共查询到20条相似文献,搜索用时 31 毫秒
1.
Marcela Nogueira Rabelo Alves Gabriele Zanchetti Alberto Piccinotti Silvia Tameni Bruno Spinosa De Martinis Aldo Polettini 《Analytical and bioanalytical chemistry》2013,405(19):6299-6306
A method for rapid, selective, and robust determination of cocaine (CO) and metabolites in 5-mg hair samples was developed and fully validated using a column-switching liquid chromatography–tandem mass spectrometry system (LC-MS-MS). Hair samples were decontaminated, segmented, incubated overnight in diluted HCl, and centrifuged, and the diluted (1:10 with distilled water) extracts were analyzed in positive ionization mode monitoring two reactions per analyte. Quantifier transitions were: m/z 304.2→182.2 for CO, m/z 290.1→168.1 for benzoylecgonine (BE), and m/z 318.2→196.2 for cocaethylene (CE). The lower limit of quantification (LLOQ) was set at 0.05 ng/mg for CO and CE, and 0.012 ng/mg for BE. Imprecision and inaccuracy at LLOQ were lower than 20 % for all analytes. Linearity ranged between 0.05 and 50.0 ng/mg for CO and CE and 0.012 and 12.50 ng/mg for BE. Selectivity, matrix effect, process efficiency, recovery, carryover, cross talk, and autosampler stability were also evaluated during validation. Eighteen real hair samples and five samples from a commercial proficiency testing program were comparatively examined with the proposed multidimensional chromatography coupled with tandem mass spectrometry procedure and our reference gas chromatography coupled to mass spectrometry (GC-MS) method. Compared with our reference GC-MS method, column-switching technique and the high sensitivity of the tandem mass spectrometry detection system allowed to significantly reduce sample amount (×10) with increased sensitivity (×2) and sample throughput (×4), to simplify sample preparation, and to avoid that interfering compounds and ions impaired the ionization and detection of the analytes and deteriorate the performance of the ion source. 相似文献
2.
3.
Kim SR Wipfli H Avila-Tang E Samet JM Breysse PN 《Biomedical chromatography : BMC》2009,23(3):273-279
The development of strategies to address the growing worldwide burden of exposure to secondhand smoke (SHS) would be facilitated by sensitive and accurate methods for assessing SHS exposure. Hair provides a readily available matrix for assessing biomarkers of typical SHS exposure. We developed and applied an optimized analytical method using an isotope dilution gas chromatography-mass spectrometry (GC/MS) for hair nicotine measurement. The utility of this optimized method is illustrated by presenting data on SHS exposure of women and children from 31 countries. Using this isotope dilution method with spiked samples (3.3 ng/mg), we found that the greatest hair nicotine extraction efficiency was obtained with a 60 min shaking time. In the field study (n = 2400), a positive association was evident between hair nicotine concentrations from nonsmokers and higher numbers of cigarettes smoked per day in a household. 相似文献
4.
Methamphetamine (MA) is a sympathomimetic amine whose abuse has become a serious problem in Japan, Korea, Taiwan and other Southeast Asian countries. The use of hair for the determination of MA use has become more commonplace. The maximum period in which MA and its main metabolites (amphetamine and p-hydroxymethamphetamine) can be detected in urine is about 10 days after its use. However, proof of MA use is possible in hair even several years after its use if the part of the hair that grew in the period of its use is available. In addition, segmental analysis of hair is capable of clarifying the history of MA abuse. This paper reviews the clean-up, extraction, analytical method and distribution of MA and its metabolites in hair from reports published in the last 20 years. 相似文献
5.
Vogliardi S Favretto D Frison G Ferrara SD Seraglia R Traldi P 《Journal of mass spectrometry : JMS》2009,44(1):18-24
Matrix-assisted laser desorption/ionisation (MALDI) mass spectrometry was used for the rapid detection of cocaine, benzoylecgonine and cocaethylene in hair. Different MALDI sample preparation procedures have been tested and the employment of a multi-layer 'graphite-sample-electrosprayed alpha-cyano-4-hydroxycinnamic acid (HCCA)' yielded the best results for standard solutions of the target analytes. The same approach was subsequently applied to hair samples that were known to contain cocaine, benzoylecgonine and cocaethylene, as determined by a classical GC-MS method. It was however necessary to extract hair samples by incubating them in methanol/trifluoroacetic acid for a short time (15 min) at 45 degrees C; 1 microl of the obtained supernatant was deposed on a metal surface treated with graphite, and HCCA was electrosprayed on it. This procedure successfully suppressed matrix peaks and was effective in detecting all the target analytes as their protonated species. The results obtained give further confirmation of the effectiveness of the MALDI for detecting drugs and their metabolites in complex biological matrices. The method can be useful as a fast screening procedure to detect the presence of cocaine and metabolites in hair samples. 相似文献
6.
7.
An original HPLC method coupled to spectrofluorimetric detection is presented for the simultaneous analysis in dried blood spots (DBS) of cocaine and two important metabolites, namely benzoylecgonine (its main metabolite) and cocaethylene (the active metabolite formed in the presence of ethanol). The chromatographic analysis was carried out on a C8 column, using a mobile phase containing phosphate buffer (pH 3.0)-acetonitrile (85:15, v/v). Native analyte fluorescence was monitored at 315 nm while exciting at 230 nm. A fast and feasible sample pre-treatment was implemented by solvent extraction, obtaining good extraction yields (>91%) and satisfactory precision values (RSD<4.8%). The method was successfully applied to DBS samples collected from some cocaine users, both with and without concomitant ethanol intake. The results were in good agreement with those obtained from plasma samples subjected to an original solid-phase extraction procedure on C8 cartridges. The method has demonstrated to be suitable for the monitoring of cocaine/ethanol use by means of DBS or plasma testing. Assays are in progress to apply this method on the street, for the control of subjects suspected of driving under the influence of psychotropic substances. 相似文献
8.
Vogliardi S Favretto D Tucci M Stocchero G Ferrara SD 《Analytical and bioanalytical chemistry》2011,400(1):51-67
A liquid chromatography–high resolution mass spectrometry (LC-HRMS) method for the simultaneous identification and quantification
of 28 benzodiazepines, including 6 metabolites, in 50 mg of hair has been validated. Positive ion electrospray ionization
and HRMS determination in full-scan mode were realized on an Orbitrap mass spectrometer at a nominal resolving power of 60,000.
In-source collisional experiments were conducted to obtain additional information for a more reliable identification of the
investigated drugs. HRMS in full-scan mode allowed the exact determination of molecular masses of all analytes eluting in
the HPLC run, so that both the immediate and retrospective screening of results for drugs and their metabolites were available.
Sample preparation consisted of an overnight incubation in phosphate buffer pH 8.4 and a subsequent liquid/liquid extraction
with methylene chloride/diethyl ether (90:10). Gradient elution was performed on a Luna C18 analytical column and four deuterated
analogues were used as internal standards (IS). Validation was performed using both spiked hair samples and hair samples from
subjects treated with benzodiazepines. Selectivity was evaluated by analysis of 20 certified blank hair samples. Extraction
efficiency and matrix effects were evaluated by analysis of true positive samples. The lowest limits of quantification (LLOQs)
ranged from 1 to 10 pg/mg. Linearity was investigated in the range from LLOQ to 1,000 pg/mg, for each compound (R
2 0.998–0.999). Mean relative errors, calculated at three concentration levels, ranged from 1 to 20% (absolute value). Precision,
at concentrations higher than the LLOQs, was always less than 15% expressed as percentage relative standard deviation. After
validation, the procedure was applied to real samples collected for clinical and forensic toxicology purposes from subjects
who were assumed to have taken benzodiazepines. 相似文献
9.
Jihyun Kim Sanghwan In Yuran Park Meejung Park Eunmi Kim Sooyeun Lee 《Analytical and bioanalytical chemistry》2013,405(30):9769-9778
Analysis of drugs in hair is often used as a routine method to obtain detailed information about drug ingestion. However, few studies have been conducted on deposition of synthetic cannabinoids and metabolites in hair. The first purpose of this study was to establish and validate an analytical method for detection of JWH-018, JWH-073, and their metabolites in hair, by use of UHPLC–MS–MS, for forensic application. The second purpose was to investigate the distribution of synthetic cannabinoids metabolites in hair and the effect of hair pigmentation, by use of an animal model. For this, JWH-073 was chosen as a representative synthetic cannabinoid. Finally, the developed method was applied to hair samples from 18 individuals suspected of synthetic cannabinoids use. JWH-018, JWH-073, and their metabolites were extracted from hair with methanol. The extract was then filtered and analyzed by UHPLC–MS–MS with an electrospray ion source in positive-ionization mode. Validation proved the method was selective, sensitive, accurate, and precise, with acceptable linearity within the calibration ranges. No significant variations were observed when different sources of both human and rat hair were used. The animal study demonstrated that JWH-073 N-COOH M was the major metabolite of JWH-073 in rat hair, and hair pigmentation did not have a significant effect on incorporation of JWH-073 and its metabolites into hair. In the analysis of 18 authentic hair samples, only JWH-018, JWH-018 N-5-OH M, and JWH-073 were detected, with wide variation in concentrations. 相似文献
10.
The carbon-13 nmr spectral assignments oi cocaine, O-benzoylecgonine, ecgonine, norcocaine, O-benzylnorecgonine, norecgonine, and N-allylnorcocaine were made. The assignments were primarily based on the correlation of substituent effects within series and selective proton irradiation studies. 相似文献
11.
The application of reversed-phase high-performance liquid chromatography to the measurement of benzoylecgonine and cocaine in urine is described. Following a simple extraction and clean-up procedure, chromatography is performed using a column containing an octadecylsilica coated packing, elution with 17% acetonitrile in pH 2.7 phosphate buffer and ultraviolet detection at 200 or 235 nm. The detection limit is ca.0.1 microgram of drug per ml urine, and using the ethyl ester of benzoylecgonine as an internal standard, benzoylecgonine and cocaine are quantified with coefficients of variation of 7.0 and 2.8%, respectively. The procedure has been applied to urines from subjects receiving intranasal cocaine, and compared to the enzyme multiplied immunoassay technique. The chromatography procedure also permits the separation of norcocaine and benzoylnorecgonine. 相似文献
12.
13.
Lowri de Jager 《Analytica chimica acta》2002,458(2):311-320
Hollow fiber membrane solvent microextraction (HFMSME) has been applied as a simple and efficient means of sample preparation for the screening of drugs of abuse in saliva. Extraction of cocaine and its metabolites from a 2 ml saliva solution was achieved in 10 min. This was followed by fast GC separation allowing complete analysis to be achieved in 15 min. Using HFMSME, detection limits ranged between 6 and 28 ng ml−1 with average relative standard deviations of 9.0%. The effect of the presence of various foodstuffs was also investigated. 相似文献
14.
Breath has been investigated as an alternative matrix for detecting recent cocaine intake; however, there are no controlled cocaine administration studies that investigated the drug’s disposition into breath. Breath was collected from 10 healthy adult cocaine users by asking them to breathe into a SensAbues device for 3 min before and up to 22 h following 25 mg intravenous (IV) cocaine dosing on days 1, 5, and 10, and assayed with a validated liquid chromatography-high-resolution mass spectrometry (LC-HRMS) method to quantify breath cocaine, benzoylecgonine (BE), ecgonine methyl ester (EME), and norcocaine. The assay was linear from 25 to 1,000 pg/filter, extraction efficiencies were 83.6–126 %, intra- and inter-assay imprecision was <10.6 %, and bias was between ?8.5 and 16.8 %. No endogenous or exogenous interferences were observed for more than 75 tested. Analytes were generally stable under short-term storage conditions. Ion suppression was less than 46 %. Of breath specimens collected after controlled cocaine administration, 2.6 % were positive for cocaine (26.1–66 pg/filter, 1–9.5 h), 0.72 % BE (83.3–151 pg/filter, 6.5–12.5 h), and 0.72 % EME (50–69.1 pg/filter, 6.5–12.5 h); norcocaine was not detected. Methanolic extraction of the devices themselves, after filters were removed, yielded 19.2 % positive cocaine tests (25.2–36.4 pg/device, 10 min–22 h) and 4.3 % positive BE tests (26.4–93.7 pg/device, 10 min–22 h), explaining differences between the two extraction techniques. These results suggest that the device reflects the drug in oral fluid as well as lung microparticles, while the filter reflects only drug-laden microparticles. A sensitive and specific method for cocaine, BE, EME, and norcocaine quantification in breath was developed and validated. Cocaine in breath identifies recent cocaine ingestion, but its absence does not preclude recent use. 相似文献
15.
A simple, quick and inexpensive screening method for cocaine and cocaine metabolites has been developed. Drug extraction was achieved using the relatively new technique of solvent microextraction (SME). Complete analysis is achieved in 13 min, using, a 6-min extraction with a 2-microl drop followed by separation on a gas chromatograph. The developed procedure was tested as a screening method for cocaine and cocaine metabolites in spiked urine samples. Using SME, concentrations as low as 0.125 microg ml(-1) of cocaine, ecgonine methyl ester, cocaethylene and anhydroecgonine methyl ester were measurable with relative standard deviation values averaging 9.0%. 相似文献
16.
The reduced form of vitamin B12 [cob(I)alamin] is known to be a supernucleophile, with the ability to react 10(5) times faster than standard nucleophiles. Procedures have been developed where cob(I)alamin is used as an analytical tool for the trapping of electrophilically reactive compounds. In the present work, a sensitive and accurate method for determination of reactive metabolites produced in vitro has been developed and validated. Diepoxybutane (DEB), a metabolite of 1,3-butadiene, was used as a model compound. The intermediate precursor 1,2-epoxybutene (EB) was incubated in a mouse liver S9 metabolic system and the formation of DEB was studied. Samples were taken at different times from the incubation mixture and added to the cob(I)alamin. The alkyl-cobalamins (alkyl-Cbl) formed were directly analysed by a miniaturized LC-MS/MS method and column switching. The assay was linear over the concentration range of 1.5-500 microM with acceptable precision and accuracy. 相似文献
17.
18.
We have employed a high-sensitivity on-line preconcentration method, cation-selective exhaustive injection (CSEI) and sweeping MEKC, for the analysis of cocaine, benzoylecgonine, norcocaine, and cocaethylene. We monitored the effects of several of the CSEI-sweeping-MEKC parameters - including the pH, the concentrations of SDS and organic modifier, the injection length of the high-conductivity buffer, and the injection time of the sample - to optimize the separation process. The optimal BGE was 100 mM phosphoric acid (pH 1.8) containing 75 mM SDS with 10% 2-propanol and 10% tetrahydrofuran as the organic modifier. In addition, electrokinetic injection of the sample at 15 kV for 900 s provided both high separation efficiency and enhanced sweeping sensitivity. The sensitivity enhancements for cocaine, norcocaine, and cocaethylene ranged from 2.06 x 10(4) to 3.96 x 10(4); for benzoylecgonine it was 1.75 x 10(3); the coefficients of determination exceeded 0.9958. The LODs, based on an S/N ratio of 3:1, of sweeping-MEKC ranged from 33.5 to 52.8 ng/mL; in contrast, when using CSEI-sweeping-MEKC the sensitivity increased to range from 29.7 to 236 pg/mL. Under the optimal conditions, we analyzed cocaine in a human urine sample prepared using off-line SPE to minimize the influence of the matrix. The recovery of the SPE efficiency was satisfactory (ca. 74.9-87.6%). Our experimental results suggest that, under the optimal conditions, the CSEI-sweeping-MEKC method can be used to determine cocaine and its metabolites with high sensitivity in human urine. 相似文献
19.
Vincent Janssens Christophe Block Guy Van Assche Bruno Van Mele Peter Van Puyvelde 《Journal of Thermal Analysis and Calorimetry》2009,98(3):675-681
A newly developed hyphenated technique is presented that combines an existing rheometer and differential scanning calorimeter
(DSC) into a single experimental setup. Through the development of a fixation accessory inside the cell of the calorimeter
and the introduction of an add-on unit for the rheometer, the simultaneous calorimetric and rheological measurement inside
the well-controlled thermal environment of a Tzero™ DSC cell opens new experimental possibilities. The evolution of thermal
and flow properties of a material can be simultaneously monitored during steady or oscillatory shear flow and regular or modulated
temperature DSC measurements. The technique offers interesting opportunities for the investigation of flow-induced transitions,
such as crystallization or phase separation, and provides a possibility for high-throughput screening of materials. The signal
quality of the novel technique in comparison to the stand-alone techniques is demonstrated by the evaluation of the calibration
factors and by measurements on standard materials. Finally, combined rheological and calorimetric melting and crystallization
experiments on polycaprolacton are performed. 相似文献
20.
Barroso M Dias M Vieira DN Queiroz JA López-Rivadulla M 《Rapid communications in mass spectrometry : RCM》2008,22(20):3320-3326
A new, simple and rapid procedure has been developed and validated for the determination of cocaine and its main metabolite, benzoylecgonine, in human hair samples. After extraction from within the hair matrix by a mixture of methanol/hydrochloric acid (2:1) at 65 degrees C for 3 h, and sample cleanup by mixed-mode solid-phase extraction (SPE), the extracts were analyzed by gas chromatography/mass spectrometry (GC/MS), after derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide with 5% chlorotrimethylsilane. Using a sample size of only 20 mg of hair, limits of detection (LODs) and quantitation (LOQs) were, respectively, 20 and 50 pg/mg for cocaine, and 15 and 50 pg/mg for benzoylecgonine, achieving the cut-off values proposed by the Society of Hair Testing for the analysis of these compounds in hair. The method was found to be linear (weighing factor of 1/x) between the LOQ and 20 ng/mg for both compounds, with correlation coefficients ranging from 0.9974 to 0.9996 for cocaine; and from 0.9981 to 0.9994 for benzoylecgonine. Intra- and interday precision and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The sample cleanup step presented a mean absolute recovery greater than 90% for both compounds. The developed method may be useful in forensic toxicology laboratories for the analysis of cocaine and benzoylecgonine in hair samples, taking into account its speed (only 3 h are required for the extraction of the analytes from within the matrix, whereas 5 h or even overnight extractions have been reported) and the low limits achieved (using a single quadrupole mass spectrometer, which is available in most laboratories). 相似文献