首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An integrated electrochemical hydride generation cell, mainly composed of three components (a gas liquid separator, a graphite tube cathode and a reticulate Pt wire anode), was laboratory constructed and employed for the detection of arsenic by coupling to atomic fluorescence spectrometry. This integrated cell was free of ion-exchange membrane and individual anolyte, with the virtues of low-cost, easy assembly and environmental-friendly. Using flow injection mode, the sample throughput could come to 120 h−1 attributed to the small dimension of the cathode chamber. The operating conditions for the electrochemical hydride generation of arsenic were investigated in detail and the potential interferences from oxygen or various ions were also evaluated. Under the optimized conditions, no obvious oxygen quenching effects were observed. The limit of detection of As (III) for the sample blank solution was 0.2 ng mL−1 (3σ) and the relative standard deviation was 3.1% for nine consecutive measurements of 5 ng mL−1 As (III) standard solution. The calibration curve was linear up to 100 ng mL−1. The accuracy of the method was verified by the determination of arsenic in the reference materials GBW08517 (Laminaria Japonica Aresch) and GBW10023 (Porphyra crispata) and the developed method was successfully applied to determine trace amounts of arsenic in edible seaweeds.  相似文献   

2.
An electrolytic hydride generation system for determination of another hydride forming element, cadmium, by catholyte variation electrochemical hydride generation (EcHG) atomic absorption spectrometry is described. A laboratory-made electrolytic cell with lead-tin alloy as cathode material is designed as electrolytic generator of molecular hydride. The influences of several parameters on the analytical signal have been evaluated using a Plackett-Burman experimental design. The significant parameters such as cathode surface area, electrolytic current, carrier gas flow rate and catholyte concentration have been optimized using univariate method. The analytical figures of merit of procedure developed were determined. The calibration curve was linear up to 20 ng ml−1of cadmium. The concentration detection limit (3σ, n = 8) of 0.2 ng ml−1 and repeatability (relative standard deviation, n = 7) of 3.1% were achieved at 10.0 ng ml−1. It was shown that interferences from major constituents at high concentrations were significant. The accuracy of method was verified using a real sample (spiked tap water) by standard addition calibration technique. Recovery of 104% was achieved for Cd in the spiked tap water sample.  相似文献   

3.
A new method was developed for simultaneous determination of trace arsenic and selenium in different extracts of Radix Astragali by enhancement effect of ethanol in hydride generation-inductively coupled plasma-atomic emission spectrometry (HG-ICP-AES) with a microwave digestion system. The effects of the concentration of the hydride generating reagent (NaBH4), ethanol concentration, different extraction methods and pre-reducing reagents on selenium and arsenic emission intensity were discussed and optimized. The contents of selenium and arsenic in different extracts (polysaccharide, amino acid, astragaloside, and water decoction,) in Radix Astragali were analyzed. The proposed method was validated by the use of two plant reference samples {poplar leaf (GBW07604) and tea (GBW07605)}. The detection limits (3σ) were 7.0 ng L− 1 and 2.0 ng L− 1 for Se(IV) and As(III) and relative standard deviations (RSD) were 1.8% and 2.3%, respectively. The determination of Selenium and Arsenic contents in different extracts of Radix Astragali would provide useful information for the quality control of Radix Astragali.  相似文献   

4.
Slurry sampling (SS) with hydride generation atomic absorption spectrometry (HG-AAS) was used to analyze 3 particulate matter samples collected in the Bananeira Village, Brazil, in 2005. The relative standard deviation (RSD), used to assess the precision, was lower than 4.8%. The accuracy of this method was confirmed by the analysis of certified atmospheric particulate matter urban dust reference material SRM 1649a. This method (SS/HG-AAS) was used to determine total arsenic and arsenic (III) in three particulate matter samples. In these samples, the total arsenic concentrations varied from 3.8 to 20.0 ng m− 3, while As (III) concentrations varied from 2.7 to 10.5 ng m− 3. All samples were also analyzed using acid digestion in digest block with cold finger and detection for HG-AAS. A paired t-test demonstrated no significant difference (95% CL) between the results obtained using these two sample preparation procedures. The limit of quantification, calculated considering the mass of particulate matter collected on every filter, was 0.6 ng m− 3 for As total and 1.0 ng m− 3 for As (III).  相似文献   

5.
Rui Liu  Maoyang Xi  Yi Lv 《Talanta》2009,78(3):885-635
Arsine trapping on resistively heated tungsten coil was investigated and an analytical method for ultratrace arsenic determination in environmental samples was established. Several chemical modifiers, including Re, Pt, Mo, Ta and Rh, were explored as permanent chemical modifiers for tungsten coil on-line trapping and Rh gave the best performance. Arsine was on-line trapped on Rh-coated tungsten coil at 640 °C, then released at 1930 °C and subsequently delivered to an atomic fluorescence spectrometer (AFS) by a mixture of Ar and H2 for measurement. In the medium of 2% (v/v) HCl and 3% (m/v) KBH4, arsine can be selectively generated from As(III). Total inorganic arsenic was determined after pre-reduction of As(V) to As(III) in 0.5% (m/v) thiourea-0.5% (m/v) ascorbic acid solution. The concentration of As(V) was calculated by difference between the total inorganic arsenic and As(III), and inorganic arsenic speciation was thus achieved. With 8 min on-line trapping, the limit of detection was 10 ng L−1 for As(III) and 9 ng L−1 for total As; and the precision was found to be <5% R.S.D. (n = 7) for 0.2 ng mL−1 As. The proposed method was successfully applied in total arsenic determination of several standard reference materials and inorganic arsenic speciation analysis of nature water samples.  相似文献   

6.
Diverse matrix effects on the determination of bismuth, selenium and tellurium (μg g−1) in nickel-based alloys and pure copper by flow-injection hydride generation atomic absorption spectrometry (FIAS-HGAAS) were investigated. Sodium tetrahydroborate was used as the reductant. The separation of analytes from copper matrix was mandatory while the analytes were successfully determined without being separated from the alloy matrix. Hydrochloric acid was effective in the prereduction of bismuth and selenium, however, it did not give any satisfactory result for tellurium in nickel-based alloys. In this work, 5% (w/v) ascorbic acid was proved effective for the prereduction of tellurium.Successful determination of tellurium in copper was achieved when N-nitroso-N-phenylhydroxylamine (cupferron) chelation-extraction was employed for the separation of tellurium from copper matrix. Cupferron chelation-extraction was performed in phosphate buffer (a mixture of 0.2 mol l−1 sodium phosphate and 0.1 mol l−1 citric acid). Lanthanum hydroxide coprecipitation at pH 10.0±0.5 was effective for bismuth and selenium. Standard reference materials of nickel-based alloys and pure copper were analyzed using the proposed methods. The linear range for the calibration curves were 0.30-15 and 0.20-10 ng ml−1 for BiH3 and H2Se, respectively, with a correlation coefficient of 0.9995. For H2Te, the linear range for the calibration curves was 0.50-12 ng ml−1 with the correlation coefficient of 0.9994. Good agreement was obtained between experimental values and certified values. Satisfactory recovery ranged from 91±1 to 106±2% was obtained from five replicate determinations.  相似文献   

7.
Electrochemical hydride generation of thallium   总被引:1,自引:0,他引:1  
An electrochemical hydride generation (ECHG) technique was developed to improve the determination of thallium by atomic spectrometry. The technique is based on the catholyte variation system for production of thallium hydride. Using Pb-Sn alloy as cathode, a transient peak shaped signal was achieved and its height, the maximum absorbance value, was taken as an analytical parameter. Parameters that might affect the hydride generation efficiency were investigated and the analytical performance of the method under the optimized experimental conditions was assessed. The linear range was 1-250 ng mL−1 for thallium and the relative standard deviation of the method was 4.2% (RSD, n = 7). The LOD for thallium was found to be 0.8 ng mL−1, showing a significant improvement relative to conventional chemical hydride generation techniques. The proposed method was applied to the determination of thallium in unalloyed zinc standard reference material. This method offers high sensitivity, simplicity, rapidness, freeness from reagent and low acid consumption.  相似文献   

8.
Zhang WB  Gan WE  Lin XQ 《Talanta》2006,68(4):1316-1321
A novel electrochemical hydride generator has been developed for the determination of As and Sb. This newly devised hydride generator is constructed from a flowing electrolytic cell, in which the tungsten wire is selected as cathode. Compared with some cathode material usually used in electrochemical hydride generator, the tungsten cathode is of better interference tolerance, corrosion-resistant and longer working time. The characteristics of the cathode material, hydride generating efficiency and interferences of concomitant have been studied in detail. The detection limits (3σ) of As and Sb in sample solution were 0.10 μg L−1 and 0.15 μg L−1, the precisions for 11 replicate measurements of 20 μg L−1 As and Sb were 1.3% and 1.7%. The electrochemical hydride generator coupled with atomic fluorescence spectrometry has been applied to the determination of total As and Sb in tobacco samples.  相似文献   

9.
Karadjova IB  Lampugnani L  Tsalev DL 《Talanta》2005,65(4):1015-1021
Analytical procedures for electrothermal atomic absorption spectrometric (ETAAS) determination of arsenic in essential oils from lavender (Lavendula angustifolia) and rose (Rosa damascena) are described. For direct ETAAS analysis, oil samples are diluted with ethanol or i-propanol for lavender and rose oil, respectively. Leveling off responses of four different arsenic species (arsenite, arsenate, monomethylarsonate and dimethylarsinate) is achieved by using a composite chemical modifier: l-cysteine (0.05 g l−1) in combination with palladium (2.5 μg) and citric acid (100 μg). Transverse-heated graphite atomizer (THGA) with longitudinal Zeeman-effect background correction and ‘end-capped’ graphite tubes with integrated pyrolytic graphite platforms, pre-treated with Zr-Ir for permanent modification are employed as most appropriate atomizer. Calibration with solvent-matched standard solutions of As(III) is used for four- and five-fold diluted samples of lavender and rose oil, respectively. Lower dilution factors required standard addition calibration by using aqueous (for lavender oil) or i-propanol (for rose oil) solutions of As(III). The limits of detection (LOD) for the whole analytical procedure are 4.4 and 4.7 ng g−1 As in levender and rose oil, respectively. The relative standard deviation (R.S.D.) for As at 6-30 ng g−1 levels is between 8 and 17% for both oils. As an alternative, procedure based on low temperature plasma ashing in oxygen with ETAAS, providing LODs of 2.5 and 2.7 ng g−1 As in levender and rose oil, respectively, and R.S.D. within 8-12% for both oils has been elaborated. Results obtained by both procedures are in good agreement.  相似文献   

10.
A procedure has been developed for the determination of bioavailable concentrations of selenium and arsenic in estuarine sediments employing inductively coupled plasma optical emission spectrometry (ICP OES) using a concomitant metals analyzer device to perform hydride generation. The optimization of hydride generation was done in two steps: using a two-level factorial design for preliminary evaluation of studied factors and a Doehlert design to assess the optimal experimental conditions for analysis. Interferences of transition metallic ions (Cd2+, Co2+, Cu2+, Fe3+ and Ni2+) to selenium and arsenic signals were minimized by using higher hydrochloric acid concentrations. In this way, the procedure allowed the determination of selenium and arsenic in sediments with a detection limit of 25 and 30 μg kg−1, respectively, assuming a 50-fold sample dilution (0.5 g sample extraction to 25 mL sample final volume). The precision, expressed as a relative standard deviation (% RSD, n = 10), was 0.2% for both selenium and arsenic in 200 μg L−1 solutions, which corresponds to 10 μg g−1 in sediment samples after acid extraction. Applying the proposed procedure, a linear range of 0.08-10 and 0.10-10 μg g−1 was obtained for selenium and arsenic, respectively. The developed procedure was validated by the analysis of two certified reference materials: industrial sludge (NIST 2782) and river sediment (NIST 8704). The results were in agreement with the certified values. The developed procedure was applied to evaluate the bioavailability of both elements in four sediment certified reference materials, in which there are not certified values for bioavailable fractions, and also in estuarine sediment samples collected in several sites of Guanabara Bay, an impacted environment in Rio de Janeiro, Brazil.  相似文献   

11.
The present investigation is the first part of an initiative to prepare a regional map of the natural abundance of selenium in various areas of Brazil, based on the analysis of bean and soil samples. Continuous-flow hydride generation electrothermal atomic absorption spectrometry (HG-ET AAS) with in situ trapping on an iridium-coated graphite tube has been chosen because of the high sensitivity and relative simplicity. The microwave-assisted acid digestion for bean and soil samples was tested for complete recovery of inorganic and organic selenium compounds (selenomethionine). The reduction of Se(VI) to Se(IV) was optimized in order to guarantee that there is no back-oxidation, which is of importance when digested samples are not analyzed immediately after the reduction step. The limits of detection and quantification of the method were 30 ng L−1 Se and 101 ng L−1 Se, respectively, corresponding to about 3 ng g−1 and 10 ng g−1, respectively, in the solid samples, considering a typical dilution factor of 100 for the digestion process. The results obtained for two certified food reference materials (CRM), soybean and rice, and for a soil and sediment CRM confirmed the validity of the investigated method. The selenium content found in a number of selected bean samples varied between 5.5 ± 0.4 ng g−1 and 1726 ± 55 ng g−1, and that in soil samples varied between 113 ± 6.5 ng g−1 and 1692 ± 21 ng g−1.  相似文献   

12.
A sensitive procedure has been developed for selenium and tellurium determination in milk by hydride generation atomic fluorescence spectrometry (HG-AFS) after microwave-assisted sample digestion. The method provides sensitivity values of 1591 and 997 fluorescence units ng−1 ml−1 with detection limits of 0.005 and 0.015 ng ml−1 for Se and Te, respectively. The application of the developed methodology to the analysis of cow milk samples of the Spanish market evidenced the presence of concentration ranges from 11.1 to 26.0 ng ml−1 for Se, and from 1.04 to 9.7 ng ml−1 for Te having found a good comparability with data obtained after dry-ashing of samples.  相似文献   

13.
The analytical performance of a miniature quartz trap coupled with electrochemical hydride generator for antimony determination is described. A portion of the inlet arm of the conventional quartz tube atomizer was used as an integrated trap medium for on-line preconcentration of electrochemically generated hydrides. This configuration minimizes transfer lines and connections. A thin-layer of electrochemical flow through cell was constructed. Lead and platinum foils were employed as cathode and anode materials, respectively. Experimental operation conditions for hydride generation as well as the collection and revolatilization conditions for the generated hydrides in the inlet arm of the quartz tube atomizer were optimized. Interferences of copper, nickel, iron, cobalt, arsenic, selenium, lead and tin were examined both with and without the trap. 3σ limit of detection was estimated as 0.053 μg l− 1 for a sample size of 6.0 ml collected in 120 s. The trap has provided 18 fold sensitivity improvement as compared to electrochemical hydride generation alone. The accuracy of the proposed technique was evaluated with two standard reference materials; Trace Metals in Drinking Water, Cat # CRM-TMDW and Metals on Soil/Sediment #4, IRM-008.  相似文献   

14.
A modified automated on-line hyphenated system for simultaneous inorganic ionic mercury (Hg2+) and monomethylmercury (MeHg+) analysis by hydride generation (HG) or ethylation (Eth), cryofocussing, gas chromatography (GC) separation and atomic fluorescence spectrometry (AFS) detection has been improved. Both derivatization methods are investigated with respect to the chromatographic and analytical performances. They can be both affected by interferences when the AFS detection system is used. Water vapor removal using a soda lime moisture trap improves significantly the chromatographic performances, the reproducibility and the detection limits for Hg2+ and MeHg+ analyzed with both methods. For ethylation (Eth) derivatization, a scattering interference generated from low-quality ethylation reagent has also been eliminated. For HG, improved detection limits are 0.13 ng l−1 and 0.01 ng l−1 for Hg2+ and MeHg+, respectively (0.1 l water sample), and reproducibility are 5% for Hg2+ (20 ng l−1) and MeHg+ (5 ng l−1). Improved detection limits for Eth are 0.22 ng g−1 for Hg2+ and 0.02 ng g−1 for MeHg+ (1 g dry sediment sample) and the reproducibility are 5-6% for Hg2+ and MeHg+ (1-2 ng g−1).  相似文献   

15.
Two highly sensitive and selective methods based on gas chromatography coupled to mass spectrometry (GC-MS) in the selected ion monitoring (SIM) mode have been developed for the quantification of 2,6-dichlorophenol (2,6-DCP), a sex pheromone of the tick females of Anocentor nitens. Standard addition method and calibration curve techniques using 5-bromine-4-hydroxy-3-methoxybenzaldehyde (5-BrV) as internal standard (IS) afforded detection limit of 0.1 ng ml−1. The calibration curve was linear over the concentration range from 0.5 to 500 ng ml−1 for 2,6-DCP. Results show that the concentration range of sex pheromone in the extracts samples was 1.08-10.35 ng ml−1. The methods developed provided reliable procedures to determine amounts of 2,6-DCP present in ticks.  相似文献   

16.
A time-based flow injection (FI) separation pre-concentration system coupled to an electrothermal atomic absorption spectrometer (graphite furnace) has been developed for the direct ultra-trace determination of selenite and selenate in drinking water. The pre-concentration of both forms of selenium is carried out onto a micro-column packed with an anionic resin (Dowex 1X8) that is placed in the robotic arm of the autosampling device. Selenite and selenate are sequentially eluted with HCl 0.1 M and HCl 4 M, respectively. The interference of large quantities of chloride during selenium atomisation is prevented by using iridium as a “permanent” chemical modifier. The features of the pre-concentration separation system for both species are: 53% efficiency of retention and an enhancement factor of 82 for a pre-concentration time of 180 s (sample flow rate=3 ml min−1) with HCl elution volumes of 100 μl. The detection limit (3 s) is 10 ng l−1 for the two species and the relative standard deviation (n=10) at the 200 ng l−1 level is 3.5% for selenite and 5.6% for selenate. The addition of selenite and selenate stock standard solutions to tap water samples yields a 97-103% recovery of both species.  相似文献   

17.
Continuous flow (CF) chemical hydride generation (CHG) and electrochemical hydride generation (ECHG) directly coupled to a novel 40 W, atmospheric pressure, 2.45 GHz microwave microstrip Ar plasma exiting a microstrip wafer has been developed for the emission spectrometric determination of As and Sb using a miniaturized optical fiber spectrometer and a CCD-array detector. The experimental conditions for both procedures were optimized with respect to the relative net intensities of the As I 228.8 nm and Sb I 252.8 nm lines and their signal-to-background intensity ratios. Additionally, the susceptibility to interferences from Cd, Co, Cr, Cu, Fe, Ni, Pb and Zn and other hydride-forming elements in the determination of As and Sb using the CHG and ECHG techniques was investigated in detail. Under the optimized conditions, it was found that ECHG is more prone to interferences compared to CHG. The detection limits (3σ) of As (6 ng mL−1) and Sb (7 ng mL−1) obtained for the ECHG-MSP-OES method are about three times lower than in the case of the CHG-MSP-OES method due to a two-fold lower amount of H2 introduced into the MSP in case of the ECHG, resulting in a better plasma stability and reduced background level. The linearity ranges for both calibration curves to a concentration of up to 5 μg mL−1 and a precision between 2% and 7% (2 μg mL−1 and 0.050 μg mL−1 of As and Sb, respectively) were found for both methods. The developed ECHG-MSP-OES method was validated for As through the analysis of a certified coal fly ash standard reference material (NIST SRM 1633a) after sample dissolution. The derived concentration (140 ± 8 μg g−1) was found to agree well with the certified data (145 ± 15 μg g−1). The method was also successfully applied to the analysis of both a galvanic bath sample, which contained Sb and was spiked with As, and a tap water sample spiked with both analytes. Recovery rates of 99-101% and a Sb concentration of 6.6 μg mL−1 in the galvanic bath sample were revealed. The latter value showed a good agreement with the data obtained from ICP-OES analysis, which was also used for validation purpose.  相似文献   

18.
N. Campillo 《Talanta》2008,77(2):793-799
A gas chromatography method with atomic emission detection (GC-AED) for the determination of dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and inorganic arsenic was optimized. The analytes were derivatized in the sample solutions with methyl thioglycolate (TGM) and the products were extracted into cyclohexane before an aliquot of this organic phase was directly injected into the chromatograph. The procedure was applied to the analysis of seawaters, wines, beers and infant foods, the last requiring an additional enzymatic reaction prior to analyte derivatization. Detection limits in seawaters and beverages were 0.05, 0.15 and 0.8 ng mL−1 for DMA, MMA and inorganic arsenic, respectively. In infant foods the detection limits were 1, 10 and 25 ng g−1 for DMA, MMA and inorganic arsenic, respectively. Inorganic arsenic was detected in some of the seawater samples and three of the wines analyzed at concentration levels in the range 1-40 ng mL−1, and DMA in several of the infant foods in the range 20-80 ng g−1. The method was validated by analyzing a certified reference material and by recovery studies. All the samples were also analyzed by hydride generation and atomic fluorescence spectrometry (HG-AFS), which provided data for the total arsenic content.  相似文献   

19.
Maleki N  Safavi A  Doroodmand MM 《Talanta》2005,66(4):858-862
A hydride generation method for the determination of traces of selenium at ng mL−1 concentration ranges has been introduced using a solid mixture of tartaric acid and sodium tetrahydroborate. Atomic absorption spectrometry (AAS) has been used as the detection system. Several parameters such as the ratio of tartaric acid to sodium tetrahydroborate, type and amount of acid, and the reaction temperature were optimized by using 640 ng mL−1 (16 ng per 25 μL) of Se(IV) standard solution. The calibration curve was linear from 20 to 1200 ng mL−1 (0.5-30 ng Se(IV) per 25 μL). The relative standard deviation (%R.S.D.) of the determination was 1.93% and the detection limit was 10.6 ng mL−1 (265 pg per 25 μL) of Se(IV). The reliability of the method was checked using different types of environmental samples, such as several types of water, a sample of soil and also in a kind of calcium phosphate sample by standard addition method. For conversion of Se(VI) present in real samples to Se(IV), l-cysteine was added to NaBH4 and tartaric acid mixture. The results showed good agreement between this method and other hydride generation techniques.  相似文献   

20.
《Analytica chimica acta》2003,479(2):203-214
A flow injection (FI) method was developed using electrochemical hydride generation (EcHG) as a sample introduction system, coupled to an inductively coupled plasma time-of-flight mass spectrometer (ICP-TOFMS) for rapid and simultaneous determination of six elements forming hydrides (As, Bi, Ge, Hg, Sb and Se). A novel low volume electrolysis cell, especially suited for FI experiments was designed and the conditions for simultaneous electrochemical hydride generation (EcHG; electrolyte concentrations and flow rates, electrolysis voltage and current) as well as the ICP-TOFMS operational parameters (carrier gas flow rate, modulation pulse width (MPW)) for the simultaneous determination of 12 isotopes were optimized. The compromise operation parameters of the electrolysis were found to be 1.4 and 3 ml min−1 for the anolyte and catholyte flow rates, respectively, using 2 M sulphuric acid. An optimum electrolysis current of 0.7 A (16 V) and an argon carrier gas flow rate of 0.91 l min−1 were chosen. A modulation pulse width of 5 μs, which influences the sensitivity through the amount of ions being collected by the MS per single analytical cycle, provided optimum results for the detection of transient signals. The achieved detection limits were compared with those obtained by using FI in combination with conventional nebulization (FI-ICP-TOFMS); values for chemical hydride generation (FI-CHG-ICP-TOFMS) were taken from the literature. By using a 200 μl sample loop absolute detection limits (3σ) in the range of 10-160 pg for As, Bi, Ge, Hg, Sb and 1.1 ng for Se and a precision of 4-8% for seven replicate injections of 20-100 ng ml−1 multielemental sample solutions were achieved. The analysis of a standard reference material (SRM) 1643d (NIST, “Trace Elements in Water”) showed good agreement with the certified values for As and Sb. Se showed a drastic difference, which is probably due to the presence of hydride-inactive Se species in the sample. Recoveries better than 93% for Ge and Hg and 83.9% for Se were achieved on a spiked SRM sample. The developed method was successfully applied to the simultaneous multielemental determination of hydride forming elements in spring water samples originating from two different regions in Hungary.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号