共查询到20条相似文献,搜索用时 78 毫秒
1.
Capillary electrophoresis-mass spectrometry was applied to the separation of several anionic dyes containing copper(II), chromium(III), or cobalt(III) as part of the dye molecule. The dyes were separated using a 110 cm x 50 microm uncoated fused-silica capillary and a 5 mM ammonium acetate buffer (pH 9) containing 40% acetonitrile. Excellent separation efficiencies (N = 500,000 plates/column) and low detection limits of 20-50 pg (selected ion monitoring, S/N = 10) were achieved. Mass spectra were acquired at different cone voltages. At low cone voltages (low collision energies), sensitivity was maximized and the mass spectra contained only signals of the (multiply charged) molecular ions and low levels of sodium ion and proton adducts. At higher cone voltages, the 2:1 (ligand:metal) chromium and cobalt dyes showed losses of one of the two dye ligands, accompanied by a reduction of the metal. The copper dyes showed signals due to loss of SO2 and SO3-, but no release of metal. Azo cleavage, otherwise typical of azo dyes, was not observed with the metallized dyes. 相似文献
2.
Castro-Puyana M García-Ruiz C Cifuentes A Crego AL Marina ML 《Journal of chromatography. A》2006,1114(1):170-177
trans-Ketoconazole was identified and quantified as impurity of cis-ketoconazole, an antifungal compound, by capillary zone electrophoresis-electrospray-mass spectrometry (CZE-ESI-MS). The chirality of this impurity was demonstrated separating their enantiomers by adding heptakis-(2,3,6-tri-O-methyl)-beta-cyclodextrin to the separation buffer in capillary electrophoresis (CE) with UV detection. However, MS detection was hyphenated to the CE instrument for its identification. As both compounds are diastereomers, they have the same m/z values and are needed to be separated prior to the MS identification. A 0.4M ammonium formate separation buffer at pH 3.0 enabled the separation of the impurity from cis-ketoconazole. Under these conditions, the optimization of ESI-MS parameters (composition and flow of the sheath-liquid, drying temperature, drying gas flow, and capillary potential) was carried out to obtain the best MS sensitivity. CZE-ESI-MS optimized conditions enabled the identification of trans-ketoconazole as impurity of cis-ketoconazole. In addition, the quantitation of this impurity was achieved in different samples: cis-ketoconazole standard and three different pharmaceutical formulations (two tablets and one syrup) containing this standard. In all cases, percentages higher than 2.0 were determined for the impurity. According to ICH guidelines, these values required the identification and quantitation of any impurity in drug substances and products. 相似文献
3.
Capillary electrophoresis (CE)-mass spectrometry (MS), as an analytical platform, has made significant contributions in advancing metabolomics research, if still limited up to this time. This review, covering reports published between 1998 and 2006, describes how CE-MS has been used thus far in this field, with the majority of the works dealing with targeted metabolite analyses and only a small fraction using it in the comprehensive context. It also discusses how some of the key features of CE-MS were exploited in selected metabolomic applications. 相似文献
4.
Scriba GK 《Journal of chromatography. A》2007,1159(1-2):28-41
Nonaqueous background electrolytes broaden the application of capillary electrophoresis displaying altered separation selectivity and interactions between analytes and buffer additives compared to aqueous background electrolytes. In addition, nonaqueous capillary electrophoresis (NACE) appears to be ideally suited for online coupling with mass spectrometry due to the high volatility and low surface tension of many organic solvents. Despite these advantages and an increasing use of nonaqueous background electrolytes in CE, coupling of NACE to mass spectrometry has not yet been applied very often to date. The present review summarizes the applications of online NACE-MS with regard to the analysis of drugs, stereoisomers, peptides, alkaloids, polymers and others. A brief discussion of solvent effects in NACE and pH of nonaqueous background electrolyte systems is also presented. 相似文献
5.
CE-MS has evolved into a strong alternative to LC-MS. Most of CE-MS applications deal with characterization and identification. However, quantitative aspects have gained importance in, e.g., pharmaceutical and biotechnological applications. Here we summarize and evaluate various methodological aspects in order to achieve sensitive and reproducible results. Similar to LC-MS, aspects of matrix influence on the electrospray process need to be carefully addressed when quantitative results are intended by CE-MS. Due to a more complicated coupling special emphasis needs to be put on the CE-MS interface. Generally linearity over more than three orders of magnitude can be achieved by CE-ESI-MS. Furthermore, a literature survey has been performed in order to give an overview over quantitative measurements performed by CE-MS. The precision can be doubled when changing from a structural related to an isotopically labeled internal standard. Thus a level of precision better than 5% RSD can be achieved. 相似文献
6.
Identification of bioactive peptides in hypoallergenic infant milk formulas by capillary electrophoresis-mass spectrometry 总被引:1,自引:0,他引:1
Català-Clariana S Benavente F Giménez E Barbosa J Sanz-Nebot V 《Analytica chimica acta》2010,683(1):119-125
In this study, we use capillary electrophoresis-mass spectrometry (CE-MS) for the identification of bioactive peptides in hypoallergenic infant milk formulas (IF), which are complex bovine milk protein hydrolysates. A sample clean-up pretreatment with a citrate buffer containing dithiothreitol and urea followed by solid-phase extraction (SPE) with different reversed-phase commercial cartridges was investigated to achieve optimum detection sensitivity in CE-MS. SPE with C18, StrataX and Oasis HLB cartridges allowed detection of the largest number of low molecular mass components, but combination of C18 and StrataX results was enough to achieve an excellent coverage of the studied IF. The monoisotopic molecular mass values of the low molecular mass components obtained by capillary electrophoresis ion-trap mass spectrometry (CE-IT-MS) allowed the tentative identification of nine bioactive sequences. Only the identification of five of them could be confirmed when accurate mass measurements were performed by capillary electrophoresis time-of-flight mass spectrometry (CE-TOF-MS), namely LKP, IPY, ALPM, PGPIHN and VAGTWY, which were reported to present angiotensin-converting enzyme (ACE) inhibitory and antimicrobial activity (only VAGTWY). 相似文献
7.
8.
目前使用的绝大多数药物为手性化合物,它们具有相似的物理和化学性质,但药理活性不同,且常以外消旋混合物的形式存在,因此对手性化合物的分离在生物、环境、食品和医药等领域一直备受关注。与广泛使用的液相色谱-质谱(LC-MS)相比,毛细管电泳-质谱(CE-MS)作为一种新型分离分析技术,具有分离效率高、样品和试剂消耗量低、选择性高和分离模式多样化等诸多优势,已经发展成为手性分析领域中有广阔应用前景的分析方法之一。CE-MS结合了CE的高分离效率和低样品消耗以及MS的高灵敏度和强结构解析能力,在蛋白质组学和代谢组学等领域发挥了重要作用。CE杰出的手性拆分能力与MS优势的结合,亦使CE-MS成为实现手性化合物高效分离分析的完美组合。在过去的十几年里,基于不同CE-MS分离模式的高性能手性分析体系层出不穷,如电动色谱-质谱(EKC-MS)、胶束电动色谱-质谱(MEKC-MS)和毛细管电色谱-质谱(CEC-MS)等,并成功应用于医药、生物、食品和环境科学等领域的手性化合物分析。该文主要综述了2011~2021年,CE-MS在手性化合物分析领域的技术、手性选择剂(如改性环糊精和聚合物表面活性剂等)的使用以及在医药等领域应用方面的研究进展,并讨论了不同手性分析模式的局限性,为未来的CE-MS手性分离分析技术发展及应用提供借鉴。 相似文献
9.
Gómez-Romero M Arráez-Román D Moreno-Torres R García-Salas P Segura-Carretero A Fernández-Gutiérrez A 《Journal of separation science》2007,30(4):595-603
Propolis is a resinous hive product rich in antioxidant compounds. Capillary electrophoresis coupled to mass spectrometric detection can provide selective information about the analytes present in complex extracts of propolis and has turned out to be an attractive alternative to HPLC methods. Therefore, a CE-ESI-MS method has been developed for the analysis of antioxidant compounds obtained from propolis. For this purpose, different electrophoretic parameters such as the nature, pH, and concentration of the separation buffer, as well as electrospray parameters (dry gas temperature and flow, nebulising gas pressure, and make-up flow) have been carefully optimised. Different phenolic compounds (e.g. pinobanksin 3-acetate, naringenin, pinocembrin, chrysin, daidzein, quercetin 3',7-dimethyl ether, apigenin, and kaempferid) could be detected. To confirm the identity of the phenolic compounds in propolis extracts, accurate mass data of the molecular ions were obtained by TOF MS. Limits of detection ranging from 6 mg/100 g of raw propolis for chrysin to 58 mg/ 100 g of raw propolis for luteolin, were obtained. 相似文献
10.
11.
The potential of capillary electrophoresis (CE) for the separation of peptides has been extensively demonstrated in the last decade. Their correct characterization and sequenciation is a difficult task that can be accomplished using CE-mass spectrometry (CE-MS). An important limitation of CE-MS is the buffer choice since it should provide an adequate CE separation without ruining the MS signal. In this work, a new strategy is used to help to solve this limitation based on the combination of two different methodologies. Namely, an ab initio semiempirical model that relates electrophoretic behavior of peptides to their sequence is first used to obtain in a fast and easy way adequate CE buffers compatible with MS analysis. Next, CE-MS is used to separate and characterize peptides via the determination of their relative molecular masses. The usefulness of this procedure is demonstrated analyzing in a single CE-MS run a group of 10 standard peptides of very different nature (i.e., relative molecular masses ranging from 132 to 1037 and isoelectric points ranging from 5.69 to 10.62). It is concluded that the use of this strategy can help to overcome the buffer limitation in CE-MS. 相似文献
12.
Yin-Liang Hsieh Jianyi Cai Yu-Tsyr Li Jack D. Henion Bruce Ganem 《Journal of the American Society for Mass Spectrometry》1995,6(2):85-90
The well known biospecific noncovalent receptor-ligand association complexes between the immunophilin FKBP and the immunosuppressive drugs FK506 and Rapamycin (RM) were investigated by on-line capillary electrophoresis-mass spectrometry (CE-MS) under selected ion monitoring (SIM) conditions and by CE-MS with tandem mass spectrometry (CE-MS/MS) under selected reaction monitoring (SRM) conditions. Solutions of hFKBP (33.3 µM) were dissolved in 50 mM ammonium acetate at pH 7.5. Samples that contained 100 µM of FK506 or RM also were prepared under the same solution conditions. By using these aqueous pH neutral conditions, samples were analyzed by SIM CE-MS and SRM CE-MS and the target complexes were separated by CE with mass spectrometer detection of the individual complexes between FKBP and FK506 [hFKBP + FK506 + 7HJ7+ as well as FKBP and RM [hFKBP + RM + 7HJ7+. In an experiment where a mixture of FK506 and RM was analyzed in the presence of FKBP, a nine-to-one ratio of ion current abundances between the RM and FK506 complexes was observed as reported in the literature from other studies. These results suggest that CE-MS and CE-MS/MS may be yet another analytical method for studying noncovalent interactions of biologically important macromolecules under physiological conditions. 相似文献
13.
Mechref Y 《Electrophoresis》2011,32(24):3467-3481
The high structural variation of glycan derived from glycoconjugates, which substantially increases with the molecular size of a protein, contributes to the complexity of glycosylation patterns commonly associated with glycoconjugates. In the case of glycoproteins, such variation originates from the multiple glycosylation sites of proteins and the number of glycan structures associated with each site (microheterogeneity). The ability to comprehensively characterize highly complex mixture of glycans has been analytically stimulating and challenging. Although the most powerful MS and MS/MS techniques are capable of providing a wealth of structural information, they are still not able to readily identify isomeric glycan structures without high-order MS/MS (MS(n) ). The analysis of isomeric glycan structures has been attained using several separation methods, including high-pH anion-exchange chromatography, hydrophilic interaction chromatography and GC. However, CE and microfluidics CE (MCE) offer high separation efficiency and resolutions, allowing the separation of closely related glycan structures. Therefore, interfacing CE and MCE to MS is a powerful analytical approach, allowing potentially comprehensive and sensitive analysis of complex glycan samples. This review describes and discusses the utility of different CE and MCE approaches in the structural characterization of glycoproteins and the feasibility of interfacing these approaches to MS. 相似文献
14.
This review is focused on the capillary electrophoresis-mass spectrometric (CE-MS) analysis of nucleic acid constituents in the broadest sense, going from nucleotides and adducted nucleotides over nucleoside analogues to oligonucleotides. These nucleic acid constituents play an important role in a variety of biochemical processes. Hence, their isolation, identification, and quantification will undoubtedly help reveal the process of life and disease mechanisms, such as carcinogenesis, and can also be useful for antitumor and antiviral drug research to provide valuable information about mechanism of action, pharmacokinetics, pharmacodynamics, toxicity, therapeutic drug level monitoring, and quality control related to this substance class. Fundamental investigations into their structure, the search for modifications, the occurrence and biochemical impact of structural variation amongst others, are therefore of great value. In view of the related bioanalytical procedures, the coupling of CE to MS has emerged as a powerful tool for the analysis of the complex mixtures of nucleic acid constituents: CE confers rapid analysis and efficient resolution, while MS provides high selectivity and sensitivity with structural characterization of minute amounts of compound. After an introduction about the biochemical and analytical perspectives on the nucleic acid constituents, the different modes of CE used in this field of research as well as the relevant CE-MS interfaces and the difficulties associated with quantitative CE-MS are briefly discussed. A large section is finally devoted to field-oriented applications. 相似文献
15.
Ionization of dichlorophenols for their analysis by capillary electrophoresis-mass spectrometry 总被引:1,自引:0,他引:1
Takeda S Tanaka Y Yamane M Siroma Z Wakida S Otsuka K Terabe S 《Journal of chromatography. A》2001,913(1-2):415-420
The qualitative and quantitative betalain pigment content of two cultivars of prickly pear (Opuntia ficus-indica) fruits grown in southeastern Spain was evaluated. After methanolic extraction of crushed fruits, reversed-phase high-performance liquid chromatography and photodiode array detection were applied simultaneously for the separation, identification and quantification of these pigments. Two main pigments were obtained, which were identified as indicaxanthin (lambda(max) 484 nm) and betanin (lambda(max) 535 nm). Spectrophotometric evaluation of both pigments showed a yield of around 20-30 mg per 100 g of fresh pulp. When the influence of temperature (25 to 90 degrees C) on betacyanin pigment stability was investigated, the results revealed a substantial degree of thermodegradation at temperatures higher than 70 degrees C. 相似文献
16.
The caffeine content of foods and beverages varies considerably, interfering with our ability to obtain valid interpretations in many human studies with regard to the mechanism of action(s) of caffeine and/or its metabolites. The rate of metabolism of caffeine and other xanthine drugs also varies greatly from one individual to another. Therefore, it is extremely important to develop accurate, reliable analytical methods to quantify caffeine and its metabolites in simple and complex matrixes. A simple method is described for the separation and characterization of caffeine and its major metabolites employing capillary electrophoresis (CE) coupled to ultraviolet-absorption and mass spectrometry (MS) detection. After optimization of the electrophoresis separation conditions, a reliable separation of caffeine and 11 of its major metabolites was achieved in 50 mM ammonium carbonate buffer, pH 11.0. The volatile aqueous electrolyte system used with a normal electroosmotic flow polarity also provided an optimal separation condition for the characterization of the analytes by MS. The CE method achieved baseline resolution for all 12 compounds in less than 30 min. The CE-MS method is suitable for use as a routine procedure for the rapid separation and characterization of caffeine and its metabolites. The usefulness of this method was demonstrated by the extraction, separation, and identification of caffeine and its 11 metabolites from normal urine samples. The urine specimens were first acidified to obtain optimum binding efficiency to the sorbents of the off-line, solid-phase extraction procedure employed here, and an acidified eluent solvent was employed for the desorption step to maximize the recovery of the bound analytes. 相似文献
17.
Shamsi SA 《Electrophoresis》2002,23(22-23):4036-4051
A review is presented to highlight several approaches for coupling capillary electrophoresis (CE) and electrospray ionization-mass spectrometry (ESI-MS) for analysis of chiral compounds. A short discussion of commercially available CE-MS instruments and interface design is followed by a detail review on various modes of chiral CE-MS. In general, for each CE-MS mode, the capabilities, applications and limitations for chiral analysis have been pointed out. The first mode, chiral capillary zone electrophoresis-mass spectrometry (CZE-MS) in which neutral derivatized cyclodextrins (CDs) are used is possible using either column coupling with voltage switching or a partial-filling technique (PFT). However, some applications of direct coupling of CZE-MS mode are also reported. The second mode is a chiral electrokinetic chromatography-mass spectrometry (EKC-MS) in which a charged chiral selector such as a sulfated beta-CD or a vancomycin could be conveniently employed. This is because these chiral selectors have a significantly higher countercurrent electrophoretic mobility which prevents the entrance of these selectors into the mass spectrometer. The combination of counter-migration and PFT demonstrates that this synergism could be successfully applied to chiral analysis of a broader range of compounds. It is well-known that the on-line coupling of micellar electrokinetic chromatography to mass spectrometry (MEKC-MS) is problematic because the high surface activity and nonvolatile nature of conventional surfactant molecules lower the electrospray ionization efficiency. However, a recent report demonstrates that this hyphenation is now possible with the use of molecular micelles. Various MEKC-ESI-MS parameters that can be used to optimize both chiral resolution and ESI response are discussed. Finally, two recent examples that demonstrate the feasibility of using either open-tubular or packed chiral CEC with MS are reviewed. This survey will attempt to cover the state-of-the-art on various modes of CE-MS from 1998 up to 2002. 相似文献
18.
N J Reinhoud E Schr?der U R Tjaden W M Niessen M C ten Noever de Brauw J van der Greef 《Journal of chromatography. A》1990,516(1):147-155
An array detection system based on position- and time-resolved ion counting was evaluated for capillary electrophoresis-mass spectrometry using continuous-flow fast atom bombardment and a liquid-junction coupling. Peptides with molecular masses up to 3200 were measured. A 100-1000-fold improvement over conventional detection was demonstrated by applying the array detector in scanning and static modes. Absolute detection limits in the range 1-5 fmol are achievable. 相似文献
19.
Determination of quinolone residues in chicken and fish by capillary electrophoresis-mass spectrometry 总被引:2,自引:0,他引:2
A specific pressure-assisted CE-MS method is described for the analysis of five quinolone residues. MS using a single quadrupole is compared with multiple-stage MS using a quadrupole IT (QIT-MS(n)). The procedure involves a common sample preparation by SPE on disposable cartridges. The most suitable electrolyte is 60 mM (NH(4))(2)CO(3) at pH 9.2. Single quadrupole does not provide enough fragmentation to confirm identities according to the current legislation. However, QIT-MS(n) achieves selective fragmentation. Using this method, danofloxacin, enrofloxacin, flumequine, ofloxacin, and pipemidic acid are analyzed in fortified samples of chicken and fish. Recoveries at levels of 50 ng/g were 62-99%, except for flumequine, which gives recoveries > or =45%. RSDs are from 9 to 16% and the LOD is equal (20 ng/g) for the five analytes. Confirmation of the quinolones' identity is achieved using QIT-MS(3). Forty samples of chicken and fish taken from different local markets are analyzed. Enrofloxacin is also determined in incurred chicken muscle using this method. 相似文献
20.
Hernández-Borges J Borges-Miquel TM Rodríguez-Delgado MA Cifuentes A 《Journal of chromatography. A》2007,1153(1-2):214-226
Sample preparation is a crucial part of chemical analysis and in most cases can become the bottleneck of the whole analytical process. Its adequacy is a key factor in determining the success of the analysis and, therefore, careful selection and optimization of the parameters controlling sample treatment should be carried out. This work revises the different strategies that have been developed for sample preparation prior to capillary electrophoresis-mass spectrometry (CE-MS). Namely the present work presents an exhaustive and critical revision of the different samples treatments used together with on-line CE-MS including works published from January 2000 to July 2006. 相似文献