This study demonstrates the application of 2,5-dihydrohybenzoic acid/aniline (DHB/An) and 2,5-dihydroxybenzoic acid/N,N-dimethylaniline (DHB/DMA) matrices for automated identification and quantitative analysis of native oligosaccharides by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Both matrices are shown to be superior to pure DHB for native glycans in terms of signal intensities of analytes and homogeneity of sample distribution throughout the crystal layer. On-target formation of stable aniline Schiff base derivatives of glycans in DHB/An and the complete absence of such products in the mass spectra acquired in DHB/DMA matrix provide a platform for automated identification of reducing oligosaccharides in the MALDI mass spectra of complex samples. The study also shows how enhanced sensitivity is achieved with the use of these matrices and how the homogeneity of deposited sample material may be exploited for quick and accurate quantitative analysis of native glycan mixtures containing neutral and sialylated oligosaccharides in the low-nanogram to mid-picogram range.  相似文献   

2.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a powerful tool for the analysis and characterization of protein phosphorylation on the peptide level. In this study, the applicability of ionic liquid matrices (ILM) formed by combination of the crystalline MALDI matrix 2,5-dihydroxybenzoic acid (DHB) with pyridine or n-butylamine was tested for the analysis of phosphopeptides. Low ionization efficiency in both positive and negative ion mode was observed in acid-free sample preparations. Upon addition of 0.1% trifluoroacetic acid (TFA), ion formation was increased, but analogously to the situation described earlier for pure DHB, best results were obtained upon use of 1% phosphoric acid as matrix additive. The samples prepared in this way were significantly more homogeneous than preparations with pure DHB, thus avoiding the need for time-consuming search for hot spots. Other characteristics like metastable fragmentation of phosphopeptides did not differ from that observed in classical preparations. The limits of detection for synthetic phosphopeptides and singly or multiply phosphorylated peptides from tryptic digests of alpha- and beta-casein were comparable with those obtained when using pure DHB; in some cases even higher signal intensities could be observed in the ILM. The use of ILM in combination with 1% phosphoric acid as matrix additive significantly facilitates analysis of phosphopeptides by MALDI-MS.  相似文献   

3.
In this study we report an improved protocol that combines simplified sample preparation and micro-scale separation for mass spectrometric analysis of neuropeptides from individual neuroendocrine organs of crab Cancer borealis. A simple, one-step extraction method with commonly used matrix-assisted laser desorption/ionization (MALDI) matrix, 2,5-dihydroxybenzoic acid (DHB), in saturated aqueous solution, is employed for improved extraction of neuropeptides. Furthermore, a novel use of DHB as background electrolyte for capillary electrophoresis (CE) separation in the off-line coupling of CE to MALDI-Fourier transform mass spectrometric (FT-MS) detection is also explored. The new CE electrolyte exhibits full compatibility with MALDI-MS analysis of neuropeptides in that both the peptide extraction process and MALDI detection utilize DHB. In addition, enhanced resolving power and improved sensitivity are also observed for CE-MALDI-MS of peptide mixture analysis. Collectively, the use of DHB has simplified the extraction and reduced the sample loss by elimination of homogenizing, drying, and desalting processes. In the mean time, the concurrent use of DHB as CE separation buffer and subsequent MALDI matrix offers improved spectral quality by eliminating the interferences from typical CE electrolyte in MALDI detection.  相似文献   

4.
陈君  殷俊  高帅  许莉  肖宏展 《分析化学》2012,(3):421-426
通过比较两种极性差异较大的基质2,5-二羟基苯甲酸(DHB)和2’,6’-二羟基苯乙酮(DHAP)按不同比例混合时,AngiotensinⅡ的基质辅助激光解析电离-傅立叶变换离子回旋共振质谱(MALDI-FT/ICRMS)谱图的不同,并结合基质-AngiotensinⅡ在不同结晶方式下的共结晶和基质晶体的扫描电镜照片,发现基质为10μmol/L DHB和15μmol/L DHAP以体积比4:1组成的混合物时,基质结晶为致密的层状结构,而以薄层法与AngiotensinⅡ生成的共结晶,AngiotensinⅡ在基质晶体上面形成分散的柱状小晶体,此时得到的MALDI-FT/ICRMS质谱图优于干滴法。  相似文献   

5.
The protocol and various matrices were examined for quantification of biomolecules in both the low ca. 1200 amu and mid mass 6000-12000 amu ranges using an internal standard. Comparative studies of different matrices of MALDI quantitative analysis showed that the best accuracy and standard curve linearity were obtained for two matrices: (a) 2,5-dihydroxybenzoic acid (DHB) combined with a comatrix of fucose and 5-methoxysalicylic acid (MSA) and (b) ferulic acid/fucose. In the low mass range, the quantitative limit was in the 30 fmol range and in the mid mass range the quantitative limit was in the 250 fmol range. Linear response was observed over 2-3 decades of analyte concentration. The relative error of the standard curve slope was 1.3-1.8% with correlation coefficients of 0.996-0.998.The main problem for quantitative measurement was suppression of the signal of the less concentrated component (analyte or internal standard) by the more concentrated component. The effect was identified with saturation of the matrix by the analyte. The threshold of matrix saturation was found to be in the range of 1/(3000-5000) analyte/matrix molar ratio. To avoid matrix saturation the (analyte+internal standard) to matrix molar ratio should be below this threshold. Thus the internal standard concentration should be as low as possible.DHB/MSA/fucose and ferulic acid/fucose matrices demonstrated good accuracy and linearity for standard curves even when the internal standard had chemical properties different from the analyte. However, use of an internal standard with different chemical properties requires highly stable instrumental parameters as well as constant (analyte+internal standard)/matrix molar ratio for all samples.  相似文献   

6.
The protocol and various matrices were examined for quantification of biomolecules in both the low ca. 1200 amu and mid mass 6000–12000 amu ranges using an internal standard. Comparative studies of different matrices of MALDI quantitative analysis showed that the best accuracy and standard curve linearity were obtained for two matrices: (a) 2,5-dihydroxybenzoic acid (DHB) combined with a comatrix of fucose and 5-methoxysalicylic acid (MSA) and (b) ferulic acid/fucose. In the low mass range, the quantitative limit was in the 30 fmol range and in the mid mass range the quantitative limit was in the 250 fmol range. Linear response was observed over 2–3 decades of analyte concentration. The relative error of the standard curve slope was 1.3–1.8% with correlation coefficients of 0.996–0.998.The main problem for quantitative measurement was suppression of the signal of the less concentrated component (analyte or internal standard) by the more concentrated component. The effect was identified with saturation of the matrix by the analyte. The threshold of matrix saturation was found to be in the range of 1/(3000–5000) analyte/matrix molar ratio. To avoid matrix saturation the (analyte+internal standard) to matrix molar ratio should be below this threshold. Thus the internal standard concentration should be as low as possible.DHB/MSA/fucose and ferulic acid/fucose matrices demonstrated good accuracy and linearity for standard curves even when the internal standard had chemical properties different from the analyte. However, use of an internal standard with different chemical properties requires highly stable instrumental parameters as well as constant (analyte+internal standard)/matrix molar ratio for all samples.  相似文献   

7.
D-Glucose and 19 glucose derivatives were investigated by positive and negative ion matrix assisted laser desorption/ionization time-of-flight mass spectrometry using 2,5-dihydroxybenzoic acid (DHB) as the matrix. The set of substrates includes oligomers of amylose and cellulose, native alpha-, beta-, and gamma-cyclodextrin, and chemically modified beta- and gamma-cyclodextrins. These analytes were chosen to modulate molecular weight, polarity, and capability of establishing noncovalent interactions with guest molecules. In the negative-ion mode, the DHB matrix gave rise to charged multicomponent adducts of type [M + DHB - H]- (M = oligosaccharide) selectively for those analytes matching the following conditions: (i) underivatized chemical structure and (ii) number of glucose units > or = 4. In the positive-ion polarity, only some amylose and cellulose derivatives and methylated beta-cyclodextrins provided small amount of cationized adducts with the matrix of type [M + DHB + X]+ (X = Na or K), along with ubiquitous [M + X]+ ions. The results are discussed by taking into account analyte-matrix association phenomena, such as hydrogen bond and inclusion phenomena, as a function of the molecular structure of the analyte. The conclusions derived by mass spectrometric data are compared with the X-ray diffraction data obtained on a single crystal of the 1:1 alpha-cyclodextrin - DHB noncovalent adduct.  相似文献   

8.
A novel matrix of isoliquiritigenin (ISL), a flavonoid with a chalcone structure (4,2′,4′-trihydroxychalcone), was demonstrated to be advantageous in the analysis of neutral oligosaccharides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). With ISL as a matrix, adequate signal for an analyte can be obtained in much lower matrix concentrations and laser intensity compared to commonly used MALDI matrices. Four different sample preparation methods were tested, and the dried droplet method exhibited the best performance on MALDI-TOF-MS analysis of oligosaccharides with ISL as a matrix. For the analysis of carbohydrates, compared with popular matrices such as 2,5-dihydroxybenzoic acid (DHB) and 2,4,6-trihydroxyacetophenone (THAP), ISL exhibited outstanding matrix properties as follows: (1) higher homogeneity of crystallization thus allowing automatic data acquisition, (2) better spectral quality in terms of resolution and signal to noise ratio (S N−1), (3) better salt tolerance, (4) higher sensitivity, and (5) enough fragmentation yield to use LIFT-TOF/TOF MS to get richer structural information. In addition, reliable quantitative analysis of oligosaccharides with a good linearity over two concentration orders (1–100 pmol μL−1) and good reproducibility of the signal intensity (RSD less than 15%) were achieved using this matrix. These results give a new outlook on high-speed analysis of neutral carbohydrates by MALDI-TOF MS.  相似文献   

9.
Negative-ion matrix-assisted laser desorption/ionization mass spectra of sialylated glycoconjugates were acquired employing 2,5-dihydroxybenzoic acid (DHB) in conjunction with spermine as a co-matrix. The addition of spermine to DHB permitted an improved crystal formation as well as a higher analyte solubility. Moreover, DHB/spermine appears to minimize alkali adduct formation, thus allowing the sample analysis without desalting. The combined matrix permitted the analysis of complex sialylated and sialylated/fucosylated structures down to the femtomole range. The ability to use such a matrix also facilitates determination of the sialic acid linkages (in combination with a specific enzyme cleavage). The matrix also appears suitable for studies on gangliosides.  相似文献   

10.
利用水热法合成出NH4Y3F10多孔纳米晶。由于Y3+离子的激发态能量可以转移给具有较高振动能的有机分子,因此这些多孔纳米晶可以作为基质辅助激光解析电离飞行时间质谱的基体材料,用于检测小分子和聚乙二醇。通过与商品化的基体材料(CHCA、DHB)对比,证明NH4Y3F10多孔纳米晶是一种性能优异的基体材料。这种新型基体材料已经成功应用于有机分子、小肽、C60、缺氧诱导因子(HIFs)和聚乙二醇的分子量的检测,显示出这种基体材料具有广泛的应用前景。  相似文献   

11.
Application of matrix‐assisted laser‐desorption/ionization mass spectrometry (MALDI MS) to analysis and characterization of phosphopeptides in peptide mixtures may have a limitation, because of the lower ionizing efficiency of phosphopeptides than nonphosphorylated peptides in MALDI MS. In this work, a binary matrix that consists of two conventional matrices of 3‐hydroxypicolinic acid (3‐HPA) and α‐cyano‐4‐hydroxycinnamic acid (CCA) was tested for phosphopeptide analysis. 3‐HPA and CCA were found to be hot matrices, and 3‐HPA not as good as CCA and 2,5‐dihydroxybenzoic acid (DHB) for peptide analysis. However, the presence of 3‐HPA in the CCA solution with a volume ratio of 1:1 could significantly enhance ion signals for phosphopeptides in both positive‐ion and negative‐ion detection modes compared with the use of pure CCA or DHB, the most common phosphopeptide matrices. Higher signal intensities of phosphopeptides could be obtained with lower laser power using the binary matrix. Neutral loss of the phosphate group (?80 Da) and phosphoric acid (?98 Da) from the phosphorylated‐residue‐containing peptide ions with the binary matrix was decreased compared with CCA alone. In addition, since the crystal shape prepared with the binary matrix was more homogeneous than that prepared with DHB, searching for ‘sweet’ spots can be avoided. The sensitivity to detect singly or doubly phosphorylated peptides in peptide mixtures was higher than that obtained with pure CCA and as good as that obtained using DHB. We also used the binary matrix to detect the in‐solution tryptic digest of the crude casein extracted from commercially available low fat milk sample, and found six phosphopeptides to match the digestion products of casein, based on mass‐to‐charge values and LIFT TOF‐TOF spectra. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
The peak intensities obtained when 2,5-dihydroxybenzoic acid (DHB) was used as a 'classic' matrix were measured using substance P (SP) and betacyclodextrin (BCD) as analytes. Enhancements in peak intensities were observed going from 1:1 MeOH/H2O to dimethylforamide (DMF) as matrix solvents. Also non-covalent interactions between SP and solvent and DHB were observed suggesting close interactions between matrix, solvent and analyte in the gas-phase. Peak enhancements were previously reported with 'superDHB' (DHB and 2-hydroxy-5-methoxybenzoic acid at 10% v/v). Co-addition of structural analogues and their respective absorption coefficients were determined. It was found that other analogues used as co-matrices could give analyte peak enhancement similar to reported for sDHB with the additional benefit that some analogues could act as matrices with DHB addition. No direct correlation was observed between absorption coefficient and the ability of the molecule to act as a 'good' UV MALDI matrix.  相似文献   

13.
We introduce a two-component matrix for ultraviolet matrix-assisted laser desorption/ionization mass spectrometry (UV-MALDI-MS) that consists of 2,5-dihydroxybenzoic acid (DHB) and glycerol. Upon slow evaporation of residual water/methanol solvents in a pre-vacuum chamber sample preparations are obtained that exhibit a homogeneous morphology with analyte-matrix crystals evenly distributed over the whole sample spot. At a molar DHB/glycerol ratio of approximately 1:5, the crystals range in length from approximately 100 to 300 microm and are about 15-30 microm wide. Mass spectra of peptides, proteins, and an oligosaccharide are presented and compared with those recorded from standard dried-droplet DHB matrix. The ion signals show a reproducibility of the order of 10-15% when scanning the surface of an individual sample or even different samples that contain the same amount of peptide, A close to linear relationship between peptide concentration and the corresponding peptide ion signal is found over three orders of magnitude of sample prepared. However, when a fixed position is irradiated with a large number of laser pulses, a monotonous decay of peptide ion signal with time is observed. Potentially, the binary matrix will be especially useful for the analysis of samples that are stabilized in buffered aqueous glycerol solution and preliminary results addressing this aspect are shown.  相似文献   

14.
Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry was used for qualitative and quantitative end-group analysis of a small molecular weight polyester, poly(2-butyl-2-ethyl-1,3-propylene phthalate). The presence of carboxyl-terminated linear and cyclic polyester oligomers was confirmed with the help of simple sample preparation methods. The presence of carboxyl end-groups in the polyester chains was verified through their formation of carboxylate salts with alkali metal cations. Cyclic oligomers were identified through deuterium exchange of the exchangeable protons of the polyester. Various inorganic salts were tested for salt formation of the carboxyl end-groups, but only the alkali metal salts proved effective. The influence of the alkali metal salts on the results of the quantitative end-group analysis was also studied. The relative amounts of differently terminated and cyclic oligomers were calculated when the alkali metal salts were used with different matrices. The results showed that both the salts and the matrices used in sample preparation can have a marked effect on the quantitative results of the end-group analysis. The measurements were carried out using 2,5-dihydroxybenzoic acid (DHB), 1,8, 9-trihydroxyanthracene (dithranol), and 2-(4-hydroxyphenylazo)benzoic acid (HABA) as matrix compounds. Dithranol and HABA repeatably exhibited similar results, and these results differed from those obtained with DHB probably because of the different ionization mechanisms in the MALDI process. Copyright-Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

15.
Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) is an excellent analytical technique for rapid analysis of a variety of molecules with straightforward sample pretreatment. The performance of MALDI‐TOF MS is largely dependent on matrix type, and the development of novel MALDI matrices has aroused wide interest. Herein, we devoted to seek more robust MALDI matrix for herbal saponins than previous reported, and ginsenoside Rb1, Re, and notoginsenoside R1 were used as model saponins. At the beginning of the present study, 2,5‐dihydroxybenzoic acid (DHB) was found to provide the highest intensity for saponins in four conventional MALDI matrices, yet the heterogeneous cocrystallization of DHB with analytes made signal acquisition somewhat “hit and miss.” Then, graphene oxide (GO) was proposed as an auxiliary matrix to improve the uniformity of DHB crystallization due to its monolayer structure and good dispersion, which could result in much better shot‐to‐shot and spot‐to‐spot reproducibility of saponin analysis. The satisfactory precision further demonstrated that minute quantities of GO (0.1 μg/spot) could greatly reduce the risk of instrument contamination caused by GO detachment from the MALDI target plate under vacuum. More importantly, the sensitivity and linearity of the standard curve for saponins were improved markedly by DHB‐GO composite matrix. Finally, the application of detecting the Rb1 in complex biological sample was exploited in rat plasma and proved it applicable for pharmacokinetic study quickly. This work not only opens a new field for applications of DHB‐GO in herbal saponin analysis but also offers new ideas for the development of composite matrices to improve MALDI MS performance.  相似文献   

16.
High-sensitivity, high-throughput analysis of proteins for proteomics studies is usually performed by polyacrylamide gel electrophoresis in combination with mass spectrometry. However, the quality of the data obtained depends on the in-gel digestion procedure employed. This work describes an improvement in the in-gel digestion efficiency for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) analysis. A dramatic improvement in the coverage of tryptic peptides was observed when n-octyl glucoside was added to the buffer. Whole cell extracted proteins from S. cerevisiae were separated by two-dimensional gel electrophoresis and stained with silver. Protein spots were identified using our improved in-gel digestion method and MALDI-TOFMS. In addition, the mass spectra obtained by using the matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) were compared with those obtained using 2,5-dihydroxybenzoic acid (DHB). The DHB matrix usually gave more peaks, which led to higher sequence coverage and, consequently, to higher confidence in protein identification. This improved in-gel digestion protocol is simple and useful for protein identification by MALDI-TOFMS.  相似文献   

17.
应用基体辅助激光解吸电离飞行时间质谱(MALDI-TOFMS)直接对未经分级的高聚合度(n>100)葡聚糖样品进行了测定,检测到的葡聚糖最大分子量达18000以上.对2,5-二羟基苯甲酸(DHB)、1-羟基异喹啉(1-HIQ)及3,4-二羟基肉桂酸(咖啡酸,CA)3种一元基体以及DHB与1-HIQ,DHB与CA两种二元基体在测定中的作用进行了比较.结果表明,DHB基体测定的质量范围较大;DHB+1-HIQ和DHB+CA二元混合基体对样品的解吸电离效果及谱图重现性好;DHB+1-HIQ基体获得的谱图分辨率高.  相似文献   

18.
2,5‐Dihydroxybenzoic acid (DHB) is one of the most widely used and studied matrix compounds in matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry. However, the influence of ageing of the DHB solution on the MALDI mass spectra has not been yet systematically studied. In this work, the possible changes occurring in the acidified acetonitrile/water solution of the MALDI matrix compound DHB during 1‐year usage period have been monitored with MALDI‐Fourier transform ion cyclotron resonance mass spectrometer (MALDI‐FT‐ICR‐MS) and attenuated total reflectance Fourier transform infrared (ATR‐FT‐IR) spectroscopy. No significant ageing products have been detected. The ability of the aged DHB solution to act as a MALDI matrix was tested with two materials widely used in art and conservation – bone glue (a proteinaceous material) and shellac resin (a resinous material) – and good results were obtained. A number of peaks in the mass spectra measured from the DHB solution were identified, which can be used for internal calibration of the mass axis. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
Different matrices and sample-matrix preparation procedures have been tested in order to study their influence on the matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectra of intact glycoproteins, which present different degrees of glycosylation (human transferrin; bovine fetuin; bovine alpha(1)-acid-glycoprotein; recombinant human erythropoietin; and the novel erythropoiesis stimulating protein). Using sinapinic acid (SA) and the fast evaporation method, the studied glycoproteins became susceptible to fragmentation at any laser intensity, suggesting that this 'hot' matrix is unsuitable for a reliable molecular mass determination of glycosylated compounds. In contrast, 2,5-dihydroxybenzoic acid (DHB) and 6-aza-2-thiothymine (ATT), with an adequate sample-matrix preparation, provided improved results. Samples containing DHB after crystallization by vacuum drying demonstrated the best performance because the labile functional groups from the glycoforms were apparently fragmented to a lower extent. The average molecular masses obtained using this methodology were in all cases a better estimation than those values reported in the literature. The results were reproducible, and sensitivity was similar to that obtained with SA and the fast evaporation method. These excellent results suggest that this MALDI-TOF-MS methodology could be useful for an improved determination of the average molecular mass values of microheterogeneous compounds such as glycoproteins, glycosylated compounds or, in general, molecular mass values of molecules with similar labile functional groups.  相似文献   

20.
The use of collision-induced dissociation, postsource decay (CID-PSD) matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for the analysis of small organic molecules is demonstrated. Three pesticides: paraquat, diquat, and difenzoquat were chosen for this study. The matrices 2,5-dihydroxybenzoic acid (DHB), alpha-cyano-4-hydroxycinnamic acid (alpha-CHCA), and sinapinic acid (SA) were selected to investigate the effect of the matrix on the CID-PSD MALDI spectra of these molecules. Alpha-CHCA and DHB were found to be appropriate matrices for the pesticides studied. Spectra for a given pesticide obtained from different matrices were compared with each other, and the differences between them are discussed. A comparison of CID-PSD MALDI with fast-atom bombardment MS/MS spectra is presented; the agreement of pesticide fragmentation patterns between the two methods indicates that CID-PSD MALDI MS is a reliable and efficient technique for structural elucidation of small molecules.  相似文献   