1.
We have developed a method for the determination of trace levels of total selenium in water samples. It integrates preconcentration, in-situ photoreduction and slurry photochemical vapor generation using TiO2 nanoparticles, and the determination of total selenium by AFS. The Se(IV) and Se(VI) species were adsorbed on a slurry of TiO2 nanoparticles which then were exposed to UV irradiation in the presence of formic acid to form volatile selenium species. The detection limits were improved 17-fold compared to hydride generation and 56-fold compared to photochemical vapor generation, both without any preconcentration. No significant difference was found in the limits of detection (LODs) for Se(IV) and Se(VI). The LOD is as low as 0.8 ng L?1, the precision is better than 4.5 % (at a level of 0.1 μg L?1 of selenium). The method gave good recoveries when applied to the determination of total selenium in a certified tissue reference material (DORM-3) and in spiked drinking water and wastewater samples containing high concentrations of transition and noble metal ions. It also excels by very low LODs, a significant enhancement of sample throughput, reduced reagent consumption and sample loss, and minimal interference by transition and noble metal ions.
Figure
A method integrating pre-concentration, in situ photo-reduction and slurry photochemical vapor generation by using TiO2 nanoparticles was developed for sensitive determination of total selenium in various water samples by atomic fluorescence spectrometry.  相似文献   

2.
The aim of this study was to evaluate the biological and chemical response of Allium cepa L. exposed to inorganic selenium compounds. Besides the investigation of the total content of selenium as well as its chemical speciation, the Allium test was used to evaluate the growth of onion roots and mitotic activity in the roots’ meristem. The total content of selenium was determined by inductively coupled plasma mass spectrometry (ICP MS). High-performance liquid chromatography (HPLC), coupled to ICP MS, was used for the selenium chemical speciation. Results indicated that A. cepa plants are able to biotransform inorganic selenium compounds into their organic derivatives, e.g., Se-methylselenocysteine from the Se(IV) inorganic precursor. Although the differences in the biotransformation of selenium are due mainly to the oxidation state of selenium, the experiment has also shown a fine effect of counter ions (H+, Na+, NH4 +) on the response of plants and on the specific metabolism of selenium.
Figure
?  相似文献   

3.
A method is presented for matrix separation, preconcentration and determination by hydride generation atomic fluorescence spectrometry of trace amounts of Se(IV). It is based on solidified floating drops of 1-undecanol that are capable of extracting the target analyte after chelation with a water soluble ligand and subsequent ultrasound-assisted back-extraction into a aqueous solution. Hydride generation was then accomplished by reaction with a solution of sodium borohydride. Under optimized conditions, an enrichment factor of 15 and a linear calibration plot in the range from 0.01 to 5.0 μg L?1 were achieved using a 10.0 mL sample. The detection limit (3σ) is 7.0 ng L?1, and the relative standard deviation (RSD) is 2.1% at 1.0 μg L?1 (n?=?11). The method was applied to determination of Se(IV) in different real water samples through recovery experiments and subsequently validated against two certified reference materials.
A solidified floating organic drop microextraction coupled with hydride generation atomic fluorescence spectrometry for the determination of Se(IV) is described.  相似文献   

4.
We report on a glassy carbon electrode (GCE) modified with a lead ionophore and multiwalled carbon nanotubes. It can be applied to square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at ?1.0?V (vs. SCE) for 300?s in pH?4.5 acetate buffer containing 400?μg?L?1 of Bi(III). The ionophore-MWCNTs film on the GCE possesses strong and highly selective affinity for Pb(II) as confirmed by quartz crystal microbalance experiments. Under the optimum conditions, a linear response was observed for Pb(II) ion in the range from 0.3 to 50?μg?L?1. The limit of detection (at S/N?=?3) is 0.1?μg?L?1. The method was applied to the determination of Pb(II) in water samples with acceptable recovery.
Figure
A glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes is successfully applied to sensitive and selective square wave anodic stripping voltammetric determination of Pb(II) ion after preconcentration of Pb(II) at ?1.0?V (vs. SCE) in pH?4.5 solutions containing 400?μg?L?1 of Bi(III).  相似文献   

5.
We report on a novel non-enzymatic sensor for hydrogen peroxide (HP) that is based on a biocomposite made up from chitosan (CS), hemoglobin (Hb), and silver nanoparticles (AgNPs). The AgNPs were prepared in the presence of CS and glucose in an ultrasonic bath, and CS is found to act as a stabilizing agent. They were then combined with Hb and CS to construct a carbon paste biosensor. The resulting electrode gave a well-defined redox couple for Hb, with a formal potential of about ?0.17?V (vs. SCE) at pH?6.86 and exhibited a remarkable electrocatalytic activity for the reduction of HP. The sensor was used to detect HP by flow injection analysis, and a linear response is obtained in the 0.08 to 250?μM concentration range. The detection limit is 0.05?μM (at S/N?=?3). These characteristics, along with its long-term stability make the sensor highly promising for the amperometric determination of HP.
Figure
(A) FIA it graphs of the different concentrations of H2O2 at CS/Hb/AgNP/CPE in the PBS (pH?6.86). Applied potential: ?0.4?V. (1) 0.8?×?10?6?mol?L?1, (2) 2.4?×?10?6?mol?L?1, (3) 4?×?10?6?mol?L?1 (B) Plot of catalytic peak currents vs. the concentration of H2O2.  相似文献   

6.
We present a study on the application of magnetic nanoparticles (MNPs) prepared from Fe3O4 and functionalized with pyridine as an adsorbent for the solid-phase extraction of trace quantities of Pd(II) ion. The pyridine group was immobilized on the surface of the MNPs by covalent bonding of isonicotinamide. The modified MNPs can be readily separated from an aqueous solution by applying an external magnetic field. Effects of pH, the amount of functionalized MNPs, extraction time, type and quantity of eluent, desorption time, break-through volume and interfering ions on the extraction efficiency were optimized. The amount of Pd(II) was then determined using FAAS. Under the optimized conditions, the detection limit and preconcentration factor are 0.15?μg?L-1 and 196, respectively, and the relative standard deviation (at 20?μgL?1; for n?=?10) is 3.7?%. The method had a linear analytical range from 1 to 80?μg?L-1 and was applied to determine Pd(II) in spiked tape water and soil.
Figure
?  相似文献   

7.
We have developed a simple method for the microextraction of the carbamate pesticides carbofuran, pirimicarb, and carbaryl. It is termed ionic liquid magnetic bar microextraction (ILMB-ME) and based on an ionic liquid deposited on a magnetic stirrer bar placed in a sealed short PCR tube into which microholes where pinned. When placed in a vial containing the aqueous sample solution, the ILMB tumbles freely in the aqueous solution and the carbamates are extracted into the ionic liquid phase which then was determined by HPLC. The enrichment factors for carbofuran, pirimicarb, and carbaryl are 107, 94, 95, respectively. The limits of detection, calculated as three times the signal-to-noise ratio (S/N), are 1.4?μg?L?1 for carbofuran, 3.4?μg?L?1 for pirimicarb, and 1.7?μg?L?1 for carbaryl. The repeatability, carried out by extracting water samples spiked with carbamate levels of 200?μg?L?1, yielded relative standard deviations between 2.9 and 6.0?%, (for n?=?5). The recoveries of all the three fungicides from tap, lake and rain water samples at spiking levels of 5 and 50?μg?L?1 are in the range from 86 to 98?%, and from 80 to 96?%, respectively. We conclude that this is a simple, practical and efficient method for the determination of fungicide residues in real water samples.
Figure
?  相似文献   

8.
We have developed a fibre optic biosensor with incorporated magnetic microparticles for the determination of biogenic amines. The enzyme diamine oxidase from Pisum sativum was immobilized either on chitosan-coated magnetic microparticles or on commercial microbeads modified with a ferrofluid. Both the immobilized enzyme and the ruthenium complex were incorporated into a UV-cured inorganic–organic polymer composite and deposited on a lens that was connected, by optical fibres, to an electro-optical detector. The enzyme catalyzes the oxidation of amines under consumption of oxygen. The latter was determined by measuring the quenched fluorescence lifetime of the ruthenium complex. The limits of detection for the biogenic amines putrescine and cadaverine are 25–30 μmol?L?1, and responses are linear up to a concentration of 1 mmol L?1.
Figure
Response (fluorescence lifetime) of a novel optical biosensor for biogenic amines (putrescine, cadaverine) determination based on Pisum sativum diamine oxidase immobilized on magnetically responsive chitosan microparticles with entrapped magnetite encapsulated in inorganic–organic polymer ORMOCER® together with ruthenium complex.  相似文献   

9.
We describe the analytical performance of a hybrid material composed of SiO2, Al2O3 and TiO2. It was prepared by a sol–gel process and can act as an adsorbent in the continuous-flow enrichment of copper. A minicolumn was packed with the material, copper ions are adsorbed at pH 9.13, then eluted with 1.0?mol?L?1 nitric acid, and determined by FAAS. The material was characterized by infrared spectroscopy, scanning electron and energy dispersive spectroscopy, energy dispersive X-ray fluorescence analysis, powder X-ray diffraction, and specific surface area analysis. No significant interference was observed for most ions in up to copper/interferent ratios of 1:100 and of 1:500 in case of Ca(II), Ba(II), and Mg(II). The breakthrough capacity is 1.4?mg?g?1 under dynamic conditions. The limits of detection and of quantification are 0.50 and 1.4?μg?L?1, respectively, and the calibration plot is linear in the range from 5.0 to 245.0?μg?L?1 (r?=?0.999). The relative standard deviation is 3.20 (for n?=?7 and at a Cu(II) concentration of 10?μg?L?1). The method was applied to the determination of trace copper ions in water, vegetable and alcohol fuel samples.
Figure
We describe the analytical performance of the hybrid material composed of SiO2, Al2O3 and TiO2. It was prepared by a sol–gel process and can act as an adsorbent in the continuous-flow enrichment of copper. The method was applied to the determination of trace copper ions in water, vegetable and alcohol fuel samples.  相似文献   

10.
We have used a nano-structured nickel-aluminum layered double hydroxide (Ni-Al LDH) for the extraction of trace levels of selenium prior to its determination by continuous-flow hydride generation atomic absorption spectrometry. Extraction is based on the adsorption of Se(IV) anions on the Ni-Al-nitrate LDH, and/or their exchange with the nitrate anions in the LDH interlayer. The effects of pH value, amount of nanosorbent, eluent type and concentration, sample volume and flow rate were optimized. No appreciable matrix effects were observed. Under optimum conditions, the limit of detection (defined as three times the standard deviation of the blank signal divided by the slope of the calibration plot) is 10 pg?mL?1, and the relative standard deviation is 2.8 %. The sorption capacity and preconcentration factor are 10 mg?g?1 and 33, respectively. The method was successfully applied to the determination of Se(IV) in tap water, river water, well water, wastewater and oyster tissue (certified reference material, CRM 1566b).
Figure
Effect of NaOH concentration on elution of the retained Se(IV) ions from solid phase extraction column containing nickel-aluminum-nitrate layered double hydroxide nano-sorbent is shown. Combination of the sample preparation procedure with continuous flow hydride generation AAS exhibited excellent selectivity and sensitivity that could be exploited in determination of Se(IV) in various complicated matrices.  相似文献   

11.
We report on the synthesis and evaluation of aminated-CoFe2O4/SiO2 nanoparticles that can serve as a selective solid-phase sorbent for the extraction of cadmium ion. The nanoparticles consist of a magnetic CoFe2O4 core and an amino-modified silica shell. They can efficiently extract cadmium(II) ion and then can be isolated from the sample solution due to the magnetic nature of the core. The effects of the experimental conditions on the extraction process were optimized. Cadmium was then quantified by hydride generation atomic fluorescence spectrometry. The resulting calibration curve is linear in the concentration range of 0.01–10 μg?L?1, the instrumental detection limits (3σ) is 3.15 ng?L?1 and the relative standard deviation is 4.9 % at the 1.0 μg?L?1 level (for n?=?11). The enrichment factor is 50 (for 50 mL samples), and the adsorbent can be used for at least 45 cycles of preconcentration and elution. The method was applied to the determination of cadmium in environmental water samples, and successfully validated by analyzing two certified reference materials.
Figure
Magnetic solid-phase extraction coupled with hydride generation atomic fluorescence spectrometry for the determination of cadmium is described.  相似文献   

12.
We describe a simple, effective, inexpensive and rapid method for the determination of trace amounts of total inorganic arsenic in water samples by means of a modified solid phase preconcentration procedure using an aluminium hydroxide gel sorbent and hydride generation atomic fluorescence spectrometry (HGAFS). This method avoids the traditional extraction procedures that are time- and solvent-consuming. The effects of quantity of adsorbent, solution pH, adsorption time and potentially interfering ions were studied. Under the optimal conditions, the detection limit is 3 ng?L?1, and the enrichment factor is 167. The calibration plot is linear in the range from 0.05 to 10 μg?L?1, with a correlation coefficient of 0.9992. The relative standard deviation (RSD) was less than 6.1 % (n?=?5) and recoveries in spiked environmental water were >100 %. The method was successfully applied to the determination of total inorganic arsenic in natural water samples.
Figure
The above figure showed effect of adsorption time on recoveries of total inorganic arsenic. The adsorption rate of total inorganic arsenic on is very fast and it takes only several minutes to reach adsorption balance. After reaching adsorption balance, recoveries of total inorganic arsenic is up to 95 %.  相似文献   

13.
A method was developed for determination of inorganic anions, including nitrite (NO 2 ? ), nitrate (NO 3 ? ), bromide (Br?), and iodide (I?), in seawater by ion chromatography (IC). The IC system used two dilauryldimethylammonium bromide (DDAB)-coated monolithic ODS columns (50?×?4.6?mm i.d. and 100?×?4.6?mm i.d.) connected in series for separation of the ions. Aqueous NaCl (0.5?mol/L; flow rate, 3?mL/min) containing 5?mmol/L phosphate buffer (pH 5) was used as the eluent, and detection was with a UV detector at 225?nm. The monolithic ODS columns were coated and equilibrated with a 1-mmol/L DDAB solution (in H2O/methanol, 90:10 v/v). The hydrophilic ions (NO 2 ? , NO 3 ? , and Br?) were separated within 3?min and the retention time of I? was 16?min. No interferences from matrix ions, such as chloride and sulfate ions, were observed in 35?‰ artificial seawater. The detection limits were 0.6?μg/L for NO 2 ? , 1.1?μg/L for NO 3 ? , 70?μg/L for Br?, and 1.6?μg/L for I? with a 200-μL sample injection. The performance of the coated columns was maintained without addition of DDAB in the eluent. The IC system was successfully applied to real seawater samples with recovery rates of 94–108?% for all ions.
Figure
The hydrophilic ions (NO 2 ? , NO 3 ? , and Br?) and I? in seawater was determined by a single run using the IC system consisting of two dilauryldimethylammonium bromide (DDAB)-coated monolithic ODS columns (50?×?4.6?mm i.d. and 100?×?4.6?mm i.d.) connected in series, NaCl (0.5?mol/L; flow rate, 3?mL/min) containing 5?mmol/L phosphate buffer (pH 5) as the eluent, and a UV detector (225?nm). No interferences from matrix ions, such as chloride and sulfate ions, were observed in 35?‰ artificial and real seawaters.  相似文献   

14.
We report on a carbon paste electrode that was modified with a binuclear manganese(II) complex by the drop-coating method. A study on the mechanism of the electro-oxidation of tryptophan (Trp) at this electrode indicated that it enables Trp to be determined with good sensitivity and selectivity. Second-order derivative linear sweep voltammetry at pH 4.1 revealed that a sensitive anodic peak appears at 812?mV (vs. SCE) whose current is proportional to the concentration of Trp in the concentration range from 0.1 to 1.0???mol?L?1 and 1.0 to 80???mol?L?1, with a detection limit (S/N?=?3) of 0.08???mol?L?1 (60?s of accumulation). The method was applied to the determination of Trp in amino acid injection solutions with satisfactory results.
Figure
The electrochemical behavior of tryptophan at a carbon paste electrode modified with a binuclear manganese(II) complex Mn2(phen)2(p-MBA)4(H2O) was investigated. The modified electrode showed high electrocatalytic activity toward the oxidation of tryptophan and the peak current increases linearly with tryptophan concentration in the range of 0.1 to 80???mol L?1.  相似文献   

15.
The parasite Schistosoma mansoni (Sm) depends exclusively on the salvage pathway for its purine requirements. The enzyme purine nucleoside phosphorylase (PNP) is, therefore, a promising target for development of antischistosomal agents and an assay for screening of inhibitors. To enable this, immobilized SmPNP reactors were produced. By quantification of hypoxanthine by liquid chromatography, kinetic constants (K M) for the substrate inosine were determined for the free and immobilized enzyme as 110 ± 6.90 μmol?L ?1 and 164 ± 13.4 μmol?L ?1 , respectively, indicating that immobilization did not affect enzyme activity. Furthermore, the enzyme retained 25 % of its activity after four months. Non-Michaelis kinetics for the phosphate substrate, and capacity for Pi-independent hydrolysis were also demonstrated, despite the low rate of enzymatic catalysis. Use of an SmPNP immobilized enzyme reactor (IMER) for inhibitor-screening assays was demonstrated with a small library of 9-deazaguanine analogues. The method had high selectivity and specificity compared with screening by use of the free enzyme by the Kalckar method, and furnished results without the need for verification of the absence of false positives.
Figure
A cartoon illustrating the online SmPNP-IMER activity assay  相似文献   

16.
A new sorbent was prepared by immobilization of 2,6-diaminopyridine on activated carbon and then used as a solid-phase extractant for trace Au(III), Pd(II) and Pt(IV) before their determination by ICP-AES. Effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the potentially interfering ions were investigated. The optimum pH value is 1. The maximum static adsorption capacity for the three ions is 202.7, 38.5 and 30.1?mg?g?1, respectively. The adsorbed metal ions can be completely eluted by 2?mL of the eluent solution that contains 0.05?mol?L?1 HCl and 5% thiourea. Common other ions do not interfere. The detection limits (3??) are 0.16, 0.33 and 0.29?ng?mL?1, respectively. The relative standard deviation (RSD) was lower than 3.0% (n?=?8). The new sorbent was applied to the preconcentration of the three ions in ore and rock samples with satisfactory results.
Figure
Au(III), Pd(II), Pt(IV) are absorbed at pH 1. The maximum static adsorption capacity is 202.7, 38.5 and 30.1?mg?g?1. The eluent is 2?mL of the eluent solution that contains 0.05?mol?L?1 HCl and 5% thiourea. The relative standard deviation (RSD) was lower than 3.0% (n?=?8).  相似文献   

17.
A reagentless d-sorbitol biosensor based on NAD-dependent d-sorbitol dehydrogenase (DSDH) immobilized in a sol–gel carbon nanotubes–poly(methylene green) composite has been developed. It was prepared by durably immobilizing the NAD+ cofactor with DSDH in a sol–gel thin film on the surface of carbon nanotubes functionalized with poly(methylene green). This device enables selective determination of d-sorbitol at 0.2 V with a sensitivity of 8.7?μA?mmol?1?L?cm?2 and a detection limit of 0.11 mmol?L?1. Moreover, this biosensor has excellent operational stability upon continuous use in hydrodynamic conditions.
Figure
Reagentless D-sorbitol biosensor based on NAD-dependent D-sorbitol dehydrogenase (DSDH) immobilized in sol-gel/carbon nanotubes/poly(methylene green) composite  相似文献   

18.
We report on a novel method for on-line cloud point extraction (CPE) for preconcentration of cadmium ions. It is based on electromagnetic induction-assisted heating (EMIH) of iron particles in a packed bed contained in a quartz tube that acts as an on-line CPE enrichment column. The cadmium complex of 1-(2-pyridylazo)-2-naphthol is quantitatively retained by the column under the cloud point temperature with the help of EMIH. The column was then eluted with alcoholic borax buffer at room temperature and on-line coupled to FAAS. Under optimum conditions, the limit of detection (3 sb/b) and limit of quantification (10 sb/b) are 0.21 μg?L?1 and 0.70 μg?L?1 of Cd(II), respectively, and the relative standard deviation is 3.8 % (for n?=?8; at 20 ng?mL?1). An enhancement factor of 76 is typically achieved. The correlation coefficient of the calibration graph using the present method was 0.9986. The method was successfully applied to determine Cd(II) in water samples
Figure
An on-line cloud point extraction method was developed. Iron particles packed bed acts as an enrichment column. The cadmium complex of 1-(2-pyridylazo)-2-naphthol is quantitatively retained by the column under the cloud point temperature with the help of electromagnetic induction-assisted heating technique  相似文献   

19.
We report on the synthesis of Fe3O4-functionalized metal-organic framework (m-MOF) composite from Zn(II) and 2-aminoterephthalic acid by a hydrothermal reaction. The magnetic composite is iso-reticular and was characterized by FTIR, X-ray diffraction, SEM, magnetization, and TGA. The m-MOF was then applied as a sorbent for the solid-phase extraction of trace levels of copper ions with subsequent quantification by electrothermal AAS. The amount of sorbent applied, the pH of the sample solution, extraction time, eluent concentration and volume, and desorption time were optimized. Under the optimum conditions, the enrichment factor is 50, and the sorption capacity of the material is 2.4 mg g?1. The calibration plot is linear over the 0.1 to 10 μg L?1 Cu(II) concentration range, the relative standard deviation is 0.4 % at a level of 0.1 μg L?1 (for n?=?10), and the detection limit is as low as 73 ng L?1. We consider this magnetic MOF composite to be a promising and highly efficient material for the preconcentration of metal ions.
Figure
Magnetic metal-organic frameworks was synthesized and used as a new sorbent for lead adsorption with detection by electrothermal atomic absorption spectrometry.  相似文献   

20.
We report on the ion-exchange separation of Pt and Pd from the main elements emitted from catalysts of gasoline-fueled cars by exploiting the selective chelating ion exchanger Lewatit MonoPlus TP-214. Pt and Pd were then eluted with a recovery of 92% and 96%, respectively, using an acidified solution of thiourea, and the eluent was analyzed by sequential voltammetry. The detection limits are 0.04 μg L?1 and 1 μg L?1 for Pt and Pd, respectively, and the relative standard deviation is about 4.0% (for n?=?10). The procedure was successfully applied to particles emitted from automobile exhaust catalysts of four capacity engine vehicles. Graphite furnace atomic absorption spectrometry was also employed for reasons of comparison. Emission by four vehicles with 1400, 2600, 3200, and 4800 cc engines, respectively, ranged from 19 to 28 ng km?1 for Pt, and from 102 to 150 ng km?1 for Pd.
Figure
An ion-exchange separation of Pt and Pd from particles emitted from automotive catalysts with the Lewatit TP-214 was achieved. Pt and Pd were then eluted nearly quantitatively by an acidified solution of thiourea. Sequential voltammetry was successfully applied with detection limits of 0.04 μg Pt?L?1 and 1 μg Pd L?1.  相似文献   