首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Metal-molecule-metal junctions were fabricated by contacting Au-supported alkyl or benzyl thiol self-assembled monolayers (SAMs) with an Au-coated atomic force microscope (AFM) tip. The tip-SAM microcontact is approximately 15 nm(2), meaning the junction contains approximately 75 molecules. Current-voltage (I-V) characteristics of these junctions were probed as a function of SAM thickness and load applied to the microcontact. The measurements showed: (1) the I-V traces were linear over +/-0.3 V, (2) the junction resistance increased exponentially with alkyl chain length, (3) the junction resistance decreased with increasing load and showed two distinct power law scaling regimes, (4) resistances were a factor of 10 lower for junctions based on benzyl thiol SAMs compared to hexyl thiol SAMs having the same thickness, and (5) the junctions sustained fields up to 2 x 10(7) V/cm before breakdown. I-V characteristics determined for bilayer junctions involving alkane thiol-coated tips in contact with alkane thiol SAMs on Au also showed linear I-Vs over +/-0.3 V and the same exponential dependence on thickness. The I-V behavior and the exponential dependence of resistance on alkyl chain length are consistent with coherent, nonresonant electron tunneling across the SAM. The calculated conductance decay constant (beta) is 1.2 per methylene unit ( approximately 1.1 A(-)(1)) for both monolayer and bilayer junctions, in keeping with previous scanning tunneling microscope and electrochemical measurements of electron transfer through SAMs. These measurements show that conducting probe-AFM is a reliable method for fundamental studies of electron transfer through small numbers of molecules. The ability to vary the load on the microcontact is a unique characteristic of these junctions and opens opportunities for exploring electron transfer as a function of molecular deformation.  相似文献   

2.
The friction and lateral stiffness of the contact between an atomic force microscopy (AFM) probe tip and an atomically flat dolomite (104) surface were investigated in contact with two aqueous solutions that were in equilibrium and supersaturated with respect to dolomite, respectively. The two aqueous solutions yielded negligible differences in friction at the native dolomite-water interface. However, the growth of a Ca-rich film from the supersaturated solution, revealed by X-ray reflectivity measurements, altered the probe-dolomite contact region sufficiently to observe distinct friction forces on the native dolomite and the film-covered surface regions. Quantitative friction-load relationships demonstrated three physically distinct load regimes for applied loads up to 200 nN. Similar friction forces were observed on both surfaces below 50 nN load and above 100 nN load. The friction forces on the two surfaces diverged at intermediate loads. Quantitative measurements of dynamic friction forces at low load were consistent with the estimated energy necessary to dehydrate the surface ions, whereas differences in mechanical properties of the Ca-rich film and dolomite surfaces were evidently important above 50 nN load. Attempts to fit the quantitative stiffness-load data using a Hertzian contact mechanical model based on bulk material properties yielded physically unrealistic fitting coefficients, suggesting that the interfacial contact region must be explicitly considered in describing the static and dynamic contact mechanics of this and similar systems.  相似文献   

3.
Liposomes that are surface-bound to a biomaterial such as a contact lens are of interest for localized delivery of therapeutic agents, but it is not known whether such liposome layers are sufficiently robust. The stability of a dense, PEG-functionalized layer of liposomes, affinity-bound onto a multilayer coated surface, was tested under various stress conditions using colloid-probe atomic force miscroscopy (AFM). The different stress effects were generated by varying the applied normal load of the probe and the impinging fluid shear through different approach velocities and by varying the applied lateral forces by scanning under increasing force loads. The effect of applied forces (normal and lateral) was further investigated by coating the probe with a layer of albumin. The liposomes remained intact following the ramping of both protein-coated and uncoated probes under the normal and lateral loads. The low-fouling nature of these liposomes, with respect to nonspecific protein adsorption, was also demonstrated from the interaction force measurements which showed only weak adhesion from the protein layer during the contact period of the albumin-coated probe. The observed adhesive interactions were concluded to be a direct result of the applied load from the probe, during the force measurements, rather than from attraction of the protein molecules for the surface-bound liposomes. The low frictional response of the liposome layer indicated the viscoelastic nature of these molecules, which enabled liposome structure retention during the continuous load application. The demonstrated stability of the liposomes presents a system of viable and localized drug delivery in, for example, ophthalmic applications.  相似文献   

4.
Interaction forces between surfaces designed to be protein resistant and fibrinogen (Fg) were investigated in phosphate-buffered saline with colloid probe atomic force microscopy. The surfaces of the silica probes were coated with a layer of fibrinogen molecules by adsorption from the buffer. The technique of low-power, pulsed AC plasma polymerization was used to make poly(ethylene glycol) (PEG)-like coatings on poly(ethylene teraphthalate) by using diethylene glycol vinyl ether as the monomer gas. The degree of PEG-like nature of the films was controlled by use of a different effective plasma power in the chamber for each coating, ranging from 0.6 to 3.6 W. This produced a series of thin films with a different number of ether carbons, as assessed by X-ray photoelectron spectroscopy. The interaction force measurements are discussed in relation to trends observed in the reduction of fibrinogen adsorption, as determined quantitatively by (125)I radio-labeling. The plasma polymer coatings with the greatest protein-repelling properties were the most PEG-like in nature and showed the strongest repulsion in interaction force measurements with the fibrinogen-coated probe. Once forced into contact, all the surfaces showed increased adhesion with the protein layer on the probe, and the strength and extension length of adhesion was dependent on both the applied load and the plasma polymer surface chemistry. When the medium was changed from buffer to water, the adhesion after contact was eliminated and only appeared at much higher loads. This indicates that the structure of the fibrinogen molecules on the probe is changed from an extended conformation in buffer to a flat conformation in water, with the former state allowing for stronger interaction with the polymer chains on the surface. These experiments underline the utility of aqueous surface force measurements toward understanding protein-surface interactions, and developing nonfouling surfaces that confer a steric barrier against protein adsorption.  相似文献   

5.
Using conducting probe atomic force microscopy (CP-AFM), we have formed molecular tunnel junctions consisting of alkanethiols and alkane isonitrile self-assembled monolayers sandwiched between gold, platinum, silver, and palladium contacts. We have measured the resistance of these junctions at low bias (dV/dI |V=0) as a function of alkane chain length. Extrapolation to zero chain length gives the contact resistance, R0 . R0 is strongly dependent on the type of metal used for the contacts and decreases with increasing metal work function; that is, R0,Ag > R0,Au > R0,Pd > R0,Pt. R0 is approximately 10% smaller for Au junctions with isonitrile versus thiol surface linkers. We conclude that the Fermi level of the junction lies much closer to the HOMO than to the LUMO.  相似文献   

6.
The mechanical and electrical properties of CdTe tetrapod-shaped nanocrystals have been studied with atomic force microscopy. Tapping mode images of tetrapods deposited on silicon wafers revealed that they contact the surface with three of its arms. The length of these arms was found to be 130+/-10 nm. A large fraction of the tetrapods had a shortened vertical arm as a result of fracture during sample preparation. Fracture also occurs when the applied load is a few nanonewtons. Compression experiments with the atomic force microscope tip indicate that tetrapods with the shortened vertical arm deform elastically when the applied force was less than 50 nN. Above 90 nN additional fracture events occurred that further shortened the vertical arm. Loads above 130 nN produced irreversible damage to the other arms as well. Current-voltage characteristics of tetrapods deposited on gold revealed a semiconducting behavior with a current gap of approximately 2 eV at low loads (<50 nN) and a narrowing to about 1 eV at loads between 60 and 110 nN. Atomistic force field calculations of the deformation suggest that the ends of the tetrapod arms are stuck during compression so that the deformations are due to bending modes. Empirical pseudopotential calculation of the electron states indicates that the reduction of the current gap is due to electrostatic effects, rather than strain deformation effects inside the tetrapod.  相似文献   

7.
We use a modified conducting atomic force microscope to simultaneously probe the conductance of a single-molecule junction and the force required to rupture the junction formed by alkanes terminated with four different chemical link groups which vary in binding strength and mechanism to the gold electrodes. Molecular junctions with amine, methylsulfide, and diphenylphosphine terminated molecules show clear conductance signatures and rupture at a force that is significantly smaller than the measured 1.4 nN force required to rupture the single-atomic gold contact. In contrast, measurements with a thiol terminated alkane which can bind covalently to the gold electrode show conductance and force features unlike those of the other molecules studied. Specifically, the strong Au-S bond can cause structural rearrangements in the electrodes, which are accompanied by substantial conductance changes. Despite the strong Au-S bond and the evidence for disruption of the Au structure, the experiments show that on average these junctions also rupture at a smaller force than that measured for pristine single-atom gold contacts.  相似文献   

8.
We explore the compression moduli of a thin biological tissue through probe microscopy. The elastic modulus (E') of isolated stratum corneum is measured at varying depths through the use of an atomic force microscope (AFM) as well as a nano-indentor (Hysitron Triboscope). In addition, a nano-DMA is used to measure visco-elastic properties. Measurements on dry and hydrated stratum corneum show an order of magnitude difference in E' and the measured tandelta (E'/E') is seen to increase from approximately 0.1 to 0.25. In addition, extensive validation of the experiments is conducted with different indentation probes at different force ranges to reveal the effects of indentor geometry and indentation depth on the measured elastic modulus. The sensitivity of the measurements is tested with applying known treatments to stratum corneum and exploring their effects on biomechanical parameters.  相似文献   

9.
We have measured the single intermolecular force of a typical photoionizable molecule, spirobenzopyran, by means of atomic force microscopy, which has proven to be useful in measuring directly single molecular forces. The spirobenzopyran moiety was immobilized covalently on both Au-coated probe tips and substrates by use of a self-assembled monolayer of a hexanethiol derivative incorporating a terminal spirobenzopyran moiety, 1'-(6'-mercaptohexyl)-3',3'-dimethylindolino-6-nitrospiro-(2H-1-benzopyran-2,2'-indoline). Force curve measurements were carried out using the spirobenzopyran-modified probe tip and substrate under dark conditions and in situ UV light irradiation. The adhesion force observed in a polar solvent (i.e., ethanol) was increased substantially under in situ UV light irradiation, which caused photoisomerization of the spirobenzopyran moiety bound to both tip and substrate from its electrically neutral spiropyran form to the corresponding zwitterionic merocyanine one. Statistical analyses of the observed force by autocorrelation technique have revealed that the photoionization enhanced by UV light caused a remarkable increase in the single intermolecular force of the photochromic compound.  相似文献   

10.
Previous work has shown that protein molecules can be trapped between the conductive surfaces presented by a metal-coated AFM probe and an underlying planar substrate where their molecule-specific conductance characteristics can be assayed. Herein, we demonstrate that transport across such a derived metal-protein-electrode junction falls within three, pressure-dependent, regimes and, further, that pressure-dependent conductance can be utilized in analyzing temporal variations of protein fold. Specifically, the electronic and mechanical properties of the metalloprotein azurin have been characterized under conditions of anisotropic vertical compression through the use of a conducting atomic force microscope (CP-AFM). By utilizing the ability of azurin to chemically self-assemble on the gold surface presented either by the apex of a suitably coated AFM probe or a planar metallic surface, molecular-level transport characteristics are assayable. Under conditions of low force, typically less than 2 nN, the weak physical and electronic coupling between the protein and the conducting contacts impedes tunneling and leads to charge buildup followed by dielectric breakdown. At slightly increased force, 3-5 nN, the copper protein exhibits temporal electron occupation with observable negative differential resistance, while the redox-inactive zinc mutant does not. At imposed loads greater than 5 nN, appreciable electron tunneling can be detected even at low bias for both the redox-active and -inactive species. Dynamic current-voltage characteristics have been recorded and are well-described by a modified Simmons tunneling model. Subsequent analyses enable the electron tunneling barrier height and barrier length to be determined under conditions of quantified vertical stress. The variance observed describes, in essence, the protein's mechanical properties within the confines of the tunnel junction.  相似文献   

11.
We present a quantitative study of the nanoscale frictional properties of one-component (pure) and two-component (mixed) alkylsilane self-assembled monolayers (SAMs). The load and velocity dependence of the friction force was measured in air and ethanol using lateral force microscopy (LFM). It was observed that for SAMs with well-ordered structure (pure SAMs and mixed SAMs composed of two long chain molecules) friction depends nonlinearly on load, at low loads, both in air and in ethanol. These observations are consistent with the low-load contact area predictions of the Johnson-Kendall-Roberts (JKR) theory, indicating that for well-ordered SAMs friction force is proportional to contact area and that the true contact area is determined by elastic deformation of the SAM by the LFM probe. In ambient air, the magnitude of the friction force measured using mixed SAMs is found to be similar to that obtained using pure SAMs at the same external load. Changing the medium to ethanol, however, leads to dramatically lower friction in the mixed SAMs. An analysis of the friction data using a thermally activated Eyring model that takes into account the monolayer viscoelasticity suggests that the better friction properties of the mixed SAMs are a consequence of greater disorder and higher molecular mobility in the outer layer/canopy. These findings indicate that multi-tiered SAM coatings comprising a highly ordered underlayer and a disordered, mobile canopy can provide the basis for low-friction coatings for small mechanical systems.  相似文献   

12.
The mechanical and electrical properties of the phosphor‐doped nano‐silicon film (nc‐Si:H) prepared by the plasma‐enhanced chemical vapor deposition (PECVD) method under electric field have been studied by Tribolab system, which is equipped with nano‐electrical contact resistance (ECR) tool. During indentation, different voltages and loads were applied. The topography of the sample surface was studied by atomic force microscopy (AFM). The experimental results show that the roughness of the film is 5.69 nm; the electric current was measured through the sample/indenter tip with different loads at a fixed voltage, and it increased nonlinearly during the indentation. The maximum current value depth was shallower than the maximum depth of each indent due to the plasticity of the film. When the loading speed is increased to 250 µN/s, the microcrack occurred on the film; the hardness (H) and elastic modulus (E) changed with the voltage applied both in open circuit and in short circuit case, which resulted in different values of H/E rate from 0.082 to 0.096. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
Nanomechanical properties of globular proteins: lactate oxidase   总被引:1,自引:0,他引:1  
We report on the study of the nanomechanical properties of a lactate oxidase (LOx) monolayer immobilized on gold substrates by atomic force microscopy techniques operating under buffer conditions. Topographical contact mode imaging evidenced the protein deformation under the applied tip load. We performed approaching force curves with both stiff and soft cantilevers by imposing maximum loads of 1.6 nN and 400 pN, respectively. We found that the experimental data were well fitted by the Hertz model for a conical indenter. The use of two types of cantilevers allowed us to check further the consistency of the applicability of the Hertz model to the experimental data. After analyzing 180 curves, we obtained an average value of Young's modulus for the LOx layer in the 0.5-0.8 GPa range. These results agreed with those obtained for LOx submonolayer deposits on mica substrates, which allows discarding any important contribution from the underlying substrate on the measured properties. This range of values is closer to those obtained by other techniques on other globular proteins in comparison with those reported in previous AFM studies on similar systems. We found that for our experimental conditions the force curves can be, in principle, well fitted by the Hertz model for both conical and spherical indenter geometries. However, as the Young's modulus obtained for both geometries can differ appreciably, it becomes necessary to assess which indenter geometry is more adequate to explain the experimental data. For such purpose a systematic study of the indentation versus applied force curves obtained from both fittings for all the experimental curves was done.  相似文献   

14.
Quantification of the mechanical properties of cellulose nanomaterials is key to the development of new cellulose nanomaterial based products. Using contact resonance atomic force microscopy we measured and mapped the transverse elastic modulus of three types of cellulosic nanoparticles: tunicate cellulose nanocrystals, wood cellulose nanocrystals, and wood cellulose nanofibrils. These modulus values were calculated with different contact mechanics models exploring the effects of cellulose geometry and thickness on the interpretation of the data. While intra-particle variations in modulus are detected, we did not observe a measureable difference in modulus between the three types of cellulose particles. Improved practices and experimental complications for the characterization of cellulosic nanomaterials with atomic force microscopy are discussed.  相似文献   

15.
The sliding friction between single silica microspheres was examined by applying friction force microscopy to probe the interaction between spherical silica particles glued to a tipless atomic force microscopy (AFM) cantilever and another particle glued to a glass slide. A three-dimensional model handling the complex contact geometry between spherical particles was established to compute friction and normal forces at the sliding interface from measured deflections of the AFM cantilever. Results obtained at different loads show a linear relationship between friction and normal force, with a friction coefficient of 0.4 between silica spheres. Friction in this system occurs at multi-asperity contacts. The results show that the macroscopic friction law of Amontons can be used to model the friction behavior of micrometer-sized granular matter. For plasma-treated silica particles, increased friction as well as wear could be observed during sliding.  相似文献   

16.
The effect of condensed water on pull-off forces under high vacuum (HV) and 0 to 83% relative humidity (RH) N2 atmospheric conditions was evaluated for different contact geometries using atomic force microscopy (AFM). The pull-off force was measured using two types of contact geometry: contact between hemispherical asperities and a flat silicon probe on an AFM cantilever (called a spherical-flat contact) and between a flat silicon substrate and a flat nickel probe on an AFM cantilever (called a flat-flat contact). The hemispherical asperities were fabricated using a focused ion beam (FIB) system, and each peak had a radius of curvature of between 70 and 610 nm. The flat nickel probe was fabricated by friction-induced wear. Measurement results showed that for the spherical-flat contact the pull-off force was proportional to the radius of curvature of the asperity peak and was slightly lower in HV than in humid 14% RH N2. For the flat-flat contact in HV, with increasing contact time, the pull-off force increased in HV but decreased in humid 62 and 83% RH N2. The pull-off force in HV was lower than that in humid N2 when the contact time was less than 10 s but was higher when the contact time was longer than 30 s. The estimated adhesion force based on the Laplace pressure from the contact geometry agreed reasonably well with the measured pull-off force.  相似文献   

17.
Continuum mechanics models describing the contact between two adhesive elastic spheres, such as the JKR and DMT models, provide a relationship between the elastic indentation depth and the normal load, but the general intermediate case between these two limiting cases requires a more complex analysis. The Maugis-Dugdale theory gives analytical solutions, but they are difficult to use when comparing to experimental data such as those obtained by scanning force microscopy. In this paper we propose a generalized equation between elastic indentation depth and load that approximates Maugis' solution very closely. If the normal contact stiffness can be described as the force gradient, that is the case of the force modulation microcopy, then a generalized equation between normal contact stiffness and load can be deduced. Both general equations can be easily fit to experimental data, and then interfacial energy and elastic modulus of the contact can be determined if the radius of the indenting sphere is known. Copyright 2000 Academic Press.  相似文献   

18.
导电原子力显微镜对蛋白质在分子水平上的电学表征   总被引:2,自引:0,他引:2  
蛋白质电子传递的研究不仅对阐述生物能量传递具有重要的意义,而且有助于促进生物分子在分子电子器件中的应用.金属蛋白以其固有的电化学和电学特性,在光合作用和呼吸作用中起到重要作用.其中铜蓝蛋白具有良好的电化学性质和明确的分子结构,常常用作研究蛋白质电子传递的模型分子。很多具有微观尺度表征能力的分析仪器可用于研究表面吸附的蛋白质分子。  相似文献   

19.
非接触原子力显微技术(NC-AFM)近年来发展迅速. NC-AFM对单个分子的成像和谱学实现了原子分辨和单个化学键分辨. NC-AFM自身功能的拓展及其与不同探针技术的联用将为材料、物理、化学和生命科学有关的研究提供崭新的思路. 本文首先介绍NC-AFM和qPlus 传感器的基本原理, 然后讨论原子尺度的相互作用力和短程力的精确测量, 总结近年来NC-AFM在原子尺度的化学结构成像、化学识别、电子结构性质分析以及原子操纵技术中的研究进展, 并讨论了开尔文探针力显微技术(KPFM)在局域接触势差(LCPD)测量方面的应用. 最后展望了NC-AFM面临的挑战和发展机遇.  相似文献   

20.
Nanografting, an atomic force microscopy (AFM) based nanolithography technique, is becoming a popular method for patterning self-assembled monolayers (SAMs). In this technique, a nanoscale patch of a thiol-on-gold SAM is exchanged with a different thiol by the action of an AFM tip operated in contact mode at high load. The results are then imaged in topographic or lateral force microscopy again at low values of the load. One of the problems of contact mode nanografting is that monolayers of large molecules such as proteins are likely to be deformed, damaged, or even removed from the surface by contact mode imaging even when small loads are used. Furthermore, we need to note that the stiffness of the cantilevers used in contact mode is different than that of the cantilevers used in tapping mode and that tip changing in the course of an experiment can be quite inconvenient. Here, we show that a monolayer on a gold substrate can be nanografted using tapping mode AFM (also referred to as amplitude modulation AFM) rather than the commonly used contact mode. While the grafting parameters are somewhat trickier to choose, the results demonstrate that nanografting in tapping mode can make patches of the same quality as those made by contact mode, therefore allowing for gentle imaging of the grafted molecules and the whole SAM without changing the microscope tip.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号