首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ji X  He Z  Ai X  Yang H  Xu C 《Talanta》2006,70(2):353-357
A competitive immunoassay for clenbuterol (CLB) based on capillary electrophoresis with chemiluminescence (CL) detection was established. The method was based on the competitive reaction of horseradish peroxidase (HRP)-labeled CLB (CLB-HRP) and free CLB with anti-CLB antiserum. The factors affecting the electrophoresis and CL detection were systematically investigated with HRP as a model sample. Under the optimal conditions, the tracer CLB-HRP and the immunoassay complex were separated, and the linear range and the detection limit (S/N = 3) for CLB were 5.0-40 nmol l−1 and 1.2 nmol l−1, respectively. The proposed method has been applied satisfactorily in the analysis of urine sample.  相似文献   

2.
Indirect detection of paracetamol was accomplished using a capillary electrophoresis-chemiluminescence (CE-CL) detection system, which was based on its inhibitory effect on a luminol-potassium hexacyanoferrate(III) (K3[Fe(CN)6]) CL reaction. Paracetamol migrated in the separation capillary, where it mixed with luminol included in the running buffer. The separation capillary outlet was inserted into the reaction capillary to reach the detection window. A four-way plexiglass joint held the separation capillary and the reaction capillary in place. K3[Fe(CN)6] solution was siphoned into a tee and flowed down to the detection window. CL was observed at the tip of the separation capillary outlet. The CL reaction of K3[Fe(CN)6] oxidized luminol was employed to provide the high and constant background. Since paracetamol inhibits the CL reaction, an inverted paracetamol peak can be detected, and the degree of CL suppression is proportional to the paracetamol concentration. Maximum CL signal was observed with an electrophoretic buffer of 30 mM sodium borate (pH 9.4) containing 0.5 mM luminol and an oxidizer solution of 0.8 mM K3[Fe(CN)6] in 100 mM NaOH solution. Under the optimal conditions, a linear range from 6.6 × 10−10 to 6.6 × 10−8 M (r = 0.9999), and a detection limit of 5.6 × 10−10 M (signal-to-noise ratio = 3) for paracetamol were achieved. The relative standard deviation (R.S.D.) of the peak area for 5.0 × 10−9 M of paracetamol (n = 11) was 2.9%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.  相似文献   

3.
4.
We developed a capillary electrophoresis with chemiluminescence detection system using 2-methyl-6-p-methoxyphenylethynylimidazopyrazinone as a chemiluminescence reagent for determination of antioxidants of superoxide anions. 2-Methyl-6-p-methoxyphenylethynylimidazopyrazinone reacted with superoxide anions generated through the reaction of hypoxanthine and xanthine oxidase, and then emitted chemiluminescence. Suppression of the chemiluminescence in the presence of antioxidants for superoxide anions was introduced as a detection principle for antioxidants into the capillary electrophoresis with chemiluminescence detection system. After optimizing the analytical conditions, various antioxidants, such as superoxide dismutase, nitroblue tetrazolium, ascorbic acid, and catechin, were subjected to the present system. They gave negative peaks due to the quenching effect; the detection limits of superoxide dismutase, nitroblue tetrazolium, ascorbic acid, and catechin were 1, 100, 100, and 10 μM, respectively (S/N = 2). A model sample consisting of superoxide dismutase and nitroblue tetrazolium was satisfactorily separated and detected within ca. 10 min. We also applied the present system to analysis of catechin in green tea as a real sample.  相似文献   

5.
A novel method for the simultaneous determination of benserazide and levodopa using capillary electrophoresis(CE)- chemiluminescence(CL)has been developed.Under the optimal conditions,the detection limits(S/N=3)were 1.85μg/mL for benserazide and 0.12μg/mL for levodopa.This method was successfully applied to the determination of benserazide and levodopa in Medopar tablet,the results showed that the detected values are in accordance with those by official methods.  相似文献   

6.
吴柯  章竹君 《分析试验室》2008,27(3):102-105
设计了一种测定人血清中癌胚抗原的毛细管电泳-化学发光检测均相免疫分析新方法。采用四苯硼酸钠增强luminol-H2O2-HRP体系化学发光的原理,化学发光检测经毛细管电泳分离的,用辣根过氧化物酶(HRP)标记的癌胚抗体及免疫复合物。测定癌胚抗原的线性范围2.0~80.0μg/L(R=0.9921),检出限为0.1μg/L(绝对检出限为0.75 fg)。  相似文献   

7.
8.
By use of the high separation capability of capillary electrophoresis (CE) and ultrasensitive chemiluminescence (CL) detection, a CE-CL method was proposed for the ultrasensitive determination of trace cobalt in a single hair, which is potentially useful in construction of the fingerprint of trace elements in the hair collected from crime scenes. In this work, the CE experimental conditions, CL experimental conditions and the digestion methods for the analysis of a single hair sample for cobalt were investigated in detail. The relative limit of detection (LOD, 3σ) was 0.01 ng/mL, and the absolute LOD was 2.4 × 10− 16 g considering the sampling volume of 24 nL. Using a dry digestion method, the analytical results for certified reference hair samples by the proposed method were in good agreement with the certified values. Finally, this method was successfully used to detect trace cobalt in a single hair from three adults. It has potential applications in forensic analysis.  相似文献   

9.
Zhao Y  Zhao S  Huang J  Ye F 《Talanta》2011,85(5):2650-2654
A sensitive method based on quantum dot (QD)-enhanced capillary electrophoresis-chemiluminescence (CE-CL) detection was developed for simultaneous determination of dopamine (DA) and epinephrine (E). In this work, CdTe QD was added into the running buffer of CE to catalyze the post-column CL reaction between luminol and hydrogen peroxide, achieving higher CL emission. Negative peaks were produced due to the inhibitory effects on CL emission from DA and E eluted from the electrophoretic capillary. The decrease in CL intensity was proportional to the concentration of DA and E in the range of 8.0 × 10−8-5.0 × 10−6 M and 4.0 × 10−8-5.0 × 10−6 M, respectively. Detection limits for DA and E were 2.3 × 10−8 M and 9.3 × 10−9 M, respectively. Using this method, the levels of DA and E in human urine from healthy donors were determined.  相似文献   

10.
Chemiluminescence (CL) offers a sensitive detection method for capillary electrophoresis (CE), but the implementation of CE–CL is usually under compromised operating conditions for CE, such as the prerequisite of extreme pH buffer for optimal CL reaction at the capillary outlet. This has sometimes significantly deteriorated the separation of CE. In this study, the development of a new interface makes it possible to optimize the operating conditions for CE separation and CL detection independently. The interface consists of an on-column fracture being installed in a reservoir near the capillary end to create an electrical connection and also serve as reagent addition entrance. The capillary terminal is inserted into an end-column reservoir for CL reaction and detection. In this arrangement, the applied electric field has been decoupled from the CL detection, which is proved to effectively improve CE's performance by allowing the use of optimal CE buffers. At the same time, it enables the optimization of CL detection independently. The applicability of this interface was evaluated by using acridinium ester (AE) and luminol systems. For AE system, the interfering products of CL reagent (OH, HO2) have been prevented, and the pH range of CE buffer can be independent to the optimal pH value of AE CL reaction, which is usually below 3. The AE was detected using running buffer at pH 8.7, giving a detection limit of 0.1 nM (S/N = 3), and the theoretical plate numbers is as high as 56 000. The on-column fracture based configuration is simple, sensitive and easy to implement.  相似文献   

11.
癌胚抗原毛细管电泳-化学发光均相免疫分析   总被引:1,自引:0,他引:1  
建立了一种测定人血清中癌胚抗原的毛细管电泳-化学发光检测的均相免疫分析新方法.采用四苯硼钠增强luminol-H2 O2-HRP体系化学发光的原理,化学发光检测经毛细管电泳分离的,用辣根过氧化物酶(HRP)标记的癌胚抗体及免疫复合物.测定癌胚抗原的线性范围2.0~80.0 μg/L(R=0.9921),检出限为0.1 μg/L(绝对检出限为0.75 fg).  相似文献   

12.
A novel aptamer‐based CE with chemiluminescence (CL) assay was developed for highly sensitive detection of human immunoglobulin E (IgE). The IgE aptamer was conjugated with gold nanoparticles (AuNPs) to form AuNPs‐aptamer that could specifically recognize the IgE to produce an AuNPs‐aptamer‐IgE complex. The mixture of the AuNPs‐aptamer‐IgE complex and the unbounded AuNPs‐aptamer could be effectively separated by CE and sensitively detected with luminol‐H2O2 CL system. By taking the advantage of the excellent catalytic behavior of AuNPs on luminol‐H2O2 CL system, the ultrasensitive detection of IgE was achieved. The detection limit of IgE is 7.6 fM (S/N = 3) with a linear range from 0.025 to 250 pM. Successful detection of IgE in human serum samples was demonstrated and the recoveries of 94.9–103.2% were obtained. The excellent assay features of the developed approach are its specificity, sensitivity, adaptability, and very small sample consumption. Our design provides a methodology model for determination of rare proteins in biological samples.  相似文献   

13.
毛细管电泳安培法测定脂可平胶囊中的姜黄素   总被引:3,自引:3,他引:3  
采用毛细管电泳柱端安培检测对脂可平胶囊中的姜黄素进行测定。着重研究了缓冲溶液浓度和酸碱度、检测电位、进样时间和高压对分离测定的影响。以微Pt电极为工作电极,电极电位为 1.0 V,以V(甲醇)∶V(乙醇)∶V(水)=5∶2∶3为非水介质,磷酸二氢钾和硼砂(pH 9.5)为缓冲体系,并用二阶样条小波进行滤波处理,姜黄素在1.0~120 mg/L范围内,峰高与其质量浓度呈良好的线性关系,线性回归方程:Y=20.2 146ρ,检出限为0.02 mg/L。  相似文献   

14.
Wang J  Ren J 《Electrophoresis》2005,26(12):2402-2408
In this paper we have presented a sensitive and rapid immunoassay (IA) method by capillary electrophoresis with an enhanced chemiluminescence detection system (CE-CL) based on the catalytic effects of horseradish peroxidase (HRP) on the luminol-hydrogen peroxide reaction. The conditions for the CL reaction and electrophoresis were systematically investigated using HRP as a model sample. The linear range from 2.5 x 10(-11) to 1.0 x 10(-9) mol/L (R = 0.999), and the detection limit of 1.0 x 10(-12) mol/L (signal-to-noise ratio = 3) for HRP were achieved using para-iodophenol as CL enhancer. The relative standard deviations of the migration time and peak area for 5.0 x 10(-10) mol/L HRP (n = 7) were 0.26 and 4.8%, respectively, using a CE system with a home-built CL detector. Under the optimal condition, the HRP-labeled CA125 antibody (Ab) and the Ab-antigen complex were well separated within 4 min by CE using a high-pH buffer (pH 10.20). The assay was successfully used for quantification of CA125 in human sera from health controls and patients associated with ovarian cancer, and the recoveries of the standard addition experiments were 93-109%. Our primary results demonstrated that IA based on CE-CL detection is a powerful tool for clinical diagnosis combined with these commercial IA kits.  相似文献   

15.
毛细管电泳安培法检测酚类化合物   总被引:7,自引:0,他引:7  
使用自行设计组装的毛细管电泳柱端安培检测系统 ,对四个酚类化合物进行了分离检测。研究了工作电极、缓冲液及其 p H值、检测电压和分离电压对分离检测的影响。在优化条件下 ,4个酚在 5× 1 0 -6~ 5× 1 0 -4 mol/L范围内峰高与浓度成良好的线性关系 ,检测下限为 8.5× 1 0 -7mol/L  相似文献   

16.
17.
Liu S  Liu Y  Li J  Guo M  Pan W  Yao S 《Talanta》2006,69(1):154-159
Electrochemiluminescence (ECL) detection with capillary electrophoresis (CE) separation system was used to the rapid analysis of mefenacet within 7 min. The linear response range of mefenacet was from 1.07 × 10−8 to 5.0 × 10−7 M with a detection limit of 4.0 × 10−9 M. This technique was also applied to analyze residues of mefenacet in seedling and soil.  相似文献   

18.
This paper reviews the latest developments and analytical applications of chemiluminescence detection coupled to capillary electrophoresis (CE-CL). Different sections considering the most common CL systems have been included, such as the tris(2,2?-bipyridine)ruthenium(II) system, the luminol and acridinium derivative reactions, the peroxyoxalate CL or direct oxidations. Improvements in instrumental designs, new strategies for improving both resolution and sensitivity, and applications in different fields such as clinical, pharmaceutical, environmental and food analysis have been included. This review covers the literature from 2010 to 2015.  相似文献   

19.
氯霉素的高效毛细管电泳分离-电导检测   总被引:3,自引:2,他引:3  
在熔融石英毛细管(50μmi.d×50cm)中,以6mmol/LH3BO3 2mmol/L硼砂 体积分数0.02%TEPA(四乙烯五胺)为电泳运行介质,分离电压-15.0kV,采用毛细管电泳-电导检测法在4min内实现了氯霉素的分离检测。讨论了电渗流抑制剂的浓度、缓冲体系的组成和浓度等因素对检测结果的影响。线性检测范围为1~120mg/L,检出限为0.3mg/L。对市售氯霉素滴眼液和注射液中的氯霉素进行分析,加标回收率为93.8%~106.8%。  相似文献   

20.
The paper presents a rapid method for the determination of dioxopromethazine hydrochloride (DPZ), an antihistamine drug, by the capillary electrophoresis with electrochemiluminescene detection (CE–ECL) using tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) reagent. This CE–ECL detection method has high sensitivity, good selectivity and reproducibility for DPZ analysis. Under the optimized conditions: separation capillary, 38 cm length (25 μm i.d.); sample injection, 10 s at 8 kV; separation voltage, 12.5 kV; running buffer, 20 mmol L−1 sodium phosphate of pH 6.0; detection potential, 1.15 V; 50 mmol L−1 of phosphate buffer (pH 7.14) containing 5 mmol L−1 of Ru(bpy)32+ in ECL detection cell, the detection limit of DPZ was 0.05 μmol L−1 (S/N = 3). The linear range extended from 5 to 100 μmol L−1. The linear curve obtained was Y = 181.62 + 9.28X with a correlation coefficient of 0.9970. The relative standard deviations of the ECL intensity and the migration time for six continuous injections of 5 μmol L−1 DPZ were 3.7% and 0.92%, respectively. The CE–ECL method was applied to analyze DPZ in real samples including tablets, rat serum and human urine, and satisfactory results were obtained without interference from samples matrix. The CE–ECL technique was proved to be a potential method for the detection of DPZ in clinic analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号