首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Cell-based microfluidic devices have attracted interest for a wide range of applications. While optical cell counting and flow cytometry-type devices have been reported extensively, sensitive and efficient non-optical methods to detect and quantify cells attached over large surface areas within microdevices are generally lacking. We describe an electrical method for counting cells based on the measurement of changes in conductivity of the surrounding medium due to ions released from surface-immobilized cells within a microfluidic channel. Immobilized cells are lysed using a low conductivity, hypotonic media and the resulting change in impedance is measured using surface patterned electrodes to detect and quantify the number of cells. We found that the bulk solution conductance increases linearly with the number of isolated cells contributing to solution ion concentration. The method of cell lysate impedance spectroscopy is sensitive enough to detect 20 cells microL(-1), and offers a simple and efficient method for detecting and enumerating cells within microfluidic devices for many applications including measurement of CD4 cell counts in HIV patients in resource-limited settings. To our knowledge, this is the most sensitive approach using non-optical setups to enumerate immobilized cells. The microfluidic device, capable of isolating specific cell types from a complex bio-fluidic and quantifying cell number, can serve as a single use cartridge for a hand-held instrument to provide simple, fast and affordable cell counting in point-of-care settings.  相似文献   

2.
We present a novel homogeneous (“mix‐incubate‐read”) droplet microfluidic assay for specific protein detection in picoliter volumes by fluorescence polarization (FP), for the first time demonstrating the use of FP in a droplet microfluidic assay. Using an FP‐based assay we detect streptavidin concentrations as low as 500 nM and demonstrate that an FP assay allows us to distinguish droplets containing 5 μM rabbit IgG from droplets without IgG with an accuracy of 95%, levels relevant for hybridoma screening. This adds to the repertoire of droplet assay techniques a direct protein detection method which can be performed entirely inside droplets without the need for labeling of the analyte molecules.  相似文献   

3.
Single cell analytics for proteomic analysis is considered a key method in the framework of systems nanobiology which allows a novel proteomics without being subjected to ensemble-averaging, cell-cycle, or cell-population effects. We are currently developing a single cell analytical method for protein fingerprinting combining a structured microfluidic device with latest optical laser technology for single cell manipulation (trapping and steering), free-solution electrophoretical protein separation, and (label-free) protein detection. In this paper we report on first results of this novel analytical device focusing on three main issues. First, single biological cells were trapped, injected, steered, and deposited by means of optical tweezers in a poly(dimethylsiloxane) microfluidic device and consecutively lysed with SDS at a predefined position. Second, separation and detection of fluorescent dyes, amino acids, and proteins were achieved with LIF detection in the visible (VIS) (488 nm) as well as in the deep UV (266 nm) spectral range for label-free, native protein detection. Minute concentrations of 100 fM injected fluorescein could be detected in the VIS and a first protein separation and label-free detection could be achieved in the UV spectral range. Third, first analytical experiments with single Sf9 insect cells (Spodoptera frugiperda) in a tailored microfluidic device exhibiting distinct electropherograms of a green fluorescent protein-construct proved the validity of the concept. Thus, the presented microfluidic concept allows novel and fascinating single cell experiments for systems nanobiology in the future.  相似文献   

4.
Oral cancer is the sixth most common cancer worldwide and has been marked by high morbidity and poor survival rates that have changed little over the past few decades. Beyond prevention, early detection is the most crucial determinant for successful treatment and survival of cancer. Yet current methodologies for cancer diagnosis based upon pathological examination alone are insufficient for detecting early tumor progression and molecular transformation. To address this clinical need, we have developed a cell-based sensor to detect oral cancer biomarkers, such as the epidermal growth factor receptor (EGFR) whose over-expression is associated with early oral tumorigenesis and aggressive cancer phenotypes. The lab-on-a-chip (LOC) sensor utilizes an embedded track-etched membrane, which functions as a micro-sieve, to capture and enrich cells from complex biological fluids or biopsy suspensions. Once captured, "on-membrane" immunofluorescent assays reveal the presence and isotype of interrogated cells via automated microscopy and fluorescent image analysis. Using the LOC sensor system, with integrated capture and staining technique, EGFR assays were completed in less than 10 minutes with staining intensity, homogeneity, and cellular localization patterns comparable to conventional labeling methods. Further examination of EGFR expression in three oral cancer cell lines revealed a significant increase (p < 0.05) above control cells with EGFR expression similar to normal squamous epithelium. Results obtained in the microfluidic sensor system correlated well with flow cytometry (r(2) = 0.98), the "gold standard" in quantitative protein expression analysis. In addition, the LOC sensor detected significant differences between two of the oral cancer cell lines (p < 0.01), accounting for disparity of approximately 34 000 EGFR per cell according to quantitative flow cytometry. Taken together, these results support the LOC sensor system as a suitable platform for rapid detection of oral cancer biomarkers and characterization of EGFR over-expression in oral malignancies. Application of this technique may be clinically useful in cancer diagnostics for early detection, prognostic evaluation, and therapeutic selection. Having demonstrated the functionality of this integrated microfluidic sensor system, further studies using clinical samples from oral cancer patients are now warranted.  相似文献   

5.
A novel microfluidic chip with simple design, easy fabrication and low cost, coupled with high-sensitive laser induced fluorescence detection, was developed to provide continuous single-cell analysis based on dynamic cell manipulation in flowing streams. Making use of laminar flows, which formed in microchannels, single cells were aligned and continuously introduced into the sample channel and then detection channel in the chip. In order to rapidly lyse the moving cells and completely transport cellular contents into the detection channel, the angle of the side-flow channels, the asymmetric design of the channels, and the number, shape and layout of micro-obstacles were optimized for effectively redistributing and mixing the laminar flows of single cells suspension, cell lysing reagent and detection buffer. The optimized microfluidic chip was an asymmetric structure of three microchannels, with three microcylinders at the proper positions in the intersections of channels. The microchip was evaluated by detection of anticancer drug doxorubicin (DOX) uptake and membrane surface P-glycoprotein (P-gp) expression in single leukemia K562 cells. An average throughput of 6–8 cells min−1 was achieved. The detection results showed the cellular heterogeneity in DOX uptake and surface P-gp expression within K562 cells. Our researches demonstrated the feasibility and simplicity of the newly developed microfluidic chip for chemical single-cell analysis.  相似文献   

6.
A novel microfluidic method of continually detecting and counting beads‐labeled cells from a cell mixture without fluorescence labeling was presented in this paper. The detection system is composed of a microfluidic chip (with a permanent magnet inserted along the channel), a signal amplification circuit, and a LabView® based data acquisition device. The microfluidic chip can be functionally divided into separation zone and detection zone. By flowing the pre‐labeled sample solution, the target cells will be sequentially separated at the separation zone by the permanent magnet and detected and counted at the detection zone by a microfluidic resistive pulse sensor. Experiments of positive separation and detection of T‐lymphocytes and negative separation and detection of cancer cells from the whole blood samples were carried out to demonstrate the effectiveness of this method. The methodology of utilizing size difference between magnetic beads and cell‐magnetic beads complex for beads‐labeled cell detection is simple, automatic, and particularly suitable for beads‐based immunoassay without using fluorescence labeling.  相似文献   

7.
In this study, we propose a fast, simple method to biofunctionalise microfluidic systems for cellomic investigations based on micro‐fluidic protocols. Many available processes either require expensive and time‐consuming protocols or are incompatible with the fabrication of microfluidic systems. Our method differs from the existing since it is applicable to an assembled system, uses few microlitres of reagents and it is based on the use of microbeads. The microbeads have specific surface moieties to link the biomolecules and couple cell receptors. Furthermore, the microbeads serve as arm spacer and offer the benefit of the multi‐valent interaction. Microfluidics was adapted together with topology and biochemistry surface modifications to offer the microenvironment for cellomic studies. Based on this principle, we exploit the streptavidin–biotin interaction to couple antibodies to the biofunctionalised microfluidic environment within 5 h using 200 μL of reagents and biomolecules. We selected the antibodies able to form complexes with the MHC class I (MHC‐I) molecules present on the cell membrane and involved in the immune surveillance. To test the microfluidic system, tumour cell lines (RMA) were rolled across the coupled antibodies to recognise and strip MHC‐I molecules. As result, we show that cell rolling performed inside a microfluidic chamber functionalised with beads and the opportune antibody facilitate the removal of MHC class I molecules. We showed that the level of median fluorescent intensity of the MHC‐I molecules is 300 for cells treated in a not biofunctionalised surface. It decreased to 275 for cells treated in a flat biofunctionalised surface and to 250 for cells treated on a surface where biofunctionalised microbeads were immobilised. The cells with reduced expression of MHC‐I molecules showed, after cytotoxicity tests, susceptibility 3.5 times higher than normal cells.  相似文献   

8.
The specific and covalent labeling of fusion proteins with synthetic molecules opens up new ways to study protein function in the living cell. Here we present a novel method that allows for the specific and exclusive extracellular labeling of proteins on the surfaces of live cells with a large variety of synthetic molecules including fluorophores, protein ligands, or quantum dots. The approach is based on the specific labeling of fusion proteins of acyl carrier protein with synthetic molecules through post-translational modification catalyzed by phosphopantetheine transferase. The specificity and versatility of the labeling should allow it to become an important tool for studying and manipulating cell surface proteins and for complementing existing approaches in cell surface engineering.  相似文献   

9.
10.
Zhu L  Zhang Q  Feng H  Ang S  Chau FS  Liu WT 《Lab on a chip》2004,4(4):337-341
A filter-based microfluidic device was combined with immunofluorescent labeling as a platform to rapidly detect microbial cells. The coin-sized device consisted of micro-chambers, micro-channels and filter weirs (gap = 1-2 microm), and was demonstrated to effectively trap and concentrate microbial cells (i.e., Cryptosporidium parvum and Giardia lamblia), which were larger in size than the weir gap. After sample injection, a staining solution containing fluorescently-labeled antibodies was continuously provided into the device (flow rate = 20 microl min(-1)) to flush the microbial cells toward the weirs and to accelerate the fluorescent labeling reaction. Using a staining solution that was 10 to 100 times more dilute than the recommended concentration used in a conventional glass method, those target cells with a fluorescent signal-to-noise ratio of 12 could be microscopically observed at single-cell level within 2 to 5 min prior to secondary washing.  相似文献   

11.
Liu YJ  Guo SS  Zhang ZL  Huang WH  Baigl D  Xie M  Chen Y  Pang DW 《Electrophoresis》2007,28(24):4713-4722
An integrated smart microfluidic device consisting of nickel micropillars, microvalves, and microchannels was developed for specific capture and sorting of cells. A regular hexagonal array of nickel micropillars was integrated on the bottom of a microchannel by standard photolithography, which can generate strong induced magnetic field gradients under an external magnetic field to efficiently trap superparamagnetic beads (SPMBs) in a flowing stream, forming a bed with sufficient magnetic beads as a capture zone. Fluids could be manipulated by programmed controlling the integrated air-pressure-actuated microvalves, based on which in situ bio-functionalization of SPMBs trapped in the capture zone was realized by covalent attachment of specific proteins directly to their surface on the integrated microfluidic device. In this case, only small volumes of protein solutions (62.5 nL in the capture zone; 375 nL in total volume needed to fill the device from inlet A to the intersection of outlet channels F and G) can meet the need for protein! The newly designed microfluidic device reduced greatly chemical and biological reagent consumption and simplified drastically tedious manual handling. Based on the specific interaction between wheat germ agglutinin (WGA) and N-acetylglucosamine on the cell membrane, A549 cancer cells were effectively captured and sorted on the microfluidic device. Capture efficiency ranged from 62 to 74%. The integrated microfluidic device provides a reliable technique for cell sorting.  相似文献   

12.
The ability to control cell-surface interactions in order to achieve binding of specific cell types is a major challenge for microfluidic immunoaffinity cell capture systems. In the majority of existing systems, the functionalized capture surface is constructed of solid materials, where flow stagnation at the solid-liquid interface is detrimental to the convection of cells to the surface. We study the use of ultra-high porosity (99%) nanoporous micro-posts in microfluidic channels for enhancing interception efficiency of particles in flow. We show using both modelling and experiment that nanoporous posts improve particle interception compared to solid posts through two distinct mechanisms: the increase of direct interception, and the reduction of near-surface hydrodynamic resistance. We provide initial validation that the improvement of interception efficiency also results in an increase in capture efficiency when comparing nanoporous vertically aligned carbon nanotube (VACNT) post arrays with solid PDMS post arrays of the same geometry. Using both bacteria (~1 μm) and cancer cell lines (~15 μm) as model systems, we found capture efficiency increases by 6-fold and 4-fold respectively. The combined model and experimental platform presents a new generation of nanoporous microfluidic devices for cell isolation.  相似文献   

13.
严伟  徐德顺  查赟峰  吴晓芳 《色谱》2016,34(11):1043-1047
建立了基于微流控芯片的乳腺癌微环境酸化模型和动态检测微环境酸化情况的分析方法。设计了一种多层复合式微流控芯片,将乳腺癌细胞悬液引入含有水凝胶前体的芯片培养室后,在硝酸纤维素薄膜上固化形成3D培养支架。芯片通道连续灌流模拟血流供应,并将非电化学的pH检测器引入芯片,通过图像分析得到实时的pH变化。通过观察癌细胞的存活率、增殖率、乳酸水平及pH值,分析微环境的酸化情况,同时与正常细胞进行比较。结果表明,连续灌流培养7 d,乳腺癌细胞的存活率保持在90%以上;随着培养天数的增加,芯片上癌细胞微环境的pH值逐渐降低,且灌流速度越低,pH值下降越明显,而正常细胞微环境的pH值无明显变化。基于微流控芯片的微环境酸化检测平台可实时动态检测微环境的pH值,有望成为相关肿瘤研究的有力工具。  相似文献   

14.
15.
Proper subcellular localization of the extracellular signal-regulated kinases (ERKs) is important in regulating physiological functions such as proliferation and differentiation in the pheochromocytoma cell line (PC12 cells). Thus, a direct visualization method is necessary to observe ERK localization within the cell or in crude cellular extracts. In this paper, a determination method was established for the detection of ERK2 localization in PC12 cells using green fluorescent protein (GFP) and capillary electrophoresis with laser-induced fluorescence (LIF). GFP as a reporter or labeling tag for gene expression in biochemistry and cell biology was used for the detection of ERK2 localization in PC12 cells. PC12 cells were transfected with GFP-ERK2 plasmid construct that was inserted into a variant GFP gene (enhanced green fluorescent protein), and successfully expressed GFP-ERK2 fusion proteins. GFP-ERK2 fusion proteins were detected within 5 min by CE analysis using an uncoated fused-silica capillary with LIF. Optimum conditions for GFP-ERK2 fusion proteins detection were 100 mM 3-(cyclohexylamino)-1-propanesulfonic acid buffer containing 100 mM sodium dodecylsulfate, pH 11, running at 20 degrees C. This result offers new opportunity in screening for the determination of localization of intracellular components, protein-protein interactions and kinase activity within the cells.  相似文献   

16.
Park MC  Hur JY  Kwon KW  Park SH  Suh KY 《Lab on a chip》2006,6(8):988-994
We present a simple cell docking method induced by receding meniscus to capture non-adherent yeast cells onto microwells inside a microfluidic channel. Microwells were fabricated either by capillary moulding of UV curable polyurethane acrylate (PUA) onto glass substrate or direct replica moulding of poly(dimethyl siloxane) (PDMS). A cell suspension of the budding yeast, Saccharomyces cerevisiae, was introduced into the microfluidic channel by surface tension driven capillary flow and a receding meniscus was subsequently generated by evaporation. As the meniscus progressed, one to multiple yeast cells were spontaneously captured onto microwells by lateral capillary force created at the bottom of the meniscus. Using this cell-based platform, we observed the response of yeast cells upon stimulation by a mating pheromone (alpha-factor) by monitoring the expression of green fluorescent protein (GFP) with time. It was observed that alpha-factor triggered the expression of GFP at 60 min after stimulation and the fluorescence intensity was sustained for an additional 60 min without changes.  相似文献   

17.
Chemical proteomics relies primarily on click‐chemistry‐based protein labeling and biotin‐streptavidin enrichment, but these techniques have inherent limitations. Enrichment of intracellular proteins using a totally synthetic host–guest complex is described, overcoming the problem associated with the classical approach. We achieve this by affinity‐based protein labeling with a target‐specific probe molecule conjugated to a high‐affinity guest (suberanilohydroxamic acid–ammonium‐adamantane; SAHA‐Ad) and then enriching the labeled species using a cucurbit[7]uril bead. This method shows high specificity for labeled molecules in a MDA‐MB‐231 breast cancer cell lysate. Moreover, this method shows promise for labeling proteins in live cells.  相似文献   

18.
Cellular manipulation and fluorescent measurement were performed on two types of biological cells. First, transport and retention of yeast cells were demonstrated on a glass microfluidic chip, which consists of special U-shaped microstructures. These microstructures have the openings parallel to the liquid flow and weirs perpendicular to the flow. These allow the retention of yeast cells in the U-shaped pocket and drainage of liquid over the weirs. Thereafter, the same chip was used to carry out real-time fluorescent measurement for the cellular changes in single Jurkat T cells. In this case, the Jurkat cells were localized inside the straight portion of a microchannel. Fluorescent imaging on the same, single suspension cell was carried out to study two cellular processes occurring in viable cells, (1) the intracellular conversion of fluorescein diacetate (FDA) to fluorescein; (2) the degradation of an inhibitory protein, IkappaB, as involved in the NF-kappaB signalling pathway. In the former, the increase in fluorescent intensity of single Jurkat T cells (due to fluorescein formation) was measured; whereas in the latter, the decrease in the fluorescent intensity of a single transfected Jurkat cell (due to the degradation of the IkappaB-EGFP fusion protein) was monitored. In addition, we employed a Jurkat cell expressed with IkappaB-EGFP to probe any possible action of an herbal compound, isoliquiritigenin (IQ), on the degradation of IkappaB-EGFP. These examples have demonstrated that Jurkat cells remain viable within microfluidic channels for cellular studies and that the microfluidic chip can facilitate monitoring of cellular changes of biological cells at the single cell level and in the same cell.  相似文献   

19.
Bacterial counts provide important information during the processes such as pathogen detection and hygiene inspection and these processes are critical for public health and food/pharmaceutical production. In this study, we demonstrate the quantification of the number of bacterial cells based on the autofluorescence from the cell lysate on a microfluidic chip. We tested three model pathogenic bacteria (Listeria monocytogenes F4244, Salmonella Enteritidis PT1 and Escherichia coli O157:H7 EDL 933). In the experiment, a plug of approximately 150 pL containing lysate from 240 to 4100 cells was injected into a microfluidic channel with downstream laser-induced fluorescence detection under electrophoresis conditions. We found that the autofluorescence intensity increased with the number of cells almost linearly for all three bacteria. The autofluorescence remained a single peak when the cell lysate contained a mixture of different bacterial species. We also demonstrate a simple microfluidic device that integrates entrapment and electrical lysis of bacterial cells with fluorescence detection. Such a device can carry out the quantification of bacterial cells based on lysate autofluorescence without off-chip procedures. This study offers a simple and fast solution to on-chip quantification of bacterial cells without labeling. We believe that the method can be extended to other bacterial species.  相似文献   

20.
Here we demonstrate a microfluidic perfusion system suitable for a long-term (>2 week) culture of muscle cells spanning the whole process of differentiation from myoblasts to myotubes. Cell-adhesive surface microdomains alternating with a robust cell-repellent coating mimic in vivo spatial cues for muscle cell assembly and allow for confining the fusion of myoblasts into aligned, isolated multinucleated myotubes. The microfluidic system provides accurate control of the perfusion rates and biochemical composition of the environment surrounding the cells. Comparing muscle cell-specific differentiation markers and the timing of fusion, we observed no differences in differentiation between microfluidic and traditional cultures. All differentiation assays were fully microfluidic, i.e. they were performed by sequentially changing the fluids in the micro-channels. By delivering fluorescent markers using heterogeneous laminar flows, it was possible to confine a membrane receptor labeling assay to a region smaller than a myotube. Our method can serve as an improved in vitro model for studying muscle cell differentiation and for characterizing extracellular molecules and mechanisms involved in neuromuscular differentiation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号