首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Drug bioactivation leading to the formation of reactive species capable of covalent binding to proteins represents an important cause of drug‐induced toxicity. Reactive metabolite detection using in vitro microsomal incubations is a crucial step in assessing potential toxicity of pharmaceutical compounds. The most common method for screening the formation of these unstable, electrophilic species is by trapping them with glutathione (GSH) followed by liquid chromatography/mass spectrometry (LC/MS) analysis. The present work describes the use of a brominated analog of glutathione, N‐(2‐bromocarbobenzyloxy)‐GSH (GSH‐Br), for the in vitro screening of reactive metabolites by LC/MS. This novel trapping agent was tested with four drug compounds known to form reactive metabolites, acetaminophen, fipexide, trimethoprim and clozapine. In vitro rat microsomal incubations were performed with GSH and GSH‐Br for each drug with subsequent analysis by liquid chromatography/high‐resolution mass spectrometry on an electrospray time‐of‐flight (ESI‐TOF) instrument. A generic LC/MS method was used for data acquisition, followed by drug‐specific processing of accurate mass data based on mass defect filtering and isotope pattern matching. GSH and GSH‐Br incubations were compared to control samples using differential analysis (Mass Profiler) software to identify adducts formed via the formation of reactive metabolites. In all four cases, GSH‐Br yielded improved results, with a decreased false positive rate, increased sensitivity and new adducts being identified in contrast to GSH alone. The combination of using this novel trapping agent with powerful processing routines for filtering accurate mass data and differential analysis represents a very reliable method for the identification of reactive metabolites formed in microsomal incubations. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
A need still exists for a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method that can detect broad classes of glutathione (GSH) conjugates and provide characterization of their structures. We now describe the development of a method that multiplexes high-resolution accurate mass analysis with isotope pattern triggered data-dependent product ion scans, for simultaneous detection and structural elucidation of GSH conjugates within a single analysis using a LTQ/Orbitrap. This method was initially developed to detect GSH conjugates generated from incubating 10 microM test compound with pooled human liver microsomes fortified with NADPH-regenerating system and a 2:1 ratio of 5 mM glutathione and [(13)C(2) (15)N-Gly]glutathione. The GSH conjugates were detected by isotope search of mass defect filtered and control subtracted full scan accurate MS data using MetWorks software. This was followed by elucidation of reactive intermediate structures using chemical formulae for both protonated molecules and their product ions from accurate masses in a single analysis. The mass accuracies measured for the precursor and product ions by the Orbitrap were <2 ppm in external mass calibration mode. Successful detection and characterization of GSH conjugates of acetaminophen, tienilic acid, clozapine, ticlopidine and mifepristone validated this method. In each case, the detected GSH conjugates were within the top five hits by isotope search. This method also has a broader detection capability since it is independent of the collision-induced dissociation behavior of the GSH conjugates. Furthermore, this method is amenable to a broad class of reactive intermediate trapping agents as exemplified by the simultaneous detection and structural elucidation of the cyano-N-methylene iminium ion conjugates of verapamil and its O-desmethyl metabolites, which we report for the first time. In addition to the chemically tagged reactive intermediates, this method also provides information on stable metabolites from the full scan accurate MS data.  相似文献   

3.
The in vitro metabolism of the nootropic drug fipexide was studied using different liquid chromatography/mass spectrometry (LC/MS) techniques. This drug has been withdrawn from the market due to toxic effects. No previous reports have investigated the possible involvement of reactive metabolites in the toxicity of fipexide. The hydrolysis of this drug leads to the formation of two potentially toxic species, 3,4-methylenedioxybenzylpiperazine (MDBP) and 4-chlorophenoxyacetic acid (4-CPA). Here, we investigate the in vitro metabolism of fipexide in human, rat, mouse and dog, as well as of MDBP and 4-CPA in human and rat, while focusing on the formation of reactive metabolites. A combination of LC/MS analyses on a hybrid quadrupole-linear ion trap instrument and accurate mass data from QqTOF measurements was employed for the characterization of these metabolites. Microsomal metabolites of fipexide were MDBP, 4-CPA, fipexide N-oxide or hydroxyl, demethylenated fipexide and other minor ones, all of which were investigated by tandem mass spectrometry. Reactive metabolites were detected using several trapping procedures with small molecules such as glutathione, its ethyl ester derivative and N-acetylcysteine. The demethylenated metabolite, a catechol, formed its corresponding ortho-quinone, which readily reacts with these nucleophiles. MDBP was studied in a similar manner, due to its ability to form an analogous catechol. Because of its acidic nature, 4-CPA was assessed for possible acylglucuronide and acyl-CoA thioester metabolites, which could also be involved in bioactivation pathways. Several important metabolites were identified as potential mediators of toxicity via protein binding.  相似文献   

4.
Lu J  Wang X  Xu Y  Dong Y  Yang S  Wu Y  Qin Y  Wu M 《The Analyst》2011,136(3):467-472
The metabolism and excretion of toremifene were investigated in one healthy male volunteer after a single oral administration of 120 mg toremifene citrate. Different liquid chromatographic/tandem mass spectrometric (LC/MS/MS) scanning techniques were carried out for the characterization of the metabolites in human urine for doping control purposes. The potential characteristic fragmentation pathways of toremifene and its major metabolites were presented. An approach for the metabolism study of toremifene and its analogs by liquid chromatography-tandem mass spectrometry was established. Five different LC/MS/MS scanning methods based on precursor ion scan (precursor ion scan of m/z 72.2, 58.2, 44.2, 45.2, 88.2 relative to five metabolic pathways) in positive ion mode were assessed to recognize the metabolites. Based on product ion scan and precursor ion scan techniques, the metabolites were proposed to be identified as 4-hydroxy-toremifene (m/z 422.4), 4'-hydroxy-toremifene (m/z 422.4), α-hydroxy-toremifene (m/z 422.4), 3,4-dihydroxy-toremifene (m/z 404.2), toremifene acid (m/z 402.2), 3-hydroxy-4-methoxy-toremifene (m/z 456.2), dihydroxy-dehydro-toremifene (m/z 440.2), 3,4-dihydroxy-toremifene (m/z 438.2), N-demethyl-4-hydroxy-toremifene (m/z 408.3), N-demethyl-3-hydroxy-4-methoxy-toremifene (m/z 438.3). In addition, a new metabolite with a protonated molecule at m/z 390.3 was detected in all urine samples. The compound was identified by LC/MS/MS as N-demethyl-4,4'-dihydroxy-tamoxifene. The results indicated that 3,4-dihydroxy-toremifene (m/z 404.2), toremifene acid (m/z 402.2) and N-demethyl-4,4'-dihydroxy-tamoxifene (m/z 390.3) were major metabolites in human urine.  相似文献   

5.
The detection of the reactive metabolites of drugs has recently been gaining increasing importance. In vitro trapping studies using trapping agents such as glutathione are usually conducted for the detection of reactive metabolites, especially those of cytochrome P450‐mediated metabolism. In order to detect the UDP‐glucuronosyltransferase (UGT)‐mediated bioactivation of drugs, an in vitro trapping method using N‐acetylcysteine (NAC) as a trapping agent followed by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed in this study. After the test compounds (diclofenac and ketoprofen) had been incubated in human liver microsomes with uridine diphosphoglucuronic acid (UDPGA) and NAC, the NAC adducts formed through their acyl glucuronides were analyzed using LC/MS/MS with electrospray ionization (ESI). The NAC adduct showed a mass shift of 145 units as compared to its parent, and the characteristic ion fragmentations reflected the parent. This is a concise and high‐throughput method for evaluating reactive metabolites by UGT‐mediated bioactivation. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
Chemically reactive metabolites may cause hepatotoxicity and as a result liver failure or other adverse side reactions. Therefore, this is a vital topic of interest because early reactive metabolite screening may prevent compound failure at a later stage. In order to address this issue, a screening assay has been developed to detect the formation of reactive metabolites by using glutathione as a trapping reagent, which will allow us to search for phase I metabolites and also glutathiones during in vitro metabolite screening using liquid chromatography/tandem mass spectrometry (LC/MS/MS) with exact mass. Glutathione conjugations when fragmented by the mass spectrometer give a common loss corresponding to the pyroglutamic acid moiety, which can be monitored. Until recently, this work has been carried out with triple quadrupole technology using nominal mass. The advantage of the hybrid quadrupole time-of-flight mass spectrometer is the selectivity and sensitivity that can be achieved. Exact neutral loss detection is achieved via sequential low- and high-energy MS acquisitions. After detection of the loss of the pyroglutamic acid moiety, using a window of +/-20 mDa on the high-energy scan, MS/MS is carried out on the parent mass of interest to confirm the common neutral loss.  相似文献   

7.
The knowledge of drug metabolism in the early phases of the drug discovery process is vital for minimising compound failure at later stages. As chemically reactive metabolites may cause adverse drug reactions, it is generally accepted that avoiding formation of reactive metabolites increases the chances of success of a molecule. In order to generate this important information, a screening strategy for the rapid detection of in vitro generated reactive metabolites trapped by glutathione has been developed. The bioassay incorporated the use of native glutathione and its close analogue the glutathione ethyl ester. The generic conditions for detecting glutathione conjugates that undergo constant neutral loss of 129 Da were optimised using a glutathione‐based test mix of four compounds. The final liquid chromatography/tandem mass spectrometry constant neutral loss method used low‐resolution settings and a scanning window of 200 amu. Data mining was rapidly and efficiently performed using LightSight® software. Unambiguous identification of the glutathione conjugates was significantly facilitated by the analytical characteristics of the conjugate pairs formed with glutathione and glutathione ethyl ester, i.e. by chromatographic retention time and mass differences. The reliability and robustness of the screening strategy was tested using a number of compounds known to form reactive metabolites. Overall, the developed screening strategy provided comprehensive and reliable identification of glutathione conjugates and is well suited for rapid routine detection of trapped reactive metabolites. This new approach allowed the identification of a previously unreported diclofenac glutathione conjugate. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
The formation of reactive metabolites from a number of compounds was studied in vitro using a mixture of non-labeled and stable isotope labeled glutathione (GSH) as a trapping agent. GSH was labeled by incorporating [1,2-(13)C(2),(15)N]glycine into the tripeptide to give an overall increase of 3 Da over the naturally occurring substance. Detection and characterization of reactive metabolites was greatly facilitated by using the data-dependent scanning features of the linear ion trap mass spectrometers to give complimentary and confirmatory data in a single analytical run. A comparison was made by analyzing the samples simultaneously on a triple-stage quadrupole mass spectrometer operated in the constant neutral loss mode. The compounds studied included 2-acetamidophenol, 3-acetamidophenol, 4-acetamidophenol (acetaminophen), and flufenamic acid. GSH adducts for each of these compounds produced a characteristic pattern of 'twin ions' separated by 3 Da in the mass spectral data. This greatly facilitated the detection and characterization of any GSH-related adducts present in the microsomal extracts. Furthermore, characterization of these adducts was greatly facilitated by the rapid scanning capability of linear ion trap instruments that provided full-scan, MS/MS and MS(3) data in one single analysis. This method of detecting and characterizing reactive metabolites generated in vitro was found to be far superior to any of the existing methods previously employed in this laboratory. The combination of two techniques, stable isotope labeled glutathione and linear ion traps, provided a very sensitive and specific method of identifying compounds capable of producing reactive metabolites in a discovery setting. The complimentary set of mass spectral data (including full-scan, MS/MS and MS(3) mass spectra), obtained rapidly in a single analysis with the linear ion trap instruments, greatly accelerated identification of metabolically bioactivated soft spots on the molecules. This in turn enabled chemists to rapidly design out the potential metabolic liability from the back-up compounds by making appropriate structural modifications.  相似文献   

9.
Reactive metabolites are believed to be one of the main reasons for unexpected drug‐induced toxicity issues, by forming covalent adducts with cell proteins or DNA. Due to their high reactivity and short lifespan they are not directly detected by traditional analytical methods, but are most traditionally analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS) after chemical trapping with nucleophilic agents such as glutathione. Here, a simple but very efficient assay was built up for screening reactive drug metabolites, utilizing stable isotope labeled glutathione, potassium cyanide and semicarbazide as trapping agents and highly sensitive ultra‐performance liquid chromatography/time‐of‐flight mass spectrometry (UPLC/TOFMS) as an analytical tool. A group of twelve structurally different compounds was used as a test set, and a large number of trapped metabolites were detected for most of them, including many conjugates not reported previously. Glutathione‐trapped metabolites were detected for nine of the twelve test compounds, whereas cyanide‐trapped metabolites were found for eight and semicarbazide‐trapped for three test compounds. The high mass accuracy of TOFMS provided unambiguous identification of change in molecular formula by formation of a reactive metabolite. In addition, use of a mass defect filter was found to be a usable tool when mining the trapped conjugates from the acquired data. The approach was shown to provide superior detection sensitivity in comparison to traditional methods based on neutral loss or precursor ion scanning with a triple quadrupole mass spectrometer, and clearly more efficient detection and characterization of reactive drug metabolites with a simpler test setup. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
We report herein, facile metabolite identification workflow on the anti-depressant nefazodone, which is derived from accurate mass measurements based on a single run/experimental analysis. A hybrid LTQ/orbitrap mass spectrometer was used to obtain accurate mass full scan MS and MS/MS in a data-dependent fashion to eliminate the reliance on a parent mass list. Initial screening utilized a high mass tolerance ( approximately 10 ppm) to filter the full scan MS data for previously reported nefazodone metabolites. The tight mass tolerance reduces or eliminates background chemical noise, dramatically increasing sensitivity for confirming or eliminating the presence of metabolites as well as isobaric forms. The full scan accurate mass analysis of suspected metabolites can be confirmed or refuted using three primary tools: (1) predictive chemical formula and corresponding mass error analysis, (2) rings-plus-double bonds, and (3) accurate mass product ion spectra of parent and suspected metabolites. Accurate mass characterization of the parent ion structure provided the basis for assessing structural assignment for metabolites. Metabolites were also characterized using parent product ion m/z values to filter all tandem mass spectra for identification of precursor ions yielding similar product ions. Identified metabolite parent masses were subjected to chemical formula calculator based on accurate mass as well as bond saturation. Further analysis of potential nefazodone metabolites was executed using accurate mass product ion spectra. Reported mass measurement errors for all full scan MS and MS/MS spectra was <3 ppm, regardless of relative ion abundance, which enabled the use of predictive software in determining product ion structure. The ability to conduct biotransformation profiling via tandem mass spectrometry coupled with accurate mass measurements, all in a single experimental run, is clearly one of the most attractive features of this methodology.  相似文献   

11.
Drugs can be metabolically activated to soft and hard electrophiles, which are readily trapped by glutathione (GSH) and cyanide (CN), respectively. These adducts are often detected and structurally characterized using separate tandem mass spectrometry methods. We describe a new method for simultaneous screening of GSH and CN adducts using precursor ion (PI) and neutral loss (NL) scans-dependent product ion spectral acquisition and data mining tools on an triple quadrupole linear ion trap mass spectrometry. GSH, potassium cyanide, and their stable isotope labeled analogues were incubated with liver microsomes and a test compound. Negative PI scan of m/z 272 for detection of GSH adducts and positive NL scans of 27 and 29 Da for detection of CN adducts were conducted as survey scans to trigger acquisition of enhanced resolution (ER) spectrum and subsequent enhanced product ion (EPI) spectrum. Post-acquisition data mining of EPI data set using NL filters of 129 and 27 Da was then performed to reveal the GSH adducts and CN adducts, respectively. Isotope patterns and EPI spectra of the detected adducts were utilized for identification of their molecular weights and structures. The effectiveness of this method was evaluated by analyzing reactive metabolites of nefazodone formed from rat liver microsomes. In addition to known GSH- and CN-trapped reactive metabolites, several new CN adducts of nefazodone were identified. The results suggested that current approach is highly effective in the analysis of both soft and hard reactive metabolites and can be used as a high-throughput method in drug discovery.  相似文献   

12.
Electrophilic reactive metabolite screening by liquid chromatography/mass spectrometry (LC/MS) is commonly performed during drug discovery and early-stage drug development. Accurate mass spectrometry has excellent utility in this application, but sophisticated data processing strategies are essential to extract useful information. Herein, a unified approach to glutathione (GSH) trapped reactive metabolite screening with high-resolution LC/TOF MS(E) analysis and drug-conjugate-specific in silico data processing was applied to rapid analysis of test compounds without the need for stable- or radio-isotope-labeled trapping agents. Accurate mass defect filtering (MDF) with a C-heteroatom dealkylation algorithm dynamic with mass range was compared to linear MDF and shown to minimize false positive results. MS(E) data-filtering, time-alignment and data mining post-acquisition enabled detection of 53 GSH conjugates overall formed from 5 drugs. Automated comparison of sample and control data in conjunction with the mass defect filter enabled detection of several conjugates that were not evident with mass defect filtering alone. High- and low-energy MS(E) data were time-aligned to generate in silico product ion spectra which were successfully applied to structural elucidation of detected GSH conjugates. Pseudo neutral loss and precursor ion chromatograms derived post-acquisition demonstrated 50.9% potential coverage, at best, of the detected conjugates by any individual precursor or neutral loss scan type. In contrast with commonly applied neutral loss and precursor-based techniques, the unified method has the advantage of applicability across different classes of GSH conjugates. The unified method was also successfully applied to cyanide trapping analysis and has potential for application to alternate trapping agents.  相似文献   

13.
Multiple ion monitoring (MIM)‐dependent acquisition with a triple quadrupole‐linear ion trap mass spectrometer (Q‐trap) was previously developed for drug metabolite profiling. In the analysis, multiple predicted metabolite ions are monitored in both Q1 and Q3 regardless of their fragmentations. The collision energy in Q2 is set to a low value to minimize fragmentation. Once an expected metabolite is detected by MIM, enhanced product ion (EPI) spectral acquisition of the metabolite is triggered. To analyze in vitro metabolites, MIM‐EPI retains the sensitivity and selectivity similar to that of multiple reaction monitoring (MRM)‐EPI in the analysis of in vitro metabolites. Here we present an improved approach utilizing MIM‐EPI for data acquisition and multiple data mining techniques for detection of metabolite ions and recovery of their MS/MS spectra. The postacquisition data processing tools included extracted ion chromatographic analysis, product ion filtering and neutral loss filtering. The effectiveness of this approach was evaluated by analyzing oxidative metabolites of indinavir and glutathione (GSH) conjugates of clozapine and 4‐ethylphenol in liver microsome incubations. Results showed that the MIM‐EPI‐based data mining approach allowed for comprehensive detection of metabolites based on predicted protonated molecules, product ions or neutral losses without predetermination of the parent drug MS/MS spectra. Additionally, it enabled metabolite detection and MS/MS acquisition in a single injection. This approach is potentially useful in high‐throughout screening of metabolic soft spots and reactive metabolites at the drug discovery stage. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Reactive metabolites are estimated to be one of the main reasons behind unexpected drug-induced toxicity, by binding covalently to cell proteins or DNA. Due to their high reactivity and short lifespan, reactive metabolites are analyzed after chemical trapping with nucleophilic agents such as glutathione or cyanide. Recently, unexplained and uncharacterized methylated reaction products were reported in a human liver microsome based reactive metabolite trapping assay utilizing potassium cyanide as a trapping agent. Here, a similar assay was utilized to produce mono- or dimethylated and further cyanide-trapped reaction products from propranolol, amlodipine and ciprofloxacin, followed by ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC/TOF-MS) and ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) experiments for their more detailed structural elucidation. Formation of all observed cyanide-trapped products was clearly NADPH-dependent and thus metabolism-mediated. The suggested reaction pathways included N-methylation leading to iminium formation in primary and/or secondary amines preceded by cytochrome P450 (CYP)-mediated reactions. As the methylation reaction was suggested to be involved in formation of the actual reactive iminium ion, the observed cyanide-trapped products were experimental artifacts rather than trapped reactive metabolites. The results stress that to avoid overestimating the formation of reactive metabolites in vitro, this methylation phenomenon should be taken into account when interpreting the results of cyanide-utilizing reactive metabolite trapping assays. This in turn emphasizes the importance of identification of the observed cyano conjugates during such studies. Yet, metabolite identification has a high importance to avoid overestimation of in vitro metabolic clearance in the cases where this kind of metabonate formation has a high impact in the disappearance rate of the compound.  相似文献   

15.
Polarity switching mass spectrometry is an efficient way to collect structural data on drug metabolites. The value of this approach is illustrated with the in vitro metabolism of RO9237. Metabolites are identified by positive and negative electrospray ionization (ESI) full scan mass spectrometry, MS/MS and MS(3) using unlabelled and (14)C-radiolabelled versions of the drug. Comparison of the relative detectability of these metabolites by +ESI and -ESI shows that neither ESI mode is universal. It is advantageous to screen for metabolites using both positive and negative ionization modes. This is especially true for phase II metabolism which tends to make molecules more polar and often more acidic. Identification of phase II metabolites also benefits greatly from MS(3) experiments because the conjugating groups typically are cleaved in MS/MS and information on the core structure is only obtained in MS(3). A special case of phase II metabolism is the generation of glutathione (GSH) conjugates from reactive metabolites. The detection of GSH conjugates also benefits from generating both positive and negative ESI mass spectral data.  相似文献   

16.
Fipexide is a nootropic drug, withdrawn from the market due to its idiosyncratic drug reactions causing adverse effects in man. Previous work on its metabolites has identified several potential reactive metabolites which could be implicated in protein binding. Here, we investigated the formation of these metabolites in rat and human hepatocytes. Based on these results, the o-quinone of fipexide (FIP), formed via the demethylenation reaction through a catechol intermediate, was chosen for further investigation. Studies were then pursued in order to relate this metabolite to protein binding, and thus better understand potential mechanisms for the toxicity of the parent compound. An assay was developed for determining the fipexide catechol-cysteine adduct in the microsomal protein fractions following in vitro incubations. This method digests the entire protein fraction into amino acids, followed by the detection of the Cys-metabolite adduct by liquid chromatography/mass spectrometry (LC/MS). We have designed a strategy where drug metabolism taking place in microsomal incubations and involved in protein binding can be assessed after the proteins have been digested, with the detection of the specific amino acid adduct. In this study, the structure of the fipexide adduct was hypothesized using knowledge previously gained in glutathione and N-acetylcysteine trapping experiments. Acetaminophen was used as a positive control for detecting a drug metabolite-cysteine adduct by LC/MS. This approach has the potential to be applicable as a protein-binding assay in early drug discovery without the need for radioactive compounds.  相似文献   

17.
A control sample background-subtraction algorithm was developed for thorough subtraction of background and matrix-related signals in high-resolution, accurate mass liquid chromatography/mass spectrometry (LC/MS) data to reveal ions of interest in an analyte sample. This algorithm checked all ions in the control scans within a specified time window around the analyte scan for potential subtraction of ions found in that analyte scan. Applying this method, chromatographic fluctuations between runs were dealt with and background and matrix-related signals in the sample could be thoroughly subtracted. The effectiveness of this algorithm was demonstrated using four test compounds, clozapine, diclofenac, imipramine, and tacrine, to reveal glutathione (GSH)-trapped reactive metabolites after incubation with human liver microsomes supplemented with GSH (30 microM compound, 45-min incubation). Using this algorithm with a +/- 1.0 min control scan time window, a +/- 5 ppm mass error tolerance, and appropriate control samples, the GSH-trapped metabolites were revealed as the major peaks in the processed LC/MS profiles. Such profiles allowed for comprehensive and reliable identification of these metabolites without the need for any presumptions regarding their behavior or properties with respect to mass spectrometric detection. The algorithm was shown to provide superior results when compared to several commercially available background-subtraction algorithms. Many of the metabolites detected were doubly charged species which would be difficult to detect with traditional GSH adduct screening techniques, and thus, some of the adducts have not previously been reported in the literature. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

18.
Screening for conjugates formed by the tripeptide glutathione with new chemical entities is an essential step during the drug discovery process, as the formation of these conjugates serves as an indicator for the presence of reactive electrophilic intermediates. To increase the selectivity and throughput of this analysis, various mass spectral scan types have evolved over time. Historically, samples were analyzed under positive ionization conditions for the neutral loss of m/z 129 (loss of the pyroglutamic acid moiety from glutathione); however, more recently, negative precursor ion scanning for the loss of m/z 272 (deprotonated gamma-glutamyl-dehydroalanyl-glycine from glutathione) has emerged as a more selective tool. Further increasing the selectivity, we report on an extension of this methodology by incorporating a simultaneous dual negative precursor ion scan for two commonly observed ion fragments from glutathione conjugates, m/z 272 and 254 (the dehydrated form of m/z 272). This negative dual precursor ion scan methodology was first validated using substrates known to undergo metabolic bioactivation (diclofenac, carbamazepine, and 3-methyl indole) and has then been applied to the routine analysis of proprietary compounds undergoing active lead optimization. In comparison to alternative scan methodologies, the increased selectivity offered by this simultaneous dual precursor method results in a reduction in the generation of false positive results as well as reduced data interpretation time.  相似文献   

19.
Icotinib, 4-[(3-ethynylphenyl)amino]-6,7-benzo-12-crown-4-quinazoline, is a new antitumor agent. The metabolic pathway of icotinib in rats was studied using liquid chromatography/tandem mass spectrometry (LC/MS(n)) analysis. Full scan and selected ion monitoring modes were used to profile the possible metabolites of icotinib in rat urine, feces and bile samples. Four phase I metabolites (M1-M4) and two phase II metabolites (M5, M6) were detected and characterized. Multiple-stage mass spectrometry and nuclear magnetic resonance (NMR) spectrometry were employed to elucidate structures of metabolites. Icotinib was metabolized to open the crown ether ring to form the main phase I metabolites. During metabolism, a reactive metabolite was formed. Using semicarbazide as a trapping agent, an intermediate arising from opening of the crown ether ring was detected as an aldehyde product by LC/MS/MS. These data indicated that ring opening of the crown ether was triggered by hydroxylation at the 8'-position of the ring to form a hemiacetal intermediate, which was further oxidized or reduced. Finally, the metabolic pathway of icotinib in rats was proposed.  相似文献   

20.
This paper describes the complete profiling and characterization of in vitro metabolites of the antidepressant agent nefazodone (NEF) generated by human liver microsome (HLM). Two new metabolic pathways (biotransformation) for NEF have been discovered by the characterization of three new metabolites, including two new metabolites (M24, M25) formed due to the N-dealkylation reaction that occurred between the triazolone and propyl units, and one new metabolite (M26) formed due to the O-dearylation reaction that occurred on the phenoxyethyl unit. These metabolites were initially detected by a 4000 Q-Trap instrument and then confirmed by exact mass measurement using an LTQ-Orbitrap. Both instruments proved to be capable of providing complete in vitro metabolite information in a single liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis, although each had its advantages and disadvantages. One noticeable disadvantage of the 4000 Q-Trap was the reduced quality of isotopic pattern in the enhanced mass scan (EMS) spectrum when it was used as survey scan to trigger multiple dependent product ion scans. The problem was especially exacerbated for minor metabolites with low signal intensity. On the other hand, the LTQ-Orbitrap maintained excellent isotopic pattern when used as a full scan survey scan. Twenty-six metabolites were detected and identified. The formation of these new metabolites was also confirmed by analyzing duplicate incubations at different time points.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号