首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A microwave-assisted double insert multimode vapour-phase digestion method was developed for the digestion of organic samples. The experimental set-up was based on a third generation-type teflon microwave vessel, equipped with an automatic pressure regulating type vessel cover. A borosilicate glass holder insert, containing a smaller quartz sample insert, was fitted inside the vessel. Sulphuric acid was added to the holder insert as a microwave absorbing and temperature transferring liquid, which transferred heat to the sample insert (into which the sample was weighed) and charred the sample material. Oxidation of the sample material was carried out simultaneously with charring using nitric acid vapour, which was generated by the 1:1 (v/v) sulphuric acid-nitric acid mixture located in the bottom of the microwave vessel. This set-up generated high digestion efficiency, without any of the interferences normally associated with direct sulphuric acid usage. The method was used for determining the concentrations of Cd, Cr, Cu, Mn, Mo, Zn and Fe in certified organic reference materials using ICP-OES instrumentation. The certified organic reference materials were NRCC DOLT-2 dogfish liver, NIST-SRM 1577b bovine liver and IRMM VDA cadmium in polyethylene No. 001 and No. 004. The results were in good agreement with the certified values, forepart from Cd. For Cd the results were lower than the certified values due to volatilization losses. Sample materials that could not be digested by an earlier procedure were completely digested during a single-step, 30 min digestion. The tested sample materials included certified reference materials, 3-nitrobenzoic acid (3-NBA) and pike (Esox lucius) muscle. The residual carbon concentrations in the digestion solutions were below the detection limit of the TOC instrument. This type of digestion method is described here for the first time in the literature.  相似文献   

2.
The Plackett-Burman saturated factorial design was used to select optimized dissolution conditions for sewage sludge samples. Three different digestion methods were applied: i) microwave oven digestion in a domestic oven with Parr-type reactors; ii) microwave oven digestion with controlled-pressure reactors; iii) pressure bomb reactor heated on a hot plate. The three methods were validated by statistically comparing the metal contents found with the certified ones of the sewage sludge sample (BCR 145R). No significant differences were obtained and the RSD values were lower than 3% in all cases. The metals were determined by flame-AAS. The variables studied were the following: microwave power; digestion time; predigestion; volume of hydrochloric acid; volume of hydrofluoric acid; volume of nitric acid. The operative advantages offered by microwave digestion with controlled-pressure reactors were also considered. Received: 23 July 1997 / Revised: 31 October 1997 / Accepted: 5 November 1997  相似文献   

3.
The Plackett-Burman saturated factorial design was used to select optimized dissolution conditions for sewage sludge samples. Three different digestion methods were applied: i) microwave oven digestion in a domestic oven with Parr-type reactors; ii) microwave oven digestion with controlled-pressure reactors; iii) pressure bomb reactor heated on a hot plate. The three methods were validated by statistically comparing the metal contents found with the certified ones of the sewage sludge sample (BCR 145R). No significant differences were obtained and the RSD values were lower than 3% in all cases. The metals were determined by flame-AAS. The variables studied were the following: microwave power; digestion time; predigestion; volume of hydrochloric acid; volume of hydrofluoric acid; volume of nitric acid. The operative advantages offered by microwave digestion with controlled-pressure reactors were also considered. Received: 23 July 1997 / Revised: 31 October 1997 / Accepted: 5 November 1997  相似文献   

4.
Araújo GC  Nogueira AR  Nóbrega JA 《The Analyst》2000,125(10):1861-1864
A single vessel procedure using a focused microwave oven is proposed for biological sample preparation with nitric acid vapour under atmospheric pressure. A laboratory-made PTFE support vessel equipped with four cups that received the samples was adapted to fit on the microwave glass vessel. Biological samples (30 mg) were directly weighed into these PTFE cups followed by the addition of 150 microliters of water or H2O2. The mixture was exposed to acid vapour stemming from 15 ml of concentrated HNO3 placed in the bottom of the glass vessel. The acid vapour was formed at 115 degrees C and brought about the Co and Fe extraction in 10 and 60 min, respectively. The resulting suspension was diluted with 0.14 mol l-1 HNO3 to a final volume of 1.0 ml, shaken and centrifuged. The supernatant was analysed by electrothermal atomic absorption spectrometry (ETAAS) by placing the cups directly in the autosampler of the spectrometer. This system minimised contamination, and reagent and time consumption and was suitable for Co and Fe determination in biological materials. The accuracy of the proposed method was assessed by using certified reference materials and by comparison with the closed vessel microwave as a comparative technique. Cobalt and Fe recovery was around 82-99%. As an additional advantage, up to 6 samples can be simultaneously prepared in each vessel, thereby improving the sample throughput from 6 to 24, when a 6-cavity focused microwave is used.  相似文献   

5.
A microwave heated, vapor-phase nitric acid-hydrogen peroxide digestion method for pulverized, biological sample materials was developed. Sample masses up to 200 mg were digested using calibrated quartz inserts inside first generation type, low-pressure, Teflon-PFA microwave vessels. In the first step, samples were digested in the vapor-phase for 80 min using a progressive heating pattern. Three mL of 70% nitric acid and 0.5 mL of 30% hydrogen peroxide were used as digestion reagents. In the second step, the small residue left after first step digestion was dissolved in 1.4% nitric acid or additionally with 0.5% hydrofluoric acid by heating for 15 min. The digestion method was optimized using pike (Esox lucius) muscle as a test material. The method was further optimized using three certified reference materials. Ca, Cu, Fe, Mg and ¶Zn were determined from NIST-SRM 1577a bovine liver by ICP-AES. Cr and Ni were determined from NIST-SRM 8433 corn bran and NRCC DOLT-2 dogfish liver by GFAAS. For all elements the values obtained were close or within certified limits. Spike recoveries were between 96 to 107%. Digestion efficiency ranged from 91 to 99%.  相似文献   

6.
A microwave heated, vapor-phase nitric acid-hydrogen peroxide digestion method for pulverized, biological sample materials was developed. Sample masses up to 200 mg were digested using calibrated quartz inserts inside first generation type, low-pressure, Teflon-PFA microwave vessels. In the first step, samples were digested in the vapor-phase for 80 min using a progressive heating pattern. Three mL of 70% nitric acid and 0.5 mL of 30% hydrogen peroxide were used as digestion reagents. In the second step, the small residue left after first step digestion was dissolved in 1.4% nitric acid or additionally with 0.5% hydrofluoric acid by heating for 15 min. The digestion method was optimized using pike (Esox lucius) muscle as a test material. The method was further optimized using three certified reference materials. Ca, Cu, Fe, Mg and Zn were determined from NIST-SRM 1577a bovine liver by ICP-AES. Cr and Ni were determined from NIST-SRM 8433 corn bran and NRCC DOLT-2 dogfish liver by GFAAS. For all elements the values obtained were close or within certified limits. Spike recoveries were between 96 to 107%. Digestion efficiency ranged from 91 to 99%.  相似文献   

7.
Inductively coupled plasma mass spectrometry analysis of trace and major elements of mussel tissues can be quickly and accurately analyzed after cleaning up the interfering fat content before the sample is digested in a microwave oven. Making use of experimental designs, the clean up procedure was achieved by the extraction of 1 g of freeze-dried tissue sample stirred with 5 ml of dichloromethane during five minutes. The microwave assisted digestion of the fat free samples was carried out with 0.2 g of tissue sample, 15 ml of 7.0% nitric acid with a power of 980 W during 18 min. The analytical method efficiency (accuracy and precision) was evaluated with a CRM: (NIST 2977, mussel tissue) and real mussel samples analyzed previously. The results confirmed the accuracy of the analysis by agreement with the previous results but the precision was significantly improved. The developed method allows operating routinely permitting to large numbers of samples to be quickly screened for trace metals.  相似文献   

8.
Milk samples can be efficiently digested using a focused microwave oven, however the conventional procedure of addition of concentrated acids to the liquid sample leads to digestates with elevated acidity and residual carbon concentrations. In this work a focused microwave oven was applied for acid digestion of bovine milk samples using a conventional and an alternative procedure based on gradual sample addition to hot and concentrated acids. A two-level 23 full factorial design experiment with eight runs was carried out to evaluate the optimum experimental conditions for reducing both the residual carbon and the final acidity of digestates. The three studied parameters were: temperature of the digestion medium for sample addition, addition of sulfuric acid before the sample or during the first step, and number of aliquots of the sample gradually added. The best conditions were attained by adding small aliquots of milk (ten-fold a volume of 0.5 ml added during 5.0 min) to a digestion mixture containing 3.0 ml nitric acid plus 1.0 ml sulfuric acid heated at 105 °C. It was demonstrated that the digestion efficiency of the alternative procedure was better than the conventional procedure, i.e. 98 and 80%, respectively. The alternative procedure was applied for determination of Ba, Ca, Cu, K, Mg, Na, P, and Zn in whole and non-fat bovine milk. The accuracy was proved using two certified reference materials (whole and non-fat milk powder).  相似文献   

9.
A new and fast procedure is proposed for cleaning autosampler cups using acid-vapor steam-cleaning with a miniaturized assembly in a microwave-heated sealed Teflon vessel. A glass cactus-shaped holder was made to support six polyethylene autosampler cups (volume, 2.0 mL) inside a 100 mL microwave vessel. Regent-grade nitric acid was added to the vessels, and the system was heated in a microwave oven for 5 min at 300 W. Chromium was determined by graphite-furnace atomic-absorption spectrophotometry. The blank values were lower with cleaned cups compared to untreated cups (i.e., as received from supplier). The quantification limits, estimated from detection limits established with Milli-Q water, were 0.66 and 0.95 μg Cr L−1 for cleaned and untreated auto-sampler cups, respectively.  相似文献   

10.
A method was developed for high-throughput determinations of 7 elements in food samples, namely antimony (Sb), arsenic (As), cadmium (Cd), chromium (Cr), lead (Pb), mercury (Hg), and tin (Sn). The samples were digested by closed-vessel microwave-assisted digestion using concentrated nitric acid (HNO3) as the medium, followed by microwave- assisted evaporation to concentrate the sample solutions before dilution to the desired volume. The microwave-assisted evaporation procedure effectively reduced the final acid concentration to around 8% before analysis by inductively coupled plasma-mass spectrometry (ICP-MS). This reduction allows determination by ICP-MS to proceed without further sample dilution, which would affect the detection limit. The method was validated, and method recoveries for As, Cd, Cr, Pb, and Hg were within the certified ranges of the chosen certified reference materials. Recoveries of the 7 elements from spiked samples ranged from 93.1 to 103.6%. The standard uncertainties of precision for the 7 elements were between 3.1 and 4.3%. Interlaboratory comparison studies for As, Cd, and Pb gave z-scores ranging from -0.2 to 0.3.  相似文献   

11.
Investigations of microwave assisted drying of sample materials and microwave assisted evaporation of aqueous sample solutions and acidic digestion residues were accomplished by means of special rotors for the microwave digestion system MULTIWAVE. To check the results obtained by microwave assisted drying, the samples were also conventionally dried at 105 degrees C in an oven. The following samples have been dried: 10 g each of meat, fish, apple, cucumber, potato, mustard, yogurt, clay and marl; 1 g each of certified reference material TORT 2 (lobster hepatopancreas), BCR 278 (mussel tissue) and BCR 422 (cod muscle); 500 g garden mould. Microwave assisted drying takes 40 min for organic samples and 30 min for inorganic material. Important is a slow increase of microwave power during the first 20 min. The results agree well with conventional drying at 105 degrees C. Losses of As, Se and Hg have been investigated for 3 CRMs. Only Se shows losses in the range of 20%. Losses of As, Be, Cd, Co, Cr, Cu, Fe, Hg, Li, Mg, Mn, Mo, Ni, Pb, Sb, Se, Sr, Ti, Tl, V and Zn after evaporation of aqueous samples and acidic solutions after wet digestion, respectively, have been investigated. 50 mL aqueous solution was evaporated almost to dryness within 25 min. The recovery of Hg is 40-50%, of Se 90-95% and of the other elements 97-102%. 0.2 g each of TORT 2, BCR 278 and BCR 422 have been digested with 4 mL nitric acid and 1 mL hydrochloric acid by means of the microwave digestion system MULTIWAVE. The digestion residue was evaporated almost to dryness and dissolved again in 10 mL diluted nitric acid. In this case no element losses have been observed. The measured concentration of As, Cd, Cu, Fe, Mn, Hg, Pb, Mo, Ni, Se, Sr, V and Zn agree very well with the certified values. An important prerequisite for good recoveries is not to evaporate the solutions to complete dryness.  相似文献   

12.
选用银含量为3%、30%和70%的银锡焊料样品,分别经过三种不同前处理方法,采用硝酸、盐酸消解,应用电感耦合等离子体发射光谱法(ICP-OES)同时测定锡铅合金中镉、铅、汞3种重金属元素含量。实验研究了不同前处理方法对银锡合金中重金属测定的影响。实验表明消解实验中的共沉淀现象会对3种重金属元素的测定产生不利的影响,回收率不能满足要求;采用硝酸消解,过滤残渣经王水消解的方法,镉、铅、汞的7次测定重复性相对标准偏差在2.7%~5.5%、加标回收率在85.6%~103%,能够满足RoHS测试要求。  相似文献   

13.
A single-laboratory validation by inductively coupled plasma-mass spectrometry was developed for the determination total iodine (m/z 127) in infant formula and adult nutritional products. All samples were digested in nitric acid using a closed vessel microwave oven system; Te (m/z 130) was used as an internal standard. To prevent loss of iodine, ammonium hydroxide solution was added to the samples immediately after digestion. The method quantitation limit for total iodine was 0.3 ng/mL, but a practical LOQ was used at 1.0 ng/mL, a concentration at which there was a negligible bias due to nonlinearity. The total iodine concentrations (112-1900 ng/g) in 14 out of 15 nutritional products were within specification limits. Within-day and day-to-day (6 independent days) precision values were < 10% RSD. The observed precision for the overall mean (18 independent days) of a control sample was approximately 4% RSD. In two National Institute of Standards and Technology standard reference materials, total iodine results were within certified limits. Sample spike recoveries for all 15 nutritional products were 92-105%. The data show that a conventional microwave oven digestion procedure can be used to prepare samples for iodine determination. Therefore, this technique is very compatible with other methods being proposed as modern official methods for the analysis of minerals in nutritional products.  相似文献   

14.
Investigations of microwave assisted drying of sample materials and microwave assisted evaporation of aqueous sample solutions and acidic digestion residues were accomplished by means of special rotors for the microwave digestion system MULTIWAVE. To check the results obtained by microwave assisted drying, the samples were also conventionally dried at 105?°C in an oven. The following samples have been dried: 10 g each of meat, fish, apple, cucumber, potato, mustard, yogurt, clay and marl; 1 g each of certified reference material TORT 2 (lobster hepatopancreas), BCR 278 (mussel tissue) and BCR 422 (cod muscle); 500 g garden mould. Microwave assisted drying takes 40 min for organic samples and ¶30 min for inorganic material. Important is a slow increase of microwave power during the first 20 min. The results agree well with conventional drying at 105?°C. Losses of As, Se and Hg have been investigated for ¶3 CRMs. Only Se shows losses in the range of 20%. Losses of As, Be, Cd, Co, Cr, Cu, Fe, Hg, Li, Mg, Mn, Mo, Ni, Pb, Sb, Se, Sr, Ti, Tl, V and Zn after evaporation of aqueous samples and acidic solutions after wet digestion, respectively, have been investigated. 50 mL aqueous solution was evaporated almost to dryness within 25 min. The recovery of Hg is 40–50%, of Se 90–95% and of the other elements 97–102%. 0.2 g each of TORT 2, BCR 278 and BCR 422 have been digested with 4 mL nitric acid and 1 mL hydrochloric acid by means of the microwave digestion system MULTIWAVE. The digestion residue was evaporated almost to dryness and dissolved again in 10 mL diluted nitric acid. In this case no element losses have been observed. The measured concentration of As, Cd, Cu, Fe, Mn, Hg, Pb, Mo, Ni, Se, Sr, V and Zn agree very well with the certified values. An important prerequisite for good recoveries is not to evaporate the solutions to complete dryness.  相似文献   

15.
Closed microwave digestion and a high-pressure asher have been evaluated for wet-oxidation and extraction of lead, cadmium, chromium, and mercury from a range of typical packaging materials used for food products. For the high-pressure asher a combination of nitric and sulfuric acids was efficient for destruction of a range of packaging materials; for polystyrene, however, nitric acid alone was more efficient. For microwave digestion, a reagent containing nitric acid, sulfuric acid, and hydrogen peroxide was used for all materials except polystyrene. Use of the high-pressure asher resulted in the highest recoveries of spiked lead (median 92%), cadmium (median 92%), chromium (median 97%), and mercury (median 83%). All samples were spiked before digestion with 40 microg L(-1) Cd, Cr, and Pb and 8 microg L(-1) Hg in solution. The use of indium as internal standard improved the accuracy of results from both ICP-MS and ICP-AES. Average recovery of the four elements from spiked packaging materials was 92 +/- 14% by ICP-MS and 87 +/- 15% (except for mercury) by ICP-AES. For mercury analysis by CVAAS, use of tin(II) chloride as reducing agent resulted in considerably better accuracy than use of sodium borohydride reagent.  相似文献   

16.
Closed microwave digestion and a high-pressure asher have been evaluated for wet-oxidation and extraction of lead, cadmium, chromium, and mercury from a range of typical packaging materials used for food products. For the high-pressure asher a combination of nitric and sulfuric acids was efficient for destruction of a range of packaging materials; for polystyrene, however, nitric acid alone was more efficient. For microwave digestion, a reagent containing nitric acid, sulfuric acid, and hydrogen peroxide was used for all materials except polystyrene. Use of the high-pressure asher resulted in the highest recoveries of spiked lead (median 92%), cadmium (median 92%), chromium (median 97%), and mercury (median 83%). All samples were spiked before digestion with 40 μg L–1 Cd, Cr, and Pb and 8 μg L–1 Hg in solution. The use of indium as internal standard improved the accuracy of results from both ICP–MS and ICP–AES. Average recovery of the four elements from spiked packaging materials was 92 ± 14% by ICP–MS and 87 ± 15% (except for mercury) by ICP– AES. For mercury analysis by CVAAS, use of tin(II) chloride as reducing agent resulted in considerably better accuracy than use of sodium borohydride reagent.  相似文献   

17.
A method using differential pulse anodic stripping voltammetry after microwave oven digestion was developed for the simultaneous determination of Cd(II) and Pb(II) in the deciduous teeth of children. Each tooth was weighed; deposited in a 120 mL capped Teflon vessel with 5 mL 65% nitric acid, Suprapur analytical grade; and digested in a 2-step microwave oven for 15 min. The detection limits for Cd(II) and Pb(II) in the final solution were 0.078 and 0.323 microg/L, and the quantitation limits 0.394 and 1.613 microg/L, respectively, with a linearity range of 2 microg/L for Cd(II) and 23.3 microg/L for Pb(II). The sensitivity was 2.51 nA/microg-L and 1.37 nA/microg-L, for Cd(II) and Pb(II). The main advantages of this technique are a complete and satisfactory dissolution of the tooth material with the proposed microwave oven digestion procedure, without sample pretreatments, such as drying, ashing, or powdering. The voltammetric procedure proved to be well designed because of significant goodness of fit to a linear model, and the accuracy of the method was established as compared with standard reference material. The methodology has enabled us to study Cd(II) and Pb(II) in 371 deciduous teeth from school children in Cartagena, Spain.  相似文献   

18.
In this study a procedure for sample digestion based on sample combustion assisted by microwave radiation is proposed. Combustion is started by microwave radiation in the presence of oxygen under pressure using ammonium nitrate as aid for ignition. The system was adapted in a microwave oven with quartz closed vessels. A quartz piece is used simultaneously as a sample holder and as protection to the cap of quartz vessel from the flame generated in the combustion process. Sample was pressed into a pellet and placed on a disc paper in the holder and 50 μl of 50% m/v ammonium nitrate solution was added. The influence of the absorption solution (diluted and concentrated nitric acid or water) on the recoveries for Cu and Zn was evaluated. About 3 s of microwave irradiation was necessary to start the combustion. The combustion process was evaluated in relation to the influence of sample mass on the ignition time, combustion time and maximum operation pressure. Bovine liver, milk powder and oyster tissue certified reference materials were used to evaluate the accuracy of the procedure for determination of copper and zinc. Good agreement for zinc (96% to 103%) was obtained from bovine liver certified reference material when microwave combustion and microwave combustion followed by reflux were used to sample decomposition, even if water was used for absorption of analyte. For copper, the combustion followed by reflux of 5 min allows an agreement from 96% to 100%. Similar results were obtained for oyster tissue samples. However, for milk powder good agreement close to 100% was obtained only if 4 mol l− 1 HNO3 was used with a reflux step. Results from the proposed procedure were also compared to those from conventionally used procedures for biological samples decomposition, such as wet digestion in open vessels and microwave-assisted digestion in closed vessels. The advantages of this procedure include the complete sample decomposition in less time than other procedures and the acid consumption was always lower than 2%. Another advantage is the low residual carbon content, less of 1.4% without reflux and less than 0.3% with the reflux step and the possibility of use of diluted acid as absorbing solution. Moreover, the new holder allows an effective protection of the vessel cap to burnt high masses.  相似文献   

19.
Electrothermal atomic absorption spectrometry was used to determine aluminium and chromium in different types of baby foods. Samples without previous treatment were introduced into the atomizer as suspensions, which were prepared in a medium containing 0.1% (w/v) Triton X-100 (for chromium) or 10% (v/v) ethanol (for aluminium), 5% (v/v) concentrated hydrogen peroxide, and 0.5% (v/v) concentrated nitric acid. The slurries were homogenized with a potter and introduced directly into the furnace. The presence of nitric acid allowed a substantial amount of analyte to be extracted to the liquid phase. No matrix effect was observed and aqueous standard solutions were used for calibration. The detection limits were 4 and 50 pg for chromium and aluminium, respectively; characteristic masses were 3.8 pg for chromium and 18 pg for aluminium. Reliability of the procedures was checked by statistically comparing the results with those obtained with a previous microwave oven mineralization stage and by analyis of several certified reference materials. Values for the aluminium content ranged between 0.4 and 3.0 microg/g, and for chromium between 0.003 and 0.06 microg/g.  相似文献   

20.
Eilola K  Perämäki P 《The Analyst》2003,128(2):194-197
A previously developed microwave heated vapor-phase digestion method for biological samples was modified to enable digestion of difficult to digest organic samples. Organic samples containing ca. 100 mg of organic carbon were digested using volume calibrated quartz inserts inside second generation type medium pressure microwave vessels. As digestion reagents, 98% sulfuric acid, 70% nitric acid and 30% hydrogen peroxide were used. The accuracy of the method was tested with six certified reference materials. Elements Ca, Fe, K, Na, Mg, P and Zn were determined from NIST-SRM 8433 corn bran. Elements Al, Fe, Cd, Cu, and Zn were determined from NRCC DOLT-2 dogfish liver. The element Cd was determined from IRMM-VDA Cd in polyethylene No. 001-004 reference materials. These elements were determined from digested samples by ICP-OES. The results were close or within certified limits. The modified method could digest nearly all the materials tested, including the above mentioned reference materials, 2-nitrobenzoic acid (2-NBA), 4-NBA and copper(II) phthalosyanine-3, 4',4',4'-tetrasulfonic acid tetrasodium salt (CPS). The method could not digest 3-NBA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号