1.
A liquid chromatographic–electrospray ionization–time‐of‐flight/mass spectrometric (LC‐ESI‐TOF/MS) method was developed and applied for the determination of WKYMVm peptide in rat plasma to support preclinical pharmacokinetics studies. The method consisted of micro‐elution solid‐phase extraction (SPE) for sample preparation and LC‐ESI‐TOF/MS in the positive ion mode for analysis. Phenanthroline (10 mg/mL) was added to rat blood immediately for plasma preparation followed by addition of trace amount of 2 m hydrogen chloride to plasma before SPE for stability of WKYMVm peptide. Then sample preparation using micro‐elution SPE was performed with verapamil as an internal standard. A quadratic regression (weighted 1/concentration2), with the equation y = ax2 + bx + c was used to fit calibration curves over the concentration range of 3.02–2200 ng/mL for WKYMVm peptide. The quantification run met the acceptance criteria of ±25% accuracy and precision values. For quality control samples at 15, 165 and 1820 ng/mL from the quantification experiment, the within‐run and the between‐run accuracy ranged from 92.5 to 123.4% with precision values ≤15.1% for WKYMVm peptide from the nominal values. This novel LC‐ESI‐TOF/MS method was successfully applied to evaluate the pharmacokinetics of WKYMVm peptide in rat plasma.  相似文献   

2.
Metformin is a well‐known oral antihyperglycemic drug used in treatment of type II diabetes. Analysis of metformin in biological fluids is a challenge owing to its high polarity and small molecular size, which lead to poor retention of metformin on reversed‐phase liquid chromatographic columns. A high‐throughput method was developed and validated for the determination of metformin in rat plasma in support of preclinical toxicology studies, using hydrophilic interaction liquid chromatography tandem mass spectrometry (HILIC‐MS/MS) and Tecan automated sample preparation. Extracted samples were directly injected onto the unbounded silica column with an aqueous–organic mobile phase. This HILIC‐MS/MS method was validated for accuracy, precision, sensitivity, stability, matrix effect, recovery and calibration range. Acceptable intra‐run and inter‐run assay precision (coefficient of variation ≤ 3.9%) and accuracy (99.0–101.8%) were achieved over a linear range of 50–50,000 ng/mL. Metformin is stable in rat plasma for at least 6 h at room temperature, 147 days at ?70°C and through three freeze (?70°C) and thaw cycles. Metformin is also stable in rat whole blood for at least 2 h at room temperature and in an ice–water bath. The validated method was successfully used in support of several preclinical studies where metformin is dosed together with an investigational drug substance. The ruggedness of the validated method was demonstrated by the incurred sample reproducibility test. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
A technique using a fully automated on-line solid phase extraction (SPE) system (Symbiosis, Spark Holland) combined with liquid chromatography (LC)-mass spectrometry (MS/MS) has been investigated for fast bioanalytical method development, method validation and sample analysis using both conventional C18 and monolithic columns. Online SPE LC-MS/MS methods were developed in the automated mode for the quantification of model compounds (propranolol and diclofenac) directly in rat plasma. Accuracy and precision using online SPE LC-MS/MS with conventional C18 and monolithic columns were in the range of 88-111% and 0.5-14%, respectively. Total analysis cycle time of 4 min per sample was demonstrated using the C18 column. Monolithic column allowed for 2 min total cycle time without compromising the quality and validation criteria of the method. Direct plasma sample injection without on-line SPE resulted in poor accuracy and precision in the range of 41-108% and 3-81%. Furthermore, the increase in back pressure resulted in column damage after the injection of only 60 samples.  相似文献   

4.
A rapid and highly specific assay was developed and validated for the estimation of ZYDPLA1 in rat plasma using liquid chromatography coupled to tandem mass spectrometry with positive electrospray ionization. Method validation comprised of parameters such as specificity, matrix effect, precision, accuracy, recovery, stability, etc. The assay procedure involved a simple protein precipitation of ZYDPLA1 and alprazolam (internal standard) from rat plasma using acetonitrile. Chromatographic separation was achieved with a gradient mobile phase comprising: (A) 0.2% ammonia in purified water; (B) 0.1% formic acid in isopropyl alcohol/methanol (1: 1 v /v); and (C) acetonitrile at a flow rate of 1 mL/min on an ACE‐5, C18 (4.6 × 50 mm) column with a run time of 5.5 min. The quantitation of ZYDPLA1 was achieved by the summation of four multiple reaction mode transitions (m/z 399.7 → 383.0, 399.7 → 276.10, 399.7 → 153.20 and 399.7 → 127.20), while that of the internal standard was by a single multiple reaction mode transition (m/z 309.10 → 281.00). The lower limit of quantitation achieved was 0.01 μg/mL and the method showed linearity from 0.01 to 25 μg/mL. The intra‐ and inter‐day precision (%CV) of the quality control samples was within 8.81% and accuracy was ±10% of nominal values. This novel method was applied for evaluation of toxicokinetics of ZYDLA1 in rats.  相似文献   

5.
An liquid chromatography–quadrupole time‐of‐flight (QqTOF) mass spectrometric method was developed for the determination of humanized or human monoclonal antibodies in rat plasma at the early drug discovery stage. Trastuzumab was used as a model monoclonal antibody. The method consisted of immunoprecipitation followed by tryptic digestion for sample preparation and LC‐TOF‐MS/MS analysis of specific signature peptides in the positive ion mode using electrospray ionization for analysis. A stable isotope‐labeled signature peptide was also used as internal standard. A quadratic regression (weighted 1/concentration2), with an equation y = ax2 + bx + c, was used to fit calibration curves over the concentration range of 0.500–100 µg/mL for trastuzumab. Samples from a pharmacokinetic study in rat were analyzed by this qualified LC‐TOF‐MS/MS method and concentrations were compared with those generated by enzyme linked immunosorbent assays method. The LC‐TOF‐MS/MS method was accurate and precise, with quantitative results comparable with those of ELISA. The qualification run met the acceptance criteria of ±25% accuracy and precision values for quality control samples. Within‐run accuracy ranged from 1.53 to 9.20% with precision values ≤10.29%. This LC‐TOF‐MS/MS method approach could be used as a complementary method for humanized or human monoclonal antibodies at the early drug discovery stage. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
In this study, we report the development and validation of an LC–tandem mass spectrometry method for the simultaneous quantitation of bendamustine and copanlisib in mouse plasma as per the US FDA regulatory guidelines. The sample processing involves extraction of bendamustine and copanlisib along with internal standard (IS; warfarin) from 50 μL mouse plasma using a liquid–liquid extraction method. The chromatographic separation of bendamustine, copanlisib and the IS was achieved on an Atlantis dC18 column using an isocratic mobile phase (5 mM ammonium acetate:methanol, 20:80 v/v). Bendamustine, copanlisib and the IS eluted at 0.88, 1.39 and 0.74 min, respectively, with a total run time of 2.5 min. The calibration curve ranged from 3.99–2996 and 4.33–3248 ng/mL for bendamustine and copanlisib, respectively. Inter- and intra-day precision and accuracy, stability in processed samples and upon storage, dilution integrity and incurred sample reanalysis were investigated for both the analytes. The intra- and inter-day precisions were in the ranges of 2.01%–5.05% and 2.74%–6.13% and 1.98%–7.64 and 8.62%–9.04% for bendamustine and copanlisib, respectively. Stability studies showed that both analytes were stable on bench top for 6 h, in auto-sampler for 24 and at −80°C for 30 days. The validated method was successfully applied to a pharmacokinetic study in mice.  相似文献   

7.
A liquid chromatography–triple quadrupole mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of 5‐nitro‐5′‐hydroxy‐indirubin‐3′‐oxime (AGM‐130) in human plasma to support a microdose clinical trial. The method consisted of a liquid–liquid extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d3‐AGM‐130 was used as the internal standard. A linear regression (weighted 1/concentration) was used to fit calibration curves over the concentration range of 10–2000 pg/mL for AGM‐130. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 96.6% with a precision (coefficient of variation, CV) of 4.4%. For quality control samples at 30, 160 and 1600 pg/mL, the between run CV was ≤5.0 %. Between‐run accuracy ranged from 98.1 to 101.0%. AGM‐130 was stable in 50% acetonitrile for 168 h at 4°C and 6 h at room temperature. AGM‐130 was also stable in human plasma at room temperature for 6 h and through three freeze–thaw cycles. The variability of selected samples for the incurred sample reanalysis was ≤12.7% when compared with the original sample concentrations. This validated LC‐MS/MS method for determination of AGM‐130 was used to support a phase 0 microdose clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
A novel, sensitive and selective ultra‐high‐performance liquid chromatography–electrospray ionization mass spectrometry method was developed and validated for the quantification of acotiamide (ACT), a first‐in‐class drug used in functional dyspepsia, in rat plasma. A simple protein precipitation method with acetonitrile as precipitating solvent was used to extract ACT from rat plasma. ACT and an internal standard (mirabegron, IS) were separated on an Agilent poroshell EC C18 column (50 × 3.0 mm, 2.7 µm) using methanol–10 mM ammonium acetate binary gradient mobile phase at a flow rate of 0.4 mL/min over 4 min run time. Detection was performed using target ions of [M + H]+ at m/z 451.2010 for ACT and m/z 397.1693 for IS in selective ion mode. The method was validated in the calibration range of 1.31–1000 ng/mL. All the validation parameters were well within the limits. The method demonstrated good performances in terms of intra‐ and inter‐day precision (3.27–12.60% CV) and accuracy (87.96–104.94%). Thus the present ultra‐high‐pressure liquid chromatograhy–high‐resolution mass spectrometry method for determination of ACT in rat plasma, is highly sensitive and rapid with a short run‐time of 4 min, can be suitable for high sample throughput and for large batches of biological samples in pharmacokinetic studies. This method can be extended to measure plasma concentrations of ACT in humans to understand drug metabolism, drug interaction and adverse effects. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
The aim of the present investigation is to develop a simple, fast, and sensitive method for the determination of a new candidate drug, AZD3409, in rat, dog, and human plasma samples. AZD3409 is stable in aqueous solutions at low pH (< 4) but not in whole blood or in plasma. In rat plasma at 25 degrees C, more than 90% of the compound is degraded within 40 min. When 20 mg of NaF and 50 microL of protease inhibitor cocktail are added to 1.0 mL of rat blood, AZD3409 is stable for up to about 90 min. Due to the instability of AZD3409, microextraction in packed syringe (MEPS) is used as an online and fast sample-preparation method, followed by liquid chromatography-tandem mass spectrometry (LC-MS-MS) for the quantitation of this compound in plasma samples. In MEPS, the sampling sorbent is 1 mg of polystyrene polymer packed in a 250-microL syringe. When the plasma sample (50-250 microL) is withdrawn through the syringe by an autosampler, the analyte is adsorbed to the solid phase. The analyte is then eluted with an organic solvent such as methanol or the LC mobile phase (20-50 microL) directly into the instrument's injector. MEPS is rapid and easy to use. The lower limit of quantitation for AZD3409 is established to be 0.024 microM. The accuracy of the quality-control samples ranged from 89% to 102%, and the precision (C.V.%) had a value of 11-16% for the plasma samples. The calibration curve in plasma is obtained in the concentration range 0.022-9.0 microM. The coefficients of determination (R2) for plasma samples were > or = 0.998 for all runs. The present method is used for the analysis of rat and dog plasma samples.  相似文献   

10.
Isoginkgetin is a biflavonoid compound isolated from the leaf extracts of Ginkgo biloba. In this study, an liquid chromatography–tandem mass spectrometry (LC/MS/MS) with liquid–liquid extraction was developed and validated for the analysis of isoginkgetin in rat plasma. In the process of chromatographic separation, selected reaction monitoring transitions for isoginkgetin and IS were m/z 566.8 → 134.7 and m/z 430.8 → 269.3, respectively. The validation parameters including selectivity, linearity, LLOQ, accuracy, precision, matrix effect, stability and recovery were satisfactory. The intra‐ and inter‐batch precision (RSD) were <12.1% in plasma, while the accuracy (RE) was within ±14.3%. This method was employed in a pharmacokinetic study on rats after the intravenous administration of isoginkgetin.  相似文献   

11.
A liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry method was developed and validated to investigate the pharmacokinetic properties of β‐sitosterol, campesterol, and stigmasterol in rat plasma. Cholesterol‐d6 was used as an internal standard. To avoid interference of the three phytosterols in rat plasma and minimize matrix effects, a small volume (10 μL) of 4% bovine serum albumin was used as a surrogate matrix for making calibrators and quality control samples. Rat plasma (10 μL) samples were extracted by liquid–liquid extraction with methyl tert‐butyl ether and separated on a Kinetex C18 column. The detection was performed on a triple quadrupole tandem mass spectrometer in selected reaction monitoring mode using positive atmospheric pressure chemical ionization. This assay was linear over concentration ranges of 250–5000 ng/mL (β‐sitosterol), 250–5000 ng/mL (campesterol), and 50–2000 ng/mL (stigmasterol). Additionally, a second set of quality controls made in rat plasma was also evaluated against calibration curves made using the surrogate matrix. All the validation data, including the specificity, precision, accuracy, recovery, matrix effect, stability, and incurred sample reanalysis conformed to the acceptance requirements. Our method was successfully applied to study the pharmacokinetics of three phytosterols in rats.  相似文献   

12.
Buparlisib is a selective phosphoinositide 3 kinase inhibitor currently evaluated in clinical trials. We developed and validated an LC–MS/MS coupled with a one-step protein precipitation extraction method for the quantitation of buparlisib in rat plasma. After protein precipitation with acetonitrile, the plasma sample was analyzed using a Cortecs UPLC C18 column, with acetonitrile–0.1% formic acid as the mobile phase system. Mass spectrometric detection was conducted in positive ionization mode, with target quantitative ion pair of m/z 411.2 → 367.2 for buparlisib. The calibration curve showed good linearity (1.0–3000 ng/ml), with acceptable accuracy (RE ranging from −6.2 to 5.9%) and precision (RSD within 8.2%) values at quality control concentrations. Extraction recovery from plasma was 80.9–88.7% and the matrix effect was negligible (92.6–95.2%). The validated method presented a simple quantification method of buparlisib in detail and utilized it for a pharmacokinetic study at three dose concentrations after oral administration in Wistar rats.  相似文献   

13.
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography–tandem mass spectrometry (LC‐MS/MS) was developed. This assay represents the first LC‐MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3‐atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/mL and 10 nm for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3–900 ng/mL and 10 nm to 10 µm for human plasma and cellular samples, respectively (r2 > 0.999). The intra‐ and inter‐day assay accuracy and precision were evaluated using quality control samples at three different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect and recovery were also successfully demonstrated. The present assay is superior to previously published LC‐MS and LC‐MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
A simple, rapid and high sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method for the determination of neostigmine in small‐volume beagle dog plasma was developed to assess the plasma pharmacokinetics of neostigmine. After protein precipitation in a Sirocco 96‐well filtration plate, the filtrate was directly injected into the LC‐MS/MS system. The analytes were separated on a Hanbon Hedera CN column (100 × 4.6 mm, 5 µm) with a mobile phase composed of methanol–water (60:40, v/v) and the water containing 0.01% formic acid at a flow rate of 0.6mL/min, with a split ratio of 1:1 flowing 300 μL into the mass spectrometer. The run time was 3 min. Detection was accomplished by electrospray ionization source in multiple reactions monitoring mode with the precursor‐to‐product ion transitions m/z 223.0 → 72.0 and 306.0 → 140.0 for neostigmine and anisodamine (internal standard), respectively. The method was sensitive with a lower limit of quantitation of 0.1 ng/mL, and good linearity in the range 0.1–100ng/mL for neostigmine (r ≥ 0.998). All the validation data, such as accuracy, intra‐run and inter‐run precision, were within the required limits. The method was successfully applied to pharmacokinetic study of neostigmine methylsulfate injection in beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
A method based on ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) in combination with solid‐phase extraction for sample pretreatment has been developed for the simultaneous analysis of amitriptyline and its main metabolite in human plasma. The extraction of the analytes from plasma samples was carried out by means of a selective SPE procedure using hydrophilic–lipophilic balance cartridges. The assay involves a simple solid‐phase extraction (SPE) procedure of 0.2 mL of human plasma and analysis was performed on a triple‐quadrupole tandem mass spectrometer by multiple reactions monitoring (MRM) mode via electrospray ionization (ESI). The standard calibration curve was linear over the ranges 0.370–95.539 ng/mL for amitriptyline and 0.365–94.374 ng/mL for nortriptyline, expressed by the linear correlation coefficient r2, which was better than 0.995 for both. The intra‐ and inter‐day precision and accuracy of the quality control samples were within 10.0%. The recovery was 85.3, 88.4 and 80.7% for amitriptyline, nortriptyline and doxepin respectively. Total run time was 1.2 min only for each sample, which makes it possible to analyze more than 400 samples per day. The method was highly reproducible and gave peaks with excellent chromatography properties. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
A simple, rapid, high‐throughput, and highly sensitive LC–MS/MS was developed to determine anisodamine in a small volume (50 μL) of beagle dog plasma using atropine sulfate as the internal standard. The analyte and internal standard were isolated from 50 μL plasma samples after a one‐step protein precipitation using Sirocco 96‐well protein precipitation filtration plates. The separation was accomplished on a Hanbon Hedera CN column (100 × 4.6 mm, 5 μm) and the run time was 4 min. A Micromass Quatro Ultima mass spectrometer equipped with an ESI source was operated in the multiple reaction monitoring mode with the precursor‐to‐product ion transitions m/z 306.0→140.0 (anisodamine) and 290.0→123.9 (atropine) used for quantitation. The method was sensitive with a low LOQ of 0.05 ng/mL, and good linearity in the range 0.05–50 ng/mL for anisodamine (r2 ≥ 0.995). All the validation data, such as accuracy, intra‐ and interrun precision, were within the required limits. The method was successfully applied to the pharmacokinetic study of anisodamine hydrochloride injection in beagle dogs.  相似文献   

17.
A simple, rapid and sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC‐ESI‐MS/MS) assay method is proposed for the determination of tolvaptan in human plasma samples using tolvaptan d7 as internal standard (IS). Analyte and the IS were extracted from 100 μL of human plasma via simple liquid–liquid extraction. The chromatographic separation was achieved on a C18 column using a mixture of methanol and 0.1% formic acid buffer (80:20, v/v) as the mobile phase at a flow rate of 1.0 mL/min. The calibration curve obtained was linear (r2 ≥ 0.99) over the concentration range of 0.05–501 ng/mL. Method validation was performed as per US Food and Drug Administration guidelines and the results met the acceptance criteria. The intra‐day and inter‐day precision (coefficient of variation) and accuracy results in three validation batches across five concentration levels were well within the acceptance limits. A run time of 2.0 min for each sample made it possible to analyze more samples in a short time, thus increasing the productivity. The proposed method was successfully applied to a pharmacokinetic study of 15 mg and 60 mg tolvaptan tablet formulation in healthy South Indian male subjects under fasting condition. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
A novel and sensitive LC–MS/MS method was developed and validated for determination of sofosbuvir (SF) using eplerenone as an internal standard. The Xevo TQD LC–MS/MS was operated under the multiple‐reaction monitoring mode using electrospray ionization. Extraction with tert‐butyl methyl ether was used in sample preparation. The prepared samples were chromatographed on Acquity UPLC BEH C18 (50 × 2.1 mm, 1.7 μm) column by pumping 0.1% formic acid and acetonitrile in an isocratic mode at a flow rate of 0.35 mL/min. Method validation was performed as per the US Food and Drug Administration guidelines and the standard curves were found to be linear in the range of 0.25–3500 ng/mL for SF. The intra‐ and inter‐day precision and accuracy results were within the acceptable limits. A very short run time of 1 min made it possible to analyze more than 500 human plasma samples per day. A very low quantification limit of SF allowed the applicability of the developed method for determination of SF in a bioequivalence study in human volunteers. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
A robust, rapid and sensitive UPLC–MS/MS method has been developed, optimized and validated for the determination of amlodipine (AML) and atorvastatin (ATO) in human plasma using eplerenone as an internal standard (IS). Multiple‐reaction monitoring in positive electrospray ionization mode was utilized in Xevo TQD LC–MS/MS. Double extraction was used in sample preparation using diethyl ether and ethyl acetate. The prepared samples were analyzed using an Acquity UPLC BEH C18 (50 × 2.1 mm, 1.7 μm) column. Ammonium formate and acetonitrile, pumped isocraticaly at a flow rate of 0.25 mL/min, were used as a mobile phase. Method validation was done as per the US Food and Drug Administration guidelines. Linearity was achieved in the range of 0.1–10 ng/mL for AML and 0.05–50 ng/mL for ATO. Intra‐day and inter‐day accuracy and precision were calculated and found to be within the acceptable range. A short run time, of <1.5 min, permits analysis of a large number of plasma samples per batch. The developed and validated method was applied to estimate AML and ATO in a bioequivalence study in healthy human volunteers.  相似文献   

20.
Acetaminophen (APAP) is a widely used analgesic and antipyretic drug. It is mainly metabolized by phase 1 and 2 reactions in the liver, and thus it could be involved in many drug–drug interactions. Therefore, the study of APAP metabolism is important in toxicological and pharmacokinetic studies. The objective of this study was to develop a rapid and sensitive method for the determination of APAP and its six metabolites in rat plasma for the pharmacokinetic studies. APAP and its metabolites were separated through a Capcell Pak MGII C18 column and quantitated with a 16 min run in a triple‐quadruple mass spectrometer. The mobile phases were composed of 0.1% formic acid in either 95% water or 95% acetonitrile and analysis was performed twice in positive and negative modes. Validations such as accuracy, precision, recovery, matrix effect and stability were found to be within acceptance criteria of validation guidelines, indicating that the assay was applicable to the determination of the plasma concentrations of drug and its six metabolites. In conclusion, we developed an LC‐MS/MS method for the quantitative analysis of APAP and its six metabolites in rat plasma, and this method appears to be useful for pharmacokinetic/toxicokinetic studies of APAP and its metabolites in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   