首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An analytical method of CE-MS and CE with an online preconcentration technique induced by a dynamic pH junction, addition of organic solvent and large volume injection was developed for sensitive determination of peptides in biological samples. Leucine enkephalin, methionine enkephalin, dynorphin A, β-endorphin and angiotensin II were used as model peptides. The optimal online preconcentration conditions were obtained at a sample matrix consisting of 100?mM borate buffer (pH 10.0) with 50% v/v acetonitrile and a BGE containing 1?M formic acid at pH 2.0, along with a 25-cm injection length. Under the optimized conditions, a 4.0×10(3)-1.1×10(4)-fold increase in peak intensity was achieved without degrading the peak shape. This online preconcentration method was applied to analyze the intracellular angiotensin II within the peptides extracted from HL1 cells and approximately increase of 1×10(4)-fold sensitivity was achieved compared to normal condition. Thus, the developed method could be applied to the analysis of various peptides for peptidomics study in biological samples.  相似文献   

2.
Arnett SD  Lunte CE 《Electrophoresis》2003,24(11):1745-1752
Capillary electrophoresis has been widely used for the analysis of physiological samples such as plasma and microdialysate. However, sample destacking can occur during the analysis of these high-ionic strength samples, resulting in poor separation efficiency and reduced sensitivity. A technique termed pH-mediated stacking of anions (base stacking) has previously been developed to analyze microdialysate samples and achieve on-line preconcentration of analytes by following sample injection with an injection of sodium hydroxide. In this work, the mechanism of base stacking was investigated. Peak efficiency was shown to be a function of background electrolyte and sample ionic strength. Analytes representing several classes of compounds with a wide range of mobilities were used to study the effects of multiple parameters on sample stacking. The length of hydroxide injection required for stacking was shown to be dependent on analyte mobility and the type of amine background electrolyte used. Combinations of electrokinetic and hydrodynamic injections of sample and hydroxide were examined and it was concluded that although stacking could be achieved with several injection modes, electrokinetic injection of both sample and hydroxide was most effective for sample stacking. The mechanism of pH-mediated stacking for each of these modes is presented.  相似文献   

3.
An online dynamic pH junction preconcentration method was developed for quantification of 5‐aminolevulinic acid (ALA) by CE with the separation time less than 6 min. The optimal dynamic pH junction of ALA was carried out between pH 9.3 borate buffer (BGE, 40 mM) and pH 2.5 phosphate buffer (sample matrix, 40 mM) when 4.1 cm of sample plug was hydrodynamically injected into an uncoated fused‐silica capillary (48.5 cm in length, id of 50 μm). If a 24 kV separation voltage was applied, the calibration curve of ALA peak area (200 nm) showed good linearity (R2 = 0.9991) ranging from 0.01 to 6.5 mg/mL. The reproducibility of this system was excellent with RSDs (n = 10) of 2.5% for peak area response and 0.6% for migration time at ALA concentration of 0.5 mg/mL. The LOD was evaluated as 1.0 μg/mL (S/N > 3). Compared to conventional CE procedure, the sensitivity was successfully improved over 50‐fold. The analytical results of pharmaceutical formulations show a good agreement with those by HPLC (r = 0.94).  相似文献   

4.
A new approach has been developed for the direct determination of reduced (glutathione [GSH]) and oxidized (glutathione disulfide [GSSG]) GSH in whole blood by means of capillary electrophoresis. Its features include GSH-stabilizing sample preparation, the use of an internal standard, and pH-mediated stacking. Blood stabilized with acid citrate and K3EDTA was treated with acetonitrile with N-ethylmaleimide, and then the analytes were extracted with diethyl ether. The total analysis time was 8 min using a 50-µm (i.d.) by 32.5-cm (eff. length) silica capillary. The background electrolyte was 0.075-M citrate Na pH 5.8 with 200-µM cetyltrimethylammonium bromide and 5-µM sodium dodecyl sulfate, and the separation voltage was −14 kV. The quantification limit (S/N = 15) of the method was 1.5 µM for GSSG. The accuracy levels of GSH and GSSG analysis were 104% and 103%, respectively, and between-run precision levels were 2.6% and 3.2%, respectively. Analysis of blood samples from healthy volunteers (N = 24) showed that the levels of GSH and GSSG and the GSH/GSSG ratio in the whole blood were 1.05 ± 0.14 mM, 3.9 ± 1.25 µM, and 256 ± 94, respectively. Thus, the presented approach can be used in clinical and laboratory practice.  相似文献   

5.
Capillary electrophoretic separation of samples of physiological origin typically have both poor resolution and efficiency due to destacking. We have previously reported a stacking method for concentration of catecholamines in artificial dialysate, or Ringer's solution. However, pH-mediated sample stacking of other cations has not been investigated. In this report, pH-mediated stacking has been extended to eletripan, dofetilide, doxazosin, sildenafil, UK-103,320, UK-202,581, and CP-122,288. These compounds were chosen without prior structural screening except that they were cationic at the pH of our background electrolyte (BGE). Capillary electrophoretic behavior of samples in BGE is compared with those of samples in Ringer's solution with and without pH-mediated acid stacking. Results indicate that the peak heights and efficiencies for acid-stacked samples are increased compared to the unstacked samples in Ringer's solution or BGE. For example, the peak efficiencies for 5 s injections of eletriptan in BGE and Ringer's solution are 138,000 and 72,000 plates, respectively. In contrast, a 10 s injection of eletriptan followed by acid injection for 16 s produces a peak with 246,000 plates. Evaluation of the stacking effect was performed by comparison of the peak height at similar peak efficiencies for samples in Ringer's solution with and without stacking. Using this method, pH-mediated acid stacking provides a 10- to 27-fold sensitivity enhancement for the seven cations.  相似文献   

6.
An on-line preconcentration capillary electrophoresis (CE) technique, which combines a large volume sample stacking with a dynamic pH junction technique, is introduced in this paper. This dynamic pH junction with co-electroosmotic migration is formed between sodium borate pH 9.5 and sodium phosphate pH 2.5 with 150 mM sodium dodecylsulfate (SDS). A full capillary based injection allows determination of weak acidic compounds at ppb concentration levels (achieved LOD for benzoic acid was 11 nmol L(-1)). The proposed preconcentration method was compared with ITP/ITP (LOD 120 nmol L(-1)), ITP/CZE (LOD 740 nmol L(-1)) and a simple CZE method (LOD 23,330 nmol L(-1)). The analytical potential of this method was assessed with juice test samples.  相似文献   

7.
When using capillary electrophoresis (CE) for the analysis of biological samples, it is often necessary to employ techniques to overcome peak-broadening that results from having a high-conductivity sample matrix. To improve the concentration detection limits and separation efficiency of cationic pharmaceuticals in CE, pH-mediated acid stacking was performed to electrofocus the sample, improving separation sensitivity for the analyzed cations by 60-fold. However, this method introduces a large titrated acid plug into the capillary. To overcome the limitations this low-conductivity plug poses to stacking, the plug was removed prior to the separation step by applying reverse pressure to force it out of the anode of the capillary. Employing this technique allows for roughly twice the volume of sample to be injected. A maximum sample injection time of 240 s was attainable with baseline peak resolution compared to a maximum sample injection time of 120 s without reverse pressure, leading to a twofold decrease in the limits of detection of the analytes used. Separation efficiency overall is also improved when utilizing the reverse pressure step. For example, a 60 s sample injection time results in 94,000 theoretical plates as compared to 60,500 theoretical plates without reverse pressure. This reverse-pressure method was used for detection and quantitation of several cationic pharmaceuticals that were prepared in Ringer's solution to simulate microdialysis sampling conditions.  相似文献   

8.
Shim SH  Riaz A  Choi K  Chung DS 《Electrophoresis》2003,24(10):1603-1611
A dual stacking mechanism based on transient isotachophoresis (TITP) and induced pH junction focusing is demonstrated as a means to increase the concentration sensitivity in capillary electrophoresis of highly saline samples. When stacking was carried out with an unbuffered saline sample of fluorescein between two zones of low mobility background electrolyte at high pH under an electric field of reverse polarity, two transient peaks at both boundaries of the sample zone were observed. One peak at the rear boundary could be inferred as a transient isotachophoretic stacked zone. Through computer simulations of an unbuffered sample with a high concentration of sodium chloride, we showed that the fast moving zones of sodium and chloride ions induced pH changes at both boundaries to satisfy the electroneutrality condition and that the peak at the front boundary was due to the induced pH junction. To verify the pH changes, an indicator, thymol blue, was added to an NaCl solution and the color changes under an electric field were observed. The proposed mechanism was supported by observing the dual stacking procedure for an unbuffered sample of 4-nitrophenol and measuring additional sensitivity enhancements by dual stacking for ten weakly acidic compounds. For the ten analytes including nucleoside phosphates, every dual stacking of an unbuffered sample exhibited an additional enhancement up to 86% larger than that of usual transient isotachophoresis of the corresponding buffered sample without loss of separation efficiency and reproducibility. Therefore, it would be useful to skip over buffering in sample preparation for TITP, contrary to the general recommendation.  相似文献   

9.
A range of compounds were evaluated as probes for the indirect detection of inorganic ions using CE and light-emitting diodes (LEDs) as the light source. Emphasis was placed on examining probes likely to absorb strongly in the UV-Vis region near 350-430 nm as compounds, which absorb at longer wavelengths tend to be bulkier and adsorb onto the capillary wall. These probes should act as a replacement for the very effective but carcinogenic probe chromate. Two probes were identified and evaluated: p-nitrophenol and 4-hydroxy-3,5-dinitrobenzoic acid. The former showed the most potential with low-mobility anions, while the later had a moderate electrophoretic mobility and was more suitable for a wider mobility range of analytes. However, neither could match the efficiencies and LOD of chromate for the separation of the fast inorganic ions such as chloride, nitrate and sulphate. Nevertheless, application of the 4-hydroxy-3,5-dinitrobenzoic acid system to the determination of oxalate in Bayer liquors showed excellent sensitivity and selectivity.  相似文献   

10.
Twenty-eight novel salts with tetramethyl-, tetraethyl-, and tetrabutylammonium and 1-butyl-3-methylimidazolium cations paired with 3,5-dinitro-1,2,4-triazolate, 4-nitro-1,2,3-triazolate, 2,4-dinitroimidazolate, 4,5-dinitroimidazolate, 4,5-dicyanoimidazolate, 4-nitroimidazolate, and tetrazolate anions have been prepared and characterized by using differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and single-crystal X-ray crystallography. The effects of cation and anion type and structure on the physicochemical properties of the resulting salts, including several ionic liquids, have been examined and discussed. Ionic liquids (defined as having m.p.<100 degrees C) were obtained with all combinations of the 1-butyl-3-methylimidazolium cation ([C(4)mim](+)) and the heterocyclic azolate anions studied, and with several combinations of tetraethyl or tetrabutylammonium cations and the azolate anions. The [C(4)mim](+) azolates were liquid at room temperature exhibiting large liquid ranges and forming glasses on cooling with glass-transition temperatures in the range of -53 to -82 degrees C (except for the 3,5-dinitro-1,2,4-triazolate salt with m.p. 33 degrees C). Six crystal structures of the corresponding tetraalkylammonium salts were determined and the effects of changes to the cations and anions on the packing of the structure have been investigated.  相似文献   

11.
Sample stacking is a general term for methods in CE which are used for on-line concentration of diluted analytes. During the stacking process, analytes present at low concentrations in a long injected sample zone are concentrated into a short zone (stack). The stacked analytes are then separated and individual zones are detected. Thus stacking provides better separation efficiency and detection sensitivity. Many papers have been published on stacking till now, various procedures have been described, and, many names have been proposed for stacking procedures utilizing the same principles. This contribution brings an easy and unified view on stacking, describes the basic principles utilized, makes a list of recognized operational principles and brings an overview of principal current procedures. Further, it surveys selected recent practical applications ordered according to their operational principles and includes the terms, nicknames, and acronyms used for these actual stacking procedures. This contribution may help both newcomers and experts in the field of CE to orient themselves in the already quite complex topic of sample stacking.  相似文献   

12.
Summary Velocity-difference induced focusing (V-DIF) of analytes by a dynamic pH junction represents a simple yet effective on-line preconcentration method to improve concentration sensitivity in capillary electrophoresis (CE). Differences in buffer type, pH and conductivity between sample and background electrolyte (BGE) segments of the capillary are properties used to optimize purine focusing within a multi-section electrolyte system. This method permits the injection of large volumes of sample (up to 450 nL or about 18% of capillary length), resulting in over a 50-fold improvement in sensitivity with baseline resolution. The limit of detection (S/N=3) for xanthine is determined to less than 4.0×10−8 M under optimum conditions when using UV detection. Analysis of micromolar amounts of xanthine in pooled urine is also demonstrated without sample pretreatment. A dual mechanism involving dynamic pH and isotachophoretic modes is proposed to enhance analyte focusing performance when employing buffer pH junctions based on different types of electrolyte co-ions.  相似文献   

13.
Various analytical techniques have been developed over the years to analyse a large diversity of biomolecules with a constant push towards ultra-sensitive detection. CE is at the forefront of the most powerful analytical tools available to date when considering its superior efficiency and resolution; however, the technique suffers from poor sensitivity as a result of the short path length at the detection site and small injection volumes (typically <1% capillary length). One of the approaches to abate the inherent problem is to employ clever chemistry using sample focusing techniques whereby a large sample plug can be injected, preconcentrated and separated, producing excellent sensitivity and efficiency at the detector. This particular review will focus on the use of dynamic pH junction as a means of improving sensitivity in CE and focuses on the use of a change in analyte ionisation due to different pHs between the sample and electrolyte. The review provides a fundamental discussion of the mechanisms, buffer and sample conditions required to concentrate various analytes and a comprehensive list of published works in tabular format for easy identification of suitable conditions for new applications. The review further encompasses the use of dynamic pH junction in CE and its involvement in combination with other preconcentrations techniques to produce high sensitivity enhancements recorded between the years 1990-2010.  相似文献   

14.
In this paper, the use of an ion-pairing reagent to improve the separation selectivity of inorganic anions in CZE was demonstrated by the addition of tetramethylammonium hydroxide (TMAOH) to the electrolyte. The separation of inorganic anions (Cl(-), I(-), Br(-), NO(2)(-), NO(3)(-) and SCN(-)) was performed using co-electroosmotic flow (EOF) with direct UV detection at 185 nm. The parameters affecting the mobility of the tested anions and the EOF such as the electrolyte pH and concentration of TMAOH in the electrolyte were examined to optimise the separation conditions. In addition, sample-stacking techniques were investigated to improve detection sensitivity. Detection sensitivities were improved 5-13-fold using electrokinetic sample stacking. The detection limits ranged from 1-3 micro mol L(-1). Finally, the proposed method was used for the separation of anions in groundwaters.  相似文献   

15.
To improve detection sensitivity of cationic analytes, a dynamic pH junction technique was examined. Dynamic pH junction is an on-line focusing method in capillary electrophoresis (CE) based on the difference in the analyte's mobility between the background electrolyte (BGE) and sample matrix. The effects of pH values and concentrations of the BGE and the sample matrix on dynamic pH junction were examined. Optimization of analyte focusing resulted in enhanced detection responses of about 100-160-fold in terms of peak heights for some anilines in comparison to conventional injections. In particular, the concentration limits of detection (LOD) (S/N = 3) for the test anilines obtained with dynamic pH junction were from 1.9 to 3.7 ppb with UV detection without any pretreatment procedure.  相似文献   

16.
Breadmore MC 《Electrophoresis》2008,29(5):1082-1091
An online technique for stacking based on the generation of a stationary isotachophoretic (sITP) boundary is presented. By balancing the anodic migration of an ITP boundary with a cathodic EOF, a stationary boundary is formed that can be used to indefinitely concentrate analytes according to ITP principles during electrokinetic injection. The ITP boundary is created by using an electrolyte containing a leading ion (chloride) and a suitable terminating ion added to the sample (2-morpholinoethanesulphonic acid, MES). Destacking and separation are achieved simply by replacement of the sample vial with electrolyte. The formation and stabilisation of the sITP boundary were evaluated through computer simulation which revealed that the pH had little impact upon the formation of the sITP boundary, but did govern the position at which it becomes stationary. Simulations also demonstrated that similar results were obtained when the capillary was initially filled with sample/terminator or leader/electrolyte, which was also supported by experimental results. Using 100 mM Cl(-), 200 mM Tris, pH 8.05 as the leader/electrolyte and adding 100 mM MES, 200 mM Tris, pH 8.05 to the sample, the sITP boundary was established after 5 min at -20 kV and was stable for at least 60 min. This provided detection limits for NO(2) (-), NO(3) (-) and SCN(-) of 0.05-0.66 ppb, which are 10,000 times lower than hydrodynamic injection and 10-50 times lower than other stacking approaches used for these inorganic ions.  相似文献   

17.
We report an on-line sample preconcentration technique based on dynamic pH junction in capillary electrophoresis-mass spectrometry (CE-MS). For peptide analysis, the samples were dissolved in a solution with higher pH than the background solution (BGS), and were injected into the capillary as a long plug. The pH difference between the sample matrix and BGS caused changes in analytes' mobilities during electrophoresis, resulting in narrowing of their bands at the boundary. Around 550-1000-fold sensitivity enhancement could be achieved in terms of peak intensity without degrading peak shape and resolution. This technique is easy to perform and will be useful for peptide mass fingerprinting in protein analysis.  相似文献   

18.
A capillary electrophoresis method with UV-absorbance detection was studied and optimized for the determination of underivatized amino acids in urine. To improve concentration sensitivity the utility of in-capillary analyte stacking via dynamic pH junction was investigated with phenylalanine (Phe) and tyrosine (Tyr) as model amino acids. Before sample injection, a plug of ammonium hydroxide solution was injected to enable analyte concentration. Samples were 1:1 (v/v) mixed with background electrolyte (1 M formic acid) prior to injection. The effect of the injected sample volume, and the injected ammonium hydroxide volume and concentration on analyte stacking and separation performance was investigated. The optimal volume of ammonium hydroxide depended on the injected sample volume. Using a dynamic pH junction good resolution (1.4) was obtained for a sample injection volume of 10% of the capillary (196 nl) with Phe and Tyr dissolved in water. Limits of detection (LODs) were 0.036 and 0.049 μM for Phe and Tyr, respectively. For urine samples, the optimized procedure comprised a 1.7-nl injection of 12.5% ammonium hydroxide, followed by a 196-nl injection of urine spiked with Phe and Tyr. Satisfactory resolution was obtained and amino acid peak widths at half height were only 1.6 s indicating efficient stacking. Calibration plots for Phe and Tyr in urine showed good linearity (R(2) > 0.96) in the concentration range 10-175 μM, and LODs for Phe and Tyr were 0.054 and 0.019 μM, respectively. RSDs for peak area and migration time for Phe and Tyr were below 7.5% and 0.75%, respectively.  相似文献   

19.
In this work, a CZE method with indirect UV detection was developed for the simultaneous determination of the inorganic and acidic anions, chloride, sulfate, nitrate, fluoride, formate, phosphate, diethylphosphate, methyl sulfonate, cyanoacetate, and methacrylate present in cyanoacrylate adhesives. Chromate was employed as the probe ion, and the EOF was reversed by incorporating CTAB into BGE. Detection limits of 0.7-4.6 microg/mL were obtained for all the anions studied. The CE method developed is a significant improvement on traditionally used chromatographic methods such as ion chromatography, as it resulted in shorter analysis times with enhanced separation efficiencies. This method was successfully employed for the analysis of inorganic and acidic anions in cyanoacrylate adhesive samples.  相似文献   

20.
A pressurized liquid junction nanoelectrospray interface was designed and optimized for reliable on-line CE-MS coupling. The system was constructed as an integrated device for highly sensitive and selective analyses of proteins and peptides with the separation and spray capillaries fixed in a pressurized spray liquid reservoir equipped with the electrode for connection of the electrospray potential. The electrode chamber on the injection side of the separation capillary and the spray liquid reservoir were pneumatically connected by a Teflon tube filled with pressurized nitrogen. This arrangement provided precisely counterbalanced pressures at the inlet and outlet of the separation capillary. The pressure control system was driven by an electrically operated valve and maintained the optimum flow rate for the electrospray stability. All parts of the interface being in contact with the CEBGE, spray liquid and/or sample were made of glass or Teflon. The use of these materials minimized the electrospray chemical noise often caused by plastic softeners or material degradation. During optimization, the transfer of the separated zones between the separation and electrospray capillaries was monitored by UV absorbance and contactless conductivity detectors placed at the outlet of the separation capillary and inlet of the electrospray tip, respectively. This arrangement allowed independent monitoring of the effects of pressure, CE voltage and geometry of the liquid junction on the spreading and dilution of the separated zones after passage through the interface.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏