首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A new type of carbon paste electrode (CPE) was made using ketotifen fumarate (C23H23NO5S; an antiasthmatic/antianaphylactic drug) and hexacyanoferrate. This electrode was constructed using an acidic solution of ketotifen fumarate and potassium hexacyanoferrate. For this purpose, ketotifen fumarate was dissolved in acidic solution (pH 1) and hexacyanoferrate was added by agitation, resulting in ketotifen–hexacyanoferrate (Ket–HCF) precipitate. The obtained precipitate was separated and introduced into carbon paste. The electrochemical behavior of Ket–HCF CPE was studied by cyclic voltammetry. A modified electrode shows one pair of peaks with surface-confined characteristics, with a 0.1-M phosphate buffer as supporting electrolyte. The effects of pH, alkali metal cations, and anions of supporting electrolytes on the electrochemical characteristics of modified electrodes were studied. The diffusion coefficients of hydrated K+ in film (D), the transfer coefficient (α), and the transfer rate constant for electrons (k s) were determined.  相似文献   

2.
This work reports the use of and -cyclodextrin-modified carbon paste electrodes (CPE-CD and CPE-CD) to determine simultaneously Pb(II) and Cd(II) by means of the electrochemical technique known as anodic stripping voltammetry (ASV). Both modified electrodes displayed good resolution of the oxidation peaks of the said metals. Statistic analysis of the results strongly suggests that the CPE-CD exhibited a better analytical response that the CPE-CD, while the detection limits obtained for Pb(II) were 6.3×10–7 M for the CPE-CD and 7.14×10–7 M for the CPE-CD, whereas for Cd(II) they were 2.51×10–6 M for the CPE-CD and 2.03×10–6 M for the CPE-CD.  相似文献   

3.
In this study, cyclic voltammetry and differential pulse voltammetry were used to determine the electrochemical properties and concentration of naproxen in pharmaceutical formulation and human serum samples by using a carbon paste electrode modified with activated carbon nanoparticles. Optimum conditions were obtained at an electrode with 0.005 g activated carbon nanoparticles in a phosphate buffer solution of pH 6 as a supporting electrolyte. Linear calibration curves were obtained in the range of 0.1–120 μM, and the detection limit of naproxen determined was 0.0234 μM. The modified electrode shows good selectivity for naproxen in the presence of some organic and inorganic interferences and very good precision in real samples. Finally, naproxen was measured in the presence of acetaminophen.  相似文献   

4.
A carbon paste electrode(CPE) chemically modified with multiwall carbon nanotubes and ferrocene(FC) was used as a selective electrochemical sensor for the simultaneous determination of trace amounts of cysteamine(CA) and folic acid(FA).This modified electrode showed very efficient electrocatalytic activity for the anodic oxidation of CA.The peak current of differential pulse voltammograms of CA and FA increased linearly with their concentration in the ranges of 0.7-200μmol/L CA and 5.0- 700μmol/L FA.The detection limits for CA and FA were 0.3μmol/L and 2.0μmoI/L,respectively.The diffusion coefficient(D) and transfer coefficient(α) of CA were also determined.These conditions are sufficient to allow determination of CA and FA both individually and simultaneously.  相似文献   

5.
Zhang Y  Zheng J 《Talanta》2008,77(1):325-330
An ionic liquid modified carbon paste electrode (IL/CPE) had been fabricated by using hydrophilic ionic liquid 1-amyl-3-methylimidazolium bromide ([AMIM]Br) as a modifier. The IL/CPE was characterized by scanning electron microscope and voltammetry. Electrochemical behavior of rutin at the IL/CPE had been investigated in pH 3.29 Britton-Robinson (B-R) buffer solution by cyclic voltammetry (CV) and square wave voltammetry (SWV). The experimental results suggested that the modified electrode exhibited an electrocatalytic activity toward the redox of rutin. The electron transfer coefficient (α) and the standard rate constant (ks) of rutin at the modified electrode were calculated. Under the selected conditions, the reduction peak current was linearly dependent on the concentration of rutin in the range of 4.0 × 10−8 to 1.0 × 10−5 mol L−1 (r = 0.9998), with a detection limit of 1.0 × 10−8 mol L−1 (S/N = 3). The relative standard deviation (R.S.D.) for six times successful determination of 8.0 × 10−7 mol L−1 rutin was 1.2%. The proposed method was applied to determine rutin in tablet and urine sample. In addition, the IL/CPE exhibited a distinct advantage of simple preparation, surface renewal, good reproducibility and good stability.  相似文献   

6.
Carbon modified by the reduction of aromatic diazonium derivatives was first used as electrode for the electrochemical stripping analysis of heavy metals. As a model, the glassy carbon electrode was modified with benzoic acid by electrochemical reduction of diazobenzoic acid, and the resulting modified electrodes were used for determination of Cd2+ and Pb2+. The anodic peak currents of cadmium and lead at the benzoic acid-modified glassy carbon electrode are 7.2 and 6 times of that at the bare glassy carbon electrode. A linear response was observed for Pb2+ and Cd2+ in the range of 0.5–50 μg/l. The detection limits are 0.20 μg/l for Pb2+ and 0.13 μg/l for Cd2+. The relative standard deviations for six consecutive measurements of 50 μg/l Cd2+ and 50 μg/l Pb2+ are 0.82% and 3.02%, respectively. Applicability of the sensor to the determination of Cd2+ and Pb2+ in sewerage samples was demonstrated.  相似文献   

7.
The electrooxidation of L-cysteine(L-Cys) was studied using a benzoylferrocene(BF) modified multi-wall carbon nanotube paste electrode(BFCNPE) using cyclic voltammetry(CV),square wave voltammetry(SWV) and chronoamperometry(CHA).Under optimum pH in CV the oxidation of L-Cys occurs at a potential about 215 mV less positive than that at the surface of unmodified carbon paste electrode.The catalytic oxidation peak currents were dependent on the L-Cys concentration and a linear calibration curve was obtained in the range 0.7-350.0 mmol/L of L-Cys with SWV method.The detection limit(3s) was determined as 0.1 mmol/L.This method was also used for the determination of L-Cys in some real samples.  相似文献   

8.
A multi-wall carbon nanotube (MWNT) modified glassy carbon electrode (GCE) was described for the simultaneous determination of trace levels of cadmium and lead by anodic stripping voltammetry (ASV). In pH 4.5 NaAc-HAc buffer containing 0.02 mol/l KI, Cd2+ and Pb2+ first adsorb onto the surface of a MWNT film coated GCE and then reduce at −1.20 V. During the positive potential sweep, reduced cadmium and lead were oxidized, and two well-defined stripping peaks appeared at −0.88 and −0.62 V. Compared with a bare GCE, a MWNT film coated GCE greatly improves the sensitivity of determining cadmium and lead. Low concentration of I significantly enhances the stripping peak currents since it induces Cd2+ and Pb2+ to adsorb at the electrode surface. The striping peak currents change linearly with the concentration of Cd2+ from 2.5×10−8 to 1×10−5 mol/l and with that of Pb2+ from 2×10−8 to 1×10−5 mol/l. The lowest detectable concentrations of Cd2+ and Pb2+ are estimated to be 6×10−9 and 4×10−9 mol/l, respectively. The high sensitivity, selectivity, and stability of this MWNT film coated electrode demonstrated its practical application for a simple, rapid and economical determination of trace levels of Cd2+ and Pb2+ in water samples.  相似文献   

9.
An electrochemical study of several solids, such as MnCl2 · 4 H2O(s), MnF3(s), Fe2O3(s), Fe3O4(s) and MnO2(s), using carbon paste electrodes with electrolytic binders, is described. Results obtained have been compared with results of earlier electrochemical experiments to carry out the characterization of technological material, such as manganese ferrite. The voltammograms obtained represent the “electrochemical spectra” of solid or dissolved substances that can be used to characterize the material without previous solubilization, as charge transfer processes can proceed in the solid or dissolved state, depending on the solubility in the binder used. Received: 9 December 1996 / Accepted: 14 April 1997  相似文献   

10.
The present work describes the development and application of a carbon paste electrode modified by treated-Pennisetum setosum for the determination of lead(II) by anodic stripping differential pulse voltammetry. Most experiments were performed using the preconcentration/voltammetry/regeneration scheme. The resulting modified electrode offers a preferential uptake of lead(II) from solutions. Operational conditions, such as percentage treated-Pennisetum loading in the carbon paste, pH of electrolyte solution, ionic strength, preconcentration time, voltammetric waveform and interference are characterized and optimized to allow quantitative determination of lead. The electrode surface can be regenerated by immersing the modified electrode in 0.05 mol l−1 hydrochloric acid for 2 min. For the measurement step, the optimum conditions were acetate buffer pH 5.0 and 0.60 ionic strength with the preconcentration time of 5 min. The modified electrode contained 10% (w/w) treated-Pennisetum. The detection limit (3σ) was 0.01 mg l−1 Pb(II). For 16 preconcentration/measurement/renewal cycles, the responses could be reproduced with a 5.39% relative standard deviation. This method has been be successfully applied to the determination of lead(II) in natural water samples using standard addition method.  相似文献   

11.
An ionic liquid-type carbon paste electrode (IL-CPE) had been fabricated by replacing non-conductive organic binders with a conductive room temperature ionic liquid, 1-pentyl-3-methylimidazolium hexafluorophosphate (PMIMPF6). The electrochemical responses of calcium dobesilate were investigated at the IL-CPE and the traditional carbon paste electrode (T-CPE) in 0.05 mol L−1 H2SO4, respectively. The results showed the superiority of IL-CPE to T-CPE in terms of provision of higher sensitivity, faster electron transfer and better reversibility. A novel method for determination of calcium dobesilate was proposed. The oxidation peak current was rectilinear with calcium dobesilate concentration in the range of 8.0 × 10−7 to 1.0 × 10−4 mol L−1, with a detection limit of 4.0 × 10−7 mol L−1(S/N = 3) by differential pulse voltammetry. The proposed method was applied to directly determine calcium dobesilate in capsule and urine samples.  相似文献   

12.
The electrooxidation of the antitumour drug 2-methyl-9-hydroxyellipticinium (Celiptium) was investigated by cyclic, differential-pulse and adsorptive voltammetry at carbon paste (CPE) and lipid-modified carbon paste electrodes (LM-CPE). The influence of the paste composition, i.e., the ratio of graphite to binder, was studied in order to elucidate the nature of the accumulation process at the surface of the CPE. The electrode surface coverage at saturation was calculated. A.c. measurements at the CPE and at the LM-CPE during the accumulation of Celiptium demonstrated an increased differential double layer capacity of the LM-CPE. The influence of several parameters that affect the adsorptive step at the CPE was investigated, such as pH, ionic strength and interfering ions. Improved signals were obtained at the CPE and the detection limit in 0.1 M sodium perchlorate (tacc.=3 min) was found to be 2 × 10?10 M. Measurements of the drug in dilute standard serum samples were done using the medium-exchange technique.  相似文献   

13.
Ashrafi AM  Vytřas K 《Talanta》2011,85(5):2700-2702
A new procedure was elaborated to determine mercury(II) using an anodic stripping square-wave voltammetry at the antimony film carbon paste electrode (SbF-CPE). In highly acidic medium of 1 M hydrochloric acid, voltammetric measurements can be realized in a wide potential window. Presence of cadmium(II) allows to separate peaks of Hg(II) and Sb(III) and apparently catalyses reoxidation of electrolytically accumulated mercury, thus allowing its determination at ppb levels. Calibration dependence was linear up to 100 ppb Hg with a detection limit of 1.3 ppb. Applicability of the method was tested on the real river water sample.  相似文献   

14.
El-Desoky HS  Ghoneim MM 《Talanta》2011,84(1):223-234
Silymarin is one of the most powerful natural substances that have the ability to protect and rebuild the liver cells damaged by alcohol and other toxic substances. Silymarin showed two irreversible anodic peaks in buffered solutions (pH 2.5-8.0) at either the bare carbon paste electrode or the montmorillonite-Ca modified carbon paste one. These two peaks have been attributed to oxidation of the two phenolic OH groups at positions C-20 and C-7 of silymarin molecule. A square-wave adsorptive anodic stripping voltammetry method was optimized for determination of silymarin utilizing the bare and the modified carbon paste electrodes. The method was fully validated and successfully applied for the determination of silymarin in commercial formulations and human serum without prior extraction utilizing both carbon paste electrodes. Limits of quantitation of 1 × 10−7 and 7 × 10−9 mol L−1 silymarin have been achieved in bulk form or in formulations while 2 × 10−7 and 8 × 10−9 mol L−1 silymarin were achieved in spiked human serum utilizing the bare carbon paste electrode and the modified one, respectively. The two electrodes exhibited excellent selectivity towards silymarin even in the presence of 102to 103-fold excess of its co-formulated drugs, common excipients, and common metal ions. The pharmacokinetic parameters of silymarin in plasma of healthy human volunteers were estimated following the administration of a single oral dose of 120 mg silymarin utilizing the modified carbon paste electrode. The estimated pharmacokinetic parameters were favorably compared with those reported in literature.  相似文献   

15.
A sensitive and stable electrochemical sensor was developed by modification of carbon paste electrode with ZrO2/graphene/chitosan nanocomposite. The modified sensor served as a potential electrocatalytic platform for dopamine. Electrochemical impedance spectroscopy studies indicated reduction of charge transfer resistance at the modified electrode surface thereby facilitating the electron transfer process which resulted in higher current response to dopamine. The electrochemical behavior of dopamine at the modified electrode was studied using cyclic and square wave voltammetry. The maximum current response for the electro-oxidation of dopamine was observed at pH 7.4 and the process was realized to be diffusion controlled. The modified sensor demonstrated linearity in the range 1000–5000 nM, with high sensitivity (22 nA/nM), detection limit of 11.3 nM and selectivity for dopamine in the presence of ascorbic and uric acid which are found to co-exist with dopamine in physiological media. The method was employed for quantification of dopamine in a pharmaceutical formulation.  相似文献   

16.
TBP碳糊修饰电极三元络合物体系测定痕量铅(Ⅱ)   总被引:5,自引:0,他引:5  
研制了磷酸三丁酯(TBP)碳糊修饰电极,在含1-苯基-3-甲基-4-苯甲酰基-5-吡唑酮(PMBP)的HCl-KCl底液中,通过电位富集,将三元络合物Pb(PMBP)2(TBP)2中的铅富集在电极上,用2.5次微分阳极溶出伏安法测定铅.铅浓度在1.0×10-9~2.5×10-7mol·L-1范围内与峰高呈良好的线性关系.该电极用于铜合金和废水中铅的测定,获得满意结果.  相似文献   

17.
A chemically modified carbon paste electrode (CPE), consisting of 2,2''-[(1E)-(1,2-phenylenebis(azanylylidene)] bis(methanylylidene)]bis(benzene-1,4-diol) (PBD) and multiwalled carbon nanotubes (CNTs), was used to study the electrocatalytic oxidation of dopamine using cyclic voltammetry, chronoamperometry, and differential pulse voltammetry (DPV). First, the electrochemical behavior of the modified electrode was investigated in buffer solution. Then the diffusion coefficient, electrocatalytic rate constant, and electron-transfer coefficient for dopamine oxidation at the surface of the PBD-modified CNT paste electrode were determined using electrochemical approaches. It was found that under optimum conditions (pH = 7.0), the oxidation of dopamine at the surface of such an electrode occurred at about 200 mV, lower than that of an unmodified CPE. DPV of dopamine at the modified electrode exhibited two linear dynamic ranges, with a detection limit of 1.0 μmol/L. Finally, DPV was used successfully for the simultaneous determination of dopamine, uric acid, and folic acid at the modified electrode, and detection limits of 1.0, 1.2, and 2.7 μmol/L were obtained for dopamine, uric acid, and folic acid, respectively. This method was also used for the determination of dopamine in a pharmaceutical preparation using the standard addition method.  相似文献   

18.
Three Mn(III) porphyrins were used for the design of carbon paste and diamond paste based microelectrodes, which were employed for the determination of dopamine in pharmaceutical and biological samples using differential pulse voltammetry (DPV). The limits of detection lie between 1.6 × 10−13 and 2.0 × 10−6 mol L−1 while the sensitivities were between 230 pA μmol L−1 and 3.24 μA mol L−1. Dopamine was recovered reliable from pharmaceutical and biological samples in percentages higher than 91.00% and 92.00%, respectively. The surface of the microelectrodes can easily be renewed by simple polishing, obtaining a fresh surface ready for use in a new assay.  相似文献   

19.
<正>In this work,we describe a new strategy for the electrochemical determination of captopril(CA) using ferrocenemonocarboxylic acid as a mediator and multiwall carbon nanotubes as sensors in aqueous solution at pH 7.0.The diffusion coefficient(D),and the kinetic parameters such as electron transfer coefficient(α).and heterogeneous rate constant(k_h),for CA were also determined using electrochemical approaches.Under the optimized conditions,the electrocatalytic oxidation peak current of captopril showed two linear dynamic ranges with a detection limit of 0.3×10~(-6) mol L~(-1) captopril.The linear calibration range was 0.8×10~(-6) to 65×10~(-6) mol L~(-1) using cyclic voltammetry.Finally,this modified electrode was also examined as a selective,simple and precise new electrochemical sensor for the determination of captopril in real samples such as drug and patient human urine.  相似文献   

20.
嵌入式超薄碳糊电极的研究及其应用   总被引:1,自引:1,他引:1  
在镍铬合金基体上,研制了一种新颖的嵌入式超薄碳糊膜电极。该电极可用作银离子的伏安测定。峰电流与Ag 离子浓度在1.0×10-10~1.0×10-6mol/L范围呈良好的线性关系,检出限为8.0×10-11mol/L。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号