and highly sensitive with good precision. Vitamin B12 was analyzed by HPLC on a muBondapak C18 column (300x3.9 mm, 10 microm) with methanol-water (30:70) as mobile phase and fluorescence detection at 305 nm (with excitation at 275 nm). The calibration graph was linear from 1.000 to 100.0 ng ml(-1) for vitamin B12 with a correlation coefficient of 0.998 (n=6). The detection limit was 0.1 ng ml(-1). The method was successfully applied to the determination of vitamin B12 in vitamin B12 tablets, multivitamin tablets and fermentation medium. The recovery was from 94 to 102% and the relative standard deviation was in the range of 1.8 to 4.1%.  相似文献   

15.
A high-performance liquid chromatographic method is described for the determination of terbutaline in human plasma in the range 1-35 ng/ml. Detection was achieved using a carbon fibre micro-electrochemical detector and a column-switching system. The microelectrode cell has advantages over conventional glassy carbon electrode-based detection systems in that it is easy to prepare, flexible in its operation and suffers less trouble from problems such as air bubbles and leaks. Furthermore, it has a better detection limit for terbutaline (0.8 ng/ml) to that obtained using a conventional glassy carbon electrode flow detector (2 ng/ml). Sample clean-up was by on-line solid-phase extraction with column switching, providing a method which was sensitive and reproducible, where the mean overall coefficient of variation was 5.60% and drug recovery in excess of 86% at the concentration levels studied.  相似文献   

16.
An isocratic high-performance liquid chromatographic (HPLC) method with ultraviolet detection is described for the quantification of the atypical neuroleptic clozapine and its major metabolites, N-desmethylclozapine and clozapine N-oxide, in human serum or plasma. The method included automated solid-phase extraction on C18 reversed-phase material. Clozapine and its metabolites were separated by HPLC on a C18 ODS Hypersil analytical column (5 microns particle size; 250 mm x 4.6 mm I.D.) using an acetonitrile-water (40:60, v/v) eluent buffered with 0.4% (v/v) N,N,N',N'-tetramethylethylenediamine and acetic acid to pH 6.5. Imipramine served as internal standard. After extraction of 1 ml of serum or plasma, as little as 5 ng/ml of clozapine and 10 or 20 ng/ml of the metabolites were detectable. Linearity was found for drug concentrations between 5 and 2000 ng/ml as indicated by correlation coefficients of 0.998 to 0.985. The intra- and inter-assay coefficients of variation ranged between 1 and 20%. Interferences with other psychotropic drugs such as benzodiazepines, antidepressants or neuroleptics were negligible. In all samples, collected from schizophrenic patients who had been treated with daily oral doses of 75-400 mg of clozapine, the drug and its major metabolite, N-desmethylclozapine, could be detected, while the concentrations of clozapine N-oxide were below 20 ng/ml in three of sixteen patients. Using the method described here, data regarding relations between therapeutic or toxic effects and drug blood levels or metabolism may be collected in clinical practice to improve the therapeutic efficacy of clozapine drug treatment.  相似文献   

17.
A method using reversed-phase high-performance liquid chromatography with ultraviolet detection for the determination of ceterizine in serum is described. The method is sensitive down to 50 ng/ml (250-microliter loop). Sample preparation involves only serum deproteination with perchloric acid and injection of the centrifuged supernatant. Elution is at pH 2.5 with acetonitrile-methanol-0.05 M phosphate buffer (33:9:58, v/v) on a 25 cm x 4.6 mm I.D. Spherisorb S5 ODS2 column. Detection is at 211 nm, its lambda max. For levels above 300 ng/ml the serum sample size is 100 microliter and a 200-microliter sample is necessary for concentrations less than 300 ng/ml. At the 2 micrograms/ml concentration the intra-assay relative standard deviation is better than 2.2%, whilst the inter-assay deviation is 2.6% over eight samples. At 200 ng/ml the intra-assay relative standard deviation is 6% over seven samples. Detector response is linear from 100 ng/ml to 10 micrograms/ml (100-microliter loop).  相似文献   

18.
The objective of this study was to develop a very sensitive and selective method for the determination of detajmium (4-3-diethylamino-2-hydroxypropyl-ajmaline), a sodium-channel-blocking drug with antiarrhythmic properties, in serum. A high-performance liquid chromatography (HPLC) method with solid-phase extraction and fluorimetric detection has been applied. Serum samples were diluted with phosphate buffer (pH 3.5) and the extraction of detajmium and ajmaline, which was used as an internal standard, was carried out with Oasis cartridges (Waters). The chromatographic separation was performed on a RP18 column. The limit of quantification for serum samples of detajmium was 1 ng/ml with good reproducibility (R.S.D. < 15%) and a linear response from 1 to 200 ng/ml. The described method is highly sensitive and specific for the determination of detajmium in serum of patients and volunteers.  相似文献   

19.
From the clinical use of RIA-gnost trypsin kit, the following results were obtained. 1. Standard curve showed a steep and good curve was shown. 2. Incubation: The condition for the first incubation was set at the room temperature for 10-24 hours and that for the second incubation at the room temperature for 3-5 hours. With these settings, satisfactory results were obtained. 3. Reproducibility and recovery: The C.V. of the reproducibility and the recovery were considered superior, and the values were below 10% and +/- 3%, respectively. 4. Correlation between trypsin and serum elestase-1: An excellent positive correlation (coefficient of correlation r = 0.889) was shown. 5. Serum trypsin concentration of normal and pancreatic diseases: The normal range was from 100 to 500 ng/ml. Acute pancreatitis rose obviously. Diabetes mellitus and chronic pancreatitis was below 500 ng/ml and the pancreatic cancer showed a tendency to scatter in the range of 50-1,250 ng/ml. The above results indicated that serum trypsin can be easily measured with high precision by using this method. Thus the method is considered useful for the diagnosis of pancreatic diseases.  相似文献   

20.
A selective method for measuring tricyclic antidepressants in serum is reported. A single assay can be done within ca. 30 min and eight samples can be assayed in less than 150 min. A 1-ml serum sample was diluted and the drugs were extracted from it by passage through a graphitized carbon black (Carbopack B) cartridge. After one washing, this cartridge was connected on line to another one containing a silica-based strong acid exchanger. The tricyclics were removed from the Carbopack surface and selectively readsorbed onto the cation-exchange surface by passing 4 ml of methylene chloride-methanol (60:40, v/v) through the two cartridges. After another wash, the drugs were desorbed from the cation-exchange surface with 0.8 ml of acetonitrile-methanol-water (72:18:10, v/v) saturated with potassium chloride. An aliquot of this solution was chromatographed on a cyano column, and the absorbance of the effluent was measured at 215 nm. The mean analytical recoveries of tricyclic antidepressants added to serum within the range 10-200 micrograms/l exceeded 90%, except for 8-hydroxyamoxapine (mean recovery 85.3%) and amoxapine (mean recovery 83.8%) at the lowest serum concentration considered.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号