首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The electrodeposition of cadmium and copper on a special graphite disk electrode has been performed at controlled potential. The electrode with the deposit has been inserted into the graphite atomizer HGA-400 by an adapted automatic sampler for the final determination by ET-ASS. The sensitivity of determination has been 0.371 (gl-1)-1 for cadmium and 0.025 (gl-1)-1 for copper for 2 min electrodeposition and increased linearly with the time of deposition. The limit of detection (3sbl) has been 7.9 ngl-1 Cd2+ and 0.11 gl–1 Cu2+ for 2 min deposition and it has been improved with increased time of electrodeposition. The technique has been applied to the determination of both metals in seawater and to speciation in the presence of EDTA complexing agent.  相似文献   

2.
The statistical characteristics of the intracavity laser spectrometer are investigated by analysis of cesium in aqueous solutions. The error distribution of measurements is normal. The relative standard deviation of the analysis in the middle of the dynamic range is equal to 9.7%. The intracavity spectral analysis was carried out at low contents of cesium, manganese and terbium in aqueous solutions. The limits of detection are: 5 gl-1 (Cs), 20 gl-1 (Mn) and 1000 gl-1 (Tb). Owing to the high spectral resolution of the spectrometer used the hyperfine structure of the thallium absorption line (535.05 nm) was recorded.  相似文献   

3.
Summary A simple multi-residue procedure has been developed and applied to the analysis of pesticides in groundwater samples from the Comunidad Valenciana, a predominantly agricultural area on the Mediterranean coast of Spain. The procedure includes a liquid-liquid extraction, after addition of NaCl on the samples, and a subsequent analysis by capillary gas chromatography using a dual detection system with electron capture and nitrogen-phosphorous detectors. This allows the determination of more than 30 compounds (organophosphorous, organochlorine and pyrethroid pesticides) at the low ppb (g l–1) levels. Detection limits obtained varied between 0.01 g l–1 (lindane, fonofos) and 0.5 g l–1 (cypermethrin). An additional injection of the sample extracts into a gas chromatograph equipped with a column of different polarity and electron capture detector is used for the confirmation of chromatographic peaks. The recommended procedure has been applied to 66 ground water samples. Pesticides, including organophosphorus and organochlorine compounds were detected in 31 of them, in levels ranging from 0.02 to 0.7 g l–1.  相似文献   

4.
Summary Two packing materials, C18 and PLRP-S, are studied for on-line trace enrichment of phenolic compounds in water. Various precolumns of different internal diameter are also tested and the addition of an ion-pair reagent to increase retention and thus, breakthrough volumes of phenolic compounds, is studied. Best results are obtained when a PLRP-S precolumn is coupled on-line with a C18 analytical column and DAD detector. Addition of TBA considerably increases breakthrough volumes. In contrast, when a C18 precolumn is used, breakthrough volumes are lower and it is impossible to determine TCP and PCP, under the experimental conditions used, because of interference of other nonpolar compounds in the samples. The performance of the system is evaluated with river and tap water and the preconcentration of 10 ml of sample in a PLRP-S precolumn involves a linear range between 1 g 1–1 and 20 l–1 and limits of determination between 0.5 g l–1 and 1 g l–1 are obtained.  相似文献   

5.
Summary A gas chromatographic methodology with selective detection is presented for the analysis in wines and corks of pentachlorophenol residues, which are suspected to be the most likely precursors of some off-flavours described in several wine samples. After derivatisation, pentachlorophenol acetate residues were monitored by electrolytic conductivity detection and/or mass spectrometric detection in the selective ion mode at m/z 264 and 266. Recoveries varied from 80 to 96% for wine samples fortified with 5 to 100 g l–1 and from 83 to 91% for corks (fortified at 25 to 100 g kg–1). The proposed methodology allowed for a determination limit of g l–1 for wine and 10 g kg–1 for corks.  相似文献   

6.
The optimum conditions for the extractive spectrophotometric determination of dioxouranium(VI) with hexamethyleneiminecarbodithioate(HMICdt) have been established. Dioxouranium(VI) reacts with this ligand at pH 4.5 to form a yellowish-orange uncharged 12 metal-ligand complex which can be extracted by chloroform. The calibration graph was linear in the range of 1–20 g ml–1 of dioxouranium(VI) at 335 nm. The molar absorptivity of the extracted species is 5.952×103 l mol–1 cm–1 with Sandell's sensitivity of 0.04 g cm–2. The average of 10 determinations of dioxouranium was 49.75 g for the samples containing 50 g of U(VI) and the variation from the mean at 95% confidence limit was 49.75±0.5955.  相似文献   

7.
A comparative study of different chemical modifiers for the direct determination of arsenic in real and in synthetic sea water samples of high (72.8) and low (34.2) salinity was carried out. The use of lanthanum chloride and magnesium nitrate (LOD=3.0 gl-1) offers good recoveries for low salinities, while for high salinities an enhancement higher than 200% was obtained, rendering this method unsuitable for sea water samples. The use of silver nitrate (LOD=2.0 gl-1) produces unfavourable analytical recoveries, around 150 and 300% for synthetic sea water of low and high salinity. Zirconium oxychloride (LOD=1.8 gl-1) and palladium nitrate alone or combined with magnesium nitrate and reducing agents (LOD=1.1–1.3 gl-1) produce analytical recoveries close to 100% for all arsenic concentration tried over all salinities; thus, a single calibration curve using aqueous standard solutions may be applied to the analysis of sea water samples over all salinities. Finally, the addition of reducing agents and magnesium nitrate to palladium does not improve the sensitivity.  相似文献   

8.
The characteristics of knitted open tube (KOT) figure eight reactors and coil reactors at l/min flow rates were compared using plate height (H) calculations and peak height measurements. Peak broadening independent of flow rate was seen for the figure eight KOT but not the coil at flow rates of 150–300 l/min. Below 150 /min, the plate height values of both reactors were inversely proportional to flow rate. It was concluded that a 0.5-m KOT figure eight reactor is the most effective way to introduce delay time for a 1 1 injection size and tubing of 0.3 mm I.D. Enhancement of peak height response was particularly pronounced at flow rates less than 100 l/min.  相似文献   

9.
First- and second-derivative spectrophoto-metric methods for the simultaneous determination of aluminium and iron in their mixtures are described. The methods are based on the colored complexes formed by aluminium and iron with hematoxylin in the presence of cetyltrimethylammonium bromide as a surfactant. The zero-crossing method has been utilized to measure the first- and second-derivative value of the derivative spectrum. Aluminium (0.05–1 gml-1) could be determined in the presence of iron (0.09–1.6 gml-1) and vice versa. The detection limits of aluminium and iron are 0.01 and 0.09 gml-1, respectively in the first-derivative mode and 0.014 and 0.1 gml-1 in the second-derivative mode. The proposed method has been applied to the simultaneous determination of aluminium and iron in glasses, phosphate rocks, cement and magnesite alloy.  相似文献   

10.
    
Zusammenfassung Es werden Erfahrungen mit der Kombination von automatischem Aminosäurenanalysator und Szintillations-Durchflußzelle zur Bestimmung der spezifischen Radioaktivität 14C-markierter Aminosäuren im Gehirn mitgeteilt. Die Erfassungsgrenze beträgt 3 · 10–4 Ci/ml Eluat, die Reproduzierbarkeit 5–1% vom Mittelwert im Meßbereich von 1 · 10–3 bis 5 · 10–2 Ci.
A method for the determination of the specific radioactivity of free amino-acids in tissue extracts of mammals
Some experiences are given with a measuring device for the determination of the specific radioactivity of 14C-labelled brain amino-acids. The apparatus consists of an automatic amino-acid analyzer combined with a flow cell filled with anthracene. The reproducibility of the method is ±5% to ±1% m.e. in the range of 1×10–3 Ci to 5×10–2 Ci. A quantitative determination of 3×10–4 Ci/ml eluant is still possible.
  相似文献   

11.
The effect of cationic surfactants (cetyltrimethylammonium bromide, cetylpyridinium bromide, and tetrabutylammonium perchlorate) and a nonionic surfactant (OP-7) on the conditions of the immobilization of 4-(2-pyridylazo)resorcinol (PAR) on three types of silica gel (Silochrom S-120 (200–350 m), Silochrom S-120 (315–500 m), and Silochrom S-80 (200–350 m)) was studied. It was found that OP-7 does not affect the adsorption of surfactants. The effect of cationic surfactants increases in the order tetrabutylammonium perchlorate < cetyltrimethylammonium bromide < cetylpyridinium bromide. The adsorption activity of silica gels increases in the order Silochrom S-120 (315–500 m) < Silochrom S-80 (200–350 m) < Silochrom S-120 (200–350 m). Cetylpyridinium bromide provides full immobilization of PAR on silica gel Silochrom S-120 (200–350 m) in the pH range 2–9.  相似文献   

12.
Chemical behaviour of a helium muonide atom /Heo/ can be understood on the analogy of its hydrogen homologues, muonium /Mu/, deuterium /Do/ and tritium /To/. In muon catalyzed fusion /CF/, a small fraction of negative muon in the fusion cycle sticks to helium to give proton-like He+ which easily picks up one electron forming Heo. The energy of He+ at birth is about 3.5 MeV being in a similar situation to the case of a hot tritium atom produced by /n, p/ or /n, / reaction. The reaction cross section and rate of Heo reactions are estimated.  相似文献   

13.
We have studied the feasibility of producing57Co (271.3 d) via the55Mn(, 2n)57Co reaction (55Mn–100%). The thick target yield of57Co in the 28 to 18 MeV energy region was measured as 3.87 Ci/Ah. However, the proximity and overlap of the excitation functions for (, n), (, 2n) and (, 3n) reactions on55Mn are such that the production of pure57Co in high yields free of58Co (70.8 d) and56Co (78.8 d) has not been feasible. We have also studied a new method for ancillary production of57Co via the reactions58Ni(, p)57Co and during the course of producing62Zn by60Ni(, 2n)62Zn reaction. In this case the yield of57Co of reasonable purity has been up to 1 Ci/Ah.  相似文献   

14.
The reaction of the tetranuclear trimethylacetate complex Co4(3-OH)2(-OOCCMe3)4(2-OOCCMe3)2(EtOH)6 with pyridine in acetonitrile was studied. Two new compounds, viz., the hexanuclear cobalt(ii) complex Co6py4(3-OH)2(-OOCCMe3)10 (25% yield) and the unusual ionic compound [Co3py3(3-O)(-OOCCMe3)6]+[Co4py(4-O)(-OOCCMe3)7] (5% yield), were prepared. The structures of the new compounds were established by X-ray diffraction analysis.  相似文献   

15.
Fluoride and sulphate complexing of Np(VI) has been studied by controlled-potential coulometry at a constant ionic strength. The values of 1 * and 2 * for fluoride complexes were found to be 9.4 and 8.9, respectively, at an ionic strength =0.5. At an ionic strength =1.0, 1 * and 2 * obtained were 6.6 and 10.5, respectively. Sulphate complexing of Np(VI) was studied only at an ionic strength =0.5. The value of 1 * obtained was 5.6.  相似文献   

16.
Summary Sulphate in the range of 5–2000 mol · l–1 is automatically titrated with Ba(II) in a device with an optical detection which is able to correct automatically for dilution and turbidities. The flow-through system contains 80% v/v ethanol; the indicator is dimethyl sulfonazo(III). Above a concentration level of about 20 mol · l–1 SO 4 2– the standard deviation is less than 5% rel. The titration time is negligibly small as compared to the sampling time.
Titrimetrie im DurchflußsystemI. Apparatur und Sulfatbestimmung
Zusammenfassung Sulfat wird im Bereich von 5–2000 mol · l–1 automatisch mit Ba(II) mit einem Gerät mit optischer Detektion titriert, das automatisch für Verdünnung und Trübung korrigieren kann. Das Durchflußsystem enthält 80% v/v Äthanol; Indicator ist Dimethylsulfonazo(III). Die Standardabweichung für Proben mit einem Sulfatgehalt höher als 20 mol · l–1 ist niedriger als 5% rel. Die Titrationsdauer ist vernachlässigbar im Vergleich mit der Zeit für die Probennahme.
  相似文献   

17.
    
Summary Optimum for the generation of arsine from As(III) and (V) in a generating system without carrier gas and with atomization in an air-acetylene flame were established. A 3% solution of NaBH4 was used as reducer. The effect of 26 different species on the determination of arsenic was studied. The method has been applied to determine arsenic in copper.A linear relationship exists between 0.5 and 3 g for As(III) and between 1 and 4 total g of As(V). The sensitivity, expressed as the slope of the calibration curve is 0.067 g–1 for As(III) and 0.054 g–1 for As(V); the characteristic masses are 1.22 g and 0.44 g, and the limits of detection 0.27 g and 0.33 g, respectively.
Direkte Flammen-AAS — Erzeugung flüchtiger kovalenter HydrideStörungen durch das Verhältnis der As(III/V)-Valenzstufen und Arsenbestimmung in Kupfer
Zusammenfassung Optimale Bedingungen wurden ausgearbeitet für die Arsinerzeugung aus As(III) und As(V) in einem System ohne Trägergas mit Atomisierung in einer Luft-Acetylen-Flamme. Zur Reduktion dient eine 3%ige NaBH4-Lösung. Der Einfluß von 26 Fremdionen wurde geprüft und das Verfahren zur Arsenbestimmung in Kupfer angewendet. Eine lineare Beziehung ergab sich für 0,5–3 g As(III) und 1–4 g As(V). Die Empfindlichkeit (als Neigung der Eichkurve) beträgt 0,067 g–1 für As(III) und 0,054 g–1 für As(V). Die charakteristischen Massen sind 1,22 g bzw. 0,44 g und die Nachweisgrenzen 0,27 g bzw. 0,33 g.


This work has been sponsored by the CAICYT (project 3378/83) of the Spanish Education and Science Department.  相似文献   

18.
Some modifications of the stannous chloride reduction method for the estimation of inorganic phosphate reported by Berenblum-Chain are suggested. By this method, it is possible to measure 25 g l–1 of phosphorus /P/ as inorganic phosphate in the presence of macromolecules like deoxyribonucleic acid /100 g ml–1/, as compared to 200 g l–1 of P by the original method. If a larger sample volume /30 ml/ is used, even 5 g l–1 of P can be measured.  相似文献   

19.
Summary A rapid ion-exchange method for the determination of 144Ce, 137Cs, 89Sr, 90Sr and 140Ba in 2–30 liter samples of atmospheric water precipitations is described. The samples, containing up to 300 mg of calcium, are sorbed on a specially shaped column filled with Dowex 50, X-8 or Dowex 50W, X-8. Radio-cerium and radio-caesium are stripped from the column with 0.6 M ammonium glycolate/ 0.2 M NaCl, pH 5, radio-strontium and radio-barium with 0.15 M ammonium citrate, pH 7.5. The isolated radio-nuclides are counted on a low-background beta-counter: 144Ce as CeO2, 137Cs as Cs-dipicrylaminate, 89Sr/90Sr as SrCO3, 90Y as Y2O3, and 140Ba as BaCO3. The mean chemical yields amount to 95% for cerium, 85% for caesium, 95% for strontium, 95% for yttrium and 65% for barium. With parallel determinations at levels of a few picocuries, the deviations of the results from the respective mean values generally do not exceed ± 5%. With a 30 l sample the limit of detection amounts to 0.005 Ci/l for 144Ce, 0.006 Ci/l for 137Cs, 0.005 Ci/l for 90Sr, and 0.006 Ci/l for 140Ba.
Zusammenfassung Es wird eine schnelle Ionenaustauschmethode für die Bestimmung von 144Ce, 137Cs, 89Sr, 90Sr und 140Ba in 2–30 l Proben von atmosphärischen Wasser-Niederschlägen beschrieben. Die Proben, mit einem Calciumgehalt bis zu 300 mg, werden in eine besonders gestaltete, mit Dowex 50, X-8 oder Dowex 50 W, X-8 gefüllte Säule eingewaschen. Radio-Cer und Radio-Caesium werden mit 0,6 M Ammoniumglykolat/0,2 M NaCl, pH 5, Radio-Strontium und Radio-Barium mit 0,15 M Ammoniumcitrat pH 7,5 eluiert. Die isolierten Radio-Nuklide werden in einem Beta-Antikoinzidenzzähler gemessen: 144Ce als CeO2, 137Cs als Cs-dipikrylaminat, 89Sr/90Sr als SrCO3, 90Y als Y2O3 und 140Ba als BaCO3. Die mittlere Rückgewinnung der zugesetzten Träger beträgt für Cer 95%, 85% für Caesium, 95% für Strontium, 95% für Yttrium und 65% für Barium. In Parallelbestimmungen mit Gehalten von einigen Ci/l, überschreiten die Abweichungen der Ergebnisse von den entsprechenden Mittelwerten im allgemein nicht 5%. Bei einer 30 l-Probe beträgt die untere Nachweisgrenze 0,005 Ci/l für 144Ce, 0,006 Ci/l für 137Cs, 0,005 Ci/l für 90Sr und 0,006 Ci/l für 140Ba.
  相似文献   

20.
Xu  Feng  Chen  Yong-Mei  Yang  Shi-Yan  Sun  Wen-Hua  Yu  Kai-Bei 《Transition Metal Chemistry》2000,25(1):108-111
CpMoFeCo(CO)7(3-S) reacts with Cp*M(CO)3Cl or CpM(CO)3Cl (M=W, Mo) to gave the mixed-metal clusters Cp*WCpMoFe(CO)7(3-S) (1), Cp*MoCpMoFe(CO)7(3-S) (2), CpWCp*MoFe(CO)7(3-S) (3), CpMoCp*MoFe(CO)7(3-S) (4) and Cp*WCp*MoFe(CO)7(3-S) (5). The title clusters have been characterized by i.r., 1H/13C-n.m.r. spectroscopy and their compositions have been confirmed by elemental analyses. The X-ray crystal structure analysis shows the two independent enantiomeric molecules of clusters (1) in one crystal structure unit.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号