首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
张含智  李凤  康经武 《色谱》2023,41(2):160-167
毛细管电泳-质谱联用技术具有分离效率高、检测灵敏度高、样品消耗量少,可同时提供样品的结构信息等优点,成为复杂样品分离分析的强有力工具。但是,毛细管电泳与质谱联用的接口技术依然未能很好的解决。为了拓展我们发展的金箔包裹的毛细管电泳分离柱尖端直接作为喷雾电极和无鞘流质谱接口的应用,本文报道了用无鞘流接口毛细管电泳-电喷雾质谱联用(CE-ESI-MS)分析5种酪氨酸激酶抑制剂(舒尼替尼、甲磺酸伊马替尼、吉非替尼、达沙替尼、埃罗替尼)的研究结果。这种接口集分离与电喷雾离子化于一根毛细管中,制作简单,成本低廉,且可批量制作。实验发现采用非水毛细管电泳分离模式不仅可以对5种酪氨酸激酶抑制剂实现基线分离,而且可以获得稳定的质谱信号。考察了电解质溶液组成对分离效果的影响,得到优化的背景电解质组成,即含2%(v/v)乙酸及5 mmol/L乙酸铵的乙腈-甲醇(80∶20, v/v)混合溶剂。在优化的条件下,5种激酶抑制剂可以得到基线分离,无鞘接口也可以长时间保持稳定的电喷雾,分析物的保留时间日内、日间重复性(RSD值)分别小于0.5%和0.8%,接口批次间的RSD值小于2.6%。与水相分离条件下的CE-MS对比,非水相条件下的5种酪氨酸激酶抑制剂的分离柱效更高,检测灵敏度更高,绝对检出限达到amol级。此外,采用无鞘流CE-MS分析了各类有机酸(千层纸素A、丹酚酸C和迷迭香酸)和脂溶性的大环内酯类抗生素(阿奇霉素、红霉素和环孢素A),均可以获得良好的分离效果和质谱检测结果。  相似文献   

2.
Summary Sonic spray ionization (SSI) was compared with atmospheric pressure chemical ionization (APCI) as an interface for liquid chromatography (LC)-mass spectrometry (MS) for the analysis of some local anesthetics. Peaks at [M+H]+ constituted the base peaks for all compounds by both SSI and APCI, except for prilocaine. The sensitivities by SSI for tetracaine, benzoxinate, dibucaine, bupivacaine and mepivacaine were 4–16 times higher than those by APCI; those by SSI for procaine and lidocaine were equivalent to those by APCI. Only for prilocaine was the sensitivity by SSI two times lower than that by APCI. In view of the higher sensitivities obtained for many local anesthetics by SSI, we established a detailed procedure for the assay of these drugs in human plasma and urine by LC-MS with SSI in combination with a diol-bonded silica gel HPLC column that enabled direct injection of crude biological samples without complicated pretreatment. The recoveries, sensitivities, accuracies and precisions were found satisfactory to quantitate them at their therapeutic levels.  相似文献   

3.
A new method for the simultaneous separation of cocaine and four metabolites in urine by CE-ESI-MS via a pressurized nanoliquid junction interface was developed. The resolution of cocaine, cocaethylene, benzoylecgonine, norcocaine, and ecgonine methyl ester was achieved in a polyvinyl-alcohol-coated capillary with 75 μm id × 50 cm total length, using a 15 mM ammonium formate electrolyte solution (pH 9.5) in less than 15 min. In addition, to enhance sensitivity, a field-amplified sample injection (FASI) was evaluated in terms of injection time and sample solvent composition. The limits of detection achieved with the FASI method ranged from 1.5 to 10 ng/mL for all the compounds. The detection of the studied compounds was performed using an ion-trap mass spectrometer in a positive ionization mode. A mixture of methanol:water (80:20 v/v) containing 0.1% v/v of formic acid was employed as spray liquid and delivered at ~200 nL/min. Under optimal CE-MS conditions, linearity was assessed in the concentration range of interest for all analytes with correlation coefficients r2 ≥ 0.9913. Intra- and inter-day precision provided a relative standard deviation lower than 1.54% for migration times and lower than 12.15% for peak areas. Finally, urine samples, spiked with the standard mixture, were extracted using a solid-phase extraction procedure and injected under FASI conditions, providing recoveries from 80% to 94% for all analytes.  相似文献   

4.
Thin-layer chromatography-mass spectrometry including both direct and scanning thin-layer chromatography-liquid secondary ion mass spectrometry, has been used to obtain good separation and good mass spectra of non-volatile and thermally unstable mixtures. The methods are very simple, useful and easy to perform, and they can overcome the problems associated with indirect and direct coupling of liquid chromatography and mass spectrometry. Scanning thin-layer chromatography-liquid secondary ion mass spectrometry can be carried out like gas chromatography-mass spectrometry, and gives good quality chromatograms and mass spectra. These methods were used to analyse drug metabolites and mixtures of other organic compounds.  相似文献   

5.
6.
Cai Z  Fung EN  Sinhababu AK 《Electrophoresis》2003,24(18):3160-3164
A capillary electrophoresis-ion trap mass spectrometry method with a time-segment program was developed to simultaneously analyze Ziagen and its phosphorylated metabolites such as carbovir monophosphate, carbovir diphosphate, and carbovir triphosphate. By using the time-segment program, the positively charged nucleoside analog and negatively charged nucleotides were separated and detected in a single electrophoretic run. The limits of detection were less than 2 micro M for all of the analytes. Calibration curves of the compounds showed excellent linearity over the range of 2-100 micro M. The capability of the method was demonstrated by analyzing Ziagen and its phosphorylated metabolites that were spiked in cellular extracts of human peripheral blood mononuclear cells at 20 micro M levels. Some endogenous nucleotides such as adenosine 5'-triphosphate, adenosine 5'-diphosphate, and adenosine 5'-monophosphate, were also detected in the cellular extracts.  相似文献   

7.
 The performance of two liquid chromatography-mass spectrometry (LC/MS) interfacing techniques, thermospray (TSP) and atmospheric pressure chemical ionization (APCI), for the analysis of benzo[a]pyrene (BaP) metabolites (hydroxy, epoxy and quinone derivatives) was compared. Interface and detection parameters such as source temperature, eluent composition or flow rate were optimized using negative ion mode. In TSP, the main ions are mostly [M]-, [M−H2O]- or [M+CH3COO]-, whereas APCI gives mainly the [M]- and [M−H]- ions. Quantification was carried out by flow injection. Calibration graphs were linear in the range of 10 ng to 1000 ng in TSP and 0.1 ng to 10 ng in APCI. Detection limits were in the range of 1 ng to 20 ng in TSP and 0.002 ng to 0.2 ng in APCI. The presence of BaP-1,6-dione, BaP-3,6-dione, and BaP-6,12-dione was confirmed in environmental samples of air particulate matter. Received: 6 January 1997/Accepted: 18 April 1997  相似文献   

8.
 The performance of two liquid chromatography-mass spectrometry (LC/MS) interfacing techniques, thermospray (TSP) and atmospheric pressure chemical ionization (APCI), for the analysis of benzo[a]pyrene (BaP) metabolites (hydroxy, epoxy and quinone derivatives) was compared. Interface and detection parameters such as source temperature, eluent composition or flow rate were optimized using negative ion mode. In TSP, the main ions are mostly [M]-, [M−H2O]- or [M+CH3COO]-, whereas APCI gives mainly the [M]- and [M−H]- ions. Quantification was carried out by flow injection. Calibration graphs were linear in the range of 10 ng to 1000 ng in TSP and 0.1 ng to 10 ng in APCI. Detection limits were in the range of 1 ng to 20 ng in TSP and 0.002 ng to 0.2 ng in APCI. The presence of BaP-1,6-dione, BaP-3,6-dione, and BaP-6,12-dione was confirmed in environmental samples of air particulate matter. Received: 6 January 1997/Accepted: 18 April 1997  相似文献   

9.
A comprehensive approach for the separation and identification of components in a traditional Chinese medicine Lobelia chinensis Lour. was developed using 2D-HPLC coupled with an online photodiode array (PDA) detector and a mass spectrometer. The extract of L. chinensis Lour. was separated on a CN column in the first-dimensional HPLC, and then each of the collected fractions was further separated on an ODS column followed by an online PDA detector. After separation in the two different chromatographic modes, the eluents were delivered to a quadrupole mass spectrometer equipped with a multimode ion source of an ESI and an atmospheric pressure chemical ionization (ESI/APCI). At least 536 components in L. chinensis Lour. extract were detected and 6 of them were identified as apigenin 7-O-rutinoside, luteolin, lobetyolinin, lobetyolin, diosmin, and linarin, respectively, according to their UV spectrum and mass spectrum. The results demonstrated the powerful resolution, high peak capacity, as well as the identification capability of the 2D-HPLC combined with PDA and ESI/APCI-MS for the analyses of complex samples.  相似文献   

10.
A quantitative liquid chromatography/ion trap mass spectrometry method for the simultaneous determination of paclitaxel, 6alpha-hydroxypaclitaxel and p-3'-hydroxypaclitaxel in human plasma has been developed and validated. 6alpha-,p-3'-Dihydroxypaclitaxel was also quantified using paclitaxel as a reference and docetaxel as an internal standard. The substances were extracted from 0.500 mL plasma using solid-phase extraction. The elution was performed with acetonitrile and the samples were reconstituted in the mobile phase. Isocratic high-performance liquid chromatography analysis was performed by injecting 50 microL of reconstituted material onto a 100 x 3.00 mm C12 column with a methanol:1% trifluoroacetic acid/ammonium trifluoroacetate in H(2)O 70:30 mobile phase at 350 microL/min. The [M+H](+) ions generated in the sonic spray ionization interface were isolated and fragmented using two serial mass spectrometric methods: one for paclitaxel (transition 854 --> 569 & 551) and the dihydroxymetabolite (transition 886 --> 585 & 567) and one for the hydroxy metabolites (transition 870 --> 585 & 567; transition 870 --> 569 & 551) and docetaxel ([M+Na](+), transition 830 --> 550). Calibration curves were created ranging between 0.5 and 7500 ng/mL for paclitaxel, 0.5 and 750 ng/mL for 6alpha-hydroxypaclitaxel, and 0.5 and 400 ng/mL for p-3'-hydroxypaclitaxel. Adduct ion formation was noted and investigated during method development and controlled by mobile phase optimization. In conclusion, a sensitive method for simultaneous quantification of paclitaxel and its metabolites suitable for analysis in clinical studies was obtained.  相似文献   

11.
In this study, we use an ion funnel (IF) at ambient pressure to enhance the sensitivity of secondary electrospray ionization (SESI). Atenolol, salbutamol and cocaine as test compounds are delivered to the SESI interface in the gas phase and are charged with three nano electrosprays. In our experiments, we show that the compounds can be detected at concentrations in the low pptv range, which is an increase of two orders of magnitude compared with the results without the IF. With a standard SESI interface, the compounds could not be detected at all. With the use of the SESI IF interface for the headspace analysis of bananas and limes, we can detect many more compounds and at higher intensities than with a standard SESI interface. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
13.
Benzodiazepines, namely flunitrazepam and its three major metabolites, were successfully separated by microemulsion electrokinetic chromatography. Separation was achieved using an untreated fused-silica capillary (48 cm (effective length 40 cm) x 50 num) at 25 kV; detection was performed by UV at 220 nm. The microemulsion system consisted of 70 mM octane, 800 mM 1-butanol, 80 mM sodium dodecyl sulfate (SDS) and 10 mM borate buffer, pH 9. Very high efficiencies (up to 400 000 plates) and resolution better than 3 were achieved. Since this technique is not compatible with mass spectrometry (MS) detection, a capillary electrochromatographic (CEC) method was developed to separate flunitrazepam and its metabolites. The effects of mobile phase composition and pH as well as voltage and temperature were systematically investigated. The optimized CEC method allowed the baseline separation of the investigated compounds. For the on-line coupling of CEC with electrospray ionization-mass spectrometry, the column was connected to a void fused-silica capillary using a Teflon connection. This configuration was found efficient and suitable for hyphenation of commercial CEC and MS instrumentation using commercially available CEC columns.  相似文献   

14.
建立了原多甲藻酸毒素(azaspiracids,AZAs)及其代谢产物的液相色谱-串联质谱检测方法,考察了目标代谢产物检测方法和非目标多离子检测方法,将二级质谱图与标准品谱库进行比对,从而获得高精准定性。通过对产毒藻、蓄积代谢实验样品和实际阳性样品综合分析,共检出11种AZAs,其中包括AZA-2,3,6,11,12,16,17,28和36,以及AZAs的谷胱甘肽结合型代谢产物。结果发现,目标代谢产物检测法可无偏差地筛出常规代谢物,而且对低浓度代谢产物表现出更佳的响应。本方法重现性好,数据分析简单,对操作人员的专业要求不高,更适合AZAs的监控要求。  相似文献   

15.
The anticancer drug capecitabine and its metabolites [including the active metabolite 5‐fluorouracil (5‐FU)] display high pharmacokinetic inter‐patient variability. Such variability, which may lead to treatment failure or toxicity, could need drug concentration measurement to individualize dosing regimen. However, usual assay methods are often long and fastidious. A simultaneous and cost‐effective method was thus developed for the determination of the concentrations of these compounds in human plasma. Compounds were extracted via a classic liquid–liquid extraction. Chromatographic analysis was performed on a C18 reverse phase column with detection by atmosphere pressure chemical ionization LC‐MS/MS. Our method allows a good chromatographic separation of the compounds and was fully validated following Food and Drug Administration (FDA) recommendations (good selectivity, no carry‐over, linearity of the calibration curves without weighting, deviations from nominal concentrations of standard samples lower than 15%, intra‐ and inter‐assay precision and accuracy lower than 15%). Recovery and stability were also acceptable following the FDA guidelines. A matrix effect impairing the determination of 5‐FU was avoided by using a stable isotopic derivative of 5‐FU as internal standard. Interestingly, this method allows detection of TetraHydroUridine, an inhibitor of ex vivo degradation of metabolites, which is essential for the stability, the adequate conditioning of blood samples and for good laboratory practice, essential in routine determination. This method seems usable to routinely determine concentrations of capecitabine and its metabolites in blood and may be helpful in further studies aiming at performing therapeutic drug monitoring. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
Conditions of the simultaneous isolation of various types of zolpidem metabolites from samples of real urine by solid-phase extraction have been optimized. Various derivatives of zolpidem hydroxy- and carboxy-metabolites were obtained; their mass-spectral and gas-chromatographic characteristics have been studied. The results ensure the reliable identification of zolpidem metabolites by gas chromatography-mass spectrometry for chemical toxicological and forensic investigations.  相似文献   

17.
Four liquid chromatography/mass spectrometry (LC/MS) systems, equipped with single quadrupole, triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole time-of-flight (QqTOF) mass analyzers, were evaluated for the analysis of carbosulfan and its main transformation products. The comparison of quantitative aspects (sensitivity, precision and accuracy) was emphasized. Results showed that the triple quadrupole instrument reaches at least 20-fold higher sensitivity (LOD from 0.04 to 0.4 microg kg(-1)) compared to the single quadrupole (4-70 microg kg(-1)), the QIT (4-25 microg kg(-1)) and the QqTOF (4-23 microg kg(-1)) instruments. Recoveries were over 70% for all the analytes, except dibutylamine and 7-phenolcarbofuran. Repeatabilities (within-day) were slightly better by the single quadrupole (5-10%) and the QqQ (5-9%) than by the QIT (12-16%) and the QqTOF (9-16%). Both the QqTOF and QIT offer a linear dynamic range of two orders of magnitude whereas the single quadrupole and QqQ of, at least, three orders of magnitude. The method was applied to analyze carbosulfan field-treated orange samples, in which carbosulfan, carbofuran, 3-hydroxycarbofuran, and dibutylamine were found. As an example, the mean carbosulfan concentration was 20 +/- 0.6 microg kg(-1) measured by the QqQ, 22 +/- 1.2 microg kg(-1) by the single quadrupole, 25 +/- 2.8 microg kg(-1) by the QIT, and 20 +/- 1.8 microg kg(-1) by the QqTOF. Although the QqQ is more sensitive and precise, the mean values obtained by the four instruments are acceptable and comparable. The potential of each technique for the verification of the identity of residues detected in oranges is discussed using the concept of identification points.  相似文献   

18.
Organophosphate esters (OPEs) are chemical compounds incorporated into materials as flame‐proof and/or plasticizing agents. In this work, 13 non‐halogenated and 5 halogenated OPEs were studied. Their mass spectra were interpreted and compared in terms of fragmentation patterns and dominant ions via various ionization techniques [electron ionization (EI) and chemical ionization (CI) under vacuum and corona discharge atmospheric pressure chemical ionization (APCI)] on gas chromatography coupled to mass spectrometry (GC‐MS). The novelty of this paper relies on the investigation of APCI technique for the analysis of OPEs via favored protonation mechanism, where the mass spectra were mostly dominated by the quasi‐molecular ion [M + H]+. The EI mass spectra were dominated by ions such as [H4PO4]+, [M–R]+, [M–Cl]+, and [M–Br]+, and for some non‐halogenated aryl OPEs, [M]+● was also observed. The CI mass spectra in positive mode were dominated by [M + H]+ and sometimes by [M–R]+, while in negative mode, [M–R] and more particularly [X] and [X2]‐● were mainly observed for the halogenated OPEs. Both EI and APCI techniques showed promising results for further development of instrumental method operating in selective reaction monitoring mode. Instrumental detection limits by using APCI mode were 2.5 to 25 times lower than using EI mode for the non‐brominated OPEs, while they were determined at 50‐100 times lower by the APCI mode than by the EI mode, for the two brominated OPEs. The method was applied to fish samples, and monitored transitions by using APCI mode showed higher specificity but lower stability compared with EI mode. The sensitivity in terms of signal‐to‐noise ratio varying from one compound to another. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
This study compares different silylation procedures of zearalenone and its metabolites: alpha-zearalenol, beta-zearalenol, zearalanone, alpha-zearalanol and beta-zearalanol for gas chromatography-mass spectrometry (GC-MS) analysis. Four silylating agents among the most frequently used to derivatize polar organic compounds were tested: N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA), N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA), N,N-diethyltrimethylsilylamine (TMSDEA) and a commercial mixture of N,O-bis(trimethylsilyl)acetamide, trimethylchlorosilane and N-trimethylsilyimidazole. Previous studies showed that the addition of polar and/or basic solvents can significantly improve the yield of a reaction of derivatization. In this work, four solvents were tested: pyridine, dimethylformamide, acetonitrile and acetone. The influence of each solvent was studied as a function of the silylating agent/solvent ratio. The influences of the temperature and of the reaction time on the reaction yields were also evaluated. A GC-MS quantitation method associating methanol chemical ionization and selected ion storage with three ions was developed and successfully tested on a reconstituted sediment spiked in zearalenone and its metabolites.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号