首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Quantitative detection of metabolites is a highly desirable feature in metabolome analyses. Recently, the successful detection of multiple metabolites using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) in the negative ion mode employing 9-aminoacridine as the organic matrix was reported (Edwards JL, Kennedy RT. Anal. Chem. 2005; 77: 2201-2209). However, there is little information available on quantitative detection of multiple metabolites using MALDI-MS and in particular the influence changes in metabolite levels have on such detections. We investigated this aspect by spiking a synthetic metabolite cocktail (consisting of 39 metabolites including amino acids, organic acids and phospho-metabolites) with five representative metabolites at increasing concentrations, one metabolite at a time, and assessed the signals from replicate determinations. It was possible to detect quantitative changes in the spiked metabolites. Although analyte suppression was observed, it was possible to observe scenarios where the spiked metabolite had little or no influence on the quantitative detection of some metabolites. It appears that the mass spectral response of the metabolite is suppressed only when the spiked chemical species are relatively similar in chemical terms. This suggests that quantitation is possible in scenarios where changes in a specific metabolite or a class of metabolites are monitored following appropriate analyte separation strategies, and that careful interpretations must be made when using the technique for quantitative analysis in unbiased metabolomic approaches.  相似文献   

2.
Visible matrix-assisted laser desorption/ionization (VIS-MALDI) was performed using 2-amino-3-nitrophenol as matrix. The matrix is of near-neutral pH, and has an optical absorption band in the near-UV and visible region. A frequency-doubled Nd:YAG laser operated at 532 nm wavelength was used for matrix excitation and comparisons were made with a frequency-tripled Nd:YAG laser (355 nm). Visible and ultraviolet (UV)-MALDI produce similar mass spectra for peptides, polymers, and small proteins with comparable sensitivities. Due to the smaller optical absorption coefficient of the matrix at 532 nm wavelength, the optical penetration depth is larger, and the sample consumption per laser shot in VIS-MALDI is higher than that of UV-MALDI. Nevertheless, VIS-MALDI using 2-amino-3-nitrophenol as matrix may offer a complementary technique to the conventional UV-MALDI method in applications where deeper laser penetration is required.  相似文献   

3.
We have employed a light-absorbing electrically conductive polymer as a matrix to determine the molecular mass of small organic molecules using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. This method, which is in contrast to the usual MALDI strategy for matrix selection in which a small molecule matrix is used with a high molecular mass analyte, addresses the problem of matrix interference which limits the usefulness of MALDI-TOF for small molecule analysis. Use of negative ion mode offers advantages for this application. Using this approach, we have obtained clean molecular ion mass spectra of small organic molecules in the mass range 100-300 Da.  相似文献   

4.
Porous silicon powder and silica gel particles have been applied as inorganic matrices for the analysis of small molecules in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOFMS). In contrast to conventional MALDI-TOFMS, the signal interference of low-molecular analytes by the matrix has been eliminated. Almost no fragmentations of the analytes were observed. Effects of various factors, such as the particle and pore size, the suspending solution, and sample preparation procedures, on the intensity of mass spectra have been investigated. The pore structure of the inorganic matrix and penetration of the analytes into the pores must be optimized for effective desorption and ionization of the analytes. Matrices (DHB and HCCA) were covalently bound to silica gel for improvement of spectrum intensity. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

5.
We analyzed oligonucleotides by nanoparticle-assisted laser desorption/ionization (nano-PALDI) mass spectrometry (MS). To this end, we prepared several kinds of nanoparticles (Cr-, Fe-, Mn-, Co-based) and optimized the nano-PALDI MS method to analyze the oligonucleotides. Iron oxide nanoparticles with diammonium hydrogen citrate were found to serve as an effective ionization-assisting reagent in MS. The mass spectra showed both [M - H](-) and [M + xMe(2+)- H](-) (Me: transition metal) peaks. The number of metal-adducted ion signals depended on the length of the oligonucleotide. This phenomenon was only observed using bivalent metal core nanoparticles, not with any other valency metal core nanoparticles. Our pilot study demonstrated that iron oxide nanoparticles could easily ionize samples such as chemical drugs and peptides as well as oligonucleotides without the aid of an oligonucleotide-specific chemical matrix (e.g., 3-hydroxypicolinic acid) used in conventional MS methods. These results suggested that iron-based nanoparticles may serve as the assisting material of ionization for genes and other biomolecules.  相似文献   

6.
In order to meet the challenges facing modern chemistry, biology, and medicine, methods are required capable of performing rapid and reliable analysis of both individual compounds and complex mixtures at the molecular level. Matrix-assisted laser de-sorption/ionization mass spectrometry meets these requirements; however, some limitations complicate its application for the analysis of small molecules. Recently, small-molecule analysis has greatly progressed owing to development of surface-assisted laser desorption/ionization mass spectrometry involving approaches which combine the unique properties of nanostructured surface chemistry and morphology. This review examines such approaches and their specific application in small-molecule mass analysis.  相似文献   

7.
Tetrathiofulvalene compounds are important components of charge-transfer complexes, which may be applied in various fields of scientific research and practical applications. Some of these compounds cannot be characterized by mass spectrometry. Here, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry was used for the characterization of tetrathiofulvalenes. The samples could be easily desorbed and ionized to form singly charged ions, and mass spectra with isotopic resolution readily obtained. The mass spectrometric results for 26 compounds have shown that MALDI-TOF is more effective and convenient than other mass spectrometry methods, and resolves the problem of mass spectrometric characterization of tetrathiofulvalene compounds.  相似文献   

8.
Cheng YC  Chen KH  Wang JS  Hsu WL  Chien CC  Chen WY  Tsao CW 《The Analyst》2012,137(3):654-661
This study developed a rapid, sensitive, and matrix-free method for the determination of amphetamine (AMP), methamphetamine (MA), codeine (COD), morphine (MOR), and ketamine (KET) using nanostructured silicon surface assisted laser desorption/ionization mass spectrometry (nSi-MS). The nanostructured silicon (nSi) chip used in this study was created by employing the metal-assisted etching process. Drug standard tests were applied to the nSi chip platform to evaluate the nSi-MS performance, including detection sensitivity, limit of detection, linearity, and repeatability. Real urine samples obtained from drug addict detainees were directly applied to the nSi chip for drug analysis. By observing the nSi-MS spectra, the target drug peaks can be identified; and an antibody pull-down assay was performed to confirm the specificity of the detected targets. nSi-MS drug quantification was assayed, yielding comparable results with those from using the GC-MS approach. The advantages of applying nSi-MS to analyze AMP, MA, COD, MOR, and KET in the urine of addicts are simple, extremely small urine volumes (~10 μL), and a fast analysis procedure (<15 minutes).  相似文献   

9.
Gold nanoparticles (AuNPs) were applied and optimized as matrix for matrix‐assisted laser desorption/ionization mass spectrometry analysis of animal tissues, and enabled histological analysis of animal tissues at molecular level by imaging mass spectrometry (IMS). AuNPs were coated on animal tissue in a solvent‐free manner via argon ion sputtering. Metabolites, including neurotransmitters, fatty acids and nucleobases, were directly detected from mouse brain tissue. Based on region‐specific chemical profiles, fine histological features of mouse brain tissue and heterogeneous regions of tumor tissue were both revealed. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
We describe the application of silver nanoparticles (Ag NPs) as matrices for the determination of three estrogens using surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS). Because Ag NPs have extremely high absorption coefficients (1.2 x 10(8) M(-1) cm(-1)) at 337 nm, they are effective SALDI matrices when using a nitrogen laser. Three tested estrogens-estrone (E1), estradiol (E2), and estriol (E3)-adsorb weakly onto the surfaces of the Ag NPs, through van der Waals forces. After centrifugation, the concentrated analytes adsorbed on the Ag NPs were subjected directly to SALDI-MS analyses, with the limits of detection for E1, E2, and E3 being 2.23, 0.23, and 2.11 muM, respectively. The shot-to-shot and batch-to-batch variations for the three analytes were less than 9% and 13%, respectively. We validated the practicality of this present approach through the quantitation of E2 in human urine. Using this approach, we determined the concentration of E2 in a sample of a pregnant woman's urine to be 0.16 +/- 0.05 muM (n = 10).  相似文献   

11.
Direct matrix-assisted laser desorption/ionization time-of-flight mass spectrometric (MALDI-TOFMS) analysis of solutions of edible fats/oils yielded spectra useful for their rapid differentiation and classification. Results also reflected the individual fatty acid components and their degree of unsaturation. After dissolution in hexane, MALDI-MS analysis revealed spectra showing characteristic triacylglycerols (TAGs), the main fat/oil components, as sodium adduct ions. The Euclidean distances calculated using the mass and intensity values for 20 TAGs were used to evaluate and compare spectra. With cluster analysis, animal fats grouped together differently than vegetable oils and the individual oils grouped together by type. The ion abundances for the individual TAGs and their presumed compositions were used to approximate the overall fatty acid composition of canola, soybean, corn, olive and peanut oil, as well as lard. Using this approach the calculated fatty acid compositions and degree of unsaturation generally fell within about 4% of literature values. When the degree of saturation was compared with values calculated from the package labeling the differences were about 7%.  相似文献   

12.
我们发展了一种利用基质辅助激光解析电离飞行时间质谱技术(MALDI-TOF MS)分析对金属离子具有较高亲和力的寡核苷酸G-四链体的方法.考察了不同基质:3-羟基吡啶甲酸(3-HPA)与柠檬酸氢二铵(DHC)混合基质、3,4-二胺基苯基苯甲酮(DABP)及DABP/DHC混合基质,应用于G-四链体分析的效果.实验结果表...  相似文献   

13.
In this paper, mesoporous tungsten titanate (WTiO) with different nano-pore structures was utilized as matrix for the analysis of short peptides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Effect of characteristic features of mesoporous matrices on laser desorption/ionization process was investigated. Experiments showed that the ordered two-dimensional and three-dimensional mesoporous matrices were superior in performance to the non-ordered WTiO matrix. The dramatic enhancement of signal sensitivity by the ordered mesoporous matrices can be reasonably attributed to the ordered structure, which facilitated the understanding on structure-function relationship in mesoporous cavity for laser desorption process of adsorbed biomolecules. With the ordered mesoporous matrix, the short peptides are successfully detected. The presence of trace alkali metal salt effectively increased the analyte ion yields and the MALDI-TOFMS using the inorganic mesoporous matrices displayed a high salt tolerance. The developed technique also showed a satisfactory performance in peptide-mapping and amino-acid sequencing analysis.  相似文献   

14.
A novel matrix substance, 2-(4-hydroxyphenylazo) benzoic acid, or HABA, has been found to be very advantageous for matrix-assisted ultraviolet laser desorption ionization mass spectrometry. This compound has been successfully used for the desorption of peptides, proteins, and glycoproteins up to approximately 250 kDa. For these materials, the most abundant analyte-related peaks correspond to [M + H]+ ions and multiply protonated molecules. Comparisons with sinapic acid, 2,5-dihydroxybenzoic acid, and α-cyano-4-hydroxycinnamic acid indicate that the new matrix provides comparable sensitivity for peptides and smaller proteins but results in better sensitivity for larger proteins and glycoproteins in protein mixtures. Other matrices discriminate against the higher mass components in these cases. Somewhat reduced mass resolution has been found for smaller proteins, but for larger proteins and glycoproteins the best mass resolution can often be obtained with the new matrix. For other classes of compounds that form ions predominantly via cation attachment, at least as good sensitivity and even better resolution have been obtained. Derivatized glycolipids and synthetic polymers have been studied in detail. For the analysis of many synthetic polymers, the best performance in terms of sensitivity and mass resolution has been observed with HABA matrix. Mass resolution was higher for cation adducts than for the protonated peptide molecules in the same mass range. The new matrix exhibits greatly extended (in time) analyte ion production and reproducibility. Owing to the uniform sample surface with this matrix, barely any spatial variation of the ion signal could be observed. In addition, many hundreds of single-shot mass spectra could be accumulated from the same spot, even for larger proteins.  相似文献   

15.
The recently developed technique of desorption electrospray ionization (DESI) has been applied to the rapid analysis of controlled substances. Experiments have been performed using a commercial ThermoFinnigan LCQ Advantage MAX ion-trap mass spectrometer with limited modifications. Results from the ambient sampling of licit and illicit tablets demonstrate the ability of the DESI technique to detect the main active ingredient(s) or controlled substance(s), even in the presence of other higher-concentration components. Full-scan mass spectrometry data provide preliminary identification by molecular weight determination, while rapid analysis using the tandem mass spectrometry (MS/MS) mode provides fragmentation data which, when compared to the laboratory-generated ESI-MS/MS spectral library, provide structural information and final identification of the active ingredient(s). The consecutive analysis of tablets containing different active components indicates there is no cross-contamination or interference from tablet to tablet, demonstrating the reliability of the DESI technique for rapid sampling (one tablet/min or better). Active ingredients have been detected for tablets in which the active component represents less than 1% of the total tablet weight, demonstrating the sensitivity of the technique. The real-time sampling of cannabis plant material is also presented.  相似文献   

16.
We describe here the use of a hybrid ionization approach, matrix-enhanced surface-assisted laser desorption/ionization mass spectrometry (ME-SALDI-MS) in bioimaging. ME-SALDI combines the strengths of traditional matrix-assisted laser desorption/ionization (MALDI) and SALDI and enables successful MS imaging of low-mass species with improved detection sensitivity. Using 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) as the MS standard, MS performances of MALDI, SALDI, and ME-SALDI are systematically compared. The analyte desorption and ionization mechanism in ME-SALDI is qualitatively speculated based on the observation of significantly reduced matrix background and improved survival yields of molecular ions. Improvements in detection sensitivity of low-mass species using ME-SALDI over MALDI in imaging are demonstrated with mouse heart and brain tissues.  相似文献   

17.
Fine metal or metal oxide powder as an alternative to conventional organic matrices in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) has been utilized successfully for lower molecular mass analytes, poly(ethylene glycol) 200 (PEG 200) and methyl stearate. Eleven kinds of particle, Al, Mn, Mo, Si, Sn, SnO2, TiO2, W, WO3, Zn and ZnO, were evaluated. The analyte was mixed with a metal or metal oxide powder (inorganic matrix) with particle diameter of tens of micrometers and liquid dispersant, followed by application to the sample target. Using a commercial MALDI-TOFMS instrument equipped with an internal 337 nm pulsed nitrogen laser, the analytes, PEG 200 and methyl stearate, were ionized as the alkali metal ion adducted molecules [M+Na]+ or [M+K]+ when the inorganic matrices Mn, Mo, Si, Sn, TiO2, W, WO3, Zn or ZnO were used. In the case of an Al matrix, PEG 200 was ionized as [M+K]+, whereas methyl stearate was ionized as [M+H]+ and [M+Al]+. These particles have potential as the matrix for MALDI. During our examination, however, only SnO2 particles did not ionize either PEG 200 or methyl stearate. Based on our protocol, when TiO2 powder was suspended with liquid paraffin, PEG 200 and methyl stearate gave their MALDI-TOF mass spectra with the lowest background noise and highest intensity. TiO2 powder seemed to be a broad potential matrix for low molecular mass polar or non-polar analytes. The results suggested that bulk particles caused rapid heating/vaporization processes and ionized analyte molecules under irradiation with a pulsed UV laser. The present method can be readily applied to obtain the low background noise MALDI-TOF mass spectra of small-sized compounds.  相似文献   

18.
Various types of ionization of organotellurium compounds in mass-spectrometric study are considered, with diphenyl telluroxide as example. The mass spectra of diphenyl telluroxide are presented. The possibility of applying surface-activated and matrix-assisted laser desorption/ionization mass spectrometry to organotellurium compounds is examined.  相似文献   

19.
The intact noncovalent structure of the homo-oligomeric complexes of streptavidin (52 kDa), alcohol dehydrogenase (150 kDa), and beef liver catalase (240 kDa) have been observed using the matrix 2,6-dihydroxyacetophenone in an organic solvent. Intact streptavidin tetramers could also be observed with ferulic acid and other hydroxyacetophenone derivatives. Intact complexes are observed only for the first shot at a given position, which may be due to physical segregation or precipitation of the noncovalent complexes at the crystal surface. This effect is independent of the macroscopic crystal structure or the type of substrate (hydrophobic versus hydrophilic). Observation of intact complexes is not affected by addition of less than 10 mM salts or buffers, and appears to be independent of the pH stability range of the protein samples investigated.  相似文献   

20.
Matrix-assisted laser desorption ionization is a recently developed new ionization technique which enables macromolecular compounds to be investigated by mass spectrometry. The general features of the technique are described, they have so far mainly been worked out for biopolymers such as proteins. Fast and precise molecular weight determination is possible up to 400,000 Dalton. First examples described in this paper indicate that the technique also holds great promise for the investigation of synthetic polymers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号