首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
2.
Based on several alerts from European countries over the last years concerning spices, we have been encouraged to establish an accurate method for the determination of dyes, aflatoxins and pesticides in various types of spices using reversed-phase (RP) liquid chromatography–tandem mass spectrometry interfaced with electrospray (LC–ESI–MS/MS). A simple sample treatment procedure entailing the use of an extraction step with acetonitrile without further cleanup has been developed. A C18 column with an aqueous ammonium formate/methanol mixture as the mobile phase was used, and gradient elution was performed. Mass spectral acquisition was done in positive ion mode by applying multiple reaction monitoring of at least two fragmentation transitions per compound to provide a high degree of selectivity. The method was in-house validated in terms of linearity, sensitivity, repeatability, recovery and selectivity on six kinds of spices. Satisfactory results in the majority of the cases were obtained for all analytes and matrices, with practical limits of quantitation acceptable for routine monitoring purposes. Extraction recoveries for most of the compounds ranged from 60% to 140% at spiking levels of 0.05 and 0.5 mg kg−1. The applicability of the method for the simultaneous determination of dyes, aflatoxins and pesticides in several types of spices was demonstrated, and the method successfully applied to a limited number of products from the local market.  相似文献   

3.
4.
5.
An LC–MS/MS multi-method for the simultaneous determination of the structurally different and frequently used cytostatic drugs 5-fluorouracil, gemcitabine, methotrexate, cyclophosphamide, ifosfamide, etoposide, docetaxel and paclitaxel was developed and validated. In order to perform repeated ambient monitoring in 130 German pharmacies all steps of the monitoring procedure such as sample collection, transport, storage, sample preparation and HPLC–MS/MS analysis have been adapted and optimised. Thus sensitivity and reliability as well as sample throughput were increased. The final method consists of wipe sampling from 900?cm2 surfaces and extraction of the tissues with an aqueous pH 3 solution. The limits of quantification range from 3.7 to 37?pg?cm?2. Validation showed that sampling via the individual pharmacy personnel does not affect the overall results. Recovery rates below 70% were observed on rough surfaces for the taxanes docetaxel and paclitaxel. Likewise, neither the storage nor the shipping conditions affected the results significantly.  相似文献   

6.
Artificial sweeteners are widely used as substitutes for sugar. The sweeteners are generally considered safe, however their whereabouts during pregnancy and lactation and the effect on child development are poorly explored. There is a need for new tools to measure these substances during pregnancy and lactation. Here, we describe the development and validation of a sensitive liquid chromatography–tandem mass spectrometry method for the simultaneous quantification of acesulfame, cyclamate, saccharin and sucralose in human plasma, umbilical cord blood, amniotic fluid and breast milk. The samples were prepared by protein precipitation and separated on a Luna Omega Polar C18 column (2.1 × 50 mm, 1.6 μm). Electrospray ionization in negative mode and multiple reaction monitoring were used to monitor the ion transitions. The validated concentration ranges were from 1 to 500 ng/ml (10–500 ng/ml for sucralose). Interassay precisions were all ≤15% and the accuracies were within ±15%. Stability, linearity, dilution integrity, carryover and recovery were also examined and satisfied the validation criteria. Finally, this analytical method was successfully applied on spiked samples of plasma, umbilical cord blood, amniotic fluid and breast milk, proving its suitability for use in clinical studies on artificial sweeteners, including during pregnancy and lactation.  相似文献   

7.
Amlexanox, an anti-inflammatory and anti-allergic agent, has been widely used clinically for the treatment of canker sores, asthma, and allergic rhinitis. Recently, amlexanox has received considerable attention in curing nonalcoholic fatty liver diseases and hepatitis virus infection. Herein, we first established a sensitive high-performance liquid chromatography-tandem mass spectrum (LC–MS/MS) method for the determination of amlexanox in rat plasma. Propranolol was used as the internal standard (IS). Using a simple protein precipitation method, the amlexanox and IS were separated with Capcell Pak C18 column (2.0 × 50 mm, 5 μm) and eluted with water and acetonitrile each containing 0.1% formic acid using gradient elution condition at a flow rate of 0.4 mL·min−1. Amlexanox and IS were detected by a triple quadrupole mass in multiple reactive monitoring (MRM) under the transitions of m/z 299.2 → 281.2 and m/z 259.9 → 116.1 with positive electrospray ionization, respectively. The calibration curves of amlexanox were established with the range of 50 to 2000 ng·mL−1 (r2 > 0.99). The validation method consisted of selectivity, accuracy, precision, carryover effect, matrix effect, recovery, dilution effect, and stability. The fully validated method was successfully applied to the pharmacokinetic study of amlexanox in Wistar rats.  相似文献   

8.
A sensitive and specific liquid chromatography tandem mass spectrometric (LC–MS/MS) method that enables the simultaneous quantification of probe substrates and metabolites of cytochrome P450 (CYP) enzymes was developed and validated. These substrates (metabolites)—coumarin (7-hydroxycoumarin), tolbutamide (4-hydroxytolbutamide), S-mephenytoin (4-hydroxymephenytoin), dextromethorphan (dextrorphan), and testosterone (6β-hydroxytestosterone)—were utilized as markers for the activities of the major human CYP enzymes CYP2A6, CYP2C9, CYP2C19, CYP2D6, and CYP3A4, respectively. Analytes were separated on Kinetex C18 column (2.1 × 50 mm, 5 μm) using a binary gradient mobile phase of 0.1% formic acid in water and 0.1% formic acid in acetonitrile. Metabolites were detected and quantified by MS using multiple reaction monitoring at m/z 163 → 107.2 for 7-hydroxycoumarin, m/z 235 → 150.1 for 4-hydroxymephenytoin, m/z 287 → 171 for 4-hydroxytolbutamide, m/z 258 → 157.1 for dextrorphan, m/z 305 → 269 for 6β-hydroxytestosterone, and m/z 237 → 194 for the internal standard. The assay exhibited good linearity over a range of 10–500 ng/mL with acceptable accuracy and precision criteria. As a proof of concept, the developed cocktail assay was successfully used to examine the potential impact of catechin on the activity of the major rat liver CYP enzymes.  相似文献   

9.
Polyphyllin II, a major steroidal saponin isolated from Paris polyphylla, exhibits significant pharmacological activities. In this study, a rapid and sensitive liquid chromatography–tandem mass spectrometry method was established and validated for the determination of polyphyllin II in plasma. Polyphyllin II and polyphyllin VII (internal standard) were separated on a Waters Acquity™ HSS T3 column and the mass analysis was performed in a triple quadrupole mass spectrometer equipped with an electrospray ionization ion source. Results showed that the method was sensitive (lower limit of quantitation 0.5 ng/ml), precise (<15%) and linear in the range of 0.5–500 ng/ml (r > 0.99). Interestingly, the sensitivity in current study was ~10 times higher than that in the previous study. The results of the pharmacokinetic study of polyphyllin II in rats suggested that polyphyllin II was poorly absorbed into blood and reached its highest concentration at ~3.67–5.00 h with a slow elimination half-life of 8.34–13.37 h. The bioavailability was 6.1–8.2%. The results indicated that the absorption of polyphyllin II may primarily occur via passive diffusion in rats. This study provides valuable information that can be used as a reference for the pharmacokinetic investigation of other steroidal saponins.  相似文献   

10.
A novel, simple and sensitive method for the determination of Lusutrombopag in rat plasma using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated. The determination was performed on an API4000 triple quadrupole mass spectrometry in the multiple reaction monitoring mode using the respective [M+H]+ ions m/z 593.1 → 272.3 for Lusutrombopag. The limit of detection was 0.5 ng/mL, and the lower limit of quantification was 2.0 ng/mL in rat plasma. Good linearity was obtained over the range of 2.0–150.0 ng/mL and the correlation coefficient was found to be 0.9998. The intra and inter-day precisions were found to be 3.8–6.9% and 6.8–10.5%, respectively. The intra and inter-day accuracy derived from QC samples was found to be 2.5–4.9% and 5.5–7.2%, respectively. The analyte was stable under various conditions (at room temperature, during freeze-thaw, in the autosampler and under deep-freeze conditions). The F-test and t-test at 95% confidence level were subjected on data for statistical analysis. The developed method was successfully applied to the pharmacokinetic study in rats.  相似文献   

11.
The present work describes a fully automated method based on online solid phase extraction–liquid chromatography–tandem mass spectrometry for the determination of different classes of pesticides, including acidic and polar pesticides and six thiamethoxam metabolites. Sample preconcentration was performed by extracting 4 mL of the sample with a single styrene-divinylbenzene polymer. Elution of the compounds was done within the high performance liquid chromatography gradient and tandem mass spectrometry determination was performed in the selected reaction monitoring mode, by recording 1–3 transitions per compound. The overall pretreatment and analysis time per sample was less than 15 min. Method validation was performed in drinking, ground and surface water. For nearly all compounds a recovery between 70% and 120% could be achieved. The limit of detection ranges from 1.2 to 18 ng/L in drinking water and 3.0 to 23 ng/L in ground and surface water. The correlation coefficients for a calibration range of 0.05–2 µg/L are between 0.9915 and 0.9999. The limit of quantification (LOQ) for all compounds lies below the required limit of 0.1 µg/L, to fulfil the Council Directive 98/83/EC. Most of the compounds easily reach an LOQ below 0.05 µg/L.  相似文献   

12.
13.
A high-performance liquid chromatography tandem mass spectrometric method was developed and validated for cenicriviroc (CVC) quantification in human plasma and cerebrospinal fluid (CSF). The method involved precipitation with acetonitrile and injecting supernatants onto the column. Separation was achieved on an XBridge C18 column with a gradient elution of 0.1% formic acid in water and acetonitrile. Analyte detection was conducted in positive ion mode using selected reaction monitoring. The m/z transitions were: CVC (697.3 → 574.3) and CVC-d7 (704.4 → 574.3). Calibration curve ranged from 5 to 1000 ng/mL for plasma and from 0.241 to 15.0 ng/mL for CSF. The intra- and inter-day precision and accuracy were <15% for both plasma and CSF across four different concentrations. CVC recovery from plasma and artificial CSF was >90%. The method was utilized for the measurement of patients’ plasma and CSF samples taking a dose of 50, 150 and 300 mg q.d.  相似文献   

14.
This contribution presents a simple, rapid and sensitive method for determining the residues of a wide variety of coccidiostats in eggs and chicken. Fourteen target analytes from different classes with different polarities were simultaneously extracted from eggs and chicken using acetonitrile. Sample extracts were further concentrated and directly injected into a liquid chromatography system based on a C-18 column separation and acquired using electrospray ionization tandem mass spectrometry in the positive or negative mode. Recoveries based on matrix-fortified calibrations for eggs and chickens ranged from 78.0 to 125.2%. The limits of quantification for all analytes ranged from 0.1 to 0.2 μg kg?1.  相似文献   

15.
16.
The present study describes forced degradation of benidipine (BEN) as per  Q1A (R2) and Q1B guidelines of the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use. BEN degraded under hydrolysis (neutral, acidic, and alkaline), hydrogen peroxide induced oxidation, and UV light mediated photolytic degradation. A total of 14 degradation products (DPs) were found in all degradation studies, comprising 4 hydrolytic DPs, 8 oxidative DPs, and 4 photolytic DPs. A selective stability-indicating method was developed using an XBridge BEH C18 column with gradient elution program consisting of ammonium acetate (10 mM, 4.8 pH, acetic acid) and acetonitrile. The flow rate was maintained at 1 ml min−1. All DPs were separated well using the developed HPLC method and were characterized using LC–MS/MS data. As this method is effective in identifying and separating BEN and its DPs with sufficient resolution, it can be used in laboratories for quality control of drugs in daily routine analysis and stability studies.  相似文献   

17.
18.
Sirolimus is used on patients after solid organ transplantation and on lymphangioleiomyomatosis (LAM) patients, and therapeutic drug monitoring is required in clinical practice. We have previously reported an accurate method for quantitative determination of sirolimus, but its sample preparation step was complicated. In this study, we developed a modified liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI–MS/MS) method for sirolimus quantification. A supported liquid extraction cartridge was used to purify sirolimus from whole blood and ion suppression was mostly prevented. The validation results met the acceptance criteria. This method was compared with the antigen conjugated magnetic immunoassay (ACMIA) and our previously reported method, using whole blood samples from LAM patients. Comparison of the Bland–Altman plots of the currently developed method and the previous method revealed no significant difference between the two methods (mean bias, −2.02%; 95% CI, −7.81–3.78). The values obtained using ACMIA were significantly higher than those obtained using the current method by 13.87% (95% CI, 6.49–21.25) owing to cross-reactivity. The degrees of cross reactivities in LAM patients and in organ transplant patients were similar, and our LC/ESI–MS/MS method precisely measured the blood concentrations of sirolimus.  相似文献   

19.
Remdesivir (RDV), a phosphoramidate prodrug, has broad-spectrum antiviral activity. It is the first antiviral drug approved by the US Food and Drug Administration (FDA) for the treatment of COVID-19. Remdesivir is rapidly metabolized in the body to produce derivatives: alanine metabolite (RM-442) and RDV C-nucleoside (RN). Here, the phosphatase inhibitor PhosSTOP and carboxylesterase inhibitor 5,5′-dithiobis-2-nitrobenzoic acid were used to improve stability of RDV in mouse blood. We developed a rapid and sensitive LC–MS/MS method to simultaneously quantify RDV, RM-442 and RN in mouse blood. Chromatographic separation was achieved by gradient elution on an Acquity HSS T3 column. The run time was 3.2 min. The linearity ranges of the analytes were 0.5–1,000 ng/ml for RDV and 5–10,000 ng/ml for both RM-442 and RN. The method had an acceptable precision (RSD < 8.4% for RDV, RSD < 10.7% for RM-442 and RSD < 7.2% for RN) and accuracy (91.0–106.3% for RDV, 92.5–98.6% for RM-442 and 87.5–98.4% for RN). This method was successfully applied to analyze RDV, RM-442 and RN in the blood of normal and diabetic nephropathy DBA/2 J mice after intravenous injection of RDV at 20 mg/kg. The area under the concentration–time curve of RN between the normal and diabetic nephropathy mice showed a significant difference (P < 0.01).  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号