首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary A method for determining aromatic sulfonates in sea water is presented. Ion-pair solid phase extraction is coupled on-line to ion-pair liquid chromatography with UV detection. In the enrichment step, the recoveries from 100 mL of sea water were higher than 65% for most analytes. Linearity was good and detection limits were between 0.02 and 1 μgL−1. The repeatability of the method, expressed as % of relative standard deviation (n=3) was between 1 and 15%. The method was checked in coastal water near the commercial port of Tarragona, where effluents from the petrochemical industry are discharged. All the samples taken were found to contain 2-naphthalenesulfonate.  相似文献   

2.
Summary A reversed-phase high-performance liquid chromatographic method for the determination of chloride in plasma, urine, saliva, sweat and aqueous solution is described. Chloride, in solution in aqueous acetone, is converted by means of pentafluorobenzyl bromide into pentafluorobenzyl chloride. This derivative is separated on a ODS-5 m reversed-phase column using isocratic elution with acctonitrile/water, 50/50, v/v, at a flow rate of 2.0 ml/min, and detected by a UV detector at 264 nm. The method is rapid, accurate and sufficiently sensitive for the determination of chloride in less than 10 l sample volume of a biological fluid.  相似文献   

3.
In this paper, a separation method of the inorganic anions including I, NO 2 , NO 3 , IO 3 and SCN on the reversed-phase ion-pair chromatography with direct UV detection has been developed, and the limits of detection of these inorganic anions were determined. The effects of the organic modifier volume fraction and concentration of the ion-pair reagent on the retention of inorganic anions were discussed.  相似文献   

4.
Summary A new sensitive HPLC-UV method has been developed and validated for the determination of amboroxol in dog plasma enabling the investigation of a newly developed 75 mg ambroxol-containing retard capsule of EGIS Pharmaceuticals Ltd., Budapest, Hungary. A gradient method was used for removing the longer retained plasma components of no interest. The separation was performed on a BDS Hypersil C18 (5 μm, 250×2.1 mm) analytical column, supplied with a 10 mm guard column containing the same packing material. The detection was performed at 210 nm. The calibration curve was linear in the range 25–2000 ng·mL−1. Nerisopam (EGIS-6775) was used as internal standard. Presented at Balaton Symposium on High Performance Separation Methods, Siófok, Hungary, September 1–3, 1999  相似文献   

5.
Feng  Y. Q.  Shibukawa  M.  Oguma  K. 《Chromatographia》1995,41(5-6):532-538
Summary The reversed-phase ion-pair liquid chromatographic behaviour of several metal complexes with 5-sulphoquinoline-8-ol (HQS) on an octadecyl-modified silica column was investigated by using a fluorescence detector. The aluminum complex gave two peaks on the chromatograms when eluents containing phosphate buffer were used. The effects of the pH of the eluent, HQS concentration, the nature of anions in the eluent, and the column temperature on the retention behaviour of the aluminum complex are discussed on the basis of the equilibria and the kinetics of the complexation of the aluminum ion with HQS and anions in the eluent. The equilibrium constant for the interconversion reaction between the two Al(III)-HQS species which correspond to the two peaks observed and the second stepwise formation constant for the Zn(II)-HQS complex were evaluated from the HPLC data obtained.  相似文献   

6.
Summary The retention of positively and negatively charged and neutral solutes was studied in an aqueous phosphate buffer eluent, with constant inorganic-counterion concentration, on ODS-Hypersil stationary phase in the presence of various sulfonic acid ion-pairing reagents. The adsorption isotherms of the ion-pairing reagents d-camphor-10-sulfonic acid, sodium cyclohexylsulfamic acid and sodium alkylsulfonates (butyl-, hexyl- and octyl-) were determined by the breakthrough method.Dedicated to Professor J. F. K. Huber on the occasion of his 60th birthday.  相似文献   

7.
Summary The distribution equilibria of cationic compounds in reversed-phase chromatographic systems (ion-pair chromatography) have been studied on the basis of their effect on a detectable mobile phase component. The solid phase was a polystyrene-divinylbenzene copolymer and the detectable component, a quaternary ammonium ion, 1-methylpyridine. The solutes were mono- and divalent amines and quaternary ammonium ions. The cations can be retained by ion-pair adsorption and ion exchange. Expressions for the ion-pair retention of the solutes and the mobile phase cation (system peak) have been developed assuming Langmuir distribution of ion pairs to a solid phase with one kind of binding site. The validity of the expressions has been tested by evaluation of ion-pair distribution constants using non-linear curve fitting techniques. Good agreement for the constants of common ion pairs was obtained from different kinds of capacity ratio expressions. Ion exchange retention can appear beside ion-pair retention, and it has been observed in the pH range 1.6–6.1. The effect depends not only on cations in the mobile phase, but also on the nature of the buffering systems.  相似文献   

8.
This report describes the determination of paraquat (PQ) in human blood plasma samples by a direct-injection reversed-phase ion-pair chromatographic method. Blood plasma filtrate was injected directly into the LiChrospher® RP-18 alkyl-diol silica (ADS) precolumn integrated in a column switching system using a mixture of 3% 2-propanol and 10 mM sodium octane sulfonate (SOS) in a 0.05 M phosphate buffer (pH 2.8). After washing with this phase, the ADS precolumn was back-flushed with the analytical mobile phase consisting of 40% of methanol and 10 mM SOS in a 0.05 M phosphate buffer (pH 2.8) at a flow rate of 1.0 ml min−1, in order to carry the analyte to a conventional reversed-phase analytical column, where the separation of PQ was achieved and finally detected by UV at 258 nm. The recoveries of PQ from human blood plasma samples ranged between 95.0 and 99.5% at nine different concentrations (from 0.05 to 3.00 μg of PQ ml−1) with coefficients of variation <2.5% (n=3). The precision expressed as relative standard deviation was below 3.5% for between-day and below 4.3% for within-day measurements (n=5). The detection limit (signal-to-noise ratio, S/N>3) was 0.005 μg ml−1 with an injection volume of 200 μl. The proposed method is promising for the identification and quantification of PQ at low concentration levels and is suitable for its analysis in human blood plasma samples from intentional or accidental poisonings cases with a sample throughput of 5 samples per hour.  相似文献   

9.
In the present work, an analytical method for determination of risedronate, a member of bisphosphonates, is described for the routine analysis in rat plasma. Sample pre-treatment involves protein precipitation, co-precipitation with calcium at alkaline pH, hydrolysis of possible derivatives of pyrophosphate and reprecipitation. A good separation was obtained by using a reversed-phase column (Hypersil ODS-2 C18, 4.6 mm × 250 mm, 5 μm). The mobile phase was an aqueous solution of buffer (contained 1.5 mM EDTA-2Na, 1 mM sodium etidronate, 11 mM sodium phosphate and 5 mM tetrabutylammonium bromide as ion-pair reagent) - methanol (88:12, v/v) adjusted to pH 6.75 using 1 M NaOH. The flow rate was 1 ml min−1. UV detection (λ = 262 nm) was used to quantitate risedronate in the concentration range of 10-500 ng ml−1. The limit of detection and quantitation for risedronate were 7 and 10 ng ml−1, respectively. The method was applied successfully to plasma samples from Wistar rats undergoing oral administration of risedronate mini-pills. Precision, extraction recoveries, as well as accuracy results, were satisfactory and no interference was found at the retention time of risedronate. Hence, the method is suitable for monitoring risedronate in rat plasma.  相似文献   

10.
A. Mandl  W. Lindner 《Chromatographia》1996,43(5-6):327-330
Summary An improved, reversed-phase, high-performance liquid chromatography (HPLC) method with dual UV-fluorescence detection for simultaneous determination of the antifolate methotrexate, the folate leucovorin and their two main metabolites 7-hydroxymethotrexate and 5-methyltetrahydrofolate, respectively is presented. The fluorescence intensity of leucovorin could be significantly increased by on-line, post-column irradiation with UV at 254 nm thus lowering the limit of detection for leucovorin to 0.2 ng absolute at a signal-to-noise ratio 31.  相似文献   

11.
Summary The behaviour of various octadecyl commercial bonded phases are compared in classical reversed-phase chromatography and in ion-pair reversed-phase chromatography. Great differences are exhibited by the packings studied according to the polarity of the solutes. Whereas hydrocarbonaceous bonded phases show very similar selectivity versus apolar or weakly polar solutes, great differences are observed when analyzing more polar solutes even when ion-pair reversed-phase chromatography is performed.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

12.
Summary A reversed-phase ionpair chromatographic method with tetramethylene oxide as organic modifier has been developed for the simultaneous separation and detection of the sulfides NH2CSNH2, (NH4)2CS3, (NH4)2S, and NH4SCN. The optimized separation conditions were determined by means of a U7 (76) uniform design experiment, and tetramethylene oxide played an important role in adjusting the retention behavior of (NH4)2S and NH4SCN. The linearity of the calibration plots for the four components was investigated; correlation coefficients were from 0.9989–0.9999. The proposed method was successfully applied to the determination of NH2CSNH2, (NH4)2CS3, (NH4)2S, and NH4SCN in synthesis and isomerization samples.  相似文献   

13.
Fast analysis of thiocyanate by ion-pair chromatography using a silica-based monolithic column and direct conductivity detection was carried out. Chromatographic separation was performed on a Chromolith Speed ROD RP-18e using tetrabutylammonium hydroxide (TBA)-phthalic acid-acetonitrile as eluent. The effects of eluent concentration, eluent pH value, column temperature and flow rate on retention time of thiocyanate were investigated. The optimized chromatographic conditions for the determination of thiocyanate were as follows: 0.25 mmol/L TBA-0.18 mmol/L phthalate-7% acetonitrile (pH 5.5) as eluent, column temperature of 30 ℃, and flow rate of 6.0 mL/min. Retention time of thiocyanate was less than 1 min under the conditions. Common anions (Cl^-, NO3 , SO42 and I^- ) did not interfere with the determination of thiocyanate. Detection limit (S/N = 3) of thiocyanate was 0.96 mg/L. Calibration graph between peak area and the concentration of thiocyanate was linear in the range of 2.0- 100.0 mg/L. Relative standard deviation (RSD) of chromatographic peak area was 1.4% (n = 5). This method has been applied to the determination of thiocyanate in ionic liquids. Recoveries of thiocyanate after spiking were 100.5%.  相似文献   

14.
Summary A recently-developed octadecyl-bonded alumina (ODA) stationary phase was evaluated for the separation of peptides and proteins by reversed phase high performance liquid chromatography. Using standard water-acetonitrile mobile phase gradients containing 0.1 % trifluoroacetic acid, the average peak capacity obtained for the separation of a mixture of ribonuclease a, cytochrome c, lysozyme and carbonic anhydrase on an ODA column are similar to that obtained on a widely used octadecylsilane (ODS) column. However, overall chromatographic resolution of the components of this mixture on ODA is inferior to that obtained on ODS. Cytochrome c peak areas were found to be 50% smaller on the ODA column than on ODS. On the other hand, both peak capacities and resolutions of octapeptide mixtures were found to be generally superior on the ODA column, and peak areas for a representative octapeptide were found to be virtually identical for both ODA and ODS columns. The differences in the results obtained on the ODA and ODS columns for these separations are attributed to the smaller pore size and unique fused-microplatelet shape of the ODA particles. Comparisons of the separations of the tryptic digest of cytochrome c on the ODS and ODA columns demonstrate that the ODA phase is potentially as useful as ODS for peptide mapping applications.  相似文献   

15.
A. Werner 《Chromatographia》1991,31(7-8):401-410
Summary HPLC methods for the separation of nucleotides, nucleosides and nucleobases by ion-pair reversed-phase are reviewed. The advantages of these are discussed versus anion-exchange and reversed phase separations. Extraction procedures for nucleotide determinations from cells and tissues are pointed out in detail. Extracts from red blood cells, Ehrlich ascites tumour cells, hepatocytes, intestine are used for determination of nucleotide concentrations by the methods described.  相似文献   

16.
An ion-pair reversed phase liquid chromatography method for the antituberculosis drug ethambutol hydrochloride was developed using sodium 1-heptanesulfonate (4.0 mg/ml) as an ion-pairing (IP) reagent. To enable detection of the ethambutol with a UV detector without sample pretreatment, the pH 4.5 aqueous tetrahydrofuran (THF) (25%, v/v) mobile phase contained 1.0 mM Cu(II), which forms a UV-absorbing complex with the analyte. At a column temperature of 35 °C, ethambutol gives a symmetrical peak with a retention time of 5 min. Chromatographic conditions were optimized through study of the effects of mobile phase composition and pH, Cu(II) and IP reagent concentration, and column temperature. The method is shown to be simple, precise, efficient, robust, linear up to at least 0.25 mg/ml, and to have a limit of quantitation of 6 μg/ml.  相似文献   

17.
Summary This paper describes the development of a chromatographic system for analysis of commercial ceramides structurally similar to those found in the stratum corneum. The ceramides used in this study contain different amine based (phytosphingosine, sphingosine and dihydrosphingosine) and fatty acids of different chain lengths and with different functional groups (hydroxylated and unsaturated). Non-aqueous reversed-phase (NARP) liquid chromatography with evaporative light-scattering detection (ELSD) were the techniques chosen in accordance with the nature of the ceramides. The eluent strength and the potential selectivity of different organic solvents were investigated. On a C18-bonded silica, the most promising chromatographic conditions employed a gradient from ACN-THF, 95∶5, to ACN-THF-PrOH, 35∶5∶60, in 15 min with a constant concentration of TEA (10 mM) and a stoichiometric amount of formic acid.  相似文献   

18.
Summary Gradient elution of polystyrene standards on reversed phase C18 columns by methanol/tetrahydrofuran or methanol/dichloromethane mixtures yielded a strange effect of the molecular weight of the sample on the specific peak are (mAUs per g sample injected). The effect did not occur when pure dichloromethane was used as an eluent. Further to this, dependence of specific peak area on flow rate was observed in gradient elution with methanol/tetrahydrofuran mixtures. It was found that these effects were due to polymer elution at the verge of precipitation. Depending on the dwell time of the sample in the column, opalescence occurred that added to the UV signal used for monitoring the elution.  相似文献   

19.
Summary In the determination of ephedrine using reversed-phase, ion-pair liquid chromatography, a chromatographically pure sample was observed to give three peaks under certain mobile phase conditions. The mobile phases which produced maximum peak splitting were determined for ephedrine and a number of other sympathomimetic drugs.A proposal that peak splitting was the result of the composite interplay of two discrete chromatographic mechanisms, was investigated. The results of analysis by GC/MS confirmed that each peak was due to ephedrine, however, only one of the three split peaks was found to contain ion pairs. It is postulated that peak splitting is a physical phenomenon on reversed-phase columns and the separation of these drugs by ion-pair HPLC is based on a mixed rather than a single mechanism.This study has also shown that errors can arise in ion-pair HPLC when multiple peaks are assumed to indicate heterogeneity. Interconvertible species of the same solute can give rise to these peaks.  相似文献   

20.
Summary A gradient elution ion-pair HPLC assay was developed for the analysis of tylosin and related macrolides in fermentation broth. The effect of the ion-pair agent concentration and identity was studied to optimize the reproducibility of the separation. The assay compares favorably with the biological assay and is sufficiently durable for the analysis of many samples per column.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏