首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work demonstrates the detection of E. coli using a 2-dimensional photosensor array biochip which is efficiently equipped with a microfluidics sample/reagent delivery system for on-chip monitoring of bioassays. The biochip features a 4 x 4 array of independently operating photodiodes that are integrated along with amplifiers, discriminators and logic circuitry on a single platform. The microfluidics system includes a single 0.4 mL reaction chamber which houses a sampling platform that selectively captures detection probes from a sample through the use of immobilized bioreceptors. The independently operating photodiodes allow simultaneous monitoring of multiple samples. In this study the sampling platform is a cellulosic membrane that is exposed to E. coli organisms and subsequently analyzed using a sandwich immunoassay involving a Cy5-labeled antibody probe. The combined effectiveness of the integrated circuit (IC) biochip and the immunoassay is evaluated for assays performed both by conventional laboratory means followed by detection with the IC biochip, and through the use of the microfluidics system for on-chip detection. Highlights of the studies show that the biochip has a linear dynamic range of three orders of magnitude observed for conventional assays, and can detect 20 E. coli organisms. Selective detection of E. coli in a complex medium, milk diluent, is also reported for both off-chip and on-chip assays.  相似文献   

2.
Knowledge of the lipids present in individual preimplantation embryos is of interest in fundamental studies of embryology, in attempts to understand cellular pluripotency and in optimization of in vitro culture conditions necessary for the application and development of biotechnologies such as in vitro fertilization and transgenesis. In this work, the profiles of fatty acids and phospholipids (PL) in individual mouse preimplantation embryos and oocytes were acquired using an analytical strategy based on desorption electrospray ionization mass spectrometry (DESI-MS). The methodology avoids sample preparation and provides information on the lipids present in these microscopic structures. Differences in the lipid profiles observed for unfertilized oocytes, two- and four-cell embryos, and blastocysts were characterized. For a representative set of embryos (N?=?114) using multivariate analysis (specifically principal component analysis) unfertilized oocytes showed a narrower range of PL species than did blastocysts. Two- and four-cell embryos showed a wide range of PLs compared with unfertilized oocytes and high abundances of fatty acids, indicating pronounced synthetic activity. The data suggest that the lipid changes observed in mouse preimplantation development reflect acquisition of a degree of cellular membrane functional and structural specialization by the blastocyst stage. It is also noteworthy that embryos cultured in vitro from the two-cell through the blastocyst stage have a more homogeneous lipid profile as compared with their in vivo-derived counterparts, which is ascribed to the restricted diversity of nutrients present in synthetic culture media. The DESI-MS data are interpreted from lipid biochemistry and previous reports on gene expression of diverse lipids known to be vital to early embryonic development.  相似文献   

3.
The number of cells in a preimplantation embryo is directly correlated to the health and viability of the embryo. There are currently no methods to count the number of cells in late-stage preimplantation embryos noninvasively. We assessed the ability of optical quadrature microscopy (OQM) to count the number of cells in mouse preimplantation embryos noninvasively. First, to test for possible light toxicity, we exposed two-cell mouse embryos to OQM and differential interference contrast (DIC) microscopy and assessed their ability to develop to the blastocyst stage. We found no inhibition of development from either mode of microscopy for up to 2 h of light exposure. We also imaged eight-cell to morula stage mouse preimplantation embryos by OQM nd developed two methods for counting the number of cells. The contour signature method (CSM) used OQM images alone and the phase subtraction method (PSM) used both OQM and DIC images. We compared both methods to standard cell counting techniques and found that the PSM was superior to all other noninvasive cell counting methods. Our work on mouse embryos should be applicable to human embryos. The ability to correctly count the number of cells in human preimplantation embryos could lead to the transfer of fewer embryos in in vitro fertilization (IVF) clinics and consequently a lower rate of high-risk multiple-infant births.  相似文献   

4.
This work demonstrates the detection of E. coli using a 2-dimensional photosensor array biochip which is efficiently equipped with a microfluidics sample/reagent delivery system for on-chip monitoring of bioassays. The biochip features a 4 × 4 array of independently operating photodiodes that are integrated along with amplifiers, discriminators and logic circuitry on a single platform. The microfluidics system includes a single 0.4 mL reaction chamber which houses a sampling platform that selectively captures detection probes from a sample through the use of immobilized bioreceptors. The independently operating photodiodes allow simultaneous monitoring of multiple samples. In this study the sampling platform is a cellulosic membrane that is exposed to E. coli organisms and subsequently analyzed using a sandwich immunoassay involving a Cy5-labeled antibody probe. The combined effectiveness of the integrated circuit (IC) biochip and the immunoassay is evaluated for assays performed both by conventional laboratory means followed by detection with the IC biochip, and through the use of the microfluidics system for on-chip detection. Highlights of the studies show that the biochip has a linear dynamic range of three orders of magnitude observed for conventional assays, and can detect 20 E. coli organisms. Selective detection of E. coli in a complex medium, milk diluent, is also reported for both off-chip and on-chip assays. Received: 13 October 2000 / Revised: 13 November 2000 / Accepted: 13 November 2000  相似文献   

5.
Qureshi A  Gurbuz Y  Niazi JH 《The Analyst》2011,136(13):2726-2734
A new capacitive biochip was developed using carboxy-CNT activated gold interdigitated (GID) capacitors immobilized with E. coli cells for the detection of cellular stress caused by chemicals. Here, acetic acid, H(2)O(2) and NaCl were employed as model chemicals to test the biochip and monitored the responses under AC electrical field by non-Faradaic electrochemical impedance spectroscopy (nFEIS). The electrical properties of E. coli cells under different stresses were studied based on the change in surface capacitance as a function of applied frequency (300-600 MHz) in a label-free and noninvasive manner. The capacitive response of the E. coli biochip under normal conditions exhibited characteristic dispersion peaks at 463 and 582 MHz frequencies. Deformation of these signature peaks determined the toxicity of chemicals to E. coli on the capacitive biochip. The E. coli cells were sensitive to, and severely affected by 166-498 mM (1-3%) acetic acid with declined capacitance responses. The E. coli biochip exposed to H(2)O(2) exhibited adaptive responses at lower concentrations (<2%), while at a higher level (882 mM, 3%), the capacitance response declined due to oxidative toxicity in cells. However, E. coli cells were not severely affected by high NaCl levels (513-684 mM, 3-4%) as the cells tend to resist the salt stress. Our results demonstrated that the biochip response at a particular frequency enabled the determination of the severity of the stress imposed by chemicals and it can be potentially applied for monitoring unknown chemicals as an indicator of cytotoxicity.  相似文献   

6.
Detection of apoptosis is one of the main criteria of preimplantation embryo growth potential assessment. Recent developments in lab-on-a-chip techniques has led to apoptosis detection and monitoring on a single cell or embryo level. However, single embryo apoptosis detection without a change in embryo developmental competence and post-examination "recovery" still remains a challenge. In this paper we present a lab-on-a-chip, co-working with miniaturized optical instrumentation, which allows supravital examination of single embryos for the presence of apoptotic blastomers with full after lab-on-a-chip study "recovery" and maintenance of their further developmental capacity.  相似文献   

7.
A multi-analyte detection system using a unique antibody (Ab) biochip is described. The Ab-based biochip, also referred to as the protein biochip, uses a sensor array based on a complementary metal oxide silicon (CMOS) integrated circuit. The Ab-biochip has a sampling platform of four-by-four microarrays of antibodies deposited onto a Nylon membrane substrate. The micro-arrayed antibodies can be interrogated simultaneously or sequentially using the biochip sensing array detector with the use of a diffractive optical element illuminating each antibody spot individually. The usefulness of the Ab biochip is illustrated by the measurements of immunoglobulin G (IgG) used as the model analyte system. The detection limit for Cy5-labeled IgG molecules was 13 pg.  相似文献   

8.
用于细胞破裂的微流控生物芯片的研制   总被引:4,自引:0,他引:4  
陈兴  崔大付  刘长春  蔡浩原 《分析化学》2006,34(11):1656-1660
基于微电子机械系统(MEMS)技术,研制成一种夹流式血细胞破裂微流控生物芯片。细胞样品在破胞试剂夹流作用下导入芯片并在微沟道中流动,两种液体在流动过程中充分混合,导致细胞破裂。采用抗凝全血为细胞样品,比较胍盐和曲拉通的破胞效果;并分析在胍盐破裂细胞条件下,细胞浓度和流速对破胞效果的影响。控制破胞试剂流速远大于样品流速,可在几秒钟内完成细胞的破裂;保持破胞试剂与样品流速的比例,同时提高流速可在芯片上实现细胞的快速破裂。夹流式细胞破裂芯片具有与细胞分离芯片和脱氧核糖核酸(DNA)提取芯片相集成的潜力,可实现对复杂生物样品预处理操作,为实现微全分析系统打下良好基础。  相似文献   

9.
A high-throughput microfluidic poly-(dimethylsiloxane) biochip was developed to quantify bacterial adhesion to single host cells by real-time PCR assay. The biochip is simply structured with a two-dimensional array of 900 micro-wells, one inlet, and one outlet micro-channels. Isolation of single infected host cells into the individual micro-wells of the biochip was achieved by one-step vacuum-driven microfluidics. The adhered bacterial cells were then quantified by direct on-chip real-time PCR assay with single-bacterium-detection sensitivity. The performance of this microfluidic platform was demonstrated through profiling of the association of a common bacterial pathogen, Pseudomonas aeruginosa, to single host human lung epithelial A549 cells, revealing an adherence distribution that has not been previously reported. This microfluidic platform offers a simple and effective tool for biologists to analyze pathogen–host interaction at the single-cell level without the necessities of fluorescence labeling. The chip can similarly be used for other PCR-based applications requiring single-cell analysis.  相似文献   

10.
Kim DS  Lee SH  Ahn CH  Lee JY  Kwon TH 《Lab on a chip》2006,6(6):794-802
Blood typing is the most important test for both transfusion recipients and blood donors. In this paper, a low cost disposable blood typing integrated microfluidic biochip has been designed, fabricated and characterized. In the biochip, flow splitting microchannels, chaotic micromixers, reaction microchambers and detection microfilters are fully integrated. The loaded sample blood can be divided by 2 or 4 equal volumes through the flow splitting microchannel so that one can perform 2 or 4 blood agglutination tests in parallel. For the purpose of obtaining efficient reaction of agglutinogens on red blood cells (RBCs) and agglutinins in serum, we incorporated a serpentine laminating micromixer into the biochip, which combines two chaotic mixing mechanisms of splitting/recombination and chaotic advection. Relatively large area reaction microchambers were also introduced for the sake of keeping the mixture of the sample blood and serum during the reaction time before filtering. The gradually decreasing multi-step detection microfilters were designed in order to effectively filter the reacted agglutinated RBCs, which show the corresponding blood group. To achieve the cost-effectiveness of the microfluidic biochip for disposability, the biochip was realized by the microinjection moulding of COC (cyclic olefin copolymer) and thermal bonding of two injection moulded COC substrates in mass production with a total fabrication time of less than 20 min. Mould inserts of the biochip for the microinjection moulding were fabricated by SU-8 photolithography and the subsequent nickel electroplating process. Human blood groups of A, B and AB have been successfully determined with the naked eye, with 3 microl of the whole sample bloods, by means of the fabricated biochip within 3 min.  相似文献   

11.
A multifunctional integrated microfluidic biochip device was engineered to estimate the activity-toxicity and composition principle of medicine in a cell model in vitro.  相似文献   

12.
A new approach for the preparation of a biochip on porous silicon and the application of the biochip for detection of small molecule-protein interactions with desorption/ionization on porous silicon (DIOS) was demonstrated. The galvanostatically etched porous silicon substrates were chemically modified firstly to yield carboxylic acid terminated surfaces, and then the protein was covalently attached to the surface through amide bonding. By applying a solution of candidate chemicals to the surface and a subsequent wash step, the masses of captured compounds could be analyzed by DIOS. DIOS has advantages of being a direct detection tool compared to the classic fluorescence or chemiluminescence methods, because the process of labeling molecules employed in the fluorescence or chemiluminescence methods can sometimes alert the properties of the labeled molecule. The recognition between proteins and their binding partners is efficient and selective. A good tolerance to disturbance and high enrichment factor of the biochip to the analytes was observed. As an on-chip-based approach, the demonstrated method has a potential to perform in a high-throughput format.  相似文献   

13.
Abstract— The oxidation of 3, 4-dihydroxyphenylalanine (dopa) photosensitized by hematoporphyrin has been studied by ESR spectroscopy. The nitroxide free radical 2, 2, 6, 6-tetramethyl-4-piperidone-I-oxyl (TEMPONE) is shown to be a convenient probe for monitoring oxygen consumption during the reaction. Isotope and azide effects on oxygen consumption suggest that photooxidation in D2O proceeds mainly by a singler oxygen mechanism, whereas in H2O both singlet oxygen and free radical mechanisms are important. The relative importance of these mechanisms can change as oxygen is consumed during the photoreaction. TEMPONE also can be used as an indicator of the presence of reducing radicals (in this case hematoporphyrin radical anions) in the system, but only at low oxygen levels: in aerated solutions efficient reaction of these radical ions with oxygen is proposed.  相似文献   

14.
We show a novel solid state optical detection platform, integrated in a plastic biochip, based on colloidal nanocrystal FRET donors. The approach exploits a "smart" polymeric layer with both optical and biorecognition properties that allows real-time monitoring of biomolecular interactions and quantitative analyses of real-time PCR. The proposed strategy, demonstrated here for DNA detection, may open interesting perspectives for a wide range of applications, such as for proteomic studies.  相似文献   

15.
A photonic biochip with a tunable response in the visible range is suggested for blood cell sorting applications. Multi-layers of ZnS and Ge slabs (as the main building blocks), hosting a cell in which bio-sample could be injected, are considered as the core of the sensor. In order to increase the sensitivity of the chip, the bio-cell is capsulated inside air slabs, and its walls are coated with graphene sheets. Paying special attention to white and red blood components, the optimum values for structural parameters are extracted first. Tunability of the sensor detectivity is then explored by finding the role of the probe light incident angle, as well as its polarization. The strain of the graphene layer and angle in which it is applied are also suggested to further improve the performance tunability. Results reflect that the biochip can effectively identify selected components through their induced different optical features, besides of the different figure of merit and sensitivity amounts that are recorded for them by the sensor.  相似文献   

16.
The zebrafish embryo is a small, cheap, whole-animal model which may replace rodents in some areas of research. Unfortunately, zebrafish embryos are commonly cultured in microtitre plates using cell-culture protocols with static buffer replacement. Such protocols are highly invasive, consume large quantities of reagents and do not readily permit high-quality imaging. Zebrafish and rodent embryos have previously been cultured in static microfluidic drops, and zebrafish embryos have also been raised in a prototype polydimethylsiloxane setup in a Petri dish. Other than this, no animal embryo has ever been shown to undergo embryonic development in a microfluidic flow-through system. We have developed and prototyped a specialized lab-on-a-chip made from bonded layers of borosilicate glass. We find that zebrafish embryos can develop in the chip for 5 days, with continuous buffer flow at pressures of 0.005-0.04 MPa. Phenotypic effects were seen, but these were scored subjectively as 'minor'. Survival rates of 100% could be reached with buffer flows of 2 μL per well per min. High-quality imaging was possible. An acute ethanol exposure test in the chip replicated the same assay performed in microtitre plates. More than 100 embryos could be cultured in an area, excluding infrastructure, smaller than a credit card. We discuss how biochip technology, coupled with zebrafish larvae, could allow biological research to be conducted in massive, parallel experiments, at high speed and low cost.  相似文献   

17.
A new microdialysis-based glucose-sensing system with an integrated fiber-optic hybrid sensor is presented. Design and dimensions of the cell are adapted for its coupling with commercially available microdialysis techniques, thereby providing a new system for continuous glucose monitoring. The glucose level is detected via oxygen consumption which occurs as a consequence of enzymatic reaction between immobilized glucose oxidase and glucose. The use of gas-permeable Tygon tubing ensures complete and constant air-saturation of the measuring fluid in the cell. Nevertheless, a reference oxygen optode is used to detect and to compensate response changes caused by events like bacterial growth, temperature fluctuations, or failure of the peristaltic pump. In contrast to widely used electrochemical sensors, the response of the microdialysis-based fiber-optic glucose sensor is highly selective, making this sensor approach particularly advantageous for continuous glucose monitoring of patients in intensive care units. The effects of flow rate, pH, temperature, and common interferences on the sensor response are presented and discussed in detail. The sensor is evaluated in vitro using a 3-day continuous test in glucose-spiked plasma. The ability to measure glucose in humans is demonstrated by coupling the flow-through cell and commercially available microdialysis catheter CMA60. A 24-h monitoring test using this setup is successfully applied to a healthy volunteer.  相似文献   

18.
A variety of luminescent oxygen nanosensors were prepared by addressable staining of poly(styrene-block-vinylpyrrolidone) nanobeads with metal–ligand complexes whose luminescence is quenched by oxygen. They display optimal sensitivity in responding to dissolved oxygen in concentrations from 0 to 100% air saturation. The nanobeads based on cyclometallated iridium(III) complexes with coumarins are especially promising due to excellent brightnesses. The nanosensors respond virtually in real time to altering oxygen concentration and are capable of recording even very rapid changes in oxygen partial pressure. Signals are obtained by determination of luminescence lifetime in the frequency domain and in the time domain, and by ratiometric measurement of luminescence intensity. The nanosensors have been applied to sensing and imaging of dissolved oxygen, to monitor the consumption of oxygen during enzymatic oxidation of glucose, and to monitoring dissolved oxygen in a growing culture of E. coli.  相似文献   

19.
A new type of oxygen-sensitive material is obtained by preparing an aqueous emulsion of a solution of an oxygen-sensitive fluorescent dye in a rigid polymer. The fluorescence of this emulsion is related to the oxygen partial pressure, but a Stern-Volmer plot is not linear over the whole pressure range. Aside from high sensitivity and specificity for oxygen, this new type of sensing material has favorable analytical wavelengths allowing the use of low-cost opto-electronic equipment. Since the indicator is embedded in an aqueous environment, the sensor should be capable of monitoring various kinds of reactions occurring in the aqueous phase, for instance enzymatic reactions which are accompanied by production or consumption of oxygen.  相似文献   

20.
The technique of surface plasmon-coupled emission (SPCE) involves the coupling of light which is emitted from a fluorophore into the surface plasmon of an adjacent thin metal film, giving rise to highly directional emission. We have combined the advantages of SPCE with the high light collection efficiency of supercritical angle fluorescence by carrying out an immunoassay on a paraboloid array biochip in the absence of the conventional SPCE spacer layer normally used to minimize metal quenching of the fluorescence. In this work, we have successfully demonstrated an SPCE-based assay by utilizing the protein assay layer as the spacer layer. A novel 3 × 3 injection molded polymer biochip with paraboloid elements was used. The paraboloid elements served to enhance the light collection efficiency while the top surface was coated with a gold layer to use excitation of surface plasmons and detection of SPCE emission. Theoretical modeling of the gold-protein layer structure showed that the surface plasmon resonance angles were located in the detection range of the paraboloid biochip. The polarization dependence of SPCE emission was also demonstrated. Finally, a human IgG sandwich immunoassay was carried out which exhibited a limit of detection of ~10 ng/ml using 3σ. The results demonstrate the potential of the SPCE-based paraboloid array biochip as a novel platform for high-throughput analysis of biomolecular interactions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号