首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
A performant reagentless electrochemiluminescent (ECL) detection system for H2O2 is presented, based on an electropolymerized polyluminol film prepared under near-neutral conditions. Such an original polyluminol electrodeposition is reported for the first time and on a screen-printed electrode (SPE) surface. Electropolymerized luminol acts as an active luminophore of the electrochemiluminescent reaction, as the monomer does. Polymerization conditions have been optimized in order to obtain the best ECL responses to H2O2. By performing electrodeposition in a potentiostatic mode, at 425 mV vs. Ag|AgCl, in 0.1 mol L−1 phosphate/0.1 mol L−1 KCl pH 6 and 1 mmol L−1 luminol, with a total charge of 0.5 mC, the linear range for H2O2 detection extends from 7.9 × 10−8 mol L−1 to 1.3 × 10−3 mol L−1. Such performant disposable reagentless easy-to-use miniaturized systems based on SPEs should be applicable to the electrochemiluminescent detection of many oxidase-substrate compounds. Figure An original polyluminol electrodeposition process on a screen-printed electrode surface is reported for the first time. The polymeric structure is demonstrated to behave as an electrochemiluminescent luminophore, allowing disposable reagentless easy-to-use optical sensors for hydrogen peroxide detection to be designed.  相似文献   

2.
A novel fluorescence quenching method for the determination of cationic surfactants (CS), specifically cetyltrimethylammonium bromide (CTAB), dodecyltrimethylammonium bromide (DTAB), and cetylpyridinium chloride (CPC), has been developed using water-soluble luminescent CdTe quantum dots (QDs) modified with thioglycolic acid (TGA). The possible interference from heavy and transition metals (HTM) has been efficiently eliminated through simple sample treatment with mercapto cotton made in-house. Under optimum conditions, the extent of fluorescence quenching of CdTe QDs is linearly proportional to the concentration of CS from 2.0 × 10−7 to 7.0 × 10−6 mol L−1 with a detection limit of 5.0 × 10−8 mol L−1. The relative standard deviation for 1.0 × 10−6 mol L−1 CTAB is 2.5% (n = 6). The proposed method exhibits high sensitivity and selectivity and furthermore avoided the use of toxic organic solvents and tedious solvent extraction procedures. It has been applied to the determination of trace CS in natural river water and commodity samples with satisfactory results. Potential interference from heavy and transition metals is eliminated during photoluminescence detection of CS through simple sample pre-treatment with mercapto cotton  相似文献   

3.
In the presence of carbonate and uranine, the chemiluminescent intensity from the reaction of luminol with hydrogen peroxide was dramatically enhanced in a basic medium. Based on this fact and coupled with the technique of flow-injection analysis, a highly sensitive method was developed for the determination of carbonate with a wide linear range. The method provided the determination of carbonate with a wide linear range of 1.0 × 10−10–5.0 × 10−6 mol L−1 and a low detection limit (S/N = 3) of carbonate of 1.2 × 10−11 mol L−1. The average relative standard deviation for 1.0 × 10−9–9.0 × 10−7 mol L−1 of carbonate was 3.7% (n = 11). Combined with the wet oxidation of potassium persulfate, the method was applied to the simultaneous determination of total inorganic carbon (TIC) and total organic carbon (TOC) in water. The linear ranges for TIC and TOC were 1.2 × 10−6–6.0 × 10−2 mg L−1 and 0.08–30 mg L−1 carbon, respectively. Recoveries of 97.4–106.4% for TIC and 96.0–98.5% for TOC were obtained by adding 5 or 50 mg L−1 of carbon to the water samples. The relative standard deviations (RSDs) were 2.6–4.8% for TIC and 4.6–6.6% for TOC (n = 5). The mechanism of the chemiluminescent reaction was also explored and a reasonable explanation about chemical energy transfer from luminol to uranine was proposed. Figure Chemiluminescence profiles in batch system. 1, Injection of 100 μL of K2CO3 into 1.0 mL luminol-1.0 mL H2O2 solution; 2-3 and 4-5, Injection in sequence of 100 μL of K2CO3 and 100 μL of uranine into 1.0 ml luminol-1.0 mL H2O2 solution; Cluminol = 1.0 × 10−7 mol/L, CH2O2 = 1.0 × 10−5 mol/L, Curanine = 1.0 × 10−5 mol/L, CK2CO3 = 1.0 × 10−7 mol/L except for 4-5 where CK2CO3 = 1.0 × 10−4 mol/L  相似文献   

4.
A novel electrochemical sensor for methyl parathion based on silicate– cetyltrimethylammonium bromide nanocomposite film has been fabricated by electro-assisted deposition onto glassy carbon electrode in one-step via an electrochemical modulation of pH at the electrode/solution interface to promote controlled gelification of tetraethylorthosilicate sol, and was characterized with scanning electron microscopy, X-ray diffraction, and electrochemical impedance spectroscopy. The electrochemical sensing of methyl parathion on the film-modified electrode was investigated applying cyclic voltammetry and square wave voltammetry. Compared to the unmodified electrode, the shapes of the redox peaks were improved and the peak currents significantly increased. Experimental parameters such as deposition time, pH value, and accumulation conditions have been optimized. A linear relationship between the peak current and methyl parathion concentration was obtained in the range from 1.0 × 10−7 to 1.0 × 10−4 mol L−1 with a detection limit of 1.04 × 10 −8 mol L−1 (S/N = 3) after accumulation at 0 V for 120 s. The film electrode shows great promise for determination of methyl parathion in real samples.   相似文献   

5.
Molecular wires containing copper(II) (CuMW), in the form of the coordination polymer (Cu(II)4(bpp)4(maa)8(H2O)2).2H2O (bpp=1,3-bis(4-pyridyl)propane, maa=2-methylacrylic acid), and multiwalled carbon nanotubes (CNT) have been combined to prepare a paste electrode (CuMW/CNT/PE). The voltammetric response of the CuMW/CNT/PE to metformin (MET) was significantly greater than that of electrodes prepared from other materials, because of both the surface effect of CuMW and CNT and coordination of MET with the Cu(II) ion in the CuMW. A novel voltammetric method for determination of MET is proposed. In pH 7.2 Britton–Robinson buffer, using single sweep voltammetry, the second-order derivative peak current for oxidation of MET at 0.97 V (relative to SCE) increased linearly with MET concentration in the range 9.0 × 10−7–5.0 × 10−5 mol L−1 and the detection limit was 6.5 × 10−7 mol L−1. Figure When a combination of molecular wires containing copper(II) (CuMW) and multiwalled carbon nanotubes (CNT) was used to prepare a paste electrode (CuMW/CNT/PE) the voltammetric response to metformin (curve c) was significantly higher than that at a carbon/PE (curve a) or a CNT/PE (curve b), because of the amplification effect of CNT and CuMW. A novel voltammetric method is proposed for determination of MET  相似文献   

6.
The redox characteristics of the drug domperidone at a glassy-carbon electrode (GCE) in aqueous media were critically investigated by differential-pulse voltammetry (DPV) and cyclic voltammetry (CV). In Britton–Robinson (BR) buffer of pH 2.6–10.3, an irreversible and diffusion-controlled oxidation wave was developed. The dependence of the CV response of the developed anodic peak on the sweep rate (ν) and on depolizer concentration was typical of an electrode-coupled chemical reaction mechanism (EC) in which an irreversible first-order reaction is interposed between the charges. The values of the electron-transfer coefficient (α) involved in the rate-determining step calculated from the linear plots of E p,a against ln (ν) in the pH range investigated were in the range 0.64 ± 0.05 confirming the irreversible nature of the oxidation peak. In BR buffer of pH 7.6–8.4, a well defined oxidation wave was developed and the plot of peak current height of the DPV against domperidone concentration at this peak potential was linear in the range 5.20 × 10−6 to 2.40 × 10−5 mol L−1 with lower limits of detection (LOD) and quantitation (LOQ) of 6.1 × 10−7 and 9.1 × 10−7 mol L−1, respectively. A relative standard deviation of 2.39% (n = 5) was obtained for 8.5 × 10−6 mol L−1 of the drug. These DPV procedures were successfully used for analysis of domperidone in the pure form (98.2 ± 3.1%), dosage form (98.35 ± 2.9%), and in tap (97.0 ± 3.6%) and wastewater (95.0 ± 2.9%) samples. The method was validated by comparison with standard titrimetric and HPLC methods. Acceptable error of less than 3.3 % was also achieved. Figure In aqueous media at pH 7.6- 8.4, the DPV and cyclic voltammetry of the drug domperidone (I) at GCE showed an irreversible and diffusion controlled oxidation wave. The values of the electron transfer coefficient (α) involved in the rate determining step were found in the range 0.64± 0.05 confirming the irreversible nature of the peak. The analysis of the drug in pure form and in wastewater samples was successfully achieved  相似文献   

7.
A highly selective and sensitive chemiluminescence method for the determination of triclosan is proposed. The method is based on the phototransformation of triclosan to a light-emitting precursor in the presence of fluorescein in alkaline medium and the chemiluminescence reaction is then triggered by strong base or oxidants such as N-bromosuccinimide. Based on this reaction an online phototransformation–flow injection manifold was developed, in which the photoreactor comprises a 150-cm-long × 0.8-mm-i.d. piece of PTFE tubing coiled around a 25-W fluorescent lamp, and the phototransformed products were then injected into a carrier stream of borate buffer. After mixing with the oxidant stream the produced light was detected by a photomultiplier. A wide calibration range from 8.0 × 10−8 to 1.0 × 10−4 mol L−1 was obtained under the optimized conditions, and the detection limit was as low as 5.0 × 10−8 mol L−1. The whole process of analysis, including the online phototransformation and subsequent chemiluminescence detection, could be completed in 6 min. Most of the foreign substances tested showed high tolerance levels, and the proposed method was directly applied to the determination of triclosan in toothpaste samples without any pre-separation procedure. Figure Schematic representation of the phototransformation of triclosan and subsequent chemiluminescence reaction  相似文献   

8.
We have developed a circular-dichroism thermal lens microscope for UV wavelengths (UV-CD-TLM), for the first time, to realize sensitive chiral analysis on a microchip. Quasi-continuous-wave phase modulation of a pulsed UV laser was used to generate left-circularly polarized light and right-circularly polarized light and to detect the generated TL signal amplitude and phase with a lock-in amplifier. The amplitude and phase were used to determine the concentration and chirality, respectively, of a sample. The basic principle of UV-CD-TLM for chiral analysis on a microchip was verified by measuring aqueous solutions of optically active camphorsulfonic acids (CSA). Lower limits of detection (LOD) were calculated at S/= 2 and were 8.7 × 10−4 mol L−1A = 5.2 × 10−6 Abs.) for (+)-CSA and 8.4 × 10−4 mol L−1A = 5.0 × 10−6 Abs.) for (−)-CSA. In terms of number of molecules, LODs for UV-CD-TLM were calculated to be 8.7 fmol and 8.4 fmol, respectively. This is at least three orders of magnitude lower than previously obtained. The applicability of UV-CD-TLM for chiral analysis on a microchip was verified. Figure Sensitive chiral analysis by thermal lens microscope (TLM)  相似文献   

9.
The simultaneous determination of three isomers of phenylenediamines (o, m, and p-phenylenediamine) and two isomers of dihydroxybenzenes (catechol and resorcinol) in hair dyes was performed by capillary zone electrophoresis coupled with amperometric detection (CZE–AD). The effects of working electrode potential, pH and concentration of running buffer, separation voltage, and injection time on CZE–AD were investigated. Under the optimum conditions the five analytes could be perfectly separated in 0.30 mol L−1 borate–0.40 mol L−1 phosphate buffer (pH 5.8) within 15 min. A 300 μm diameter platinum electrode had good responses at +0.85 V (versus SCE) for the five analytes. Their linear ranges were from 1.0 × 10−6 to 1.0 × 10−4 mol L−1 and the detection limits were as low as 10−7 mol L−1 (S/N = 3). This working electrode was successfully used to analyze eight kinds of hair dye sample with recoveries in the range 91.0–108.0% and RSDs less than 5.0%. These results demonstrated that capillary zone electrophoresis coupled with electrochemical detection using a platinum working electrode as detector was convenient, highly sensitive, highly repeatable and could be used in the rapid determination of practical samples. Figure Electropherograms obtained from 10 mg mL−1 hair dye sample solutions at a platinum working electrode under optimum CZE–AD conditions: (a) natural black (I), (b) golden: (1) p-phenylenediamine, (2) m-phenylenediamine, (3) o-phenylenediamine, (4) resorcinol, and (5) catechol  相似文献   

10.
A comparison of a differential pulse polarographic with a phase sensitive alternating current polarographic study of the Cd-Cys-Gly and Cd-PC2 systems [PC2 being a phytochelatin of general structure (γ-Glu-Cys) n -Gly, with n = 2] has been performed. The chemometric multivariate curve resolution method with alternating least squares was applied in the experimental data analysis. The results obtained by both polarographic techniques have made it possible to find out the formation sequences of the complexes and their final stoichiometries. The alternating current polarograms compared with the differential pulse ones show some differences (a new signal and an important shift of peak potentials), which anyway are consistent with some of the conclusions obtained by differential pulse polarography. This fact implies that although the alternating current polarography results need some corrections before data treatment, they provide extra information that complements the conclusions achieved by differential pulse polarography. Figure Voltammograms at ACP(−10°), ACP(−65°) and corrected ACP during the titration of a 10−5 mol L−1 Cd(II) solution with PC2 at pH 8.5 in 0.05 L−1 Tris.  相似文献   

11.
This paper described the determination of p-nitroaniline in a double organic substrate oscillating system of tartrate-acetone-Mn2+-KBrO3-H2SO4. Under the optimum conditions, temperature was chosen as a control parameter to design the bifurcation point and proposed a convenient method for determination of p-nitroaniline. Results showed that the system consisting of 3.5 mL 0.06 mol L−1 tartrate, 4.0 mL 0.7 mol L−1 H2SO4, 1.5 mL 1.5×10−4 mol L−1 MnSO4, 4.0 mL 0.4 mol L−1 acetone and 7.0 mL 0.05 mol L−1 KBrO3 was very sensitive to the surrounding at 33.5°C. A good linear relationship between the potential difference and the negative logarithm concentration of p-nitroaniline was obtained to be in the range of 2.50×10−7∼3.75×10−5 mol L−1 with a lower detection limit of 2.50×10−8 mol L−1.   相似文献   

12.
Biogas is produced by biological processes under anaerobic conditions and may contain up to 20,000 ppmv hydrogen sulfide (H2S), a corrosive substance that attacks power engines and can affect the health of the industrial staff. H2S must be removed from the biogas, especially in co-generation facilities where the biogas is burnt for energy production. Nowadays, biofiltration is being studied and considered as an interesting alternative for removing H2S from the biogas besides classical chemical processes. The novelty of this work is the design and construction of an automated H2S on-line analyser to assess the composition of the liquid and gas phases of gas-phase bioreactors. The analyser is made of two parallel flow configurations which share the same detection device. The first configuration is a single-channel flow injection analyser (FIA) to detect S2− in the liquid phase. The second configuration is a continuous flow analyser (CFA) with a gaseous diffusion step (GD–CFA) for detecting H2S in the gas phase. The diffusion step enables separation of the H2S(g) from the sample and its conversion into a detectable chemical species (S2−). S2− detection was performed with an Ag2S ion-selective electrode (ISE) selective to . The main response parameters of the FIA system are a linear range between 3 × 10−5 and 1 × 10−1 mol L−1 S2− (0.61–3,200 mg L−1), with a sensitivity of 27.9 mV decade−1 and a detection limit of 1.93 × 10−5 mol L−1 S2−. The GD–CFA configuration presents a linear range between 400 and 10,000 ppmv H2S(g) with a sensitivity of 26.1 mV decade−1 and a detection limit of 245 ppmv H2S. The proposed analyser was used by analysing real gas and liquid samples with optimal results at a full-scale biotrickling filter for biogas treatment at a municipal wastewater treatment plant. Figure The novelty of this work is the design and construction of an automated H2S on-line analyzer to assess the composition of the liquid and gas phases of gas-phase bioreactors. The analyser is made of two parallel flow configurations which share the same detection device. The first configuration is a single-channel flow injection analyser (FIA) to detect S2- in the liquid phase. The second configuration is a continuous flow analyser (CFA) with a gaseous diffusion step (GD-CFA) for detecting H2S in the gas phase.  相似文献   

13.
A sensitive and convenient method for the determination of trace europium ions using an oscillating chemical reaction involving Ce(IV) - KBrO3 - acetone - oxalic acid - H2SO4 was proposed. The results indicated that the changes in oscillating period (T) was linearly proportional to the negative logarithmic concentration of Eu3+ (-log C) in the range of 1.41 × 10−8 ˜ 1.41 × 10−4 mol L−1 (r = 0.9982) with a detection limit of 1.04 × 10−9 mol L−1. The recoveries were limited to the range of 99.5% to 100.8%. Under the same conditions, other rare earth ions did not interfere with the determination of Eu3+. In addition, a perturbation mechanism was also discussed briefly.   相似文献   

14.
A capacitive biosensor for the detection of bacterial endotoxin has been developed. Endotoxin-neutralizing protein derived from American horseshoe crab was immobilized to a self-assembled thiol layer on a biosensor transducer (Au). Upon injection of a sample containing endotoxin, a decrease in the observed capacitive signal was registered. Endotoxin could be determined under optimum conditions with a detection limit of 1.0 × 10−13 M and linearity ranging from 1.0 × 10−13 to 1.0 × 10−10 M. Good agreement was achieved when applying endotoxin preparations purified from an Escherichia coli cultivation to the capacitive biosensor system, utilizing the conventional method for quantitative endotoxin determination, the Limulus amebocyte lysate test as a reference. The capacitive biosensor method was statistically tested with the Wilcoxon signed rank test, which proved the system is acceptable for the quantitative analysis of bacterial endotoxin (P < 0.05). Figure The flow-injection capacitive biosensor system and the capacitive properties of the transducer surface, where CSAM is the capacitance change of the self-assembled thiol monolayer, CP is the capacitance change of the protein layer, Ca is the capacitance change of the analyte layer and CTotal is the total capacitance change measured at the working electrode/solution interface (modified from Limbut et al., 2006. Biosens Bioelectron 22: 233-240)  相似文献   

15.
Liquid polymer membrane electrodes based on nickel and manganese phthalocyanines were examined for use as anion-selective electrodes. The electrodes were prepared by incorporating the ionophores into plasticized poly(vinyl chloride) membranes, which were directly coated onto the surfaces of graphite electrodes. The resulting electrodes demonstrate near-Nernstian responses over a wide linear range of perchlorate anion (5 × 10−7 to 1 × 10−1 M). The electrodes have a fast response time, submicromolar detection limits (5 × 10−7 M perchlorate), and could be used over a wide pH range of 3.5–10. The influences of lipophilic cationic and anionic additives on the response properties of the electrodes were investigated. The proposed sensors revealed high selectivity for perchlorate over a number of common inorganic and organic anions. The highest selectivity was observed for the electrode based on manganese phthalocyanine in the presence of the lipophilic anionic additive sodium tetrakis[3,5-bis(trifluoromethyl)phenyl]borate. Application of the electrodes to determine perchlorate in tap water and human urine is also reported.   相似文献   

16.
The possibilities of anodic stripping voltammetry (ASV) using an alternating current (AC) scan in the stripping step have been checked through the study of the complexation of cadmium by Suwannee river fulvic acid (SRFA), a reference fulvic acid from the International Humic Substances Society. Because of the strong electrode adsorption of SRFA, AC mode appears to be a good approach to the study when proper selection of the phase angle is made. The goodness of AC mode in ASV has been demonstrated, and the complexation constant of 3.71 ± 0.04 determined is in good agreement with the value of the constant obtained by the reference technique of reverse pulse polarography. Some particularities of SRFA have been observed, among them its homofunctional and strongly heterogeneous behaviour in cadmium complexation and the impossibility of avoiding electrode adsorption problems in ASV measurements at very low metal concentrations. Figure DP anodic stripping and AC anodic stripping voltammograms at −12° and −65° during the titration of a 10−7 mol L−1 Cd(II) solution with SRFA at pH 7.5 in 0.05 L−1 Tris Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

17.
A microfluidic system incorporating chemiluminescence detection is reported as a new tool for measuring antioxidant capacity. The detection is based on a peroxyoxalate chemiluminescence (PO-CL) assay with 9,10-bis-(phenylethynyl)anthracene (BPEA) as the fluorescent probe and hydrogen peroxide as the oxidant. Antioxidant plugs injected into the hydrogen peroxide stream result in inhibition of the CL emission which can be quantified and correlated with antioxidant capacity. The PO-CL assay is performed in 800-μm-wide and 800-μm-deep microchannels on a poly(dimethylsiloxane) (PDMS) microchip. Controlled injection of the antioxidant plugs is performed through an injection valve. Of the plant-food based antioxidants tested, β-carotene was found to be the most efficient hydrogen peroxide scavenger (SA HP of 3.27 × 10−3 μmol−1 L), followed by α-tocopherol (SA HP of 2.36 × 10−3 μmol−1 L) and quercetin (SA HP of 0.31 × 10−3 μmol−1 L). Although the method is inherently simple and rapid, excellent analytical performance is afforded in terms of sensitivity, dynamic range, and precision, with RSD values typically below 1.5%. We expect our microfluidic devices to be used for in-the-field antioxidant capacity screening of plant-sourced food and pharmaceutical supplements. Figure Assembled PDMS microchip sandwiched between two glass plates with the top plate containing capillary reservoirs  相似文献   

18.
Self-assembled monolayers (SAMS) of chemisorbed thioglycollate on a gold electrode surface have been used as a base interface for the electrostatic adsorption of ferrocenium ion. Electrochemical impedance spectra (EIS) and cyclic voltammetry (CV) were used to evaluate the electrochemical properties of the supramolecular film. The bare gold electrode failed to distinguish the oxidation peaks of ascorbic acid (AA) and uric acid (UA) in phosphate buffer solution (PBS, pH 7.0), while the ferricinium–thioglycollate modified electrode could separate them efficiently. In differiential pulse voltammetric measurements, the prepared gold electrode could separate AA and UA signals, allowing the simultaneous determination of AA and UA. Under optimal conditions and within the linear range of 1.0 × 10−6 to 5.0 × 10−4 M, the detection limits of AA and UA achieved were 2.0 × 10−7 and 1.0 × 10−7 M, respectively. The applicability of the prepared electrode was demonstrated by measuring AA and UA in human urine without any pretreatment. Figure Fabrication process for the modified electrode  相似文献   

19.
The damped glycolytic oscillation phenomenon occurring in starved cells of the yeast Saccharomyces cerevisiae (NBRC 0565) was characterization for application to a toxicity bioassay. S. cerevisiae was grown under semi-anaerobic conditions. The transient oscillations were observed photometrically as the time course of the fluorescent intensity of reduced pyridine nucleotide resulting from instantaneous addition of glucose to a cell suspension. In this study, simple and reproducible conditions inducing damped oscillations were obtained by modifying a literature method. For estimation of the wave shapes of the damped oscillations we used six indexes. To investigate the total reproducibility as the averaged relative standard deviation (RSDav) for the six indexes obtained from the wave shapes, the damped oscillations were induced under the optimum conditions and the RSDav values were calculated as 14% in a buffer cell suspension (n = 62) and 22% in a water cell suspension (n = 78). Finally, the effects of glucose concentration on the six indexes were examined, and all the indexes changed when the glucose concentration was changed. Excellent correlations were obtained between the index of oscillation-state time and the concentration of glucose in a buffer cell suspension (r = 0.9985, 0.5–250 mmol L−1, 10 points) and in a water cell suspension (r = 0.9989, 2.5 μmol L−1–250 mmol L−1, 12 points), respectively. Figure Characterization of damped glycolytic oscillation, (a) typical shape, and (b) its estimation Electronic supplementary material The online version of this article (doi:)contains supplementary material, which is available to authorized users.  相似文献   

20.
A new electrochemical biosensor for determination of hydrogen peroxide (H2O2) has been developed by immobilizing horseradish peroxidase (HRP) on silver colloids (nanosilver) and use of a DNA-functionalized interface. In the presence of the DNA and the nanosilver the immobilized HRP gives a pair of well-defined redox peaks with an electron-transfer rate constant of 3.27 ± 0.91 s−1 in pH 7.0 PBS. The presence of DNA also provides a biocompatible microenvironment for enzyme molecules, greatly amplifies the amount of HRP molecules immobilized on the electrode surface, and improves the sensitivity of the biosensor. Under optimum conditions the biosensor has electrocatalytic activity in the reduction of hydrogen peroxide with linear dependence on H2O2 concentration in the range 1.5 × 10−6 to 2.0 × 10−3 mol L−1; the detection limit is 5.0 × 10−7 mol L−1 at a signal-to-noise ratio of 3. The value of HRP in the composite membrane was found to be 1.62 mmol L−1. These results suggest that the properties of the complex film, with its bioelectrochemical catalytic activity, could make it useful for development of bioelectronic devices and for investigation of protein electrochemistry at functional interfaces.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号