首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
This work describes novel devices for electric field-assisted solid phase extraction (E-SPE) and an application was carried out on the antimicrobial marbofloxacin (MAR). Conventional syringe-type SPE cartridges were easily adapted to receive two electrodes that were inserted and positioned below and above the sorbent. The adapted cartridges were coupled to a flow extraction system, which consisted of an electrophoresis power supply, a peristaltic pump and a homemade SPE manifold. These devices were used to apply electric fields during the extraction of MAR from fortified buffer and milk samples. The recovery of MAR was improved (2.3 times) or reduced (4.2 times) in comparison to conventional SPE when the top electrode was used as cathode (E-SPE(?/+)) or anode (E-SPE(+/?)), respectively. The results demonstrated that usual SPE cartridges can be easily and inexpensively adapted for applying an electric field in SPE. It was also concluded that the electric field applied in a usual SPE cartridge can be employed as a new suitable approach to enhance the extraction efficiency of ionic compounds in a complex sample matrix.  相似文献   

2.
Solid-phase extraction (SPE) was coupled to ion-trap mass spectrometry to determine clenbuterol in urine. For SPE a cartridge exchanger was used and, after extraction, the eluate was directly introduced into the mass spectrometer. For two types of cartridges, i.e. C18 and polydivinylbenzene (PDVB), the total SPE procedure (including injection of 1 mL urine, washing, and desorption) has been optimised. The total analysis, including SPE, elution, and detection, took 8.5 min with PDVB cartridges, while an analysis time of 11.5 min was obtained with C18 cartridges. A considerable amount of matrix was present after extraction of urine over C18 cartridges, resulting in significant ion suppression. With PDVB cartridges, the matrix was less prominent, and less ion suppression was observed. For single MS, a detection limit (LOD) of about 25 ng/mL was found with PDVB cartridges. With C18 cartridges an LOD of only about 50 ng/mL could be obtained. Applying tandem mass spectrometry (MS/MS) did not lead to an improved LOD due to an interfering compound. However, a considerable improvement in the LOD was obtained with MS3. The selectivity and sensitivity were increased by the combination of efficient fragmentation of clenbuterol and reduction of the noise. Detection limits of 2 and 0.5 ng/mL were obtained with C18 and PDVB cartridges, respectively. The ion suppression was 4 to 45% (concentration range: 250 to 1.0 ng/mL) after extraction of urine using PDVB cartridges, and up to 70% ion suppression was observed using C18 cartridges. With MS4, no further improvement in selectivity and sensitivity was achieved, due to inefficient fragmentation of clenbuterol and no further reduction of noise.  相似文献   

3.
Molecularly imprinted polymers (MIPs) are synthetic polymers designed to selectively extract target analytes from complex matrices (including biological matrices). The literature shows that MIPs have a degree of cross-selectivity from analytes within the same class of compounds. A commercially available MIP for tobacco-specific nitrosamines (TSNAs) is designed to be class selective for four TSNA compounds. This study sought to characterize the extent of cross-selectivity of the TSNA MIPs with other tobacco alkaloids. Cross-selectivity and recovery of the SupelMIP™ TSNA SPE cartridges was assessed with N-nitrosonornicotine (NNN), nicotine, cotinine and morphine. Their recoveries were compared with the recoveries of a nonimprinted polymer SPE cartridge, and two traditional SPE cartridges: a Waters mixed-mode cation exchange cartridge and a Waters hydrophilic–lipophilic balance cartridge. NNN and cotinine had the highest recoveries with the MIP cartridge, over 80%, and cotinine samples in urine had >80% recoveries. Nicotine had highly variable recoveries, possibly owing to differing chemical properties from the TSNAs. All three analytes had significantly different recoveries with the MIP cartridges compared with the traditional SPE cartridges. Morphine displayed nonspecific interactions with the MIP cartridges. Utilization of the TSNAs’ cross-selectivity allows for simultaneous extraction and identification of multiple tobacco biomarkers using one extraction technique.  相似文献   

4.
In this work, solid-phase extraction (SPE) trapping performance of lutein and β-carotene, which were used as the model molecules of carotenoids, was investigated. The absorption, elution, and enrichment of carotenoids on SPE cartridges with four different sorbents, i.e. C30, C18, diol, and silica, were compared respectively with the help of frontal analysis technique. The high retentions of both lutein and β-carotene were achieved on the C18 and C30 cartridges. The diol and silica cartridges only had good retention for lutein. The optimized SPE method for sample pretreatment for the carotenoids analysis was obtained after the investigation of trapping performance. The method was applied successfully to the analysis of biological sample, i.e. serum and human breast milk. The recovery, accuracy, and precision of SPE method comparing with those of traditional liquid–liquid extraction (LLE) method for the sample pretreatment for the analysis of carotenoids owned a number of advantages such as rapid, no chloroform used, and accurate versus LLE.  相似文献   

5.
The determination of target molecules in complicated matrices such as biological samples is largely dependent on sample pretreatment. Molecularly imprinted solid-phase extraction (SPE), using molecularly imprinted polymers as the adsorbent, has been demonstrated to be effective for the selective enrichment of target molecules in biological samples. In this study, molecularly imprinted polymeric microspheres were fabricated by two-step swelling polymerization using polystyrene particles as seeds, nicotinamide as the template, methacrylic acid as a functional monomer, and ethylene glycol dimethacrylate as a cross-linker. The molecularly imprinted polymeric microspheres were packed into empty SPE cartridges, and the spiked urine and serum samples were loaded separately. After an initial washing and elution step, the effluents were analyzed by high-performance liquid chromatography (HPLC) using 1:9 methanol/0.05% phosphoric acid. The obtained molecularly imprinted polymeric microspheres were uniform, and the spherical particles were well distributed. The established method was validated, and the results showed that the method was linear from 0.499 to 19.96?µg?mL?1. The limits of detection and quantification for nicotinamide were 0.3 and 0.9?µg?mL?1, respectively. The relative standard deviations were 1.55 and 2.86% in urine and serum, respectively. The spiked recoveries of nicotinamide were 86.0–98.8% and 87.0–96.8% in urine and serum, respectively. The molecularly imprinted SPE and HPLC methods in this study are useful for the pretreatment and determination of the target compounds in these matrices.  相似文献   

6.
A novel analytical technique able to determine the anti-ischemic drug trapidil in human serum and urine is proposed. In order to achieve satisfactory sensitivity and selectivity, an extraction procedure was required to isolate the drug from complex matrixes such as serum and urine. A solid-phase extraction procedure was investigated to both increase the analyte concentration and eliminate the interfering molecules present in large amounts in both matrixes. Optimization of the extraction step was realized by selecting a new polymeric sorbent based on a surface-modified styrene–divinylbenzene polymer which provided fast and efficient drug extraction. Drug quantification was performed by using the third-order derivative spectra of the SPE eluates. Absorbance specific signals at 3D335,316 and 3D316 nm for urine and serum, respectively, were demonstrated to be directly proportional to drug concentration and barely affected by residual matrix interferences. Under the optimized experimental conditions the calibration plots were linear over the concentration range 0.2–50 μg mL−1. The method was validated by analysis of a series of spiked samples. Accuracy (recovery of 95 and 94% for serum and urine, respectively) and precision (RSD below 4%) were good. Figure Assay of Trapidil in biological fluids by SPE and derivative spectrophotometry  相似文献   

7.
Summary A solid-phase extraction (SPE) method for sample clean-up followed by a reversed-phase HPLC procedure is reported for the assay of papaverine, diltiazem, desipramine and nicardipine in urine. Disposable extraction cartridges (DECs) filled with C18, C8, C2, CH and PH silica-bonded phases were used. The effect on recovery of sample pH, composition of washing and elution solvents and nature of SPE cartridge were evaluated. The selectivity of SPE was examined using spiked urine samples and the PH cartridge gave rise to the cleanest extracts. Phenyl cartridges were conditioned with methanol and acetic acid-sodium acetate buffer. Urine sample was buffered and then applied to the DEC. The washing step was with acetone-water and subsequently with methanol-acetate buffer. The analytes were eluted with methanol-acetate buffer. The extract was evaporated to dryness, reconstituted in mobile phase, and chromatographed on a reversed-phase C18 column with UV detection at 212 nm. Recoveries of the tested compounds from spiked urine samples using the PH cartridge were in all cases>80%. The within-day and between-day repeatabilities were<5% and 9%, respectively.  相似文献   

8.
The aim of this work is to establish a sensitive and reliable method for the analysis of the 16 priority Environmental Protection Agency-defined polycyclic aromatic hydrocarbons (PAHs) found in water samples. Gas chromatography (GC)-mass spectrometry (MS) and high-performance liquid chromatography (HPLC)-fluorescence detection (FLD)-UV techniques are optimized to obtain an adequate resolution of all compounds. Validation of the methods is carried out, and a good performance is observed for both techniques. The HPLC-FLD-UV technique is somewhat more sensitive than the GC-MS technique for the determination of PAHs; thus, the HPLC-FLD-UV method is used to follow up both the solid-phase extraction (SPE) analysis using cartridges and discs and the liquid-liquid extraction (LLE), which are also evaluated for the extraction of the PAHs. Low recoveries between 43% and 79% are obtained using SPE cartridges, and higher values are obtained using SPE discs (56-96%) and LLE (60-105%). Better results are obtained using the LLE technique, and, thus, analysis of real water samples is carried out using this technique. LODs between 0.6 and 21 ng/L and relative standard deviations less than 15% are obtained using a spiked water sample analyzed using the full LLE HPLC-FLD-UV method.  相似文献   

9.
In this study, a new procedure, based on on-line solid-phase extraction (SPE) and analysis by liquid-chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS), has been developed for the simultaneous, multianalyte determination of 21 selected pesticides, phenols and phthalates in water. SPE was carried out on polymeric PLRP-s cartridges by percolating 20 mL-samples. For sample preconcentration, the performance of a prototype programmable field extraction system (PROFEXS) was evaluated against the commercial laboratory bench Prospekt system used for method development. The Profexs is designed for the automated on-site sampling, SPE preconcentration, and storage of up to 16 samples in SPE cartridges. These cartridges are further eluted and on-line analyzed with the Prospekt coupled to the chromatographic system. In the optimized method, where completely on-line SPE-LC-MS analysis of the samples is carried out with the Prospekt in the laboratory, detection limits lower than 100 ng/L, and satisfactory precision (relative standard deviations <25%) and accuracies (recovery percentages >75%) were obtained for most investigated compounds from the analysis of spiked Milli-Q water. The extraction efficiency achieved with the Profexs was comparable to that of the Prospekt for most compounds and somewhat lower for the most apolar analytes, probably due to adsorption on the pump filters. The completely on-line optimized method was applied to the analysis of surface water, ground water and drinking water from a waterworks in Barcelona. Some pesticides and phenols were found in both surface water and groundwater at ng/L or µg/L levels, but not in the final drinking water. Di(2-ethylhexyl)phthalate (DEHP) was present in all samples investigated, including blanks. To the author's knowledge, this is the first work describing the application of a fully automated on-line SPE-LC-MS method for the simultaneous analysis of pesticides, phenols, and phthalates in water, and the second one that examines the possibilities of the prototype Profexs for automated on-site SPE preconcentration of organic pollutants from water samples.  相似文献   

10.
A method for the liquid chromatography/tandem mass spectrometric (LC/MS/MS) quantification of piritramide, a synthetic opioid, in plasma after conventional off-line solid-phase extraction (SPE) and in urine by on-line SPE-LC/MS/MS in positive electrospray mode was developed and validated. Applicability of the on-line approach for plasma samples was also tested. Deuterated piritramide served as internal standard. For the off-line SPE plasma method mixed cation-exchange SPE cartridges and a 150 x 2 mm C18 column with isocratic elution were used. For the on-line SPE method, a Waters Oasis HLB extraction column and the same C18 analytical column in a column-switching set-up with gradient elution were utilized. All assays were linear within a range of 0.5-100 ng/mL with a limit of detection of 0.05 ng/mL. The intra- and interday coefficients of variance ranged from 1.3 to 6.1% for plasma and 0.5 to 6.4% for urine, respectively. The extraction recovery for the off-line plasma assay was between 90.7 and 100.0%. Influence of matrix effects, and freeze/thaw and long-term stability were validated for both approaches; influence of urine pH additionally for quantification in urine.  相似文献   

11.
Summary Solid-phase extraction (SPE) was coupled at-line to capillary electrophoresis (CE) for the determination of a series of basic test compounds (i. e. tricyclic antidepressants). The analysis was performed using a non-aqueous CE buffer, which resulted in baseline separation of all test compounds. This is in marked contrast with CE using aqueous buffers where hardly any separation was obtained either with or without micelles. The SPE procedure was used to remove simultaneously most of the water from the sample, because no direct analysis of aqueous samples is possible when a non-aqueous CE buffer is used. With the present method the antidepressants can be determined in both urine and serum. Analyte detectability is increased up to 10-fold due to trace enrichment during the extraction process; the limits of detection (LODs; UV 214 nm) are 30–300 ng mL−1 in urine and 300–1000 ng mL−1 in serum. TheRSD values (n=5) of the within-day and between-day precision are below 9% and 11% respectively. Therefore, the present procedure can be used for drug monitoring.  相似文献   

12.
A organically modified molecularly imprinted silica (MIS), selective for methylxanthines, was prepared using a simple sol-gel procedure. Caffeine was used as template; 3-aminopropyltrimethoxysilane (APTMS) as functional monomer and tetraethyl orthosilicate (TEOS) as reticulating agent. The material was packed on solid-phase extraction (SPE) cartridges and evaluated with aqueous test samples, natural water and human urine; a quantitative method for methylxanthines in water, using SPE cartridges packed with the MIS coupled with HPLC-UV was developed. The MIS was highly specific for methylxanthines, with an imprinting factor of (20.5+/-1.9). The analytical method resulted in detection limits of 85 microgL(-1) for theobromine, 44 microgL(-1) for theophylline and 53 microgL(-1) for caffeine.  相似文献   

13.
Solid-phase extraction (SPE) and solid-phase microextraction (SPME) were evaluated for the analysis of short-chain chlorinated paraffins (SCCPs) in water samples using gas chromatography coupled to negative chemical ionisation mass spectrometry (GC-NCI-MS). For SPE optimisation, four commercially available SPE cartridges were tested and several SPE parameters, such as the elution solvent, elution volume and breakthrough volume were studied. The best results were obtained with Varian Bond Elut-C18. In order to achieve a high selectivity in the determination of SCCPs, GC-NCI-MS was used. Quality parameters of the optimised SPE and SPME procedures were determined, and the best results were obtained for the SPE/GC-NCI-MS method with LODs of 5 and 20 ng l(-1) for tap and river water, respectively. This method was successfully applied to the analysis of SCCPs in river water samples at concentrations below the microg l(-1) level.  相似文献   

14.
G H Tan 《The Analyst》1992,117(7):1129-1132
Solid-phase extraction (SPE) of organochlorine pesticide residues from environmental water samples was evaluated using octadecyl (C18)-bonded porous silica. The efficiency of SPE of these pesticide residues from reagent water samples at 1-5 micrograms dm-3 levels was compared with those obtained by solvent extraction with hexane and Freon TF (trichlorotrifluoroethane). Average recoveries exceeding 80% for these organochlorine pesticides were obtained via the SPE method using small cartridges containing 100 mg of 40 microns C18-bonded porous silica. The average recovery by solvent extraction with hexane and Freon TF exceeded 90% in both instances. It was concluded that the recoveries and precision for the SPE of organochlorine pesticides were poorer than those for the solvent extraction method. Organochlorine pesticide residue levels in environmental water samples from two major rivers flowing through predominantly rice-growing areas were monitored by gas chromatography using the solvent extraction method with hexane. Exceptionally high levels of organochlorine pesticide residues such as BHC, DDT, heptachlor, endosulfan and dieldrin were found in these water samples.  相似文献   

15.
Servais AC  Chiap P  Hubert P  Crommen J  Fillet M 《Electrophoresis》2004,25(10-11):1632-1640
Nonaqueous capillary electrophoresis (NACE) was successfully applied to the resolution and the determination of salbutamol enantiomers in urine samples using heptakis(2,3-di-O-acetyl-6-O-sulfo)-beta-cyclodextrin (HDAS-beta-CD). After optimization of the electrophoretic parameters, namely the background electrolyte (BGE) composition and the HDAS-beta-CD concentration, salbutamol enantiomers were completely resolved using a BGE made up of 10 mM ammonium formate and 15 mM HDAS-beta-CD in methanol acidified with 0.75 M formic acid. Isoprenaline was selected as internal standard. Solid-phase extraction (SPE) was used for sample cleanup prior to the CE separation. Different sorbents involving polar, nonpolar interactions or dual retention mechanisms were evaluated and extraction cartridges containing both nonpolar and strong cation-exchange functionalities were finally selected. Salbutamol enantiomers recoveries from urine samples were determined. The method was then successfully validated using a new approach based on accuracy profiles over a concentration range from 375 to 7500 ng/mL for each enantiomer.  相似文献   

16.
Dermorphin is a unique opioid peptide that is 30–40 times more potent than morphine. It was misused and went undetected in horse racing until 2011 when intelligence obtained from a few North American race tracks suggested its use. To prevent such misuse, a reliable analytical method became necessary for detection and identification of dermorphin in post-race horse samples. This paper describes the first liquid chromatography–tandem mass spectrometry (LC–MS/MS) method for such a purpose. Equine plasma and urine samples were pre-treated with ethylenediamine tetra-acetic acid and urea prior to solid-phase extraction (SPE) on Oasis MCX cartridges. Resulting eluates were dried under vacuum and analyzed by LC–MS/MS for dermorphin. The matrix effect, SPE efficiency, intra-day and inter-day accuracy and precision, and stability of the analyte were assessed. The limit of detection was 10 pg/mL in plasma and 20 pg/mL in urine, and the limit of confirmation was 20 pg/mL in plasma and 50 pg/mL in urine. Dermorphin in plasma is stable at ambient temperature, but its diastereomer is unstable. With isotopically labeled dermorphin as an internal standard, the quantification range was 20–10,000 pg/mL in plasma and 50–20,000 pg/mL in urine. The intra-day and inter-day accuracy was from 91 % to 100 % for the low, intermediate, and high concentrations. The intra-day and inter-day coefficients of variation were less than 12 %. The method differentiates dermorphin from its diastereomer. This method is very specific for identification of dermorphin in equine plasma and urine, as assessed by BLAST search and targeted SEQUEST search, and by MS/MS spectrum library search. The method has been successfully applied to analysis of samples collected following dermorphin administration to research horses and of official post-race samples.
Figure
?  相似文献   

17.
Summary Biological samples must be purified before chromatography to eliminate interfering compounds. Discs have recently been developed to enhance the performance of solid-phase extraction (SPE) and reduce solvent consumption. This type of support is available in all the bonded-phases typically found in conventional packed SPE devices. The process for solid-phase extraction of [125I]-methadone from water and serum (i.e. retention and losses of [125I]-methadone during sample loading, washing, elution, etc.) has been studied to determine the behaviour of this compound on several extracting supports. For serum solutions we observed significant matrix effects on discs because of their low capacity. This resulted in loss of [125I]-methadone during the loading step because the contact time between the analyte and the functional groups of the support was too short. Although mixed-mode discs, which have both hydrophobic and cation-exchange extraction mechanisms, do not perform as well as conventional cartridges, they can, nevertheless, be used before liquid chromatographic analysis because of their several mechanical and economical advantages in comparison with cartridges.  相似文献   

18.
A method has been developed to separate hydroxylated metabolites of the carcinogenic polycyclic aromatic hydrocarbon benzo[a]pyrene, i. e. trans-4,5-, 7,8-, 9,10-dihydrodiol and 1-, 3-, 7-, and 9-phenol, by HPLC with amperometric detection employing an isocratic methanol/water eluent (70:30, v/v) containing 0.5 g/L sulfuric acid and 1 g/L lithium perchlorate. Compared with the usually applied fluorescence (λex = 265 nm, λem = 460 nm) and ultraviolet (λ = 265 nm) detection, the amperometric technique is about 2–12 times more sensitive for the determination of all metabolites investigated. The method was applied to the determination of the seven metabolites of benzo[a]pyrene in different water samples and in urine after solid-phase extraction (SPE). The results obtained by HPLC with amperometric detection after SPE enrichment from an aqueous extract of a soil sample and from the urine of a rat intragastrically treated with benzo[a]pyrene agreed well with the values determined with fluorescence and/or UV detection.  相似文献   

19.
A method was developed and validated for the determination of residues of the organophosphorus nematicide fosthiazate in soil and water by using reversed-phase liquid chromatography with UV detection. Good recoveries (>85%) of fosthiazate residues were obtained from water samples (drinking water, groundwater, and liquid chromatography water) after passage of 0.5-2 L water through solid-phase extraction (SPE) C-18 cartridges and subsequent elution with ethyl acetate. Residues in soil were extracted with methanol-water (75 + 25, v/v) on a wrist-action shaker, and the extract was cleaned up on C-18 SPE cartridges before analysis. The method was validated by analysis of a range of soils with different physicochemical characteristics; recoveries exceeded 87% at fortification levels ranging from 0.02 to 5.0 mg/kg. The precision values obtained for the method, expressed as repeatability and reproducibility, were satisfactory (<11%). Fosthiazate detection limits were 0.025 microg/L and 0.005 mg/kg for water and soil samples, respectively. The decline in the levels of fosthiazate residues in soil was measured after application of fosthiazate to protected tomato cultivation. The dissipation of fosthiazate residues followed first-order kinetics with a calculated half-life of 21 days.  相似文献   

20.
An automated method based on the on-line coupling of anion-exchange solid-phase extraction (SPE) and cation-exchange liquid chromatography followed by post-column derivatization and fluorescence detection has been developed for the trace level determination of glyphosate and its primary conversion product aminomethyl phosphonic acid (AMPA) in water. PRP-X100 poly(styrene-divinylbenzene)-trimethylammonium anion-exchange cartridges (20 x 2 mm, 10 microm) were selected for the SPE of glyphosate and AMPA. The ionic compounds present in the samples strongly influenced the extraction of both analytes; however, when an on-line ion-exchange clean-up step was introduced before sample SPE, the problem was largely solved. By processing 100-ml samples detection limits better than 0.02 microg/l for glyphosate and 0.1 microg/l for AMPA were achieved in river water. Both analytes were unstable in solution and the approach of storing samples on the PRP-X100 SPE cartridges was evaluated for a period of 1 month under three different storage conditions (deep freeze, refrigeration and 20 degrees C).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号