首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 88 毫秒
1.

Objective

The objective was to evaluate magnetic resonance imaging (MRI) issues (magnetic field interactions, heating, artifacts and functional alterations) at 1.5 T and 3 T for the Argus II Retinal Prosthesis (Second Sight Medical Products, Sylmar, CA, USA).

Materials and Methods

Standardized protocols were used to assess magnetic field interactions (translational attraction and torque; 3 T, worst case), MRI-related heating (1.5 and 3 T), artifacts (3 T; worst case) and functional changes (1.5 and 3 T) associated with MRI.

Results

The magnetic field interactions were acceptable. MRI-related heating, which was studied at a relatively high, MR system-reported whole body averaged specific absorption rates, will not pose a hazard to the patient under the conditions used for testing. While artifacts were “moderate” in relation to the dimensions of the Argus II Retinal Prosthesis, optimization of MRI parameters can reduce the size of the artifacts. Exposures to MRI conditions at 1.5 and 3 T did not damage or alter the functional aspects of the Argus II Retinal Prosthesis.

Conclusions

In consideration of the test results, a patient with the Argus II Retinal Prosthesis may undergo MRI at 1.5 T or 3 T when specific guidelines and MRI conditions are followed, including those advised by the manufacturer.  相似文献   

2.

Background and Purpose

Fine-mesh braided, stent-like structures (flow diverters) have been proposed for treatment of brain aneurysms. To date, the safety of performing magnetic resonance imaging (MRI) in patients with these implants is unknown. Therefore, the purpose of this study was to evaluate MRI issues at 3-T for a new flow-diverting implant used to treat brain aneurysms.

Methods

The Surpass NeuroEndoGraft (Surpass Medical, Ltd., Tel Aviv, Israel) underwent evaluation for magnetic field interactions, MRI-related heating and artifacts using standardized techniques. Magnetic field interactions were assessed for this implant with regard to translational attraction (i.e., using the deflection angle technique) and torque (qualitative assessment method). MRI-related heating was evaluated by placing the implant in a gelled-saline-filled, head/torso phantom and performing MRI using a transmit/receive radiofrequency body coil at a whole-body-averaged specific absorption rate of 2.9 W/kg for 15 min. Artifacts were characterized using T1-weighted, spin echo (SE) and gradient echo (GRE) pulse sequences.

Results

The Surpass NeuroEndoGraft exhibited minor magnetic field interactions (21° deflection angle and no torque), which were acceptable from a safety consideration. Heating was not substantial, with the highest temperature change being 2.3°C (background temperature rise without the implant was 1.5°C). Artifacts may create issues if the area of interest is in the same area or close to this implant.

Conclusions

The findings demonstrated that it would be acceptable for patients with this next-generation, flow-diverting implant to undergo MRI at 3-T or less.  相似文献   

3.

Objective

Coronary artery stents are made from metallic mesh and, therefore, to ensure patient safety, these implants must be evaluated to determine risks associated with MRI. Recently, bioabsorbable scaffolds, which have metallic markers, have been developed for use in the coronary arteries. Because of the metallic materials, these implants may present issues for patients undergoing MRI. Therefore, the objective of this investigation was to assess MRI issues (i.e., magnetic field interactions, MRI-related heating, and artifacts at 3 T) for a new bioabsorbable, coronary artery scaffold with metallic markers.

Methods

A bioabsorbable, coronary artery scaffold (Mirage Microfiber Scaffold) underwent assessments for magnetic field interactions, MRI-related heating, and artifacts at 3-Tesla using standard techniques. MRI-related heating was evaluated with the scaffold placed in a gelled-saline-filled phantom and MRI was performed at an MR system reported, whole body averaged SAR of 2.9 W/kg for 15 minutes. Artifacts were characterized using T1-weighted spin echo and gradient echo, pulse sequences.

Results

There were no magnetic field interactions. The highest temperature rise was 1.6 °C (highest background temperature rise, 1.6 °C). Artifacts were relatively small in relation to the size and shape of this coronary artery scaffold. Notably, the lumen of the scaffold could be visualized on the GRE pulse sequence.

Conclusion

The results demonstrated that the coronary artery scaffold is acceptable (or “MR conditional,” using current MRI labeling terminology) for a patient undergoing an MRI procedure at 3 T or less. To our knowledge, this is the first bioabsorbable, coronary artery scaffold that has been evaluated for MRI issues.  相似文献   

4.

Objective

Vascular grafting frequently involves a time-consuming operation. A new vascular coupling device (VCD) made from metallic material was recently developed that may be advantageous because of the reduced operative time and decreased patient risks. Because of the metal, there are safety concerns related to MRI. Therefore, the purpose of this investigation was to use standardized testing techniques to evaluate MRI issues for this VCD in association with a 3-Tesla MR system.

Methods

The VCD (corlife oHG, Hannover, Germany) was evaluated for magnetic field interactions (translational attraction and torque), MRI-related heating, and artifacts at 3-Tesla. MRI-related heating was assessed with the VCD in a gelled-saline-filled phantom with MRI performed at a whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were assessed using T1-weighted, spin echo, and gradient echo pulse sequences.

Results

The VCD exhibited minor magnetic field interactions and minimal heating (maximum temperature elevation, 1.8 °C). Artifacts were relatively small in relation to the size and shape of this implant. The lumen of the VCD could not be visualized using the gradient echo pulse sequence.

Conclusions

The metallic VCD that underwent evaluation is MR conditional for a patient undergoing an MRI procedure at 3-Tesla or less.  相似文献   

5.

Objectives

A patient with a breast tissue expander may require a diagnostic assessment using magnetic resonance imaging (MRI). To ensure patient safety, this type of implant must undergo in vitro MRI testing using proper techniques. Therefore, this investigation evaluated MRI issues (i.e., magnetic field interactions, heating, and artifacts) at 3-Tesla for a breast tissue expander with a remote port.

Methods

A breast tissue expander with a remote port (Integra Breast Tissue Expander, Model 3612-06 with Standard Remote Port, PMT Corporation, Chanhassen, MN) underwent evaluation for magnetic field interactions (translational attraction and torque), MRI-related heating, and artifacts using standardized techniques. Heating was evaluated by placing the implant in a gelled-saline-filled phantom and MRI was performed using a transmit/receive RF body coil at an MR system reported, whole body averaged specific absorption rate of 2.9-W/kg. Artifacts were characterized using T1-weighted and GRE pulse sequences.

Results

Magnetic field interactions were not substantial and, thus, will not pose a hazard to a patient in a 3-Tesla or less MRI environment. The highest temperature rise was 1.7 °C, which is physiologically inconsequential. Artifacts were large in relation to the remote port and metal connector of the implant but will only present problems if the MR imaging area of interest is where these components are located.

Conclusions

A patient with this breast tissue expander with a remote port may safely undergo MRI at 3-Tesla or less under the conditions used for this investigation. These findings are the first reported at 3-Tesla for a tissue expander.  相似文献   

6.

Background and Purpose

A new neurological implant, the Sensor-Reservoir, was developed to provide a relative measurement of ICP, which permits a noninvasive technique to detect and localize occlusions in ventricular drainage systems and, thus, to identify mechanical damage to shunt valves. The “reservoir” of this device can be used to administer medication or a contrast agent, to extract cerebral spinal fluid (CSF), and with the possibility of directly measuring ICP. The Sensor-Reservoir was evaluated to identify possible MRI-related issues at 1.5-T/64-MHz and 3-T/128-MHz.

Materials and Methods

Standard testing techniques were utilized to evaluate magnetic field interactions (i.e., translational attraction and torque), MRI-related heating, and artifacts at 3-T for the Sensor-Reservoir. In addition, 12 samples of the Sensor-Reservoir underwent testing to determine if the function of these devices was affected by exposures to various MRI conditions at 1.5-T/64-MHz and 3-T/128-MHz.

Results

Magnetic field interactions for the Sensor-Reservoir were not substantial. The heating results indicated a highest temperature rise of 1.8 °C, which poses no patient risks. Artifacts were relatively small in relation to the size and shape of the Sensor-Reservoir, but may interfere diagnostically if the area of interest is near the device. All devices were unaffected by exposures to MRI conditions at 1.5-T/64-MHz and 3-T/128-MHz.

Conclusion

When specific guidelines are followed, the Sensor-Reservoir is “MR conditional” for patients undergoing MRI examinations at 3-T or less.  相似文献   

7.

Background

Since the advent of magnetic resonance imaging, metal artifacts have posed an important diagnostic problem in different fields of medicine. However, this has not been systematically studied in patients undergoing surgery for brain tumors.

Objective

This study was planned to assess whether metal artifacts can occur in patients undergoing brain surgery without metallic implants.

Methods

Of 40 individuals who could be included because of having a pre- and postoperative MRI and a postoperative computed tomography (CT) scan or a conventional skull X-ray for the detection of metallic artifacts, 26 patients agreed to participate in this study and gave informed consent.

Results

Twenty-six subjects, 12 males and 14 females, with an age range of 12 to 54 years, were included in the study. Four patients were found to have gross metal particles in their postoperative brain CTs and were excluded. Of the remaining 22 subjects, 7 patients (31.8%) had metallic artifacts.

Conclusion

Our study showed that simple bone drilling or chiseling during surgical manipulation of skull bones may result in separation of very tiny metal particles which can remain in the surgical site and cause artifacts in postoperative MRIs. This finding appeared to be independent of factors such as age, sex, tumor/incision site, tumor size, pathologic tumor type, total radiation dose, operation–MRI time interval and sequence of MRI.  相似文献   

8.

Purpose

To evaluate MRI artifacts at 3-Tesla for 38 commonly used cosmetics.

Materials and Methods

Thirty-eight cosmetics (16, nail polishes; 5, eyeliners; 3, mascaras; 10, eye shadows; 1, lip gloss; 1, body lotion; 1, body glitter, and 1, hair loss concealer) underwent evaluation for MRI artifacts at 3-Tesla. The cosmetics were applied a copper-sulfate-filled, phantom and initially assessed using a “screening” gradient echo (GRE) pulse sequence. Of the 38 different cosmetics, 14 (37%) exhibited artifacts. For these 14 cosmetics, additional characterization of artifacts was performed using a GRE pulse sequence. A qualitative scale was applied to characterize the artifact size.

Results

Artifacts were observed, as follows: 2, nail polishes; 5, eyeliners; 3, mascaras; 3, eye shadows; 1, hair loss concealer. Artifact size ranged from small (eye shadow) to very large (hair loss concealer) and tended to be associated with the presence of iron oxide or other metal-based ingredient.

Conclusions

Commonly used cosmetics caused artifacts that may create issues if the area of interest is the same as where the cosmetic was applied or if its presence was unknown, thus, potentially causing it to be construed as pathology. Therefore, these findings have important implications for patients referred for MRI examinations.  相似文献   

9.

Purpose

To optimize the navigator-gating technique for the acquisition of high-quality three-dimensional spoiled gradient-recalled echo (3D SPGR) images of the liver during free breathing.

Materials and methods

Ten healthy volunteers underwent 3D SPGR magnetic resonance imaging of the liver using a conventional navigator-gated 3D SPGR (cNAV-3D-SPGR) sequence or an enhanced navigator-gated 3D SPGR (eNAV-3D-SPGR) sequence. No exogenous contrast agent was used. A 20-ms wait period was inserted between the 3D SPGR acquisition component and navigator component of the eNAV-3D-SPGR sequence to allow T1 recovery. Visual evaluation and calculation of the signal-to-noise ratio were performed to compare image quality between the imaging techniques.

Result

The eNAV-3D-SPGR sequence provided better noise properties than the cNAV-3D-SPGR sequence visually and quantitatively. Navigator gating with an acceptance window of 2 mm effectively inhibited respiratory motion artifacts. The widening of the window to 6 mm shortened the acquisition time but increased motion artifacts, resulting in degradation of overall image quality. Neither slice tracking nor incorporation of short breath holding successfully compensated for the widening of the window.

Conclusion

The eNAV-3D-SPGR sequence with an acceptance window of 2 mm provides high-quality 3D SPGR images of the liver.  相似文献   

10.

Purpose

To test a magnetic resonance image (MRI) technique that uses an additional pulse in multi-echo T2* sequence that works to suppress the fat signal, in subjects with liver iron overload and concomitant presence of fat in the liver, which have been revealed as a major drawback that compromises the correct iron quantification by MRI.

Materials and Methods

Fifty magnetic resonance images of the liver (1.5 T scanner) of individuals with blood ferritin increases were retrospectively reviewed for the presence of steatosis, using the sequence in and out of phase, and iron overloading, using two sequences T2 * multi-echo: one standard and other with additional fat suppression pulse. T2 * values and their standard deviations were analyzed statistically.

Results

Our results showed that a significantly lower standard deviation of T2* values is obtained when the fat saturation pulse is applied in patients with steatosis. We found that modulation of fat signal on liver iron overload resulted in a different categorization of some patients. In one case, the patient was re-classified within normal levels of liver iron.

Conclusion

Our findings may contribute to a better measure of liver iron overload with relevant implications for patient treatment and care.  相似文献   

11.

Background

Acute symptomatic inflammation is a main feature of multiple sclerosis but pathophysiological processes underlying total or partial recovery are poorly understood.

Objective

To characterize in vivo these processes at molecular, structural and functional levels using multimodal MR methods.

Methods

A neuroimaging 3-year follow-up (Weeks 0, 3, 11, 29, 59 and 169) was conducted on a 41-year-old woman presenting at baseline with a large acute demyelinating lesion of multiple sclerosis. Conventional magnetic resonance imaging (MRI), magnetization transfer imaging, diffusion-weighted imaging, functional MRI and magnetic resonance spectroscopy were conducted at 1.5 T.

Results

Patient presenting with subacute left hemiplegia recovered progressively (expended disability status scale 7 to 5.5). The MR exploration demonstrated structural functional and metabolic impairments at baseline. Despite restoration of the blood brain barrier integrity, high lactate levels persisted for several weeks concomitant with glial activation. Slow and progressive structural and metabolic restorations occurred from baseline to W169 (lesion volume −64%; apparent diffusion coefficient −14.7%, magnetization transfer ratio +14%, choline −51%, lipids −78%, N-acetylaspartate +77%) while functionality of the motor system recovered.

Conclusions

Multimodal MRI/MRS evidenced long-term dynamics recovery processes involving tissue repair, glial activation, recovery of neuronal function and functional systems. This may impact on customized rehabilitation strategies generally focused on the first months following the onset of symptoms.  相似文献   

12.

Objective

The cause of enophthalmos as a late complication after orbital reconstruction is poorly investigated. Multislice CT (MSCT) is usually employed for its assessment, in spite of limitations regarding soft tissue depiction/imaging, as well as the implication of radiation and production of artifacts. Magnetic resonance imaging (MRI) has been shown to be a valuable alternative. The aim of this study was to establish a bony and soft tissue orbital volume calculation method based on different high-resolution MRI sequences compared to MSCT.

Materials and Methods

Thirty-seven patients were included in this prospective study investigating the origin of enophthalmos present 3–4 months after complex orbital reconstruction. Morphological and dimensional changes of the orbit, eye globes, extraocular muscles and fat content were investigated 3–4 months after surgery. To assess the site and size of bony and soft tissue changes in the traumatized orbits, we used MSCT and MR images as well as corresponding 3-D reconstructions.

Results

All enophthalmic orbits revealed a significant bony volume increase compared to the contralateral side as well as a reduced sagittal eye projection. Mean orbital volume enlargements of 1.0 cm3 lead to 0.93 mm enophthalmos (P<.05). Hardly any fatty atrophy could be depicted by the different MRI techniques.

Conclusions

For soft tissue depiction of the orbit, MRI was superior to MSCT. Particularly, proton density weighting proved to be the best sequence for soft tissue volume segmentation, allowing determination of the cause and degree of posttraumatic enophthalmos in reconstructed orbits.  相似文献   

13.

Purpose

Lesions close to the internal craniocervical ligaments are a common problem in patients with whiplash injuries. The aim of this study was to evaluate the morphology and visibility of these ligamentous structures with a new isotropic three-dimensional (3D) turbo-spin-echo (TSE) technique.

Materials and Methods

MR (MR) images of the cervical spine of 52 healthy subjects (27 women and 25 men; mean age=29 years; age range=18–40 years) were taken with a T2-weighted 3D TSE sequence with variable flip-angle distribution [SPACE (Sampling Perfection with Application optimized Contrasts using different flip-angle Evolution)] at 1.5 T (Magnetom Avanto, Siemens Erlangen, Germany). Two experienced musculoskeletal radiologists read the images independently on a 3D imaging and postprocessing workstation. The visibility and morphology of the alar ligaments were evaluated on a five-point scale, and inter-reader correlation was assessed with kappa statistics.

Results

Both alar ligaments were detected in all subjects. Twenty-eight (53.8%) of the alar ligaments could not be seen within one slice of the standard coronal imaging plane but could adequately be visualized in an oblique reconstruction adapted to the orientation of the ligaments on the axial slices. Inter-reader correlation for visibility on MR imaging (MRI) of the internal craniocervical ligaments was high (left+right side, kappa=0.95). Most (94%) alar ligaments presented symmetrically. In the axial plane, 60% were oriented neutral and 40% had a backward orientation. In the coronal plane, 67% were oriented caudocranially and 33% were oriented horizontally. The shape of the ligaments was parallel in half and was V-shaped in the other half. The alar ligaments had homogeneous low-signal intensity in 56% and heterogeneous low-signal intensity in 44%. The apical ligament of the dens was seen (excellent–good–moderate) in 61% (reader 1) and 52% (reader 2). The tectorial membranes and the transverse ligament of the atlas were shown (excellent–good) in all subjects.

Conclusions

MRI with acquisition of an isotropic SPACE technique allows high-resolution imaging of the craniocervical ligaments in all orientations. Reconstruction of the image data in the variable orientation of the alar ligaments allowed for excellent depiction within one slice such that partial volume artifacts that hamper image analysis can be eliminated.  相似文献   

14.

Introduction

To clarify the mechanism underlying apparent diffusion coefficient (ADC) changes in regional intracranial tissue during the cardiac cycle, we investigated relationships among ADC changes, volume loading, and intracranial pressure using a hemodialyzer phantom in magnetic resonance imaging (MRI).

Materials and Methods

The hemodialyzer phantom consisted of hollow fibers (HF), the external space of HFs (ES), and a gateway of dialysis solution, filled with syrup solution and air. The high-volume and low-volume loadings were periodically applied to HFs by a to-and-fro flow pump, and syrup solution was permitted to enter or leave HFs during the volume loading cycles. ADC maps at each volume loading phase were obtained using ECG-triggered single-shot diffusion echo-planar imaging. Dynamic phase contrast MRI was also used to measure volume loading to the phantom. We compared the ADC changes, volume loading, and intracranial pressure in the phantom during the cardiac cycle.

Results

ADC changes synchronized significantly with absolute volumetric flow rate change. The maximum ADC change was higher in high-volume loading cycles than in low-volume loading cycles. Results showed that the water molecules in ES fluctuated according to the force transferred from HF to ES. ADC changes were dependent upon the volumetric flow rate during the cardiac cycle.

Conclusions

Our original phantom allowed us to clarify the mechanism underlying water fluctuations in intracranial tissues. Measurement of maximum changes in ADC is an effective method to define the transfer characteristics of the arterial pulsatile force in regional intracranial tissue.  相似文献   

15.

Purposes

To evaluate the diagnostic value of diffusion-weighted MRI (DWI) and combination of conventional MRI and DWI to predict metastatic axillary lymph nodes in breast cancer.

Materials and methods

Two hundred fifty-two breast cancer patients with 253 axillae were included. The morphological parameters on axial T2-weighted images without fat saturation and apparent diffusion coefficient (ADC) values were retrospectively analyzed. An independent t-test/chi-square test and receiver operating characteristics (ROC) curve analysis were used.

Results

On conventional MRI, short and long axis length, maximal cortical thickness, relative T2 value, loss of fatty hilum (p < 0.001 for each), and eccentric cortical thickening (p < 0.003) were statistically significantly different between the metastatic and nonmetastatic groups. The short axis to long axis ratio was not a statistically significant parameter. The ADC value was significantly different between the 2 groups, with an AUC that was higher than that of conventional MR parameters (AUC, 0.815; threshold, ≤ 0.986 × 10–3 mm2/sec; sensitivity, 75.8%; specificity, 83.9%). Using the adopted thresholds for each parameter, a total number of findings suggesting malignancy of 4 or higher was determined as the threshold, with high specificity (90.1%).

Conclusion

Using conventional MRI and DWI, we can evaluate the axilla in breast cancer with high specificity.  相似文献   

16.

Objective

Equivalent cross-relaxation rate imaging (ECRI) is an MRI technique used to evaluate qualitative changes in protein-water interactions. We aimed to prospectively evaluate the utility of ECRI for classification of adipocytic tumors.

Materials and Methods

Institutional Review Board approval was obtained and all patients provided informed consent. Study participants included 40 patients with adipocytic tumors who were diagnosed with lipomas (n = 22), atypical lipomatous tissue/well-differentiated liposarcoma (ALT/WDL; n = 9), myxoid/round cell liposarcoma (MyL; n = 6), and dedifferentiated liposarcoma (DDL; n = 3), and 20 control patients for whom subcutaneous fat in the buttock or thigh was analyzed.

Results

Mean ECR values of lipomas, ALT/WDL, and subcutaneous fat were low, and those of MyL and DDL were high. Mean ECR values of MyL and DDL were significantly higher than those of ALT/WDL. The cut-off value was 5.1%. There was a positive correlation between ECR value, pathological grade, and cell density in adipocytic tumors.

Conclusion

The ECR value positively correlates with pathological grade and cell density of adipocytic tumors. Our findings suggest that ECRI is a useful method for preoperative evaluation of adipocytic tumors.  相似文献   

17.

Purpose

To investigate the influence of dual-source parallel radiofrequency (RF) excitation on clinical breast MR images.

Methods

A 3 T MR system with both dual-source and conventional single-source RF excitations was used to examine 22 patients. Axial TSE-T2WI with fat suppression, TSE-T1WI without fat suppression, THRIVE (3D field echo) and DWI (SE-EPI) were obtained by using both excitation techniques. Image homogeneity, image contrast and lesion conspicuity were measured or independently scored by two radiologists and were compared by paired-sample t test or Wilcoxon test.

Results

Both excitations revealed 24 lesions. For SE sequences using dual-source mode, image homogeneity was improved (P = 0.00), scan time was reduced, and ghost artifacts on DWI were significantly reduced (P = 0.00). However, image contrast was not increased and lesion conspicuity had no significant difference between two modes, except DWI on which lesion conspicuity was significantly improved (P = 0.00), due to less ghost artifacts. For field-echo sequence, image homogeneity, acquisition time, image contrast and lesion conspicuity had no significant difference between the two modes.

Conclusions

Dual-source parallel RF transmission has some added value for improving breast image quality. However, its value is limited in terms of improving lesion detection and characterization.  相似文献   

18.

Purpose

To develop a method for estimating metabolite concentrations using phased-array coils and sensitivity-encoded (SENSE) magnetic resonance spectroscopic images (MRSI) of the human brain.

Materials and Methods

The method is based on the phantom replacement technique and uses receive coil sensitivity maps and body-coil loading factors to account for receive B1 inhomogeneity and variable coil loading, respectively. Corrections for cerebrospinal fluid content from the MRSI voxel were also applied, and the total protocol scan time was less than 15 min. The method was applied to 10 normal human volunteers using a multislice 2D-MRSI sequence at 3 T, and seven different brain regions were quantified.

Results

N-Acetyl aspartate (NAA) concentrations varied from 9.7 to 14.7 mM, creatine (Cr) varied from 6.6 to 10.6 mM and choline (Cho) varied from 1.6 to 3.0 mM, in good general agreement with prior literature values.

Conclusions

Quantitative SENSE-MRSI of the human brain is routinely possible using an adapted phantom-replacement technique. The method may also be applied to other MRSI techniques, including conventional phase encoding, with phased-array receiver coils, provided that coil sensitivity profiles can be measured.  相似文献   

19.

Purpose

To compare the image quality of three techniques and diagnostic performance in detecting implant rupture.

Materials and Methods

The study included 161 implants for the evaluation of image quality, composed of water-saturated short TI inversion recovery (herein called “water-sat STIR”), three-point Dixon techniques (herein called “Dixon”), and short TI inversion recovery fast spin-echo with iterative decomposition of silicone and water using least-squares approximation (herein called “STIR IDEAL”) and included 41 implants for the evaluation of diagnostic performance in detecting rupture, composed of water-sat STIR and STIR IDEAL.Six image quality categories were evaluated and three classifications were used: normal implant, possible rupture, and definite rupture.

Results

Statistically significant differences were noted for the image quality categories (p < 0.001). STIR IDEAL was superior or equal to water-sat STIR in all image quality categories except artifact effects and superior to Dixon in all categories. Water-sat STIR performed the poorest for water suppression uniformity.The sensitivity and specificity in detecting implant rupture of STIR-IDEAL were 81.8 % and 77.8 % and the difference between two techniques was not statistically significant.

Conclusion

STIR-IDEAL is a useful silicone-specific imaging technique demonstrating more robust water suppression and equivalent diagnostic accuracy for detecting implant rupture, than water-sat STIR, at the cost of longer scan time and an increase in minor motion artifacts.  相似文献   

20.

Objective

The objective of this study was to retrospectively analyze the value of dynamic half-Fourier single-shot turbo spin echo (HASTE) imaging in patients with suspected deep venous thrombosis (DVT).

Materials and Methods

Fifty-five veins in 24 patients were interrogated using a HASTE sequence with the patients relaxed and in various degrees of Valsalva. Veins were analyzed for changes in caliber (+CAL) and signal intensity (+SI) or in their absence (−CAL and −SI, respectively) and compared with the presence of thrombus on gadolinium-enhanced magnetic resonance imaging.

Results

There was no thrombus in veins with the +CAL, +SI pattern (n=40) (P<.01). Five of seven veins (71.4%) with the −CAL, −SI pattern had thrombus (P<.01). A qualitative change in CAL had a sensitivity of 100% and a specificity of 91% for the presence of thrombus. An increase of 1.5 mm in CAL had a sensitivity of 100% and a specificity of 93% for this diagnosis.

Conclusion

Dynamic HASTE imaging offers a physiological method to evaluate veins for deep venous thrombosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号