首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Low-protein-fouling poly(ethylene glycol) (PEG-like) plasma polymer films were prepared using radio frequency glow discharge polymerization of diethylene glycol dimethyl ether (DGpp) on top of a heptylamine plasma polymer primer layer. By varying the plasma deposition conditions, the chemistry of the DGpp film was influenced, especially in regard to the level of ether content, which in turn influenced the relative levels of bovine serum albumin and lysozyme protein fouling. Surface potential measurements indicated that these surfaces carried a net negative charge. While protein fouling remained low ( approximately 10 ng/cm2), there was a slightly higher level of the positively charged protein adsorbed on these films than the negative protein. The interaction forces measured between a silica spherical surface on both "high"- and "low"-protein-fouling DGpp films were all repulsive and short ranged (2-3 nm). There was no correlation between the surface forces measured for high- and low-protein-fouling DGpp films. Thus, it appears that enthalpic effects are very important in reducing protein adsorption. We therefore conclude that it is the concentration of residual, ethylene glycol containing species that are the crucial parameter determining protein resistance due to a combination of both entropic and enthalpic effects.  相似文献   

2.
We covalently immobilized poly(ethylene oxide) (PEO) chains onto a fluorinated ethylene propylene copolymer (FEP) surface. On the FEP surface, aldehyde groups were first deposited by plasma polymerization of acetaldehyde or acrolein. Then, amino‐PEO chains were immobilized through Schiff base formation, which was followed by reduction stabilization with sodium cyanoborohydride. The PEO‐grafted polymer surfaces thus prepared were characterized by X‐ray photoelectron spectroscopy (XPS), atomic force microscopy, contact‐angle measurements, and protein adsorption. The dramatic increase in the C O intensity of the high‐resolution XPS C 1s spectrum, together with an overall increase in oxygen content, indicated the successful attachment of PEO chains onto the acetaldehyde plasma surfaces. The amount of grafted PEO chains depended on the superfacial density of the plasma‐generated aldehyde groups. The grafted monoamino‐PEO chains formed a brushlike structure on the polymer surface, whereas the bisamino‐PEO chains predominately adopted a looplike conformation. The PEO surface had a regular morphology with greater roughness than the aldehyde surface underneath. Surface hydrophilicity increased with the grafting of PEO. Also, the bisamino‐PEO‐grafted surface had slightly higher surface hydrophilicity than its monoamino‐PEO counterpart. These PEO coatings reduced fibrinogen adsorption by 43% compared with the substrate FEP surface. © 2000 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 38: 2323–2332, 2000  相似文献   

3.
Reduction of hydrophobic interaction in water is important in biological interfaces. In our previous work, we have found that poly(styrene- b-triethylene glycol methyl ether methacrylate) (PS-PME3MA) segregates the PME3MA block to the surface in hydrophobic environment, such as in air or in a vacuum, and shows remarkable resistance against adsorption or adhesion of proteins, platelets, and cells in water. In this paper, we report that atomic force microscopy (AFM) with hydrophobic probes can directly monitor the reduced hydrophobic interaction of the PS surfaces modified by poly(styrene- b-origoethylene glycol methyl ether methacrylate) (PS-PME NMA), where N is the number of ethylene glycol units. The pull-off forces between the hydrophobic probes that are coated with octyltrichlorosilane (OLTS) and the PS-PME NMA modified polystyrene (PS) surfaces in water were measured. The absolute spring constants and tip-curvatures of the AFM cantilevers were measured to compute the work of adhesion by the Johnson, Kendall, and Roberts (JKR) theory, which relates the pull-off force at which the separation occurs between a hemisphere and a plane to the work of adhesion. The hydrophobic interactions between the hydrophobic tip and polymer surfaces in water were greatly reduced with the segregated PME NMA blocks. The hydrophobic interactions decrease with increasing N of the series of PS-PME NMA and show a correlation with the amount of protein adsorbed.  相似文献   

4.
Chemical modifications of mineral surfaces were performed in order to gain insight into what surface properties are decisive of the accumulation of dental plaque. A non-charged, hydrophilic surface was made by two consecutive plasma polymerizations, firstly with allyl alcohol, secondly with acrylic acid, followed by adsorption of a poly(ethylene glycol)-poly(ethylene imine) adduct. A strongly hydrophobic surface was obtained by plasma polymerization of hexamethyldisiloxane. Ellipsometry was used to monitor protein interaction with the surfaces. The hydrophilic surface gave very little adsorption of both a model protein, IgG, and of saliva proteins. The hydrophobic surface, on the other hand, adsorbed high amounts of both types of proteins. In vitro adhesion of an oral bacterium,S. mutans, as well as in vivo studies, gave the opposite result, the hydrophobic surface giving less adhesion and less plaque accumulation than the hydrophilic surface. A tentative explanation of this behavior is that the saliva proteins that bind to the hydrophobic surface adsorb in an unnatural conformation which does not favor bacteria adherence.  相似文献   

5.
To control protein adsorption on surfaces, low-fouling polymer coatings such as poly(ethylene oxide) (PEG or PEO) and polysaccharides are used. Their ability to resist protein adsorption is related to the layer structure, hence the immobilization mode. A polymer array technology was developed to study the structural diversity of carboxymethyl dextran (CMD) layers, whose immobilization conditions were varied. CMD arrays were analyzed by X-ray photoelectron spectroscopy (XPS) and by atomic force microscopy (AFM) colloidal probe force measurements. Serum protein adsorption was studied directly on the CMD arrays using surface plasmon resonance (SPR) microscopy. Physicochemical characterization revealed that pinning density regulates surface coverage and the amount of adsorbed molecules, and that salt concentration influences the surface structure of the charged polymer, forming extended or short layers. Protein adsorption experiments from serum showed that repulsive CMD layers are dense, with extended flexible chains. The present study underlines the usefulness of polymer arrays to study structural diversity of thin graft layers and to relate their physicochemical properties to their resistance to nonspecific protein adsorption.  相似文献   

6.
Reduction of the interfacial friction for the contact of a silicon oxide surface with sodium borosilicate in aqueous solutions has been accomplished through the adsorption of poly(L-lysine)-graft-poly(ethylene glycol) on one or both surfaces. Spontaneous polymer adsorption has been achieved via the electrostatic attraction of the cationic polylysine polymer backbone and a net negative surface charge, present for a specific range of solution pH values. Interfacial friction has been measured in aqueous solution, in the absence of wear, and on a microscopic scale with atomic force microscopy. The successful investigation of the polymer-coated interfaces has been aided by the use of sodium borosilicate microspheres (5.1 microm diameter) as the contacting probe tip. Measurements of interfacial friction as a function of applied load reveal a significant reduction in friction upon the adsorption of the polymer, as well as sensitivity to the coated nature of the interface (single-sided versus two-sided) and the composition of the adsorbed polymer. These measurements demonstrate the fundamental opportunity for lubrication in aqueous environments through the selective adsorption of polymer coatings.  相似文献   

7.
Oligo(ethylene glycol)-terminated thin films were prepared by photo-induced hydrosilylation of alpha-hepta-(ethylene glycol) methyl omega-undecenyl ether (EG(7)) on hydrogen-terminated silicon (111) and (100) surfaces. Their resistance to protein adsorption, and stabilities (from hours to days) under a wide variety of conditions, such as air, water, biological buffer, acid, and base, were investigated using contact-angle goniometry and ellipsometry techniques. Results indicated higher stability of the films chemisorbed on Si(111) than on Si(100). Furthermore, micron-sized patterns were fabricated on the films via AFM anodization lithography. Using atomic force microscopy (AFM) and fluorescence microscopy, we demonstrated that various proteins including fibrinogen, avidin, and bovine serum albumin (BSA) predominately adsorbed onto the patterns, but not the rest of the film surfaces.  相似文献   

8.
Plasma-deposited PEG-like films are emerging as promising materials for preventing protein and bacterial attachment to surfaces. To date, there has not been a detailed surface analysis to examine the chemistry and molecular structure of these films as a function of both precursor size and structure. In this paper, we describe radio-frequency plasma deposition of a series of short-chain oligoglymes, dioxane, and crown ethers onto glass cover slips to create poly(ethylene glycol)-like coatings. The resultant films were characterized by X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (TOF-SIMS), dynamic contact angle goniometry, and radiolabeled fibrinogen adsorption. Detailed analysis of the high-mass (120-300 m/z) TOF-SIMS oligoglyme film spectra revealed six classes of significant fragments. Two new models are proposed to describe how these fragments could be formed by distinct film-building processes: incorporation of intact and fragmented precursor molecules. The models also provide for the incorporation of hydrocarbon--a species that is not present in the precursors but is evidenced in XPS C(1s) spectra of these films. Two additional models describe the effects of incorporating intact and fragmented cyclic precursors.  相似文献   

9.
An ideal nonbiofouling surface for biomedical applications requires both high-efficient antifouling characteristics in relation to biological components and long-term material stability from biological systems. In this study we demonstrate the performance and stability of an antifouling surface with grafted zwitterionic sulfobetaine methacrylate (SBMA). The SBMA was grafted from a bromide-covered gold surface via surface-initiated atom transfer radical polymerization to form well-packed polymer brushes. Plasma protein adsorption on poly(sulfobetaine methacrylate) (polySBMA) grafted surfaces was measured with a surface plasmon resonance sensor. It is revealed that an excellent stable nonbiofouling surface with grafted polySBMA can be performed with a cycling test of the adsorption of three model proteins in a wide range of various salt types, buffer compositions, solution pH levels, and temperatures. This work also demonstrates the adsorption of plasma proteins and the adhesion of platelets from human blood plasma on the polySBMA grafted surface. It was found that the polySBMA grafted surface effectively reduces the plasma protein adsorption from platelet-poor plasma solution to a level superior to that of adsorption on a surface terminated with tetra(ethylene glycol). The adhesion and activation of platelets from platelet-rich plasma solution were not observed on the polySBMA grafted surface. This work further concludes that a surface with good hemocompatibility can be achieved by the well-packed surface-grafted polySBMA brushes.  相似文献   

10.
The nitroxide-mediated polymerization of styrenic monomers containing oligo(ethylene glycol) (OEGn) moieties was chosen for the preparation of biocompatible polymer brushes tethered to silicon oxide surfaces due to the broad range of monomer structures available and the use of a nonmetallic initiator. These surfaces were characterized by near-edge X-ray absorption fine structure and water contact angle measurements. The biocompatibility of these grown polymer brushes was studied and compared with deposited assemblies of surface-bound OEGn-terminated silanes with selected chain lengths. Grown polymer brushes with short OEGn side chains suppressed protein adsorption significantly more than the deposited assemblies of short OEGn chains, and this was attributed to higher surface coverage by the brushes. Cell adhesion studies confirmed that OEGn-containing polymer brushes are particularly effective in preventing nonspecific adhesion. Studies of protein adsorption and cell localization carried out with specific ligands on surfaces patterned demonstrated the potential of these surface-tethered polymer brushes for the formation of micro- and nanoscale devices.  相似文献   

11.
The hemocompatibility of polymeric vascular implants is in part dependent on the propensity of fibrinogen to adsorb to the implant surface. Fibrinogen surface adsorption was measured in real time using a quartz crystal microbalance with dissipation monitoring (QCM-D). Six new, biodegradable tyrosine-derived polycarbonates were used as test surfaces. Stainless steel, poly(L-lactic acid), poly(D,L-lactide-co-glycolide), and poly(ethylene terephthalate) surfaces served as controls and provided a comparison of the test surfaces with those of commonly used biomaterials. Our study addressed the question regarding to which extent systematic variations in polymer structure can be used to optimize X-ray visibility and provide tunable degradation rates while generating protein-repellant surface properties that minimize fibrinogen adsorption. QCM-D revealed surface-dependent changes in fibrinogen layer thickness (2 to 37 nm), adsorbed wet mass (0.2 to 4.3 microg/cm2), and viscosity (0.001 to 0.005 kg/ms). While we did not find an overall correlation between surface air-water contact angle measurements and fibrinogen adsorption (R2 = 0.08), our data demonstrate that gradually increasing the poly(ethylene glycol) content within a subgroup of polymers having the same polymer backbone will lead to decreased fibrinogen adsorption. Within this subgroup of polymers, there was a strong correlation between decreasing air-water contact angles and decreasing fibrinogen adsorption (R2 = 0.95). We conclude that it is possible to minimize fibrinogen adsorption to tyrosine-derived polycarbonates while optimizing X-ray visibility and degradation rates. Some of the tyrosine-derived polycarbonates were identified as useful materials for the design of blood-contacting implants on the basis of their substantially lower levels of fibrinogen adsorption relative to the commonly used controls.  相似文献   

12.
Polyurethanes were modified using monobenzyloxy polyethylene glycol (BPEG) which possesses a bulky hydrophobic benzyloxy group at one end and a hydroxyl group at the other end as a preconstructed BPEG layer, and poly(ethylene glycol) (PEG) and monomethoxyl poly(ethylene glycol) (MPEG) with various chain lengths as fillers. Our objective was to investigate the effect of PEG graft density and conformation on protein adsorption at PEGlated surface. The graft density was estimated by a chemical titration method. The combination of ATR-FTIR, AFM and titration results provide evidences that the graft density can be increased by backfilling PEG or MPEG to a BPEG layer. However, fibrinogen and albumin adsorption significantly increased on all surfaces after PEG or MPEG backfilling. We conclude that the conformation of hydrophobic benzyloxy end groups of the BPEG layer plays a key role. The benzyloxy end groups of preconstructed PEG chains stretch to the surface after PEG backfilling, which possibly accounts for the observed increase in protein adsorption. The BPEG conformation change after backfilling with PEG or MPEG was also suggested by contact angles. Additionally, protein adsorption was slightly influenced by the length of filler, suggesting a change in surface morphology.  相似文献   

13.
Forces have been measured between silica surfaces with adsorbed surfactants by means of a bimorph surface force apparatus. The surfactants used are the cationic surfactant tetradecyltrimethylammonium bromide (TTAB) and the nonionic surfactant hexakis(ethylene glycol) mono-n-tetradecyl ether (C(14)E(6)) as well as mixtures of these two surfactants. The measurements were made at elevated pH, and the effect of salt was studied. At high pH the glass surface is highly charged, which increases the adsorption of TTAB. Despite the low adsorption generally seen for nonionic surfactants on silica at high pH, addition of C(14)E(6) has a considerable effect on the surface forces between two glass surfaces in a TTAB solution. The barrier force is hardly affected, but the adhesion is reduced remarkably. Also, addition of salt decreases the adhesion, but increases the barrier force. In the presence of salt, addition of C(14)E(6) also increases the thickness of the adsorbed layer. The force barrier height is also shown to be related to literature values for surface pressure data in these systems.  相似文献   

14.
The adsorption of ions and amphiphilic molecules on solid polymers is investigated by direct force measurements using an atomic force microscope (AFM). It is shown that electrolyte ions are changing the surface potentials of the solid polymers as well as their adhesive properties. The experiments show that the interaction with a negatively charged probe is dramatically decreased by the adsorption of anions. The adsorption isotherms are determined by zeta potential measurements (streaming potential of flat plates). In presence of adsorbing anions, the attractive interaction and the adhesion are reduced and can be eliminated completely. So, even solutions of simple electrolyte ions can be applied intentionally in order to modify the interaction of polymer surfaces. A wide variety of technological applications becomes accessible.  相似文献   

15.
In general, it is a challenge to control the highly polar material grafting from the chemically inert Teflon-based membrane surface. This work describes the surface modification and characterization of expanded poly(tetrafluoroethylene) (ePTFE) membranes grafted with poly(ethylene glycol) methacrylate (PEGMA) macromonomer via surface-activated plasma treatment and thermally induced graft copolymerization. The chemical composition and microstructure of the surface-modified ePTFE membranes were characterized by Fourier transform infrared spectroscopy (FT-IR), contact angle, and bio-atomic force microscopy (bio-AFM) measurements. Biofouling property of the modified membranes was evaluated by the measurements of the plasma protein (γ-globulin, fibrinogen, or albumin) adsorption determined using an enzyme-linked immunosorbent assay (ELISA). In general, the hydrophilicity of the surface of ePTFE membranes increases with increasing the grafting degree of the copolymerized PEGMA. The highly hydrated PEGMA chain on the resulting ePTFE membranes was found to form a surface hydrogel-like layer with regulated coverage in aqueous state, which can be controlled by the content of PEGMA macromonomer in the reaction solution. The relative protein adsorption was effectively reduced with increasing capacity of the hydration for the PEGMA chain grafted on the ePTFE membrane surface. From both results of protein adsorption and platelet adhesion test in vitro, it is concluded that the PEGMA-grafted hydrophilic ePTFE membranes could provide good biofouling resistance to substantially reduce plasma protein and blood platelet fouling on the membrane surface in human body temperature.  相似文献   

16.
Zou  X. P.  Kang  E. T.  Neoh  K. G. 《Plasmas and Polymers》2002,7(2):151-170
Argon plasma-induced graft polymerization of a solution-coated macromonomer, poly(ethylene glycol) methyl ether methacrylate (PEGMA), on the Si(100) surface was carried out to impart anti-fouling properties to the Si(100) surface. The surface composition and microstructure of the PEGMA graft-polymerized Si(100) surfaces were characterized by X-ray photoelectron spectroscopy (XPS), Fourier-transform infrared spectroscopy (FTIR), and atomic force microscopy (AFM) measurements. The extent of crosslinking in the plasma-graft polymerized PEGMA (pp-PEGMA) was estimated by gel fraction determination. In general, an appropriate RF power of about 15 W and a PEGMA macromonomer concentration of about 1 wt% in the coating solution for plasma polymerization produced a high graft yield of pp-PEGMA on the Si(100) surface (the pp-PEGMA-g-Si surface). The Si(100) surface with a high concentration of the grafted pp-PEGMA was effective in preventing bovine serum albumin (BSA) adsorption and platelet adhesion.  相似文献   

17.
PEGylated Nb2O5 surfaces were obtained by the adsorption of poly(L-lysine)-g-poly(ethylene glycol) (PLL-g-PEG) copolymers, allowing control of the PEG surface density, as well as the surface charge. PEG (MW 2 kDa) surface densities between 0 and 0.5 nm(-2) were obtained by changing the PEG to lysine-mer ratio in the PLL-g-PEG polymer, resulting in net positive, negative and neutral surfaces. Colloid probe atomic force microscopy (AFM) was used to characterize the interfacial forces associated with the different surfaces. The AFM force analysis revealed interplay between electrical double layer and steric interactions, thus providing information on the surface charge and on the PEG layer thickness as a function of copolymer architecture. Adsorption of the model proteins lysozyme, alpha-lactalbumin, and myoglobin onto the various PEGylated surfaces was performed to investigate the effect of protein charge. In addition, adsorption experiments were performed over a range of ionic strengths, to study the role of electrostatic forces between surface charges and proteins acting through the PEG layer. The adsorbed mass of protein, measured by optical waveguide lightmode spectroscopy (OWLS), was shown to depend on a combination of surface charge, protein charge, PEG thickness, and grafting density. At high grafting density and high ionic strength, the steric barrier properties of PEG determine the net interfacial force. At low ionic strength, however, the electrical double layer thickness exceeds the thickness of the PEG layer, and surface charges "shining through" the PEG layer contribute to protein interactions with PLL-g-PEG coated surfaces. The combination of AFM surface force measurements and protein adsorption experiments provides insights into the interfacial forces associated with various PEGylated surfaces and the mechanisms of protein resistance.  相似文献   

18.
The nonspecific interaction of proteins with surfaces in contact with biofluids leads to adverse problems and is prevented by a biocompatible surface coating. The current benchmark material among such coatings is poly(ethylene glycol) (PEG). Herein, we report on the synthesis of linear polyglycerol derivatives as promising alternatives to PEG. Therefore, gold surfaces as a model system are functionalized with a self‐assembled monolayer (SAM) by a two‐step anhydride coupling and a direct thiol immobilization of linear poly(methyl glycerol) and polyglycerol. Surface plasmon resonance (SPR) spectroscopy reveals both types of functionalized surfaces to be as resistant as PEG towards the adsorption of the test proteins fibrinogen, pepsin, albumin, and lysozyme. Moreover, linear polyglycerols adsorb even less proteins from human plasma than a PEG‐modified surface. Additional cell adhesion experiments on linear poly(methyl glycerol) and polyglycerol‐modified surfaces show comparable cell resistance as for a PEG‐modified surface. Also, in the case of long‐term stability, high cell resistance is observed for all samples in medium. Additional in vitro cell‐toxicity tests add to the argument that linear poly(methyl glycerol) and polyglycerol are strong candidates for promising alternatives to PEG, which can easily be modified for biocompatible functionalization of other surfaces.  相似文献   

19.
The pulsed plasma polymerization of low molecular weight molecules containing only one (ethylene oxide vinyl ether) and two (diethylene oxide vinyl ether) ethylene oxide units were investigated. The surface density of EO units retained in the polymer films increases sharply with decreasing average power input during deposition, particularly at very low plasma duty cycles. The protein adsorption properties of these plasma synthesized polymer were investigated using 125I-labeled albumin and fibrinogen. Surprisingly effective, non-fouling surfaces were observed with films synthesized from the monomer containing two ethylene oxide units; however, the monomer containing only one EO unit gave surfaces that were not particularly effective in preventing protein adsorptions. The results obtained show that ultra short chain length PEO modified surfaces can be biologically non-fouling. This, in turn, has interesting consequences in terms of trying to identify the basic reason for the effectiveness of EO units in preventing biomolecule adsorptions on surfaces.  相似文献   

20.
A commercial nonbinding surface effectively prevents protein adsorption; however, the platelet phenotype on this surface has yet to be defined. This study evaluates platelet adhesion and adsorption of several plasma/extracellular matrix (ECM) proteins to the nonbinding surface compared to other commonly used nontreated and high-binding surfaces. Platelet adhesion to uncoated microplates and those coated with fibrinogen or collagen is quantified by colorimetric assay. The binding capacity of the examined surfaces for plasma/ECM proteins is evaluated by measuring the relative and absolute protein adsorption. Compared to other surfaces, the nonbinding surface effectively prevents platelet adsorption, i.e. by 61-93% (Enzyme-Linked Immunosorbent Assay, ELISA), and reduces platelet adhesion, i.e. by 92%, when not coated with any protein. The nonbinding surface also decreases platelet deposition on collagen (up to 31%), but not fibrinogen. The nonbinding surface seems to be more of a low-fouling than nonfouling material, as it is able to reduce fibrinogen adsorption but not prevent platelet adhesion to fibrinogen. This feature should be considered when using the nonbinding surface for in vitro platelet testing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号