首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A new substrate, 2-carboxy-1-naphthyl phosphate (CNP), was developed for the fluorimetric determination of alkaline phosphatase (ALP) activity. The product of the enzyme reaction is 1-hydroxy-2-naphthoic acid (HNA), which is a strong fluorescent product. The amount of HNA generated is proportional to ALP activity. Optimal conditions for the determination of ALP were investigated. The linear range and detection limit for the determination of ALP are 0.01-4.8 U/L and 7.44 mU/L, respectively. This method is simple, practical and can be successfully applied to assess ALP in human serum with good accuracy and precision. The results were evaluated by comparison with a standard colorimetric assay using p-nitrophenyl phosphate as ALP substrate.  相似文献   

2.
Enzymes are widely used as labels in immunoassay and especially useful at low concentrations of the analyte in the sample. Most routine detection methods are based on the formation of color or fluorescent products, which are determined by spectropho-tometry or fluorometry, respectively. Electrochemical detection has been applied to the enzyme immunoassay with the potentials of combining the low detection limits and good selectivity of electroanalytical chemistry with the specificity of immun…  相似文献   

3.
Fourier transform infrared spectroscopy is applied to the determination of alkaline phosphatase (ALP) activity in human sera. 4-nitrophenylphosphate was found to be an excellent ALP substrate for FT-IR spectroscopic detection. The developed method is based on the acquisition of two FT-IR spectra: one recorded immediately after mixing the sample and assay solution and the other after an incubation time of 10 min. Spectral changes in the mid IR range due to the enzymatic reaction could be correlated to the ALP activity in the sample. Experimental conditions were established such that the clinically relevant range for determination of ALP activity in human sera (50 to 900 U/L) was covered. The method was applied to the analysis of ALP activities in standard solutions as well as in human sera yielding results which agreed well with those obtained by a standard reference method. Received: 20 June 1997 / Accepted: 16 September 1997  相似文献   

4.
Fourier transform infrared spectroscopy is applied to the determination of alkaline phosphatase (ALP) activity in human sera. 4-nitrophenylphosphate was found to be an excellent ALP substrate for FT-IR spectroscopic detection. The developed method is based on the acquisition of two FT-IR spectra: one recorded immediately after mixing the sample and assay solution and the other after an incubation time of 10 min. Spectral changes in the mid IR range due to the enzymatic reaction could be correlated to the ALP activity in the sample. Experimental conditions were established such that the clinically relevant range for determination of ALP activity in human sera (50 to 900 U/L) was covered. The method was applied to the analysis of ALP activities in standard solutions as well as in human sera yielding results which agreed well with those obtained by a standard reference method.  相似文献   

5.
In this paper, we reported a sensitive electrochemical immunosensor coupling protein A/G@magnetic beads and an ALP-based enzymatic-electrochemical reaction on the inkjet printing microchips for the determination of thyroid stimulating hormone.  相似文献   

6.
A multiwalled carbon nanotube/chitosan modified glassy carbon electrode (MWCNTs‐CHT/GCE) has been used for simultaneous determination of paracetamol (PAR) and uric acid (UA). The measurements were carried out using differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CA). DPV measurements showed a linear relationship between oxidation peak current and concentration of PAR and UA in phosphate buffer (pH 7) over the concentration range 2 µM to 250 µM, and 10 µM to 400 µM, respectively. The analytical performance of this sensor has been evaluated for detection of PAR and UA in human serum and human urine with satisfactory results.  相似文献   

7.
荧光光度法测定血清中碱性磷酸酶   总被引:1,自引:0,他引:1  
合成了一种新的底物水杨酸磷酸酯 (SP),用于荧光光度法测定血清中碱性磷酸酶(ALP)活力.在37.0 ℃的Tris-HCl缓冲液(pH 9.0)条件下, 碱性磷酸酶作用于荧光底物SP,水解生成强荧光产物水杨酸(SA),生成的SA的量与参与反应的ALP 的活力成正比.据此建立了荧光光度法测定血清中碱性磷酸酶活力的新方法.测定碱性磷酸酶的线性范围是0.03~6.00 U/L,检测限为7.04 mU/L.本方法适用于血清中碱性磷酸酶的测定.测定结果与临床上常用的以对硝基苯磷酸酯为底物的分光光度法相比,无显著性差异.  相似文献   

8.
研制了一种基于纳米金固定半抗原的间接竞争电化学免疫传感器,可灵敏检测克伦特罗.在金电极表面组装1,6-己二硫醇单分子膜,通过Au-S共价作用连接纳米金颗粒,通过吸附作用固定克伦特罗牛血清白蛋白偶联物.样品中的待测组分与固定化的克伦特罗偶联物竞争结合单克隆抗体,碱性磷酸酯酶标记的二抗选择性地与电极表面捕获的一抗反应,进而催化底物1-萘酚磷酸酯水解生成1-萘酚,在电极表面氧化产生电信号.在优化的实验条件下,克伦特罗浓度在0.1~1000 μg/L范围内与电流强度线性相关,线性方程为I(A)-8.79× 10-7-2.66× 10-7logC (μg/L),相关系数0.9960,检出限达20 ng/L.同时测定了猪肉及猪肝样品中克伦特罗含量,相对标准偏差平均值为7.0%,加标回收率在89.1%~105.6%之间,与传统的间接竞争酶联免疫吸附法对照,结果无显著性差异.  相似文献   

9.
A new chemically modified electrode is constructed based on iron(III) doped zeolite modified carbon paste electrode (Fe3+Y/ZMCPE). The new sensor could be used for the simultaneous determination of the biologically important compounds dopamine (DA) and tyrosine (Tyr). The measurements are carried out using differential pulse voltammetric (DPV) method. The prepared modified electrode shows voltammetric responses of high sensitivity, selectivity and stability for DA and Tyr under optimal conditions, which makes it a suitable sensor for simultaneous trace detection of DA and Tyr in solution. Application of the DPV method demonstrates that in the Briton Robinson buffer solutions (pH=5) containing 50 µmol/L Tyr, there is a linear relationship between the oxidation peaks and the concentrations of DA over the range of 0.1–200 µmol/L, with a detection limit of 0.05 µmol/L (S/N=3). For Tyr a linear correlation between oxidation peak current and concentration of Tyr over the range of 0.5–200 µmol/L (containing 50 µmol/L DA), with a detection limit of 0.08 µmol/L is obtained. The analytical performances of this sensor are evaluated for the detection of DA and Tyr in human serum and a medicine.  相似文献   

10.
Traces of copper(II) can be determined by adsorptive stripping voltammetry using 2‐carboxy‐2′‐hydroxy‐5′‐sulfoformazyl benzene (Zincon) as complex forming reagent. First in phosphate buffer pH 6.4, copper(II)‐Zincon complex was adsorbed on carbon paste electrode (CPE) with an accumulation potential of 0.6 V. Following this, adsorbed complex was oxidized and detected by differential pulse voltammetric (DPV) scan from 0.6 to 1.0 V. The effective parameters in sensor response were examined. The detection limit (DL) of copper(II) was 1.1 μg/L and relative standard deviations (RSDs) for 10 and 200 μg/L Cu(II) were 1.81 and 1.03%, respectively. The calibration curve was linear for 2–220 μg/L copper(II). The resulting CPE does not use mercury and therefore, has a positive environmental benefit. The method, which is reasonably sensitive and selective, has been successfully applied to the determination of trace amount of copper in water and human hair samples.  相似文献   

11.
采用电聚合方法在石墨烯纳米片(GN)的表面聚合一层聚对氨基苯磺酸(PABSA),制备了聚对氨基苯磺酸/石墨烯复合修饰玻碳电极(PABSA/GN/GCE)。研究了尿酸(UA)和抗坏血酸(AA)在该修饰电极上的电化学行为。与聚对氨基苯磺酸修饰电极(PABSA/GCE)及石墨烯单层膜修饰电极(GN/GCE)相比,复合修饰电极PABSA/GN/GCE显著提高了对UA和AA的检测灵敏度和分离度。在0.1 mol/L磷酸盐缓冲溶液(pH7.0)中,UA和AA的峰电位差达344 mV,表明PABSA/GN/GCE能实现对UA的选择性测定。UA的峰电流与其浓度呈良好的线性关系,线性范围为1.0×10-7~8.0×10-4mol/L,检出限为4.5×10-8mol/L。该复合修饰电极用于尿样中尿酸的测定,结果满意。  相似文献   

12.
采用电化学聚合法制备了聚铬黑T膜修饰电极,应用扫描电镜、交流阻抗法和循环伏安法对修饰电极进行表征,以循环伏安法研究硫酸特布他林在修饰电极上的电化学行为,并以差示脉冲伏安法对其含量进行测定.该方法对硫酸特布他林有明显的电催化作用,在pH 7.0磷酸盐缓冲液中,氧化峰电流与硫酸特布他林浓度在1.2x10-7~2.0x10-6mol•L-1范围内呈良好的线性关系,检测限为1.5x10-8 mol•L-1,回收率在97.9%~104.6%之间,RSD在2.8 % (C=8x10-7mol•L-1,n=11).该方法简便灵敏,结果准确可靠,方法重复性好,可用于硫酸特布他林及其片剂的质量控制.  相似文献   

13.
Sun X  Jin W  Li D  Bai Z 《Electrophoresis》2004,25(12):1860-1866
A novel method for the determination of alkaline phosphatase (ALP) isoenzymes in individual fibroblast cells of mouse bone marrow was developed by combining capillary electrophoresis with an on-capillary enzyme-catalyzed reaction and electrochemical detection. In this method, a single an cell, followed by 5.0 x 10(-2) mol/L Na2B4O7- 3.0 x 10(-2) mol/L NaCl (pH 9.8) as cell lysis solution, was injected into the inlet of the separation capillary by electromigration. The cell was lysed by applying a voltage of 2 kV. The ALP isoenzymes in the cell were preseparated at 20 kV for 1 min, and then allowed to react for 30 min with disodium phenyl phosphate as enzyme substrate in the running buffer. ALP converted disodium phenyl phosphate into its product, phenol, at a relatively high reaction rate without consumption, with resultant amplification of the signal on prolonged reaction time, producing an adequate amount of product for final detection. A mass detection limit as low as 3.5 x 10(-21) mol/L (corresponding to 1.5 nU) was achieved. Finally, the two zones of products generated by ALP isoenzymes were detected at the outlet of the capillary by using the end-capillary amperometric detection at a carbon fiber microdisk bundle electrode with a constant potential.  相似文献   

14.
The present work describes the preparation and characterization of a carbon nanotube paste electrode modified with 2,7-bis(ferrocenyl ethyl)fluoren-9-one (2,7-BF). This electrode showed an efficient catalytic activity for the electro-oxidation of 6-thioguanine (6-TG), which leads to lowering 6-TG overpotential by more than 610 mV. Also, the values of catalytic rate constant (k = 2.7 × 10(3) mol(-1) L s(-1)), and diffusion coefficient (D = 2.7 × 10(-5) cm(2) s) were calculated. In 0.1 M phosphate buffer solution of pH 7.0, the oxidation current increased linearly with two concentration intervals of 6-TG, one is 0.06 to 10.0 μmol L(-1) and the other is 10.0 to 160.0 μmol L(-1). The detection limit (3σ) obtained by differential pulse voltammetry (DPV) was 22.0 nmol L(-1). DPV was used for simultaneous determination of 6-TG, uric acid (UA) and folic acid (FA) at the modified electrode, and for quantification of 6-TG, UA and FA in some real samples by the standard addition method.  相似文献   

15.
《中国化学快报》2021,32(11):3421-3425
In this work, a very simple dual-readout lateral flow test strip (LFTS) platform was developed for sensitive detection of alkaline phosphatase (ALP) based on a portable device. In this assay, quantum dots (QDs) conjugated with bovine serum albumin (QDs-BSA) were chosen as fluorescence signal labels. In the absence of ALP, MnO2 nanosheets aggregate on the test line and exhibit an obvious brown color, which can be observed by naked eyes to realize semi-qualitative analysis. Meanwhile, fluorescence intensity of QDs-BSA can also be effectively quenched by MnO2 nanosheets due to inner-filter effect. Correspondingly, in the presence of ALP, ALP can catalyze the hydrolysis of ascorbic acid 2-phosphate (AAP) to generate L-ascorbic acid (AA), which can reduce MnO2 into Mn2+, accompanying with the obvious fluorescence recovery of the QDs. By simply monitoring the change of colorimetric and fluorescent signal on the test line, trace amount of ALP can be quantitatively detected. Under the optimal conditions, measurable evaluation of ALP was reached in a linear range from 1 U/L to 20 U/L with a detection limit of 0.7 U/L based on fluorescence signal. Furthermore, this colorimetric/fluorescent dual-readout assay was successfully applied to monitor ALP in human serum samples, showing its great potential as a point of care biosensor for clinical diagnosis.  相似文献   

16.
A new chemically modified electrode is constructed based on an iron(III) doped zeolite modified carbon paste electrode (Fe3+Y/ZCME). The electrode was evaluated as a sensor for sub‐micromolar determination of tryptophan (Trp) and dopamine (DA). The measurements were carried out using the differential pulse voltammetry (DPV) method in a phosphate buffer solution with pH = 5. The prepared modified electrode shows voltametric responses with high sensitivity and stability for DA and Trp in optimal conditions. The analytical performance of this sensor has been evaluated for detection of DA and Trp in human serum.  相似文献   

17.
Abstract

A simple HPLC method with minimal sample preparation and good reproducibility for the determination of trazodone in serum is described. Basified serum samples were extracted using ethyl acetate containing diazepam as the internal standard (IS). Chromatography was performed on a cyanopropylsilane column with 15 μL sample injection. The mobile phase consisted of 0.02 M ammonium phosphate, pH 7.5 : acetonitrile (70:30 v/v). The eluent was monitored at 220 nm. The serum standard curve was linear from 10.0 to 8000.0 ng/mL serum. The overall within-run quality control CV was 6.3% for five concentrations (20.0, 40.0, 100.0, 250.0 and 1000.0 ng/mL) and the overall recovery from serum was 85.4%. This method has been applied to the analysis of human serum samples.  相似文献   

18.
《Electroanalysis》2005,17(20):1886-1894
Lamivudine (LAM) is a synthetic nucleoside analogue with activity against human immunodeficiency virus‐type 1 (HIV‐1) and Hepatitis B virus (HBV). The aim of this study was to determine LAM levels in serum and pharmaceutical formulations, by means of electrochemical methods using hanging mercury drop electrode (HMDE). On this electrode, LAM undergoes irreversible reduction at the peak potential near Ep?1.26 V (vs. Ag/AgCl/3 M KCl). Reduction LAM signals were measured by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and square‐wave voltammetry (OSW). DPV and OSW techniques for the determination of LAM in acetate buffer at pH 4.5, which allows quantitation over the 4×10?6 to 1×10?4 M range in supporting electrolyte for both methods, were proposed. The linear response was obtained in acetate buffer in the ranges of 2×10?6 to 2×10?4 M for spiked serum samples at pH 4.5 for both techniques. The repeatability and reproducibility of the methods for all media were determined. The standard addition method was used in serum. Precision and accuracy were also checked in all media. No electroactive interferences from the endogenous substances were found in serum. With respect to side effects of high doses and short half‐life of LAM, a fast and simple detection method is described in this study.  相似文献   

19.
刘雪  王兰  樊阳  刘凤杰 《化学通报》2012,(5):458-462
利用在玻碳电极上修饰了TiO2-石墨烯-Nafion复合膜制得的修饰电极进行多巴胺(DA)和尿酸(UA)的同时测定。用循环伏安法(CV)和差分脉冲伏安法(DPV)研究了该修饰电极的电化学行为。在pH为7.0的磷酸盐缓冲液(PBS)中,修饰电极对于DA和UA的电化学氧化具有良好的电催化性能。DA和UA的氧化峰电流分别在2~120和60~300μmol/L浓度范围内呈良好的线性关系,检出限分别为0.066和0.102μmol/L。实验结果表明,TiO2-石墨烯-Nafion复合膜修饰电极显著提高了检测的灵敏度,并表现出良好的选择性和重现性。  相似文献   

20.
人体内摄入过多的铝可能导致或促进阿尔茨海默氏病 ( Alzheimer s disease)、帕金森氏病( Parkinson s disease)及透析脑病 ( Dialysis encephalopathy)的发病 [1] .原子吸收光谱法、能量分布 X射线光谱法、 X射线微探针分析法、激光微探针质量分析法和核显微法曾用于测定脑铝 .这些方法在样品制作过程中易被污染 [2 ,3] ,仪器昂贵 ,灵敏度不高 ,而且均不能用于人体液和脑铝的在体检测 .由于铝的还原电位约 - 1 .7V,易受 H+干扰 ,直接测定铝有困难 .吸附伏安法利用铝与染料的配合物的电化学响应来测定环境和生物制品中的铝 ,检测下限达 1…  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号