首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 46 毫秒
1.
A novel type of united glucose oxidase (GOD) electrode was designed. Glucose oxidase and ferrocene (Fc), which was a mediator, were added into the composite electrode that was constructed by graphite powder, acetylene black, and epoxy resin. These three materials in composite electrode kept constant proportion in weight. And the optimum amounts of GOD and Fc among united enzyme electrode were 5% and 2%, respectively. The glucose was detected linearly in the concentration range 0.01–9.0 mM with a 20-s steady-state response time and 36 nA/mM of the sensitivity at 0.15 V applied potential. And electrode fouling problem and the response current from the interferents were avoided. The response current of the united GOD electrode had no obvious deterioration within 80 days when stored at 4°C in a refrigerator. The detecting results of human serum by the united GOD electrode had good consistency with that by standard enzyme method. The maximum deviation between these two detecting values was 5%. It might be used for detecting the blood sugar in clinical assay.  相似文献   

2.
聚吡咯葡萄糖氧化酶电极的生物电化学响应   总被引:2,自引:0,他引:2  
采用分步骤合过程,制备了以聚吡咯膜为载体的葡萄糖氧化酶电极,探讨了其生物电化学响应特性,计算了酶催化反应的有关动力学参数。与溶解态酶相比,该电极表现出良好的生物电化学特征,而且酶蛋白对溶液温度的稳定性有显著提高。  相似文献   

3.
基于壳聚糖膜固定双酶的胆碱传感器的研究   总被引:3,自引:0,他引:3  
提出了一种基于壳聚糖膜固定辣根过氧化物酶 胆碱氧化酶的胆碱传感器的制备方法。该传感器以电聚合于玻碳电极的硫堇作为电子传递介体,在pH6. 8,外加电压-0. 2V(vs.SCE)条件下,其峰电流与浓度范围 5. 0×10-5 ~3. 0×10-3 mol/L的胆碱呈良好的线性响应;检出限为 1. 0×10-5 mol/L。传感器有良好的选择性和稳定性,使用一月后,仍能保持其初始活性的 80%。  相似文献   

4.
铂黑修饰酶电极测定胆碱   总被引:2,自引:0,他引:2  
利用电化学方法在玻碳电极上均匀沉积亚微米粒度铂黑并进而修饰一层胆碱氧化酶膜,制成了胆碱酶电极。以计时电流法测定氯化胆碱,检测下限为 7.4 μmol/L,线性范围2.4×10-2~ 1.0 mmol/L,重现性好,使用寿命较长。  相似文献   

5.
A biosensor for glucose utilizing kinetics of glucose oxidase (EC 1.1.3.4.) was developed. The enzyme was immobilized on polyaniline by covalent bonding, using glutaraldehyde as a bifunctional agent. The system showed a linear response up to 2.2 mM of glucose with a response time of 2.5–4.0 min. In addition, the immobilized enzyme had a higher activity between pH 6.5 and 7.5. The system retained 50% of its activity after 30 d of daily use. The optical absorption spectra of the polyaniline/glucose oxidase electrode after glucose had been added to the buffer solution showed that the absorption band around 800 nm had changed considerably when glucose was allowed to react with the electrode. This optical variation makes polyaniline a very promising polymer for use as a support in optical sensor for clinical application.  相似文献   

6.
用聚苯胺膜从牛乳中直接分离黄嘌呤氧化酶   总被引:1,自引:0,他引:1  
酶电极;新鲜牛乳;固定分离;用聚苯胺膜从牛乳中直接分离黄嘌呤氧化酶  相似文献   

7.
《Analytical letters》2012,45(13):2455-2470
Abstract

An amperometric choline biosensor was constructed using choline oxidase immobilized on poly(2-hydroxyethylmethacrylate) membranes obtained by gamma radiation-induced polymerization at low temperature. The measurements were carried out by Clark-type oxygen or hydrogen peroxide electrodes. Calibration curves were linear in the 10-200 umol · 1?1 range for the oxygen probe and 5-250 umol · 1?1 for the H2O2-based probe. Temperature and pH effects on the activity of immobilized enzyme are described and the response characteristics of the sensor are summarized. The immobilized enzyme membranes stored in glycine buffer or in a dry state were very stable and no significant decrease in the electrode response was observed after three months. The biosensor was employed also to analyse a choline-containing pharmaceutical product and the results were compared to those obtained by enzymatic-spectrophotometric detection.  相似文献   

8.
李建平  彭图治 《中国化学》2002,20(10):1038-1043
IntroductionCholesterolisaveryimportantbioactivecompound .Numerousattemptshavebeenmadetocreatesensitive ,selective ,reliableandlowcostcholesterolsensorsduringthelastdecadebecauseofthesignificanceinclinicaldi agnosisofcoronaryheartdiseases ,arterioscleros…  相似文献   

9.
《Electroanalysis》2017,29(7):1741-1748
The determination of lead ions by inhibition of choline oxidase enzyme has been evaluated for the first time using an amperometric choline biosensor. Choline oxidase (ChOx) was immobilized on a glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNT) through cross‐linking with glutaraldehyde. In the presence of ChOx, choline was enzymatically oxidized into betaine at –0.3 V versus Ag/AgCl reference electrode, lead ion inhibition of enzyme activity causing a decrease in the choline oxidation current. The experimental conditions were optimised regarding applied potential, buffer pH, enzyme and substrate concentration and incubation time. Under the best conditions for measurement of the lowest concentrations of lead ions, the ChOx/MWCNT/GCE gave a linear response from 0.1 to 1.0 nM Pb2+ and a detection limit of 0.04 nM. The inhibition of ChOx by lead ions was also studied by electrochemical impedance spectroscopy, but had a narrower linear response range and low sensitivity. The inhibition biosensor exhibited high selectivity towards lead ions and was successfully applied to their determination in tap water samples.  相似文献   

10.
胡效亚  冷宗周 《分析化学》1995,23(4):416-418
本采用预活化聚酰膜固定多酚氧化酶并与浸蜡石墨极组合成传感器,测定儿茶酚的线范围2.×10-7-1.25×10^-5mol/L。检出限1.5×10^-7mol/L。酶的固定时间仅需1-2min,5个月之后被固定酶的活性未见下降,活性酶膜的制备,贮存,替换均很方便,对传感器的机理进行了探讨。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏