首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We introduce a novel dry wafer bonding concept designed for permanent attachment of micromolded polymer structures to surface functionalized silicon substrates. The method, designed for simultaneous fabrication of many lab-on-chip devices, utilizes a chemically reactive polymer microfluidic structure, which rapidly bonds to a functionalized substrate via"click" chemistry reactions. The microfluidic structure consists of an off-stoichiometry thiol-ene (OSTE) polymer with a very high density of surface bound thiol groups and the substrate is a silicon wafer that has been functionalized with common bio-linker molecules. We demonstrate here void free, and low temperature (< 37 °C) bonding of a batch of OSTE microfluidic layers to a silane functionalized silicon wafer.  相似文献   

2.
We report a reliable strategy to perform automated image cytometry of single (non-adherent) stem cells captured in microfluidic traps. The method rapidly segments images of an entire microfluidic chip based on the detection of horizontal edges of microfluidic channels, from where the position of the trapped cells can be derived and the trapped cells identified with very high precision (>97%). We used this method to successfully quantify the efficiency and spatial distribution of single-cell loading of a microfluidic chip comprised of 2048 single-cell traps. Furthermore, cytometric analysis of trapped primary hematopoietic stem cells (HSC) faithfully recapitulated the distribution of cells in the G1 and S/G2-M phase of the cell cycle that was measured by flow cytometry. This approach should be applicable to automatically track single live cells in a wealth of microfluidic systems.  相似文献   

3.
We developed a novel microfluidic cell culture device in which magnetic beads repetitively collide with osteoblast cells, MC3T3‐E1, owing to attractive forces generated by pulsed electromagnetic fields and consequently the cells were physically stimulated by bead impacts. Our device consists of an on‐chip microelectromagnet and a microfluidic channel which were fabricated by a microelectromechanical system technique. The impact forces and stresses acting on a cell were numerically analyzed and experimentally generated with different sizes of bead (4.5, 7.6 and 8.4 μm) and at various pulse frequencies (60 Hz, 1 kHz and 1 MHz). Cells were synchronized at each specific phase of the cell cycle before stimulation in order to determine the most susceptible phase against bead impacts. The cells were stimulated with different sizes of bead at various pulse frequencies for 1 min at G1, S and G2 phases, respectively, and then counted immediately after one doubling time. The growth rate of cells was highly accelerated when they were stimulated with 4.5 μm beads at G1 phase and a pulse frequency of 1 MHz. Almost all of the cells were viable after stimulation, indicating that our cell stimulator did not cause any cellular damage and is suitable for use in new physical stimulus modalities.  相似文献   

4.
The gene expression of human embryonic stem cells (hESC) is a critical aspect for understanding the normal and pathological development of human cells and tissues. Current bulk gene expression assays rely on RNA extracted from cell and tissue samples with various degree of cellular heterogeneity. These 'cell population averaging' data are difficult to interpret, especially for the purpose of understanding the regulatory relationship of genes in the earliest phases of development and differentiation of individual cells. Here, we report a microfluidic approach that can extract total mRNA from individual single-cells and synthesize cDNA on the same device with high mRNA-to-cDNA efficiency. This feature makes large-scale single-cell gene expression profiling possible. Using this microfluidic device, we measured the absolute numbers of mRNA molecules of three genes (B2M, Nodal and Fzd4) in a single hESC. Our results indicate that gene expression data measured from cDNA of a cell population is not a good representation of the expression levels in individual single cells. Within the G0/G1 phase pluripotent hESC population, some individual cells did not express all of the 3 interrogated genes in detectable levels. Consequently, the relative expression levels, which are broadly used in gene expression studies, are very different between measurements from population cDNA and single-cell cDNA. The results underscore the importance of discrete single-cell analysis, and the advantages of a microfluidic approach in stem cell gene expression studies.  相似文献   

5.
Cell cycle synchronization is an important tool for the study of the cell division stages and signalling. It provides homogeneous cell cultures that are of importance to develop and improve processes such as protein synthesis and drug screening. The main approach today is the use of metabolic agents that block the cell cycle at a particular phase and accumulate cells at this phase, disturbing the cell physiology. We provide here a non-invasive and label-free continuous cell sorting technique to analyze and synchronize yeast cell division. By balancing opposing dielectrophoretic forces at multiple frequencies, we maximize sensitivity to the characteristic shape and internal structure changes occurring during the yeast cell cycle, allowing us to synchronize the culture in late anaphase.  相似文献   

6.
Liu YJ  Guo SS  Zhang ZL  Huang WH  Baigl D  Xie M  Chen Y  Pang DW 《Electrophoresis》2007,28(24):4713-4722
An integrated smart microfluidic device consisting of nickel micropillars, microvalves, and microchannels was developed for specific capture and sorting of cells. A regular hexagonal array of nickel micropillars was integrated on the bottom of a microchannel by standard photolithography, which can generate strong induced magnetic field gradients under an external magnetic field to efficiently trap superparamagnetic beads (SPMBs) in a flowing stream, forming a bed with sufficient magnetic beads as a capture zone. Fluids could be manipulated by programmed controlling the integrated air-pressure-actuated microvalves, based on which in situ bio-functionalization of SPMBs trapped in the capture zone was realized by covalent attachment of specific proteins directly to their surface on the integrated microfluidic device. In this case, only small volumes of protein solutions (62.5 nL in the capture zone; 375 nL in total volume needed to fill the device from inlet A to the intersection of outlet channels F and G) can meet the need for protein! The newly designed microfluidic device reduced greatly chemical and biological reagent consumption and simplified drastically tedious manual handling. Based on the specific interaction between wheat germ agglutinin (WGA) and N-acetylglucosamine on the cell membrane, A549 cancer cells were effectively captured and sorted on the microfluidic device. Capture efficiency ranged from 62 to 74%. The integrated microfluidic device provides a reliable technique for cell sorting.  相似文献   

7.
Lee WC  Bhagat AA  Huang S  Van Vliet KJ  Han J  Lim CT 《Lab on a chip》2011,11(7):1359-1367
Efficient synchronization and selection of cells at different stages of the cell replication cycle facilitates both fundamental research and development of cell cycle-targeted therapies. Current chemical-based synchronization methods are unfavorable as these can disrupt cell physiology and metabolism. Microfluidic systems developed for physical cell separation offer a potential alternative over conventional cell synchronization approaches. Here we introduce a spiral microfluidic device for cell cycle synchronization, using the combined effects of inertial forces and Dean drag force. By exploiting the relationship between cell diameter and cell cycle (DNA content/ploidy), we have successfully fractionated several asynchronous mammalian cell lines, as well as primary cells comprising bone marrow-derived human mesenchymal stem cells (hMSCs), into enriched subpopulations of G0/G1 (>85%), S, and G2/M phases. This level of cell cycle enrichment is comparable to existing microfluidic systems, but the throughput (~ 15 × 10(6) cells per h) and viability (~ 95%) of cells thus synchronized are significantly greater. Further, this platform provides rapid collection of synchronized cells or of diameter-sorted cells post-separation, to enable diverse applications in the study and manipulation of cell proliferation.  相似文献   

8.
In this study, we prepared a novel rubbed fluorinated polyimide film using a rubbing machine with a rubbing cloth and determined the surface properties of the rubbed film using an atomic force microscope and contact angle measurements. In addition, we evaluated the cell adhesion behavior on the rubbed polyimide film using a phase contrast microscope. Interestingly, a rubbed polyimide surface having a micrometer‐scale grooved pattern was prepared by the rubbing method, and the morphologies of rat primary hepatocytes and human liver cell lines attached to the rubbed surface were three‐dimensional multicellular spheroids, while the cells on an unrubbed surface showed two‐dimensional monolayers. This initial study indicates that the rubbing method without any chemical modification is simple and can easily produce large surface areas, suggesting that the rubbing may become a novel cell culture method. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
Simian virus 40 (SV40) is capable of inducing cellular DNA synthesis in permissive and nonpermissive cells. Utilizing flow cytometry, we analyzed the DNA content changes in two diploid human cell strains and two monkey cell lines. The osteogenesis imperfecta (OI) human skin fibroblasts were induced into DNA synthesis, and within one to two cell generations, a polyploid cell population was produced. With WI-38 phase II cells, a similar pattern of increased cycling of cells into DNA synthesis was observed; however, the majority (approximately 60%) of the cells were blocked in the G2 + M phase of the cell cycle. At later time intervals, an increase in the G1 population was demonstrated. The two monkey cell lines responded to SV40 virus with an accumulation of cells in the G2 + M phase of the cell cycle. Thus, two diploid human cell strains exhibited different cell cycle kinetics early after infection with SV40 virus. The one strain (WI-38) behaved similarly to the two monkey cell lines studied. The other strain (OI) responded similarly to nonpermissive (transforming) cells infected with SV40 virus.  相似文献   

10.
We have developed a general method combining photochemical grafting and copper-catalyzed click chemistry for biofunctionalization of titanium substrates. The UV-activated grafting of an α,ω-alkenyne onto TiO(2)/Ti substrates provided a "clickable" thin film platform. The selective attachment of the vinyl end of the molecule to the surface was achieved by masking the alkynyl end with a trimethylgermanyl (TMG) protecting group. Subsequently, various oligo(ethylene glycol) (OEG) derivatives terminated with an azido group were attached to the TMG-alkynyl modified titanium surface via a one-pot deprotection/click reaction. The films were characterized by X-ray photoelectron spectroscopy (XPS), contact angle goniometry, ellipsometry, and atomic force microscopy (AFM). We showed that the titanium surface presenting click-immobilized OEG substantially suppressed the nonspecific attachment of protein and cells as compared to the unmodified titanium substrate. Furthermore, glycine-arginine-glycine-aspartate (GRGD), a cell adhesion peptide, was coimmobilized with OEG on the platform. We demonstrated that the resultant GRGD-presenting thin film on Ti substrates can promote the specific adhesion and spreading of AsPC-1 cells.  相似文献   

11.
To understand molecular networking at the cellular level, analyses of processes and effects at the single-cell level are most appropriate. Usual biochemical or molecular biological analyses are based on integrated signals of numerous cells which differ, however, in their expression and activity profiles. Here we show that it is possible to determine different types of properties of individual cells by means of a specifically designed microfluidic device. As part of investigations to characterize the human urothelial cell line 5637 as a potential model system for studies of toxic and carcinogenic effects on urothelial cells, we use this cell line to assign cytochrome P450 activity, and expression of the enzymes involved, to individual cells. It is shown that the cell population is very heterogeneous with respect to the extent and kinetics of CYP1A1-dependent ethoxyresorufin O-deethylase (EROD). This is also true for the cells’ CYP1A1 protein content. With some exceptions, the EROD activity largely coincides with the presence of CYP1A1 protein in the cells. The results obtained with the microfluidic device are promising and open up new perspectives with regard to multi-property determinations in individual cells and to studies focusing on the biochemical and molecular heterogeneity of cells. Figure Formation of fluorescent resorufin from ethoxyresorufin by cytochrome P450 activity in urothelial cells attached within the chamber of a microfluidic device  相似文献   

12.
Cell-based microfluidic devices have attracted interest for a wide range of applications. While optical cell counting and flow cytometry-type devices have been reported extensively, sensitive and efficient non-optical methods to detect and quantify cells attached over large surface areas within microdevices are generally lacking. We describe an electrical method for counting cells based on the measurement of changes in conductivity of the surrounding medium due to ions released from surface-immobilized cells within a microfluidic channel. Immobilized cells are lysed using a low conductivity, hypotonic media and the resulting change in impedance is measured using surface patterned electrodes to detect and quantify the number of cells. We found that the bulk solution conductance increases linearly with the number of isolated cells contributing to solution ion concentration. The method of cell lysate impedance spectroscopy is sensitive enough to detect 20 cells microL(-1), and offers a simple and efficient method for detecting and enumerating cells within microfluidic devices for many applications including measurement of CD4 cell counts in HIV patients in resource-limited settings. To our knowledge, this is the most sensitive approach using non-optical setups to enumerate immobilized cells. The microfluidic device, capable of isolating specific cell types from a complex bio-fluidic and quantifying cell number, can serve as a single use cartridge for a hand-held instrument to provide simple, fast and affordable cell counting in point-of-care settings.  相似文献   

13.
Attachment of bacterial cells to carbon electrodes   总被引:1,自引:0,他引:1  
Anodic stripping method was applied to analyze the process of bacterial attachment to the surface of carbon-paste electrodes (CPE). The electrode was immersed for various times in a bacterial cell suspension to allow the cells to attach to its surface. The number of bacterial cells attached to the electrode surface increased along with time. On the other hand, the current derived from the oxidation of a dye, Hoechst, which was adsorbed to the surface after attaching the bacterial cells, decreased along with time. It was considered that the current output, correlated with the amount of dye, adsorbed onto regions where no bacterial cell attached. These results indicate that the bacterial-attachment process can be analyzed by measuring the electric current derived from the dye instead of counting the number of attached cells.  相似文献   

14.
UV/ozone oxidation was combined with a photomasking technique to produce adjacent regions of different chemistry on polystyrene (PS) surfaces. The surface chemistry and topography were studied using AFM, XPS and contact angle measurements. The physicochemical patterns were visualised by the condensation of water vapour upon the surfaces and by the differential attachment of Chinese hamster ovarian (CHO) cells. The orientation of CHO cells on 55 and 125 microm wide oxidised PS strips were measured and found to be highly dependent on the width of the oxidised feature. CHO cells in relatively close proximity to a linear polar/non-polar border showed significant axial alignment along the border. CHO cells can also be confined to specific regions of the polymer surface. Cells attached to larger areas (75 microm x 75 microm) were found to have a smaller average cell size than cells attached to the smaller (56 microm x 56 microm) areas.  相似文献   

15.
A novel tetranuclear copper complex (TCC) has been successfully synthesized and characterized using high resolution mass spectrometry (HRMS), Fourier transform infrared spectroscopy (FTIR) and X-ray single crystal diffraction technique. TCC was capable of triggering by Glutathione (GSH) to produce Cu (Ⅰ), then the resulted Cu (Ⅰ) further converted the overexpression of endogenous H2O2 into •OH, a highly cytotoxic reactive oxygen species (ROS), thereby killing the cancer cells. TCC showed high cytotoxicity to 4T1, MCF7, HepG2 cancer cells. Interestingly, the cytotoxicity of TCC to non-cancerous cells is much lower than that of cancer cells. Cell cycle experiments demonstrated that TCC was capable of arresting the cancer cell cycle in the G2/M phase. The apoptosis experiments shown that TCC could induce apoptosis rather than necrosis.  相似文献   

16.
Finding the few : Cell‐surface proteins are useful disease biomarkers, but current high‐throughput methods are limited to detecting cells expressing more than several hundred proteins. Enzymatic amplification in microfluidic droplets (see picture) is a high‐throughput method for detection and analysis of cell‐surface biomarkers expressed at very low levels on individual human cells. Droplet optical labels allow concurrent analysis of several samples.

  相似文献   


17.
This paper presents a novel optically addressed microactuator array (microfluidic "flash memory") with latched operation. Analogous to the address-data bus mediated memory address protocol in electronics, the microactuator array consists of individual phase-change based actuators addressed by localized heating through focused light patterns (address bus), which can be provided by a modified projector or high power laser pointer. A common pressure manifold (data bus) for the entire array is used to generate large deflections of the phase change actuators in the molten phase. The use of phase change material as the working media enables latched operation of the actuator array. After the initial light "writing" during which the phase is temporarily changed to molten, the actuated status is self-maintained by the solid phase of the actuator without power and pressure inputs. The microfluidic flash memory can be re-configured by a new light illumination pattern and common pressure signal. The proposed approach can achieve actuation of arbitrary units in a large-scale array without the need for complex external equipment such as solenoid valves and electrical modules, which leads to significantly simplified system implementation and compact system size. The proposed work therefore provides a flexible, energy-efficient, and low cost multiplexing solution for microfluidic applications based on physical displacements. As an example, the use of the latched microactuator array as "normally closed" or "normally open" microvalves is demonstrated. The phase-change wax is fully encapsulated and thus immune from contamination issues in fluidic environments.  相似文献   

18.
DA Vickers  EJ Chory  SK Murthy 《Lab on a chip》2012,12(18):3399-3407
To isolate clinically and biologically relevant cell types from a heterogeneous population, fluorescent or magnetic tagging together with knowledge of surface biomarker profiles represents the state of the art. To date, it remains exceedingly difficult to separate phenotypically and physically similar cell types from a mixed population. We report a microfluidic platform engineered to separate two highly similar cell types using a single antibody by taking advantage of subtle variations in surface receptor density and cell size. This platform utilizes antibody-conjugated surfaces in microfluidic channels together with precise modulation of fluid shear stresses to accomplish selective fractionation in a continuous flow process. Antibody conjugation density variation on the adhesive surfaces is achieved by covalently immobilizing an antibody in the presence of poly(ethylene glycol). This platform is used to demonstrate separation of two CD31 positive cell types, human umbilical vein endothelial cells and human micro vascular endothelial cells.  相似文献   

19.
This paper describes a simple plasma-based dry etching method that enables patterned cell culture inside microfluidic devices by allowing patterning, fluidic bonding and sterilization steps to be carried out in a single step. This plasma-based dry etching method was used to pattern cell-adhesive and non-adhesive areas on the glass and polystyrene substrates. The patterned substrate was used for selective attachment and growth of human umbilical vein endothelial cells, MDA-MB-231 human breast cancer cells, NIH 3T3 mouse fibroblasts, and primary rat cortical neurons. Finally, we have successfully combined the dry-patterned substrate with a microfluidic device. Patterned primary rat neurons were maintained for up to 6 days inside the microfluidic devices and the neurons' somas and processes were confined to the cell-adhesive region. The method developed in this work offers a convenient way of micropatterning biomaterials for selective attachment of cells on the substrates, and enables culturing of patterned cells inside microfluidic devices for a number of biological research applications where cells need to be exposed to well-controlled fluidic microenvironment.  相似文献   

20.
Daw  R.  O'Leary  T.  Kelly  J.  Short  R. D.  Cambray-Deakin  M.  Devlin  A. J.  Brook  I. M.  Scutt  A.  Kothari  S. 《Plasmas and Polymers》1999,4(2-3):113-132
The plasma copolymerization of acrylic acid and methyl vinyl ketone with 1,7-octadiene is reported. A range of surfaces including hydrocarbon plasma polymer, carbonyl-containing plasma copolymer and carboxyl-containing plasma copolymers have been prepared and characterized by means of X-ray photoelectron spectroscopy. The stability of these surfaces in water has been assessed at 37°C. The influence of their functional group chemistries on the attachment and spreading of osteoblast-like (ROS 17/2.8) and bone marrow stromal cells (BMSC) has been explored. The data reported show a strong correlation between the carboxyl group and the attachment and spreading of both ROS cells and BMSC. This relationship has been explored in some detail with the ROS cells. Actin-staining by direct immunofluorescence was used to visualize changes in cytoskeleton of ROS cells with substratum chemistry. As the concentration of the carboxyl groups increased cell number and cell spreading were notably enhanced. As few as 5 carboxyls per 100 carbons were sufficient to support good attachment and with cells showing well-defined polygonal cell morphology. Although cells attached to a hydrocarbon plasma polymer surface these cells had failed to spread. The attachment and spreading of BMSC were compared on a carboxyl-containing surface and on a hydrocarbon surface. There was a more marked difference in the number of cells that had attached to these two surfaces (cf. ROS cells). The spreading on the carboxyl surface was much more typical of BMSC. Results from an extended culture using primary cultures of bone marrow cells (BMC) are reported. These cells were not trypsinized and appear to be less sensitive to differences in surface chemistry (cf. BMSC). Even so, the results at 10 days indicate much greater biosynthetic activity on the carboxyl-containing surface.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号