首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A simple method is described for the simultaneous determination of vanilmandelic acid (VMA), 3,4-dihydroxyphenylacetic acid (DOPAC), 5-hydroxyindole-3-acetic acid (5-HIAA) and homovanillic acid (HVA) in urine. The compounds are isolated by a one-step sample clean-up on Sephadex G-10, separated by ion-pair reversed-phase liquid chromatography and detected electrochemically. A single analysis is completed within 65 min. Sample clean-up did not cause losses of the compounds of interest. The detection limits in urine were 0.4, 0.8, 1.0 and 1.6 mumol/l for VMA, DOPAC, 5-HIAA and HVA, respectively. 3,4-Dihydroxymandelic acid and vanillic acid (VA) were also detectable, but, under the chromatographic conditions used, they were not resolved from interfering components. VA and 5-HIAA could be analysed separately in the Sephadex G-10 eluate if more restrictive sampling conditions were used. Ingestion of bananas caused an increase of VMA, DOPAC, 5-HIAA and HVA in 24-h urine. After ingestion of vanilla an increased excretion of VA was observed, while the excretion of VMA, DOPAC and HVA was unaffected.  相似文献   

2.
A reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of benzoyl peroxide and the related compounds benzoic acid (BA), methylparaben, benzaldehyde, propylparaben, and ethyl benzoate. The compounds are separated on a column containing octadecyl silane chemically bonded to porous silica particles. The mobile phase is acetonitrile-buffer (45 + 55, v/v). Solutions are injected into the chromatographic system under isocratic conditions at a constant flow rate of 1.5 mL/min with UV detection at 235 nm. Analysis of stability samples showed rapid accumulation of BA by thermal degradation. A rationale has been established for the acceptable limit of BA in the formulation, which already contains BA (0.2%) as a preservative. The proposed method is efficient and determines the active compound and 5 related compounds in a run time of 20 min. The method was validated according to the guidelines of the International Conference on Harmonization and demonstrated good agreement with the validation requirements.  相似文献   

3.
A high-performance liquid chromatographic method is proposed for the simultaneous separation of main carboxylic acids, carbohydrates, ethanol, glycerol, and 5-HMF in beer by direct injection. A column packed with a sulfonated divinyl benzene-styrene copolymer and an isocratic elution with 0.0045N sulfuric acid and acetonitrile (6%, v/v) are employed. UV and refractive index detectors connected in series are also used to reduce the matrix interference of phenolic compounds. In conditions described, nine compounds are quantitated in a single chromatographic run without any pretreatment except for sample dilution and filtration before injection. Precision, accuracy, linearity of response, limit of detection, and limit of quantitation are also evaluated for each compound. Satisfactory results are obtained to justify the application of this method to all phases of beer production for process and quality control.  相似文献   

4.
Abstract

A comparison is made of chronoamperometric data recorded from the striatum and chromatographic data obtained from extracellular striatal perfusate. Three specific cases are considered: the initial sampling period in which a decline in the observed oxidation current occurs; the effect of haloperidol, a dopamine receptor blocker; and the effect of amphetamine. The perfusate is analyzed for ascorbic acid (AA), the dopamine metabolites dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA), and the serotonin metabolite 5-hydroxyindoleacetic acid (5-HIAA). Using the relative response of these compounds at a carbon epoxy or carbon paste electrode, and the relative concentration of each in the extracellular fluid, the expected changes in oxidation currents for the three cases mentioned above are calculated. It is shown that the decline in oxidation current during the initial sampling period is due primarily to a decrease in ascorbic acid. It is also shown that different electroactive components of the extracellular fluid are the cause of changing oxidation currents under different stimulus conditions.  相似文献   

5.
A novel ion chromatographic method was proposed for the simultaneous determination of artificial sweeteners (sodium saccharin, aspartame, acesulfame-K), preservatives (benzoic acid, sorbic acid), caffeine, theobromine and theophylline. The separation was performed on an anion-exchange analytical column operated at 40 degrees C within 45 min by an isocratic elution with 5 mM aqueous NaH2PO4 (pH 8.20) solution containing 4% (v/v) acetonitrile as eluent, and the determination by wavelength-switching ultraviolet absorbance detection. The detection limits (signal-to-noise ratio 3:1) for all analytes were below the sub-microg/ml level. Under the experimental conditions, several organic acids, including citric acid, malic acid, tartaric acid and ascorbic acid, did not interfere with the determination. The method has been successfully applied to the analysis of various food and pharmaceutical preparations, and the average recoveries for real samples ranged from 85 to 104%. The levels of all analytes determined by this method were in good agreement with those obtained by the high-performance liquid chromatographic procedure. The results also indicated that ion chromatography would be possibly a beneficial alternative to conventional high-performance liquid chromatography for the separation and determination of these compounds.  相似文献   

6.
A liquid chromatographic procedure is described for the analysis of the principal natural corticosteroids in extracts of adrenal glands. Microparticulate silicic acid columns and gradients of methanol in chloroform are used: conditions are described for the quantitative analysis of the single principal steroidal components of adrenal extracts for pharmaceutical use and of adrenal extracts of rats. In the last case, the use of a 5-micron silica column with the appropriate gradient allows the determination of corticosterone and of 18-hydroxydeoxycorticosterone, which were identified by means of mass spectrometry on their eluates. A single analysis can be performed on the extract of 15 mg of rat adrenal tissue. For the last type of analysis, isocratic conditions on a 10-micron LiChrosorb Diol column are also described. The application of the gradient elution procedure to the analysis of steroidal compounds in human plasma is also described.  相似文献   

7.
Five new chiral derivatizing reagents 5-hydrazino-2,4-dinitrophenyl-l-alaninamide (HDNP-l-Ala-NH2), 5-hydrazino-2,4-dinitrophenyl-l-phenylalaninamide (HDNP-l-Phe-NH2), 5-hydrazino-2,4-dinitrophenyl-l-valinamide (HDNP-l-Val-NH2), 5-hydrazino-2,4-dinitrophenyl-l-leucinamide (HDNP-l-Leu-NH2) and 5-hydrazino-2,4-dinitrophenyl-l-phenylglycinamide (HDNP-d-Phg-NH2) were synthesized by straightforward two-step synthesis starting from 1,5-difluoro-2,4-dinitrobenzene. Nucleophilic substitution of one fluorine atom in DFDNB with different amino acid amides yielded Marfey's reagent (5-fluoro-2,4-dinitrophenyl-l-alaninamide) and its structural variants (5-fluoro-2,4-dinitrophenyl-l-phenylalaninamide, 5-fluoro-2,4-dinitrophenyl-l-valinamide, 5-fluoro-2,4-dinitrophenyl-l-leucinamide and 5-fluoro-2,4-dinitrophenyl-d-phenylglycinamide). Chiral hydrazine reagents were prepared by nucleophilic substitution of remaining fluorine atom in Marfey's reagent and its variants with hydrazine under basic conditions. These reagents react quantitatively with chiral carbonyl compounds under mild conditions (30 degrees C, 30 min) to form hydrazone diastereomers. The labeling reaction occurs only in the presence of acid which has a catalytic action and diastereomers have strong absorbance around 348 nm. The separation of diastereomers was tried on a reversed-phase C18 HPLC column using different binary solvent combinations. Excellent separation was achieved in case of cyclic ketones having substitution at alpha-position. Optimization for derivatization yield, limit of detection, limit of quantification, linearity, accuracy and precision was carried out with respect to HDNP-l-Val-NH2. Studies related to effects of structural modification in reagents and analytes on chromatographic behavior of diastereomers were also analyzed.  相似文献   

8.
Oxyfunctionalization of the bioactive terpenoids, ursolic acid acetate (1), oleanolic acid acetate (5), lupeol acetate (12), and kaurenic acid (17), with dimethyldioxirane (DMDO) was investigated. Treatment of the terpenoids with DMDO under mild conditions afforded a variety of oxidation and oxydegradation products to yield naturally occurring and/or novel compounds in one step. After chromatographic separation, the structures of the individual isolated products were determined using spectroscopic methods including several homonuclear (1H-1H) and heteronuclear (1H-13C) shift-correlated 2D-NMR techniques. The inhibitory activity of the terpenoid derivatives against alpha-glucosidase was investigated and compounds 1, 3, 7, and 9 were found to exhibit potent activity.  相似文献   

9.
Optical resolution of the enantiomers of new 4(3H)-quinazolone derivatives is investigated using the alpha1-acid glycoprotein chiral stationary phase (Chiral-AGP). Stereoselective separation of the model compounds can be controlled by varying the pH and adding uncharged organic modifiers (acetonitrile and 2-propanol) to the mobile phase. For the majority of quinazolone derivatives, Chiral-AGP is proved to be an excellent enantioselector, because optimized chromatographic conditions allow for the baseline separation of the enantiomers. Separation factors between 1.19 and 1.85 are obtained. The effects of acetonitrile and 2-propanol on the chromatographic behavior of the model compounds are quite different because of their different hydrophobic- and hydrogen-bonding properties. The eluent pH and organic modifier concentration also contributes to the chiral recognition by altering the protein environment. The analysis of the experimental results leads to new information about the chromatographic mechanism on a Chiral-AGP surface.  相似文献   

10.
In this study the impact of solvent conditions on the performance of μLC/MS for the analysis of basic drugs was investigated. Our aim was to find experimental conditions that enable high-performance chromatographic separation particularly at overloading conditions paired with a minimal loss of mass spectrometric detection sensitivity. A focus was put on the evaluation of the usability of different kinds of acidic modifiers (acetic acid (HOAc), formic acid (FA), methansulfonic acid (CH3SO3H), trifluoroacetic acid (TFA), pentafluoropropionic acid (PFPA), and heptafluorobutyric acid (HFBA)). The test mixture consisted of eleven compounds (bunitrolol, caffeine, cocaine, codeine, diazepam, doxepin, haloperidol, 3,4-methylendioxyamphetamine, morphine, nicotine, and zolpidem). Best chromatographic performance was obtained with the perfluorinated acids. Particularly, 0.010–0.050% HFBA (v/v) was found to represent a good compromise in terms of chromatographic performance and mass spectrometric detection sensitivity. Compared to HOAc, on average a 50% reduction of the peak widths was observed. The use of HFBA was particularly advantageous for polar compounds such as nicotine; only with such a hydrophobic ion-pairing reagent chromatographic retention of nicotine was observed. Best mass spectrometric performance was obtained with HOAc and FA. Loss of detection sensitivity induced by HFBA, however, was moderate and ranged from 0 to 40%, which clearly demonstrates that improved chromatographic performance is able to compensate to a large extent the negative effect of reduced ionization efficiency on detection sensitivity. Applications of μLC/MS for the qualitative and quantitative analysis of clinical and forensic toxicological samples are presented.  相似文献   

11.
Four polar compounds, i.e. pantothenic acid, inositol, taurine and caffeine were used as probe solutes in conjunction with chemometric methods to find out meaningful implications of chromatographic conditions and detector settings on the system performance. Putting a premium on the conditions of hydrophilic interaction liquid chromatography (HILIC) and settings of evaporative light-scattering detection (ELSD), we scrutinize the importance of certain factors on signal-to-noise ratio and its variability. The application of a central composite design reveals that caffeine, which sublimes, differentiates from the relatively thermosensitive pantothenic acid as well as from inositol and taurine, which are thermostable, do not sublime and have high melting points. It seems that prior knowledge of solute characteristics is critical to estimate the chromatographic response as a function of chromatographic conditions and detection settings. Reducing the responses to just one by combining them “ad hoc”, results in an overall desirability function, which brings out the global optimal chromatographic conditions and detector settings.  相似文献   

12.
Three compounds were isolated from Phyllanthus niruri Linn. One effective method, improved dry column liquid chromatography for isolating these compounds, was applied on a silica gel column. It is a combination of conventional dry column chromatographic and flash chromatographic techniques. Structures of those obtained compounds were elucidated by means of spectral techniques including IR, MS, and 1D NMR and 2D NMR. Compound 1 was elucidated as 2,3,5,6-tetrahydroxybenzyl acetate. Compound 2 , 2,4,5-trihydroxy-3-(4,6,7-trihydroxy-3-oxo-1,3-dihydroisobenzofuran-5-yl)-benzoic acid methyl ester, was given the name phyllangin, and compound 3 was named corilagin. Compounds 1 and 2 are new compounds.Published in Khimiya Prirodnykh Soedinenii, No. 5, pp. 380–382, September–October, 2004.  相似文献   

13.
A liquid chromatographic procedure was developed for quantitative determination of histidine (His), histidinol (HDL), histamine (HTM), urocanic acid (URA), imidazolepyruvic acid (ImPA), imidazoleacetic acid (ImAA), and imidazolelactic acid (ImLA) in rumen fluid. The method is based on direct injection analysis by UV absorbance detection at 220 nm. The separation was performed under 2 different chromatographic conditions on a LiChrospher 100 NH2 column. In the first chromatographic system, the mobile phase used for isocratic elution was 67 mM potassium phosphate buffer (monobasic and dibasic) pH 6.45-90% acetonitrile in water (21 + 79); in the second system, an acetonitrile gradient in 63 mM potassium phosphate buffer (monobasic) pH 3.0, obtained by addition of 60 mM phosphoric acid, was used. Analyses of both systems were completed within 32 and 25 min, respectively. The limits of detection of these compounds were (microM): His, 2.8; HDL, 3.7; HTM, 4.0; URA, 0.75; ImPA, 4.7; ImAA, 1.2; and ImLA, 1.3. Recovery of these compounds added to rumen fluid was 97.4-103.0% within a 1-day study and 95.4-99.0% on different day studies. Detectable levels of His were found in the deproteinized rumen fluid of goats, with average concentrations of 16.10, 10.43, 11.14, and 13.62 microM in the rumen fluid collected before the morning feeding and 2, 4, and 6 h after feeding, respectively. HDL, HTM, URA, ImPA, ImAA, and ImLA were not detected in the rumen fluid before and after feeding. Trp, Phe, and Tyr were also identified in the rumen fluid, with average concentrations of 8.25, 29.04, and 12.6 microM, respectively, before the morning feeding.  相似文献   

14.
The study on retention behavior in supercritical fluid chromatography (SFC) is necessary to understand the mechanism of the various interactions in SFC. The retention of SFC in carboxylic acid methyl ester/polymethylsiloxane/CO2 system was studied systematically and the retention behavior of this kind of compounds under various typical operation conditions was described using the method of an alternative unified theory of chromatographic retention. The results illustrated that expression: Ink.= a + b/T + cp + dp/T + ep2/T can be used to describe quantitatively the retention behavior of carboxylic acid methyl ester/polymethylsiloxane/CO2 system in the ranges of reduced density from 0.549 to 1.411. It was also found that the entropy of solute in stationary phase is dependent on the density of supercritical fluid (SF) under typical operating conditions of SFC.  相似文献   

15.
A reversed-phase high-performance liquid chromatographic procedure for the simultaneous determination of impurities associated with pseudoephedrine hydrochloride (PSEH) and naproxen sodium (NapNa) is developed and validated. The method is developed using a Waters Spherisorb cyano column (5 microm, 250 x 4.6 mm). An isocratic elution in a water-acetonitrile-methanol-triethylamine mixture (850:75:75:5) is adjusted to a pH of 3.7 +/- 0.02 with formic acid as the mobile phase. The UV detection was set at 260 nm, and the wavelength was switched to 235 nm before the elution of the last component, 2-ethyl-6-methoxy-naphthalene (EMN). The method is shown to be linear at a concentration range of 0.24 to 1.92 microg/mL for benzaldehyde, benzoic acid, and 2-(methylamino)-propiophenone hydrochloride, which are known impurities of PSEH. The NapNa impurities, 2-(6'-hydroxy-2'-naphthyl) propionic acid, 2-hydroxy-6-methoxy-naphthalene, 1-(6'-methoxy-2'-naphthyl) ethanol, 2-acetyl-6-methoxy-naphthalene, and EMN are also demonstrated to be linear at a concentration range of 0.44 to 3.52 microg/mL. Under the chromatographic conditions of the method, all impurities are resolved from the active components.  相似文献   

16.
Liu H  Shao J  Li Q  Li Y  Yan HM  He L 《Journal of AOAC International》2012,95(4):1138-1141
A simple, rapid method was developed for simultaneous extraction of trigonelline, nicotinic acid, and caffeine from coffee, and separation by two chromatographic columns in series. The trigonelline, nicotinic acid, and caffeine were extracted with microwave-assisted extraction (MAE). The optimal conditions selected were 3 min, 200 psi, and 120 degrees C. The chromatographic separation was performed with two columns in series, polyaromatic hydrocarbon C18 (250 x 4.6 mm id, 5 microm particle size) and Bondapak NH2 (300 x 3.9 mm id, 5 microm particle size). Isocratic elution was with 0.02 M phosphoric acid-methanol (70 + 30, v/v) mobile phase at a flow rate of 0.8 mL/min. Good recoveries and RSD values were found for all analytes in the matrix. The LOD of the three compounds was 0.02 mg/L, and the LOQ was 0.005% in the matrix. The concentrations of trigonelline, nicotinic acid, and caffeine in instant coffee, roasted coffee, and raw coffee (Yunnan Arabica coffee) were assessed by MAE and hot water extraction; the correlation coefficients between concentrations of the three compounds obtained were close to 1.  相似文献   

17.
A micellar electrokinetic chromatographic (MEKC) method was developed for the quantification of mesalazine or 5-aminosalicylic acid (5-ASA) and its major impurities 3-aminosalicylic acid, salicylic acid, sulfanilic acid and 4-aminophenol. The optimisation of the experimental conditions was carried out considering some important requirements: resolution, reproducibility, detection limits of 0.1% (m/m) or less, short total analysis time. Preliminary investigations employing sodium dodecyl sulfate (SDS) as surfactant did not lead to the necessary resolution of the studied compounds; the addition of tetrabutylammonium bromide (TBAB) to the SDS micellar system resulted in the complete separation of all the compounds. The effects on the separation by several parameters such as TBAB concentration, SDS concentration, background electrolyte pH and concentration, were evaluated. Using a fused-silica capillary (8.5 cm effective length) complete analysis was obtained in a very short time. Under the optimised final conditions [120 mM 3-(cyclohexylamino)-2-hydroxy-1-propanesulfonic acid buffer, pH 10.20, 65 mM SDS in the presence of 55 mM TBAB and 5% methanol] the method was validated for specificity, precision, linearity, limits of detection and quantitation, and robustness: the 5-ASA related impurities can be quantified at least at the 0.1% (m/m) level.  相似文献   

18.
A new high-performance liquid chromatographic method to investigate many folate monoglutamate compounds was developed. This method employed a Cosmosil 5-Ph column eluted with 10 mM potassium phosphate buffer (pH 7.0) containing 1% methanol at a flow-rate of 1.0 ml/min. Under these conditions, almost all of the physiological folate monoglutamate compounds were effectively separated and determined within 22 min. By applying this method to investigate the absorption and conversion of pteroylglutamic acid in the rat small intestine, it was demonstrated that pteroylglutamic acid was converted into 5-methyltetrahydrofolic acid during absorption, and that the conversion was a saturable process, whereas unchanged pteroylglutamic acid was absorbed almost linearly in proportion to the initial amount administered.  相似文献   

19.
A method was developed for quantitative measurement of trans,trans-muconic acid, catechol, hydroquinone and phenol in urine. Hydrolysis of esterified and glucuronized phenolic compounds was effected by specific enzymes. The hydrolysed mixture was purified and separated by solid-phase extraction with an anion exchanger, followed by extraction with diethyl ether. By using a clean-up procedure the natural background from mouse urine could be reduced, so that the detection limit of the metabolites was in the range 3-60 mg/l. Optimization of the chromatographic conditions resulted in a short high-performance liquid chromatography analysis time. Phenol had the longest retention time of about 10 min. The clean-up procedure could also be used for phenylmercapturic acid, an additional benzene metabolite, but for sensitive high-performance liquid chromatographic detection of phenylmercapturic acid other conditions are necessary.  相似文献   

20.
A new index is proposed for the prediction of the chromatographic retention of the cis- and trans-n-alkene isomers and alkanes. This index is based on the hypothesis that the chromatographic retention of the molecule is due to the interaction of each carbon atom with the stationary phase, and consequently the index is reduced by its neighbours' steric effects. The topological values are obtained by a numerical approximation considering the general behaviour of the chromatographic retention of the compounds. The simple linear regressions between the chromatographic retention and the index proposed for all branched alkanes and also isomers of the studied straight-chain C5 and C14 alkenes (1-ene, cis- and trans-2-, 3-, 4-, 5-, 6- and 7-enes) is very good (the correlation coefficient is r = 0.9999), and the elution sequence is correct for most of them. The models have a high predictive ability, as established by cross-validation values (r2cv). Thus, this new method, different from those already existent, can be used as complementary tool for the elucidation of the molecular structure, or prediction of the chromatographic retention of the cis- and trans-alkene isomers and branched alkanes. It could be extended with success, in the future, to the other types of compounds.  相似文献   